Code-compliant seismic design should be essentially applied to realize the so-called emulative performance of precast concrete (PC) lateral force-resisting systems, and this study developed simple procedures to design precast industrial buildings with intermediate precast bearing wall systems considering both the effect of seismic and blast loads. Seismic design provisions specified in ACI 318 and ASCE 7 can be directly adopted, for which the so-called 1.5S y condition is addressed in PC wall-to-wall and wall-to-base connections. Various coupling options were considered and addressed in the seismic design of wall-to-wall connections for the longitudinal and transverse design directions to secure optimized performance and better economic feasibility. On the other hand, two possible methods were adopted in blast analysis: 1) Equivalent static analysis (ESA) based on the simplified graphic method and 2) Incremental dynamic time-history analysis (IDTHA). The ESA is physically austere to use in practice for a typical industrial PC-bearing wall system. Still, it showed an overestimating trend in terms of the lateral deformation. The coupling action between precast wall segments appears to be inevitably required due to substantially large blast loads compared to seismic loads with increasing blast risk levels. Even with the coupled-precast shear walls, the design outcome obtained from the ESA method might not be entirely satisfactory to the drift criteria presented by the ASCE Blast Design Manual. This drawback can be overcome by addressing the IDTHA method, where all the design criteria were fully satisfied with precast shear walls’ non-coupling and group-coupling strength, where each individual or grouped shear fence was designed to possess 1.5S y for the seismic design.
This study presents code-compliant seismic details by addressing dry mechanical splices for precast concrete (PC) beam-column connections in the ACI 318-19 code. To this end, critical observations of previous test results on precast beam-column connection specimens with the proposed seismic detail are briefly reported in this study, along with a typical reinforced concrete (RC) monolithic connection. On this basis, nonlinear dynamic models were developed to verify seismic responses of the PC emulative moment-resisting frame systems. As the current design code allows only the emulative design approach, this study aims at identifying the seismic performances of PC moment frame systems depending on their emulative levels, for which two extreme cases were intentionally chosen as the non-emulative (unbonded self-centering with marginal energy dissipation) and fully-emulative connection details. Their corresponding hysteresis models were set by using commercial finite element analysis software. According to the current seismic design provisions, a typical five-story building was designed as a target PC building. Subsequently, nonlinear dynamic time history analyses were performed with seven ground motions to investigate the impact of emulation level or hysteresis models (i.e., energy dissipation performance) on system responses between the emulative and non-emulative PC moment frames. The analytical results showed that both the base shear and story drift ratio were substantially reduced in the emulative system compared to that of the non-emulative one, and it indicates the importance of the code-compliant (i.e., emulative) connection details on the seismic performance of the precast building.
For fast-built and safe precast concrete (PC) construction, the dry mechanical splicing method is a critical technique that enables a self-sustaining system (SSS) during construction with no temporary support and minimizes onsite jobs. However, due to limited experimental evidence, traditional wet splicing methods are still dominantly adopted in the domestic precast industry. For PC beam-column connections, the current design code requires achieving emulative connection performances and corresponding structural integrity to be comparable with typical reinforced concrete (RC) systems with monolithic connections. To this end, this study conducted the standard material tests on mechanical splices to check their satisfactory performance as the Type 2 mechanical splice specified in the ACI 318 code. Two PC beam-column connection specimens with dry mechanical splices and an RC control specimen as the special moment frame were subsequently fabricated and tested under lateral reversed cyclic loadings. Test results showed that the seismic performances of all the PC specimens were fully comparable to the RC specimen in terms of strength, stiffness, energy dissipation, drift capacity, and failure mode, and their hysteresis responses showed a mitigated pinching effect compared to the control RC specimen. The seismic performances of the PC and RC specimens were evaluated quantitatively based on the ACI 374 report, and it appeared that all the test specimens fully satisfied the seismic performance criteria as a code-compliant special moment frame system.
This study presents a dry precast concrete (PC) beam-column connection, and its target seismic performance level is set to be emulative to the reinforced concrete (RC) intermediate moment resisting frame system specified in ACI 318 and ASCE 7. The key features include self-sustaining ability during construction with the dry mechanical splicing method, enabling emulative connection performances and better constructability. Test specimens with code-compliant seismic details were fabricated and tested under reversed cyclic loading, which included a PC beam-column connection specimen with dry connections and an RC control specimen. The test results showed that all the specimens failed in a similar failure mode due to plastic deformations in beam members, while the hysteretic response curve of the PC specimen showed comparable and emulative performances compared to the RC specimen. Seismic performance evaluation was quantitatively addressed, and on this basis, it confirmed that the presented system can fully satisfy all the required performance for the intermediate RC moment resisting frame.
경주 방폐물 처분시설의 1단계 시설로 건설된 지하 사일로 구조는 2014년에 10만 드럼 규모로 완공되어 현재 운영중에 있다. 지하 사일로 구조는 지름 25m, 높이 50m로써 방폐물을 저장하는 실린더부분과 돔 부분으로 구성되어 있으며, 돔부분은 운영터널과 연결 되는 하부 돔 부분과 상부 돔 부분으로 구분할 수 있다. 지하 사일로 구조의 벽체는 철근콘크리트 라이너이고, 두께는 약 1m이다. 본 논문에서는 지하 사일로 구조의 건설과정 및 운영과정의 단계별 유한요소해석을 수행하였다. SMAP-3D 프로그램을 사용하여 2차원 축대칭 유한요소해석을 수행하였다. 2차원 축대칭 유한요소모델의 신뢰성을 검토하고자 3차원 유한요소해석도 수행하였다. 본 논문 에서는 지하 사일로 구조의 구조거동을 분석하고 구조적 안전성을 검토결과를 제시하였다.
본 논문에서는 우리나라의 중저준위 방폐물 처분을 위한 사일로 형식 지하동굴의 유한요소해석을 수행하였다. 사일로의 벽체부분 은 지름 25m의 원형구조이고, 높이는 35m이다. 사일로의 천장부분은 지름 30m의 돔 형식이고, 높이 17.4m의 규모이다. 사일로는 해 수면으로부터 –80m에서 –130m에 위치하고 있다. 중저준위 방폐물 처분 1단계 시설로 6개의 사일로가 건설되어 운영되고 있으나, 본 연구에서는 1개의 사일로에 대해서 고려하였다. SMAP-3D 프로그램을 사용하여 2차원 축대칭 유한요소모델과 3차원 유한요소모델 을 생성하였다. Generalized Hoek and Brown Model이 수치해석에 적용되었다. 다양한 측압계수(수평방향 현장응력과 수직방향 현장 응력의 비)의 변화에 따른 사일로 형식 지하동굴의 유한요소해석을 수행하였으며, 수치해석결과 및 분석결과가 제시되었다.
PURPOSES: A hard shoulder lane (HSL) is a method of solving severe traffic congestion on an expressway. Recently, it has been applied to several expressways in Korea, and there have been numerous positive effects, which include increasing the road capacity and reducing traffic congestion. However, these effects have been limited due to tunnels which created a‘ bottle-neck’effect in HSL application for longer road segments. In the tunnel sections, an HSL is generally not operational owing to problems such as narrow roads and the risk of accidents. If an HSL can be extended to tunnel segments, great positive effects can be achieved. Therefore, this study was conducted to evaluate driver behavior and stability to investigate the risk of HSL in tunnels.
METHODS: The Driving Simulator experiments were conducted using some scenarios for the Geumnam and Seojong tunnels on the Seoul- Chuncheon Highway. Based on data from the experiments such as running speed, lateral replacement, and steering handling, the running stabilities of participants were analyzed. In addition, traffic flow data from VDS(Vehicle Detection System) were analyzed as before-after studies.
RESULTS: Although there were some differences in driving behaviors, most participants showed safe driving behavior at a speed of less than 50 km/h.
CONCLUSIONS : Based on driving behaviors and traffic flow analyses, it is concluded that HSL in tunnels can be an alternative to increase efficiency based on safe driving environments for speeds of below 50 km/h.
본 논문에서는 도심지 지하에 터널 전력구를 건설하는 경우 시공단계별 영향을 고려한 구조해석을 수행하였다. 해석대상의 도심지 지하에는 여러 종류의 다양한 라이프라인 구조체가 설치되어 있다. 터널전력구의 구조해석에는 지반체의 유한요소해석 프로그램인 MPDAP을 사용하였다. 라이프라인 구조체와 터널 전력구 사이의 이격거리가 가장 작은 대표적인 3개의 단면에 대하여 구조해석을 수행하였다. 터널의 굴착단계별 유한요소해석에서 발생되는 평형불균형성 문제는 평형섭동개념을 적용하여 해결하였다. 또한 터널 굴착에 의한 시간의존 변형의 영향은 하중분담율을 사용하여 시공단계별로 고려하였다. 본 연구에서 검토한 3개의 대표단면에서는 터널 전력구 주변 지반체에서 발생하는 최대변위값은 허용변위값이내를 보여주었다.
Two-dimensional (2D) nano patterns including a two-dimensional Bravais lattice were fabricated by laser interference lithography using a two step exposure process. After the first exposure, the substrate itself was rotated by a certain angle, 90˚ for a square or rectangular lattice, 75˚ for an oblique lattice, and 60˚ for a hexagonal lattice, and the 90˚ and laser incident angle changed for rectangular and the 45˚ and laser incident angle changed for a centered rectangular; we then carried out a second exposure process to form 2D bravais lattices. The band structure of five different 2D nano patterns was simulated by a beam propagation program. The presence of the band-gap effect was shown in an oblique and hexagonal structure. The oblique latticed ZnO nano-photonic crystal array had a pseudo-bandgap at a frequency of 0.337-0.375, 0.575-0.596 and 0.858-0.870. The hexagonal latticed ZnO nano-crystallite array had a pseudo-bandgap at a frequency of 0.335-0.384 and 0.585-0.645. The ZnO nano structure with an oblique and hexagonal structure was grown through the patterned opening window area by a hydrothermal method. The morphology of 2D nano patterns and ZnO nano structures were investigated by atomic force microscopy and scanning electron microscopy. The diameter of the opening window was approximately 250 nm. The height and width of ZnO nano-photonic crystals were 380 nm and 250 nm, respectively.
본 논문에서는 1편에서 얻어진 온도분포와 박리시간이력을 이용하여 지하박스구조물의 열응력을 산정하고 이에 기반한 열모멘트를 산청하였다. 또한 이때의 온도분포를 바탕으로 구조물의 열적비선형성을 고려한 극한모멘트를 산정하여 구조물의 내하력을 산정하였다. 그 결과 상부슬래브의 부모멘트 구간은 단면의 온도경사에 의해서 발생하는 열모멘트에 의해 지배받는 것으로 나타났다. 반면 정모멘트 구간은 박리에 의해 화염에 노출된 철근의 항복응력에 의해 지배받는 것으로 나타났다.
본 논문에서는 적응적 h-유한요소 세분화에 의한 박스형 절판 구조물의 선형좌굴 유한요소해석법을 제안한다. 면내회전 자유도를 갖는 변절점 평판쉘유한요소를 사용하여 유한요소의 거동을 개선하고 6자유도를 갖는 다른 유한요소와의 자유도의 연결을 용이하게 한다. 이와 같이 개발된 평판쉘유한요소에 의하여 박스형 절판구조물의 정확한 구조해석이 가능한데, 변절점유한요소를 정식화함으로써 적응적 h-유한요소 세분화시에 발생하는 다른 패턴의 사각형 유한요소 세분화망의 연결을 용이하게 해결한다. 오차평가에 대한 개선된 응력장을 얻기 위하여 상위수렴 조각회복법을 적용한다. 이와 같이 상위수렴 조각회복법에 의한 개선된 응력장에 의하여 구성된 유한요소 세분화망을 이용하여 좌굴하중과 좌굴모드를 자동적으로 구할 수 있도록 한다.
본 연구의 I부에서 유도된 포화된 다공성매체의 파동 전파속도와 감쇠에 대한 이론해를 전산코드화 하였다. 본 논문에서는 작성된 전산코드를 사용하여 파동의 전파속도와 감쇠에 미치는 외력 주파수의 영향과 재료특성치의 변화의 영향을 파악하기 위한 파라미터연구를 수행하였다. 첫 번째 형태의 파동에 대한 압축성 파동 속도는 주파수-투수성 곱이 증가함에 따라 파동속도가 하한치로부터 상한치로 변이하는 영역에서는 주파수-투수성 곱의 함수로써 변화함을 보여주었다. 또한 파동의 전파속도 변화율이 가장 클 때 감쇠값이 최대가 됨을 알 수 있었다 두 번째 형태의 파동에서 파동의 전파속도는 주파수-투수성 곱이 작은 값을 가질 때 거의 0값을 나타내며, 주파수-투수성 곱이 큰 값을 가질 때 상한값을 나타냄을 알 수 있었다.
본 논문에서는 포화된 다공성매체에서 파동의 전파속도와 감쇠를 구할 수 있는 해석적 이론해를 유도하여 제시하였다. 이론해의 유도를 위하여 압축성의 고체입자와 간극수를 고려하는 완전 연계 Field모델을 사용하였다. 완전 포화된 다공성 매체의 해석을 위한 공학적인 접근방법이 채택되었으며, 균질 영역에서 1차원 파동의 전파를 위한 이론해가 유도되었다. 본 논문에서 유도한 이론해는 고체입자의 압축성, 간극수의 압축성, 다공성입자의 변형, 공간의 감쇠(Spatial damping) 등을 고려할 수 있어 매우 다양하게 사용될 수 있다. 또한 다양한 지반체에서 두 가지 종류의 파속(Wavespeed)과 감쇠계수를 계산하는데 이용 가능하다. 본 논문에서 제시한 이론해를 전산코드화하여 파동의 전파속도와 감쇠에 대한 파라미터연구를 수행한 결과는 본 연구의 II부에 제시할 예정이다.
이 논문에서는 프리스트레스트 콘크리트 구조로 건설된 원자로 격납건물의 극한내압평가를 위해 비선형 유한요소해석을 수행하였다. 특히, 상용프로그램 사용 시 콘크리트와 긴장재의 완전부착 가정으로 인해 고려할 수 없었던 콘크리트와 긴장재 사이의 슬립효과를 모사할 수 있는 알고리즘을 개발하였다. 부착된 긴장재의 경우 부착-슬립효과를 기초로 유도된 겉보기 항복응력으로 두 재료의 상호거동을 모사할 수 있고, 비부착된 긴장재의 경우 반복해석에 의해 긴장재 전체 길이방향으로의 슬립효과를 모사할 수 있다. 개발된 알고리즘을 이용하여 도출된 긴장재의 응력-변형률 관계를 이용하여 격납건물의 축소모델에 대한 비선형 해석을 수행하였고, 수행한 결과를 바탕으로 격납건물의 극한내압은 가압중수로형과 가압경수로형 모두 설계압력의 약 3배 이상 구조적 여유가 있음을 확인하였다.
본 논문에서는 평판구조물의 정적 및 동적해석에 사용할 목적으로 성능이 향상된 평판유한요소를 제시하였다. 이 요소는 비적합변위형과 선택적 감차적분방법 그리고 대체전단변형률장을 복합적으로 적용하여 각각의 장점들을 포함하는 향상된 거동을 보여주고 있다. 또한 비적합변위형의 적용으로 발생되는 조각시험의 실패 문제점을 해결하기 위하여 직접수정법을 평판유한요소의 개선에 사용하였다. 대표적인 검증문제에 대한 수치해석작업을 통하여 본 연구에서 개발한 요소는 가상적인 제로에너지모드 및 전단잠김현상의 발생과 같은 문제를 나타내지 않음을 알 수 있었다. 특히 찌그러진 형상으로 모형화 한 경우에 있어서도 전단잠김현상이 발생하지 않았다. 본 연구에서 수행한 동적반응해석 시험에 있어서도 이론해와 잘 일치하는 결과를 보여주었다.
본 연구에서는 판형태의 압전감지기와 압전작동기가 접착되어 있는 보형태의 스마트구조물의 자유진동제어에 대한 유한요소모형화 방법을 제안한다. 압전재료의 직접압전효과와 역압전효과에 대한 구성방정식을 고려하고 변분원리를 이용하여 스마트보유한요소의 운동방정식을 유도한다. 이러한 2절점 보 유한요소근 등매개변수요소로서 Timoshenko 보이론을 기초로 한다. 따라서, 보형태의 스마트구조물을 제안하는 스마트보 유한요소에 의하여 해석함으로써 전압이 작용되는 압전작동기에 의한 구조물의 제어와 전압을 측정하는 압전감지기에 의한 구조물의 모니터링에 대한 수치적인 시뮬레이션이 가능해진다 이러한 스마트보유한요소와 Constant-gain feed back control 기법을 이용하여 압전감지기와 압전작동기를 이용한 보구조물의 자유진동제어에 대한 유한요소 모델을 제안한다
본 논문에서는 지하수의 영향을 고려하여 발파로 인한 폭발하중에 대한 지하공동구조체의 3차원 동적해석을 수행하였다. 지하공동 주변 암반체는 13.5%의 공극율을 갖는 석회암으로 가정하였으며, 동일한 폭발하중에 대해 주변 암반체의 공극이 완전히 건조한 경우와 이 공극이 완전 포화된 경우로 나누어 해석을 수행하였다. 수치해석결과 지하공동구조체가 포화된 암반체에 위치하는 경우가 건조한 암반체에 위치하는 경우에 비해 속도, 변위, 응력이 모두 크게 발생하였다. 그리고 포화된 암반체의 지하공동구조체 부근에서는 전단파괴의 가능성이 발생함을 확인할 수 있었다.