검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 16

        1.
        2018.05 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Hot-press forming(HPF) steel can be applied successfully to auto parts because of its superior mechanical properties. However, its resistances to aqueous corrosion and the subsequent hydrogen embrittlement(HE) decrease significantly when the steel is exposed to corrosive environments. Considering that the resistances are greatly dependent on the properties of coating materials formed on the steel surface, the characteristics of the corrosion and hydrogen diffusion behaviors regarding the types of coating material should be clearly understood. Electrochemical polarization and impedance measurements reveal a higher corrosion potential and polarization resistance and a lower corrosion current of the Al-coating compared with Zn-coating. Furthermore, it was expected that the diffusion kinetics of the hydrogen atoms would be much slower in the Al-coating, and this would be due mainly to the much lower diffusion coefficient of hydrogen in the Al-coating with a face-centered cubic structure. The superior surface inhibiting effect of the Al-coating, however, is degraded by the formation of local cracks in the coated layer under severe stress conditions, and therefore further study will be necessary to gain a clearer understanding of the effect of cracks formed on the coated layer on the subsequent corrosion and hydrogen diffusion behaviors.
        4,000원
        3.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The electrochemical performance for the corrosion of zinc anodes according to particle size and shape as anode in Zn/air batteries was study. We prepared five samples of Zn powder with different particle size and morphol- ogy. For analysis the particle size of theme, we measured particle size analysis (PSA). As the result, sample (e) had smaller particle size with 10.334 µm than others. For measuring the electrochemical performance of them, we measured the cyclic voltammetry and linear polarization in three electrode system (half-cell). For measuring the morphology change of them before and after cyclic voltammetry, we measured Field Emission Scanning Electron Microscope (FE- SEM). From the cyclic voltammetry, as the zinc powder had small size, we knew that it had large diffusion coefficient. From the linear polarization, as the zinc powder had small size, it was a good state with high polarization resistance as anode in Zn/air batteries. From the SEM images, the particle size had increased due to the dendrite formation after cyclic voltammetry. Therefore, the sample (e) with small size would have the best electrochemical performance between these samples.
        4,000원
        4.
        2012.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        순환전압전류법을 사용하여 전류-전압 곡선을 측정하였다. 전기화학적 특성과 금속의 표면상태간의 관계는 전자현미경(SEM)을 사용하여 조사하였다. 그리고 순환전압전류법에 의한 전기화학적 측정은 3 전극 시스템을 사용하였다. 측정 범위는 초기 포텐셜에서 -1350 mV까지 환원시키고, 연속적으로 1650 mV까지 산화시키고, 다시 초기지점으로 환원시켜 측정하였다. 스캔속도는 50, 100, 150, 200 및 250 mV/s를 선정하였다. 그 결과, 부식억제로 모노에탄올아민(MEA)을 사용하여 금속의 C-V 특성은 순환전압전류법으로부터 산화 전류에 기인한 비가역 공정으로 나타났다. 부식억제제로 MEA을 사용하였을 경우에는 전해질의 농도가 증가할수록 확산계수가 감소하는 경향을 나타내었다. 그리고 구리의 SEM 이미지를 보면, 전해질 농도를 증가시키면 표면부식은 증가하였다. 부식억제제로 1.0×10-3M MEA를 첨가시키면, 전해질 농도 0.1 N의 경우 확산계수가 상대적으로 커서 부식억제 효과가 적었다.
        4,000원
        5.
        2011.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we investigated the C-V diagrams and metal surface related to the electrochemistry characterization of metal(nickel, SUS-304). We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system. A measuring range was reduced from initial potential to -1350mV, continuously oxidized to 1650 mV and measured to the initial point. The scan rate were 50, 100, 150, 200 and 250 mV/s. As a result, the C-V characterization of metal using N,N-dimethylacetamide and N,N-dimethylformamide inhibitors appeared irreversible process caused by the oxidation current from the cyclic voltammogram. After adding organic corrosion inhibitors, adsorption film constituted, and the passive phenomena happened. According to the results by cyclic voltammetry method, it was revealed that the addition of inhibitors containing amide functional group enhances the corrosion resistance properties.
        4,000원
        10.
        2006.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문은 지하매설 철 구조물의 전기적 부식방지를 위해 Mg 희생양극을 사용하는 부식방지 기술에 대한 연구 또한 활발히 진행되고 있다. Mg 희생양극은 지하에 매설되는 철 구조물(파이프, 탱크, 파일, 고정 앵커 등)을 부식으로부터 보호하기 위하여 사용되는 것이다. 본 연구에서는 종래의 산화 소화용 표면 보호재로 이용되고 있는 비교적 값이 싼 CaCl2 염화물을 이용하여 마그네슘 합금제조 시 CaCl2 염화물의 표면보호 효과 및 제조된 Mg-Ca 합금들의 전기화학적 특성을 조사하였다 금속 Ca가 아닌 산화방지 및 소화 용제로 이용되고 있는 염화물(CaCl2)을 이용하여 자연부식 전위 값이 -1.695VSCE 이하, 사용효율도 59% 이상인 Mg-Mn-Ca 희생양극제의 제조기술을 확립하였다.
        4,000원
        12.
        2016.04 서비스 종료(열람 제한)
        In this study, Corrosion behavior in mortar was observed by the passage of time by using EIS method. As a result of EIS experiment, equivalent circuit and changes of Impedance parameter could be observed. In addition, it was confirmed that impedance of rebar in mortar and corrosion rate according to the amount of NaCl were different.
        13.
        2012.11 서비스 종료(열람 제한)
        In this study, in order to comprehend performance of corrosion inhibitor, the experiment study was conducted about corrosion characteristic of 3 steps(0.0, norm 1/2, norm) compared to organic corrosion inhibitor standard use of liquid and molar 3 steps(0.0, 0.3, 0.6%) of Chloride by added amount of inorganic corrosion inhibitor by the corrosion inhibitor types about 2.4kg/m3, 4.8kg/m3 based on Chloride ion content 1.2kg/m3 for service life prediction of concrete structure by using Poteniostat.
        14.
        2010.03 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 콘크리트 배합과 혼화재 첨가에 의한 콘크리트 물성 변화가 매립 철근의 부식을 평가하는 전기-화학적 기법에 미치는 영향을 확인하고 그 원인을 분석하였다. 연구 결과 자연전위법은 철근의 부식면적이 10% 이하일 경우 콘크리트 내부 물성에 영향을 받는 것으로 나타났으며, 혼화재가 혼입된 경우에는 높은 부식상태의 철근에 대한 정성적인 부식평가가 가능하였다. 또한 분극저항법은 부식량이 10% 이하로 미미한 경우에도 콘크리트 물성의 영향을 받지 않았으나, 혼화재가 혼입된 경우에는 비슷한 철근부식면적의 OPC보다 부식정도를 과소평가하는 것으로 나타났다.
        15.
        2008.11 KCI 등재 서비스 종료(열람 제한)
        시멘트 대체 재료로서 플라이애쉬의 사용은 시멘트 생산비용을 절감시키는 효과를 창출하였다. 반면에 플라이애쉬 혼입콘크리트는 OPC에 비해 상대적으로 긴 양생시간과 초기강도의 발현 저하를 들 수 있어 이의 해결을 위해 물리적 방법, 온도 및 화학적 방법 등과 같은 다양한 활성화 기술의 적용을 통하여 플라이애쉬 혼입 콘크리트의 수화를 가속시킬 수 있고, 콘크리트의 부식 저항성을 향상시킬 수가 있다. 본 연구에서는 10~40%의 치환률을 가진 활성화된 플라이애쉬 시편을 통해 개방 회로형 전위측정(Open circuit potential measurement)을 수행하였고, 투수시험, 급속염화물침투시험 및 SEM(Scanning electron microscopy)촬영을 통해 OPC 콘크리트와 비교․분석 하였다. 또한, 치환률의 임계범위 20~30%의 경우에 있어서 활성화된 플라이애쉬를 사용한 콘크리트가 열화저항성에 있어서 개선효과가 나타나고 있음을 확인하였다. 또한 플라이애쉬를 화학적으로 활성화시킨 경우가 본 연구에서 수행된 다른 활성화 방법들에 비해 더욱 좋은 결과를 나타나고 있음도 확인하였다.