검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 76

        22.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, chemically enhanced steam cleaning(CESC) was applied as a novel and efficient method for the control of organic and inorganic fouling in ceramic membrane filtration. The constant filtration regression model and the resistance in series model(RISM) were used to investigate the membrane fouling mechanisms. For total filtration, the coefficient of determination(R2) with an approximate value of 1 was obtained in the intermediate blocking model which is considered as the dominant contamination mechanism. In addition, most of the coefficient values showed similar values and this means that the complex fouling was formed during the filtration period. In the RISM, Rc/Rf increased about 4.37 times in chemically enhanced steam cleaning compared to physical backwashing, which implies that the internal fouling resistance was converted to cake layer resistance, so that the membrane fouling hardly to be removed by physical backwashing could be efficiently removed by chemically enhanced steam cleaning. The results of flux recovery rate showed that high-temperature steam may loosen the structure of the membrane cake layer due to the increase in diffusivity and solubility of chemicals and finally enhance the cleaning effect. As a consequence, it is expected that chemically enhanced steam cleaning can drastically improve the efficiency of membrane filtration process when the characteristics of the foulant are identified.
        4,300원
        27.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 CH4/CO2 혼합가스에서 CO2 분리를 위해 세라믹 중공사 접촉막 모듈(HFMC)을 이용하여 실험을 수행하였다. 고 내구성의 HFMC를 제작하기 위해, 고강도의 중공사막을 제조하여 평가하였다. 제조한 중공사막을 이용하여 HFMC를 제작하였고, 실험은 CH4/CO2 혼합 기체(30% CO2, CH4 balance)와 monoethanolamine (MEA)를 사용하였다. HFMC 운전 중 기체와 흡수제의 압력이 CO2 제거 효율에 어떠한 영향을 주는지 평가하였다. CO2 제거 효율은 기체압력이 증가함에 따라 같이 상승하였으며, CO2 흡수 flux 또한 액체유량과 함께 증가하는 추세를 보였다. 또한 CO2 흡수율이 40% 이하일 때 는 흡수제가 아래쪽에서 들어가는 향류형태인 LTS-1이 흡수제가 위쪽에서 들어가는 향류형태인 LTS-2보다 CO2 제거 성능 이 높았으며, 흡수율이 40% 이상일 때는 LTS-2가 LTS-1보다 성능이 높았다.
        4,000원
        30.
        2020.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 세라믹 중공사 접촉막 모듈을 이용하여 CH4/CO2 혼합가스에서 CO2 분리 실험을 수행하였다. 높은 성능의 접촉막 모듈을 제작하기 위해 고투과성 중공사막의 제조 실험을 진행하였으며, 제조한 중공사막은 N2 기체투과실험을 통해 투과 성능을 평가하였다. 최종적으로 고투과도 중공사막을 이용하여 CH4/CO2 혼합 기체 분리를 위한 Hollow fiber membrane contactor (HFMC)를 제작하였다. 실험에는 CH4/CO2 혼합 기체(34.5% CO2, CH4 balance)와 monoethanolamine (MEA) 를 사용하였으며, CO2 제거 효율이 흡수제의 유량에 따라 어떠한 영향을 받는지 평가하였다. CO2 제거 효율은 액체유량이 증가함에 따라 같이 상승하였으며, CO2 흡수 flux 또한 액체유량과 함께 증가하는 결과를 보였다.
        4,000원
        35.
        2018.11 구독 인증기관·개인회원 무료
        본 실험에서는 조류 제거 및 농축을 위해 Silicon Carbide(SiC) 재질의 침지형 세라믹막을 적용하여 운전 특성을 평가하고자 하였다. SiC 세라믹막은 막표면이 음전하를 띄어 음전하를 띄는 조류 제거에 적용이 가능하고 고유량으로 역세척(Backwashing)을 할 수 있어 고농도의 조류 농축시에도 적용이 가능하다. 역세척 유량과 역세척 시간, 역세척수 수온, 역세척수에 차아염소산나트륨 주입 유무, 여과/역세시 air scrubbing 유량에 따라 역세척 효율을 평가하였으며 Jar test를 통해 선정한 농도로 응집제 주입 유무에 따라 운전 특성을 비교하였다. 또한 동일한 조건에서 세라믹막과 유기막의 운전 특성과 비교하였다. 본 연구는 환경부의 “환경정책기반공공기술개발사업”으로 지원받은 과제입니다.
        36.
        2018.11 구독 인증기관·개인회원 무료
        천연가스, 산업공정, 화석연료의 연소과정과 같은 대규모 고정 배출원에서 발생하는 온실가스인 CO2를 포집하기 위한 기술 개발이 전 세계적으로 활발하게 수행되고 있다. 특히, 습식 흡수 법은 비교적 낮은 CO2분압에서도 높은 제거 효율을 달성할 수 있어 많은 개발이 이루어져온 포집 기술이다. 하지만 흡수제의 재생에 필요한 에너지가 과다한 문제가 있으며, 충분한 부지가 확보되어야하기 때문에 공정 상용화에는 큰 걸림돌이 있다. 이러한 문제를 극복하고 공정 효율을 개선 할 수 있는 접촉분리막 공정 기술이 최근 주목받고 있다. 본 연구에서는 접촉분리막과 화학적 습식 아민 흡수제를 이용한 이산화탄소 제거 특성을 분석하였다.
        37.
        2018.05 구독 인증기관·개인회원 무료
        지구온난화 문제 해결을 위하여 효율적인 CO2 포집 기술 개발이 활발히 이루어지고 있으며, 최근 분리막, 흡수 공정의 하이브리드 기술인 접촉막 공정이 주목받고 있다. 본 연구진은 2014년부터 열적, 화학적 안정성이 뛰어난 세라믹 소재의 중공사막을 적용한 접촉막 공정을 개발해오고 있다. 대규모 공정 실증을 위하여 세라믹 중공사막 기공 구조 제어 기술부터 소수성 코팅, 모듈 디자인 및 배치, 공정 구성 최적화 등을 연구하였다.
        38.
        2018.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the effect of chemically enhanced backwash(CEB) coping with algal(Heterosigma Akashiwo) inflow was evaluated in the seawater desalination pretreatment process using ceramic membrane. In order to confirm the possibility of long-term filtration operation, the recovery rate of transmembrane pressure(TMP) due to the CEB using NaOCl was examined. When the membrane flow rate was 83.3 LMH, the TMP was maintained within 200 kPa for 84 hours in seawater influent. As the algal counts of 30,000 cell/mL were injected into the influent of seawater, however, the TMP rapidly increased and exceed maximum value. Membrane fouling caused by the algae was very poorly recovered by usual physical backwash. The CEB was performed for 30 min(3 min circulation / 27 min immersion) with 300 mg/L of NaOCl. As a result of the CEB application, it was possible to maintain a stable operating of filtration during 10 days and the average recovery rate of TMP by the CEB was 98.1%. It has been confirmed that the CEB using NaOCl is very effective in removal of membrane fouling by algae, resulted in stable membrane filtration for the long-term operation.
        4,000원
        39.
        2018.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the effects of operating conditions on the formation of reversible and irreversible fouling were investigated in the filtration using ceramic membrane for water treatment process. The effect of coagulation pretreatment on fouling formation was also evaluated by comparing the performance of membrane filtration both with and without addition of coagulant. A resistance-in-series-model was applied for the analysis of membrane fouling. Total resistance (RT) and internal fouling resistance (Rf) increased in the membrane filtration process without coagulation as membrane flux and feed water concentrations increased. Internal fouling resistance, which was not recovered by physical cleaning, was more than 70% of the total resistance at the range of the membrane flux more than 5 m3/m2・day. In the combined process with coagulation, the cake layer resistance (Rc) increased to about 30-80% of total resistance. As the cake layer formed by coagulation floc was easily removed by physical cleaning, the recovery rate by physical cleaning was 54~90%. It was confirmed from the results that the combined process was more efficient to recover the filtration performance by physical cleaning due to higher formation ratio of reversible fouling, resulted in the mitigation of the frequency of chemical cleaning.
        4,200원
        40.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, it is estimated that ceramic membrane process which can operate stably in harsh conditions replacing existing organic membrane connected with coagulation, sedimentation etc. . Jar-test was conducted by using artificial raw water containing kaolin and humic acid. It was observed that coagulant (A-PAC, 10.6%) 4mg/l is the optimal dose. As a results of evaluation of membrane single filtration process (A), coagulation-membrane filtration process (B) and coagulation-sedimentation-membrane filtration process (C), TMP variation is stable regardless of in Flux 2 m3/m2・day. But in Flux 5 m3/m2・day, it show change of 1-89.3 kpa by process. TMP of process (B) and (C) is increased 11.8, 0.6 kpa each. But, the (A) showed the greatest change of TMP. When evaluate (A) and (C) in Flux 10 m3/m2・day, TMP of (A) stopped operation being exceeded 120 kpa in 20 minutes. On the other hand, TMP of (C) is increased only 3 kpa in 120 minutes. Through this, membrane filtration process can be operated stably by using the linkage between the pretreatment process and the ceramic membrane filtration process. Turbidity of treated water remained under 0.1 NTU regardless of flux condition and DOC and UV254 showed a removal rate of 65-85%, 95% more each at process connected with pretreatment. Physical cleaning was carried out using water and air of 500kpa to show the recovery of pollutants formed on membrane surface by filtration. In (A) process, TMP has increased rapidly and decreased the recovery by physical cleaning as the flux rises. This means that contamination on membrane surface is irreversible fouling difficult to recover by using physical cleaning. Process (B) and (C) are observed high recovery rate of 60% more in high flux and especially recovery rate of process (B) is the highest at 95.8%. This can be judged that the coagulation flocs in the raw water formed cake layer with irreversible fouling and are favorable to physical cleaning. As a result of estimation, observe that ceramic membrane filtration connected with pretreatment improves efficiency of filtration and recovery rate of physical cleaning. And ceramic membrane which is possible to operate in the higher flux than organic membrane can be reduce the area of water purification facilities and secure a stable quantity of water by connecting the ceramic membrane with pretreatment process.
        4,000원
        1 2 3 4