검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 9

        2.
        2018.04 구독 인증기관·개인회원 무료
        Entomopathogenic fungi have been known as promising candidates for biological control of insect pests. Recently, researchers consider the fungal thermotolerance in formulations and field applications. In this study, we investigated the production of thermotolerant Isaria javanica and I.fumosorosea conidia through grain-based solid cultures and exposure to light stress. As results, of the ten grain substrates, Italian millet, rice, perilla seed and sesame, rice, sorghum produced highly thermotolerant conidia in the strains. The two strains were exposed to a light stress and a heat stress. And they showed enhanced thermal stability compared to control, when exposed to 45°C for 2 hours. This work suggests that heat-resistant entomopathogenic fungal conidia can be produced by grain-based solid cultures and exposure to light stress.
        3.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated Extremely Low Frequency-Magnetic Fields (ELF-MF) exposure levels among housewives for a 24-Hour activity pattern to identify related factors for the exposures. To achieve the objective of the study, we surveyed ELF-MF levels using EMDEX II in a living environment from January to December 2016. We also made subjects write a Daily Activity Pattern in order to identify durations for staying and related information in the environment of exposures. Subjects showed that they spent the longest time in sleep and at home, at 487.5 minutes (KOSIS: 479.0 minutes) and 472.1 minutes (KOSIS: 428.0 minutes), respectively. Furthermore, the 24- hour time-weighted average (TWA) of 54 housewives was 1.24 ± 3.48 mG (GM: 0.52 mG). The ELF-MF exposure levels for all Multiuse Facilities were far below the recommended standards of EMF Guideline Korea and ICNIRP. Thus, these results will provide useful data for the determination of ELF-MF management and reduction methods in living environments.
        4,000원
        4.
        2014.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        인간의 생태계와 서식환경을 공유하고 있는 정주성 거미류의 경우 제한된 서식지 이동 특성으로 인해, 특정유해환경을 효과적으로 감시할 수 있는 환경 지표생물로서의 활용가치가 매우 높은 생명체로 판단된다. 따라서 본 연구는 석면 섬유에 노출시킨 거미의 서폐 미세구조를 관찰하고, 그 결과를 토대로 유해환경을 모니터링할 수 있는 생물지표로서의 활용 가능성에 대해 논의하였다. 고해상도의 주사전자현미경으로 서폐의 미세구조를 관찰한 결과, 기공 주위에 분지된 수지상의 큐티클지주(spike)는 기낭으로 유입되는 공기를 정화하는 필터구조로 작동하였고, 기낭 내부에 수직돌출된 큐티클 지주는 기낭 공간을 안정적으로 확보하고 호흡 표면적을 극대화하는 구조체임이 확인되었다. 짧은 노출 기간에도 불구하고, 기공 개구부의 전 영역에서 청석면의 미세섬유가 검출되어 석면과 같은 환경 오염원에 대한 효과적인 생물지표로서의 가능성을 거미의 서폐에서 확인하였다. 또한, 기낭으로 유입되어 혈림프 공간을 관통한 미세섬유는 고착구조를 형성하고 조직손상을 유발함이 관찰되었는데, 섬유 주위에 밀집된 혈구는 흔히 관찰되었으나, 섬유 표면에 부착된 혈구나 석면소체 등은 관찰되지 않았다. 이는 상대적으로 짧은 석면노출기간에서 기인하는 것으로 해석되었다.
        4,000원
        5.
        2008.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        In this study, we attempted to estimate the association between asthma oriented by indoor air sources and personal exposure by comparing the case (asthma-patient) and control (non-asthma-patient) groups. We selected 27 participants who showed positive response on lung function and methacholin provocation test. We performed environmental survey with 15 and 10 cases during May and June 2007, respectively. There was no significant difference between the case and control groups in the level of formaldehyde and TBC (Total Bacterial Count). In the dust allergen test, the case concentration was higher than the control's, without signifiant difference. In the personal exposure assessment of VOCs using OVM (Organic Vapor Monitor) badge, the case concentrations of Benzene, Toluene, and Ethylbenzene were higher than the control's, but there was no significant difference. The personal exposure of Xylene case study was significantly higher than the control's
        4,900원
        6.
        2015.10 서비스 종료(열람 제한)
        In the current concrete structure of the highway is still the major problem most of concrete deterioration caused by the freeze-thaw and de-icing salt, which is of issues that are not completely resolved. In particular, a single freezing event does not cause much harm, durability of concrete under multi-deterioration environment by repeated freeze-thaw and de-icing salt is rapidly degraded and reduce its service life. In this study, to considering environmental characteristics when design and construction of concrete structures, the exposure environmental guidelines were established by investigation the application rates of de-icing salt, temperatures and snowfall characteristics during five years (2004∼2008) by regions. Also, damage condition and chloride content of the structural at regions of moderate and severe environmental exposures were investigated.
        8.
        2001.02 KCI 등재 서비스 종료(열람 제한)
        This study examined blends of styrene butadiene rubber(SBR) and chloroprene rubber(CR) prepared from an open 2-roll mill following the conventional polymer blend method for a wide range of the blend composition. Rubber vulcanizates were manufactured by hot press and then mechanical properties, heat and ozone resistance of the specimens were examined. Due to the post cure during the aging test, hardness of vulcanizates was increased. It was found that the undesirable characteristics of heat and ozone resistance of pure SBR was significantly improved through the blending of SBR with CR.
        9.
        1999.06 KCI 등재 서비스 종료(열람 제한)
        This study was designed to evaluate the exposure to benzene by residents in neighborhoods near a major roadways, by persons waiting buses, and by drivers and service station attendants while refueling. It was confirmed that the outdoor air benzene concentrations near the major roadways were higher than those further away from the sources. However, neither the indoor air nor breath concentrations were different for two specified residential areas. Smoking was confirmed as an important factor for the indoor air benzene levels. Persons waiting buses, drivers and service station attendants were exposed to elevated benzene levels compared to even the residents in neighborhoods near a major roadways. The mean benzene concentration at bus stop was 2.7 to 6.9 times higher than the mean ambient air concentration. The mean benzene concentrations in the breathing zone of drivers and service station attendants were 95 to 160 and 120 to 202 times higher than the mean ambient air concentrations, respectively.