During indoor air conditioning, cold condensate is generated. But until recently, this condensate has not been recycled. This experiment and research is on the technology of the condensed water recycling in air conditioning. This study demonstrates the effect of condensate recycling, contributes to energy saving and water use reduction. For this purpose, the test equipment was installed to measure the temperature of the condensate generated in the fan-coil unit, and the performance of the high-pressure pump to be applied to the cooling pipe was examined. As a result, the water quality and energy saving effect.
본 연구에서는 대공간을 갖는 건물 및 중대형 시설하우스의 에너지절약 문제를 해결하고, 거주 인원 및 생육작물의 적합한 냉난방 환경을 제공하기 위해서 높이 가변형 4방향 팬코일 유니트(Fan Coil Unit)를 개발하였다. 이를 위해 높이 가변형 4방향 FCU의 개발에 있어서 높이 변화에 따른 4방향 FCU의 열유동 해석 연구수행과 FCU 케이스와 구조물에 대한 디자인 개발 및 개발대상제품의 정밀한 높이제어와 온도조절기능을 갖는 제어알고리즘의 연구 및 제어기 개발을 수행하였다. 따라서 기존 고정식 팬코일 또는 공조설비에서 나타나는 공조불균형 문제를 이동식(가변형)으로 신규 개발, 적용 하여 거주인원 및 생육작물의 근처에서 공조를 실시함으로써 공조불균형을 확실히 해소할 수 있을 것이다.
본 연구에서는 이미 보고된 잉여 태양에너지 관련 연구결과와 현재 현장에 설치되어 있는 냉난방용 FCU 현황을 개략적으로 검토한 후, 잉여 태양에너지 회수에 필요한 FCU의 소요대수 결정 방법을 개략적으로 제시하여 앞으로 이 분야의 연구자 및 기술자들에게 기조자료를 제시할 목적으로 연구를 수행하였다. 실험기간 동안 최대, 평균 및 최저 외기온은 각각 28.2oC, 4.4oC 및 -11.5oC정도였다. 온실 밖의 수평면 일사량은 0.8~20.5MJ·m-2로 정도의 범위였으며, 평균 및 총 일사량은 10.8MJ·m-2 및 1,187.5MJ·m-2으로 나타났다. 그리고 주간동안 온실 내의 평균기온과 상대습도는 각각 18.8~45.5 및 53.5~77.5%정도였다. 실험기간 동안 온실로부터 회수한 총 잉여 태양에너지는 6,613.4MJ정도로서 총 난방에너지인 98,600.2MJ 약 6.7%정도를 보충할 수 있을 것으로 나타났다. 또한 사양이 유사한 FCU를 사용하지만, 난방을 위하여 설치되는 FCU의 대수는 제각각 다른 것을 알 수 있었고, 좀 더 효율적이고 경제적인 관점에서 설치높이, 방향 및 설치 간격, 적정 대수에 대한 연구가 이루어져야 할 것으로 판단된다. 잉여 태양에너지 회수용 FCU의 적정 소요대수는 FCU를 통과하는 공기의 질량 및 순환유량을 기준으로 각각 8.4~10.9대 및 6.1~8.0대 정도이었다. 여기에 계산방법이나 FCU의 효율 및 사용 환경 등 위험률을 고려하면, 결국 9대 전후(약 24m3당 1대 정도)를 설치하면 될 것으로 판단되었다.
본 연구는 히트펌프와 잉여 태양에너지를 이용한 온실의 난방효과를 검토하고, 난방을 위한 FCU(Fan Coil Unit)의 적정 소요대수를 검토하였다. 실험기간 동안 최저 및 평균 외기온은 각각 26.2℃, –11.5℃ 및 4.4℃정도이었고, 수평면 일사량은 0.75~20.54 MJ·m-2 정도의 범위에 있다. 이 기간 동안 온실로 부터 회수된 총 잉여 태양에너지는 1,579,884.9kcal 정도로 나타나 이상화탄소 배출량을 약 470.3 kgCO2정도 절감시킬 수 있을 것으로 나타났다. 그리고 히트펌프 작동에 의해 축열탱크에 축열된 총 열 량은 26,556,903.6kcal로 이산화탄소의 발생량을 8,366.2 kgCO2정도 절감시킬 수 있는 것으로 나타났 다. 히트펌프에 의해 축열된 총 열량 중에 잉여 태양에너지에서 얻은 열량의 비율은 최소 0.0%, 최대 20.9%, 평균 6.1%정도로서 기상상태나 히트펌프 작동상태 등에 따라 큰 차이가 있었다. 히트펌프 시스 템의 성능계수와 히트펌프의 효율은 각각 약 2.64정도 및 약 86.6%전후인 것으로 나타났다. 또한 총 난방에너지는 23,554,744.7kcal으로서 실제 히트펌프에 의해 축열탱크에 축열된 량의 약 88.7%정도를 이용하는 것으로 나타났다. 시간당 전체 난방에너지는 10,993.1~18,786.9kcal·h-1범위였고, 평균 14,381.3kcal·h-1이로서 대부분 난방부하보다 많은 것으로 나타났다. FCU는 대당 1,597.9 kcal·h-1 전후의 값이나 5.0~6.0m2당 1대 정도로 설계하면 큰 문제가 없을 것으로 추정되었다.
Experimental hot-water heating system was consisted of power supply equipment, a hot water storage tank, circulating pump, fan coil unit and a plastic flexible hose. This heating system was manufactured by an electric heater of a power capacity 6kw/h and light-oil hot air heater in control the heating capacity was 5,000kcal/h. As the result, temperature difference due to hot-water heating system and hot air heater in greenhouse showed that air temperature at experimental greenhouse, and comparison greenhouse were 14.8℃, 13.4℃ respectively. It was found that root-zone temperature of experimental plot and control were 22℃, 15℃. Root-zone temperature in the experimental plot was 7℃ higher than that in control. The inlet-outlet water temperature difference of 2℃ and 3℃ corresponded to the difference of the heat exchange of about 3,132kcal/h, 4,916kcal/h, the heat exchange effciency ranged from 54~88% generally. Under the experimental condition, equation heat change(Y) and correlation could be represented as follows : Y = -282.92x2 + 2963.9x -1688.6, R2 = 0.9081. it is suggested to applicate energy of root-zone warming system where energy from the groundwater is extracted and transferred to the water
본 연구는 길이 15 m, 폭 5.6 m, 동고 2.9 m인 단동 비닐 온실 2동을 대상으로 실험구와 대조구로 나누어 실시하였다. 시스템은 전기히터를 이용한 온수가온기로서 온수저장조와 순환펌프, 팬코일유닛으로 구성하였다. 폐회로시스템의 온수배관을 통하여 온수가 순환되도록 하였으며 팬코일유닛을 통해 온실내부를 난방 하도록 하였다. 연구결과를 요약하면 다음과 같다. 실험기간 동안 순환유량은 26L/min 정도의 범위에 있었고, 평균유속은 2.0m/s 정도였다. 유출입수의 평균 온도차는 60±2℃ 이었다. 근권부 온도를 측정한 결과 처리구에는 22℃, 대조구에서는 15℃로 나타나 처리구 근권부 온도가 약 7℃ 높게 유지되었다. 입출구 온도차에 따른 열교환량은 온도차가 2℃일 경우 시간당 열교환량은 3,132kcal이고, 3.4℃일 경우 4,916kcal로서 열교환방정식은 y=-282.92X2+2963.9X-1688.6, R2=0.9081로 상관관계가 매우 높은 것으로 나타났으며 열교환효율은 54~88%로 온도차가 클수록 열교환효율은 높게 나타났다.
This study is nutrient heating effect to apply the surplus heat recovery in greenhouse using fan coil unit. Especially, this study was carried out to utilize a surplus heat in greenhouse. This fan coil unit system was composed of a water tank, a fan coil unit, a circulating pump and a water-water heat exchanger. As the result, Temperature difference duing to fan coil unit in greenhouse showed that air temperature at experimental greenhouse on fan , comparison greenhouse were 28.3℃, 33.9℃, respectively. heat ratio showed that exchanged energy quantity in fan coil unit was 19,900∼28,880kcal/h, respectively. It was found that difference of nutrient temperature due to surplus heat recovery, water tank temperature were 19.2∼21.5℃ and 16.2∼18.3℃, The temperature variation of nutrient temperature was about 3℃ and higher . Economic analysis of fan coil unit system was increased gross income cost by 804,787 won.
이 연구에서는 선박용 팬일유니트의 엇갈림 냉각관 주위 유동특성을 실험적으로 고찰하였다. 입자영상유속계를 이용하여 입구유속기준 레이놀즈수 Re = 1.5×103에서 Re = 2.5×103까지 계측결과를 얻었다. 그 곁과 유동은 흐름방향으로 빠른 속도로 발달하여 비교적 짧은 거리 후방에 공간적인 주기성을 나타내었다. 유동이 발달하는 영역에서는 레이놀즈수에 의존하는 경향이 크게 나타났으나 공간적 주기성에 미치는 레이놀즈수의 영향은 크지 않았다.