검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 33

        1.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The temperature distributions were numerically calculated for the two-dimensional transient conduction heat transfer problem of a square plate. The obtained temperature distributions were converted into colors to create images, and they were provided as learning and test data of CNN. Classification and regression networks were constructed to predict representative wall temperatures through CNN analysis. As results, the classification networks predicted the representative wall temperatures with an accuracy of 99.91% by erroneously predicting only 1 out of 1100 images. The regression networks predicted the representative wall temperatures within errors of C. From this fact, it was confirmed that the deep learning techniques are applicable to the transient conduction heat transfer problems.
        4,000원
        2.
        2017.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The heat transfer of Jet impingement is a very effective technique for exchanging high heat fluxs between a heated plate and a fluid. The purpose of current investigation is to carry out the experiment in order to study heat transfer characteristics between a vertical round water jet and a horizontal surface for different flow rates and geometric conditions. The effect of flow rates on heat transfer were investigated. The data obtained in this study are represented in terms of Nusselt number as a function of Reynolds and Peclet numbers. The correlation for the Nusselts number in terms of the Peclet number and  was obtained. The proposed correlation predicts the current data of heat transfer very well.
        4,000원
        3.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, temperature variation characteristics in a flat plate with sheath heater are investigated through experiment and numerical analysis. ANSYS fluent is used to calculate the temperature distribution in the heating plate system. Transient condition is applied to observe temperature variation with the sheath heater operation, and thermal resistance on the contacted surfaces is also considered. Experimental data agree well with numerical results obtained for heat generation rate from sheath heater, Local temperature variation on the surface of flat plate is also predicted through this simulation. There is large temperature variation in the air surrounded flat plate, especially at the top of flat plate with natural convective heat transfer. These results will be helpful in optimal design for various systems equipped with sheath heater.
        4,000원
        4.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        불확실성을 가지는 콘크리트의 특성으로 인해 철근 콘크리트 부재의 처짐에는 높은 변동성이 발생할 수 있다. 그러나 현행 설계규준은 이를 고려하지 않고 경험적인 데이터에 바탕을 두고 있으며, 부재의 최소 두께 또는 최대 허용 처짐만을 제시하고 있다. 본 논문에서는 철근 콘크리트 플랫 플레이트의 처짐 예측이 가능한 유한요소해석 모델에 확률해석 모델을 적용하여 철근 콘크리트 플랫 플레이트 처짐의 변동성을 평가하고자 하였다. 이를 위해 콘크리트, 철근, 부재치수, 인장강성에 관련된 8개 요소를 변수로 한 몬테카를로 시뮬레이션을 수행하였다. 해석결과, 스팬의 크기가 증가할수록 하중으로 인한 처짐에 더 민감하게 반응하는 것으로 나타났으며, 재하되는 활하중의 크기가 클수록, 슬래브의 두께가 작을수록 처짐의 변동성이 큰 것으로 나타났다.
        4,000원
        5.
        2014.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 유공형 형상의 GFRP 판으로 전단 보강된 플랫 플레이트의 전단거동을 실험을 통해 평가하였다. GFRP 판은 개구부가 있는 판의 형태로서 콘크리트와의 일체화 거동을 위하여 콘크리트에 매립하여 시공하였다. GFRP 판으로 전단보강된 플랫 플레이트의 전단 성능 실험을 위하여 총 7개의 시험체에 대한 전단 실험을 수행하였다. 실험 변수로는 전단 보강량, 전단 보강 간격을 선정하였다. GFRP 판의 전단 보강량에 따른 비교결과, 전단 보강량이 증가할수록 전단강도도 증가하는 결과를 보여주었다. GFRP 전단 보강 간격에 따른 비교결과, 전단 보강 간격이 0.3d 일 때 가장 높은 전단강도를 확인하였다. 실험결과를 바탕으로 KCI에서 제시하고 있는 전단강도식을 수정하여 GFRP 판에 적용이 가능한지 평가하였다.
        4,000원
        6.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 유공형 형상의 GFRP 판으로 전단 보강된 플랫 플레이트의 전단거동을 실험을 통해 평가하였다. GFRP 판은 개구부가 있는 판의 형태로서 콘크리트와의 일체화 거동을 위하여 콘크리트에 매립하여 시공하였다. 실험 변수로는 기둥면과 첫 번째 GFRP 판의 세로 스트립 사이의 간격, GFRP 판의 세로 스트립의 개수를 선정하였다. GFRP 판의 세로 스트립의 개수가 증가할수록 전단강도도 증가하는 결과를 보여주었다. 실험결과를 바탕으로 GFRP 판으로 보강된 플랫 플레이트의 전단강도가 ACI 318, BS 8110, EUROCODE 2, KCI에서 제시하고 있는 전단강도와 비교하여 가장 합리적인 규준을 평가하였다.
        4,000원
        7.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Main topics in this study is a new structural detail for connection between H-Steel or SRC column and flat plate slab. We carried out to evaluate the punching shear performance of H-steel or SRC column + RC slab system for vertical load and lateral load. From the test results structural characteristics - yield moment, yield rotation, maximum moment, deformation capabilities ect. - are obtained and evaluated. In this paper as a shear reinforcement for supporting region of plate closed stirrup type and shear band are used, and their test results are compared.
        4,000원
        8.
        2014.04 구독 인증기관·개인회원 무료
        An experimental study was carried out to evaluate the punching shear performance of H-steel column + RC slab system for vertical load. Three specimens were constructed for interior column-slab system. All specimens were the same configuration and material properties except for columns such as RC column+flat plate slab and H-Steel column+flat plate slab. From the test results structural characteristics (maximum proof stress, maximum displacement, deformation capabilities and so on) are obtained and evaluated.
        9.
        2014.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The flat plate slab system have many good features, which are design flexibilities, saving of story-height and economy of construction etc. But the study of flat plate slab system for H-steel column have been rare both at home and abroad. Recently high-rise residential and commercial buildings have been constructed in urban areas in Korea. The suggested dowel connection system is more likely to adoptable because it remarkably contribute to save inter story height and also to have many advantages compared with conventional steel works such as H-Steel frame + Deck plate slab system. This study aims at developing design method and program for connection between H-Steel column and flat plate slab system, which contribute to save significantly inter-story height.
        4,000원
        10.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        An experimental method, based upon wall visualizations, has been developed to observe air flow near a plane wall around a row of five 45° inclined jets discharging into a cross stream. This study concerns the variation of injection rate R which is one of the most important parameters governing this flow type. The Results are concentrated on the spatial evolution of two lobes with R. These structures are fastened to jets downstream edge and exist for very low injection rate values which are an indication of jets takeoff at the immediate downstream of injection orifices. The velocity rate of 0.42 marks a change in the structure alimentation system.
        4,000원
        11.
        2011.04 구독 인증기관 무료, 개인회원 유료
        The conventional RC flat plate slab system have many good features, which are design flexibilities, saving of story-height and economy of construction etc. But the study of flat plate slab system for H-steel or SRC column have been rare both at home and abroad. Main topics in this study is a new structural detail for connection between H-Steel or SRC column and flat plate slab. The test for lateral performance of connection between H-Steel or SRC column and flat plate slab was carried out. From the test results structural characteristics - yield moment, yield rotation, maximum moment, deformation capabilities and so on - are obtained and evaluated.
        3,000원
        12.
        2010.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 기둥을 관통하는 슬래브 하부 철근이 중력하중만으로 설계된 포스트텐션 플랫플레이트 골조의 내진성능에 미치는 영향을 평가하였다. 중 약진 지역에서 건물은 흔히 중력하중만을 고려하여 설계되고 있다. 본 연구에서는 중력하중으로 설계된 PT 플랫플레이트 골조의 내진성능에 집중되고 있다. 이를 위하여, 3,6,9층 PT 플랫플레이트 골조는 중력하중만으로 설계하였다. 철근콘크리트 플랫플레이트 골조에서는 취성적인 붕괴를 예방하기 위해서는 기둥을 관통하는 연속된 슬래브 하부철근이 위치하여야 한다. 그러나 PT 플랫플레이트 골조에서는 슬래브 하부 철근에 대해 ACI 318-05에서는 특별한 언급이 없기 때문에 흔히 생략하고 있다. 본 연구는 대산건물을 비선형 시간이력해석 으로 골조 모델의 내진성능에 대해 평가한다. 비선형 시간이력해석은 6개의 지진과 2개의 다른 위험수준 (475, 2475년 주기), 3개의 다른 지역 (보스턴, 시애틀, LA)을 사용하였다. 해석모델은 PT슬래브-기둥 접합부의 파괴 메카니즘과 비선형 거동을 살펴보기 위해 개발되었다. 본 연구는 중력하중으로 설계된 PT 플랫플레이트 골조가 몇몇 내진저항 능력을 보여주고 있다. 또한, PT 플랫플레이트 골조의 내진성능은 기둥을 관통하는 슬래브 하부철근이 위치할 때 눈에 띄게 향상되었다.
        4,000원
        13.
        2009.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Indoor Lighting can be improved by using a refractive lens. This lens is a flat-plate, and patterns are engraved on its surface. The engraved patterns are designed to refract sun's rays. In this study, two patterns have been suggested. The one is designed to refract sun's rays in one direction. The another is designed to refract sun's rays in 4 directions. The designed patterns were machined with a diamond tool and engraved on an experimental Poly Methyl Meta Acrylate flat-plate. Optical experiments have been done by using a laser rays and natural sun's rays. The results showed that sun's rays refracted in one or 4 directions effectively. The refracted rays also improved indoor lighting.
        4,000원
        14.
        2008.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 중 약진 지역에서 중력 저항시스템인 중간 모멘트골조로 설계된 3층, 6층 RE 플랫플레이트 구조물을 KBC 2005를 만족하도록 RC구조물에 강판과 가새/ BRB 등의 보강방법을 적용하여 보강하고, 내진성능을 평가하여 보강 효과를 검증하였다. 비탄성 정적해석과 동적해석 결과에 따르면 내진 보강된 구조물은 강도와 강성이 크게 향상된 것으로 나타났다 특히 기둥을 철판으로 보강한 경우 슬래브를 철판으로 보강하여 조기 뚫림 전단파괴를 방지함으로써 강도를 크게 향상할 수 있다. BRB로 보강된 구조물은 Brace로 보강된 구조물보다 다소 연성적 거동을 보였으며, 그 효과는 3층 모델에서 현저하게 나타났다.
        4,000원
        15.
        2008.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 슬래브 하부철근이 포스트 텐션(PT) 플랫 플레이트 골조의 내진성능에 미치는 영향을 평가하였다. 이를 위하여 슬래브-기둥 접합부에 슬래브 하부철근이 있는 경우와 없는 경우의3층, 9층 골조를 중력하중만 고려하여 설계하였다. 본 연구에서는 대상 건물을 비선형 정적 푸쉬오버 해석하여 기둥을 관통하는 슬래브 하부철근 유무에 따른 전체 구조시스템 거동을 평가하였다. 본 연구에서 사용한 접합부 모델은 뚫림 전단과 파괴메커니즘을 예측할 수 있도록 본 연구자들에 의하여 기존 연구에서 제안된 것이다. 본 연구 결과에 따르면 슬래브 하부철근은 PT 플랫 플레이트 골조의 내진성능에 큰 영향을 미치는 것으로 나타났다. 특히 슬래브 하부 철근이 있는 PT 플랫 플레이트 골조는 슬래브 하부철근이 없는 골조에 비하여 최대 강도와 변형 능력이 크게 향상되었다.
        4,000원
        16.
        2008.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The object of this study is to investigate the penetration characteristics according to the change of stacking sequences and curvature radius in the composite laminated shell. They are staked to [02/902]S and [0/902/0]s, their interlaminar number are two and four. We are manufactured to composite laminated shells with various curvature radius. Curvature radius of composite shell is 100, 150, 200mm and ∞(it's meaning flat-plate). In general, kinetic energy after impact-kinetic energy before impact increased linearly in all specimens. Absorbed energy increased linearly as the curvature increased, and absorbed energy of [02/902]S specimen, which is small interlaminar number, was higher than [0/902/0]s specimen.
        4,000원
        17.
        2007.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 PT 플랫 플레이트 골조의 내진성능을 평가하기 위하여 비선형 거동을 예측할 수 있는 해석모델을 개발하였다. 특히 본 연구에서 개발한 해석 모델은PT 플랫 플레이트 슬래브-기둥 접합부에서 기둥을 관통하는 철근이 있는 경우와 없는 경우의 접합부 거동을 정확하게 예측할 수 있도록 개발하였다. 또한 본 연구에서 개발한 접합부 해석 모델은PT 플랫 플레이트 슬래브-기둥 접합부에서 뚫림 전단 파괴가 발생하는 때를 정확하게 예측하도록 하였다. 개발한 해석 모델의 타당성을 검증하기 위하여PT 플랫 플레이트 슬래브-기둥 접합부 실험결과와 해석 결과를 비교하였다. 또한 2층 PT 플랫 플레이트 골조의 진동대 실험결과와 해석결과를 비교하였다. 본 연구에서는 기둥을 관통하는 철근이 있는 접합부와 없는 접합부를 갖는 2층 PT 플랫 플레이트 골조를 세 가지의 크기로 조정한El Centro 지진에 대하여 비선형 동적 해석을 수행하였다. 지진의 크기가 커지면 하부 철근이 없는 골조의 요구 변위와 잔류 변형이 하부 철근이 있는 골조에 비하여 더욱 커지는 것으로 나타났다.
        4,000원
        18.
        2003.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        근래에 들어서 경제적 및 계획적인 요구에 의하여 충고를 줄일 수 있는 이점을 가진 플랫플레이트 구조물이 많이 건설되고 있다. 구조기술자들은 실무에서 플랫플레이트 구조물을 해석하기 위하여 일반적으로 유효보폭모델을 사용한다. 그러나 유효보폭 모델을 적용하기가 어려운 경우에는 유한요소법을 사용할 필요가 있으며, 이때 바닥판의 정확한 거동을 예측하기 위해서는 세분한 유한요소 모델을 사용하는 것이 필요하다. 전체 구조물을 수많은 유한요소로 세분하여 모형화하면 막대한 해석시간과 컴퓨터 메모리가 필요하게 된다. 따라서 본 연구에서는 상당히 정확한 해석결과를 쉽게 얻을 수 있는 효율적인 해석기법을 제안한다. 제안된 해석기법은 행렬응축기법을 통하여 생성된 수퍼요소를 사용하며 수퍼요소 경계부분의 변형적합조건을 만족시키기 위하여 수퍼요소를 개발할 때 가상보를 도입한다. 본 연구에서는 슬래브의 탄성계수를 감소시킴으로서 유효보폭모델에서 사용되고 있는 강성저감을 고려하였다. 수많은 요소론 사용한 유한요소모델 및 유효보폭모델을 사용하여 여러 가지의 예제구조물에 대하여 정적해석과 동적해석을 수행하고 본 연구에서 제안된 해석방법에 의한 결과와 비교함으로써 제안된 방법의 효율성과 정확성을 검증하였다.
        4,300원
        19.
        2003.02 구독 인증기관 무료, 개인회원 유료
        Cracking of slabs will be caused by applied load and volume changes during the life of a structure and thus it reduces flexural stiffness of slabs. The effect of slab cracking must be considered for appropriate modeling of the flexural stiffness for frame members used in structural analysis. Analytical and experimental study was undertaken to estimate the stiffness reduction of slabs In the analytical approach, the trend of slab stiffness reduction related to gravity and lateral loads is found and the stiffness reduction factor ranged from a half to a quarter in ACI building code is reasonable when defining range. Analyzing results of the test by Hwang and Moehle for 0.5% drift show that the differences of rotational stiffness on the connection types is found and good results of lateral stiffness using the value of one-third is obtained. To evaluate the stiffness reduction factor of one-third for residential building in domestic regions, the test is performed
        4,000원
        20.
        1998.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        평판디스플레이용 진공패널의 제작시 진공으로 유지된 패널을 구성하는 유리판이 받는 응력과 변위를 계산하였다. 유리판의 두께, 패널의 크기 및 실링폭의 크기를 변수로 하여 실제로 진공패널을 제작한 후 패널의 파괴양상과 변위를 측정하였다. 유리판의 파괴양상과 변형측정을 통하여 유리판에 걸리는 최대응력은 테두리부분에 걸리는 것을 확인하였다. 제작된 진공패널이 갖는 응력분포 및 변위의 분포는 패널을 진공실링할 때 사용한 실런트의 폭에 크게 의존하였다. 패널의 실링폭이 커질수록 모서리가 완전 고정된 조건으로 계산한 결과와 유사하였다. 두께가 3mm인 유리판을 사용해서 80×120textrmmm2</TEX> 크기의 패널을 제작할 때 실링폭이 20mm인 경우 측정된 변위는 57μm였으며, 이 값은 모서리가 완전히 고정된 조건으로 계산한 갈인 54μm와 비슷하였다.
        4,000원
        1 2