검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 361

        102.
        2015.12 KCI 등재 구독 인증기관·개인회원 무료
        Pulpose : Although diffusion tensor imaging (DTI) has been widely used for the quantitative analyses of the integrity of white matter in the brain in clinical and research fields, quality assurance (QA) for DTI has not been fully established. The purpose of this study suggests a QA guideline for DTI using the American College of Radiology (ACR) Magnetic resonance imaging (MRI) head phantom. Materials and Methods : All experiments were performed using 1.5T and 3.0T scanners (InteraAchiva 1.5T and AchivaTx 3.0T; Philips Medical Systems, Netherlands) equipped with an 8-channel SENSE head coil. The standard axial SE T1-weighted MR images with 6, 15 and 32 directions of DTI were obtained using the standard scanning protocol “Phantom Test Guidance for the ACR MRI Accreditation Program” . Slice thickness and slice gap were set at 5 mm for standard axial SE T1 images and echo planar images, and then both images were compared. Reproducibility was tested with 7 repeat scans in 1.5T scanner and 10 repeat scans in 3.0T scanner. Between the scanning, the ACR MRI phantom was completely removed from coil and was repositioned for each new trial. Parameters for the QA protocol are shown in Table 1. The ACR MRI phantom was stored in the scanner room for at least 24 hours before an experiment, and the room temperature was measured before scanning for DTI. Results : There were statistically significant differences in the geometric accuracy between the 1.5T and 3.0T two scanners across all scan directions. The top-to-bottom diameters had a 11.3 mm error in 1.5T scanner and a 7.2 mm error in 3.0T scanner. Image intensity uniformity tests were significant in 6, 15, and 32 directions at 1.5T and 3.0T comparative analysis (p < 0.001). Additionally, percent signal-ghosting tests were significant in all directions, such as 6, 15 and 32 directions, in both 1.5T and 3.0T scanners (p < 0.001). The DTI images from 1.5T scanner had a ghosting ratio less than 0.025 at 1.5T scanner while 3.0T scanner had a ghosting ratio greater than 0.045. The low-contrast object detectability had a significant differences in 6, 15, 32 directions at 1.5T and 3.0T systems (p < 0.001). The DTI images from 1.5T system showed 2.85 spokes in 6 directions, 14.00 spokes in 15 directions, and 26.14 spokes in 32 directions. The DTI images from 3.0T system had 7.80 spokes in 6 directions, 32.20 spokes in 15 directions, and 37.30 spokes in 32 directions. Image distortion was significant in the anteriorposterior (AP) direction (p <0.001), but was not significant in right-left (RL) direction (p = 0.359). Image distortions in 1.5T scanner were 6.93 mm for the AP direction and 0.26 mm for the RL direction while the same for 3.0T system were 8.55 mm for the AP direction and 0.28 mm for the RL direction. For the FA and the ADC values, we acquired significant results in 6, 15, and 32 directions for 1.5T and 3.0T scanners (p < 0.001). The FA values were relatively lower for 3.0T system than for 1.5T system, and 32 directions for 3.0T scanner had the lowest value. The ADC values of 3.0T system were lower than those of 1.5T system, and 15 and 32 directions had the lowest values. Conclusion : This study is the first trial using the ACR MRI phantom that is easily accessible in most clinical MR centers. Also, the present study using the ACR MRI phantom suggests a QA method for DTI with high reproducibility and easy accessibility.
        103.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 의료영상평가의 특성상 전문가의 정성적인 평가에 의존함에 따른 비용과 시간의 제약에 대한 문제점을 해소하고자 본 연구에서는 MR 확산 텐서 영상에 Compressed sensing 기법을 적용하여 복원한 영상과 원본 영상과의 정확도를 정량적으로 평가하기 위하여 fiber tract을 수치적으로 나타낼 수 있는 변수들의 상관관계를 분석하여 정량적 평가 방법의 기준을 제시하고자 한다. 대상 및 방법 : 2014년 3월부터 5월까지 본원에 내원한 환자 중 평균 나이 53.8 ± 15세(남성 3명, 여성 2명)의 뇌 질환이 의심되는 환자들에 대해 3.0T MRI(Archiva, Philips medical system, Netherlands)를 사용하여 뇌 MR 확산 텐서 영상을 얻었다. 획득한 원본 확산 텐서 영상들은 Compressed Sensing기법을 이용하여 under-sampling 후 영상복원의 정도(reduction factor)를 달리하여 재구성하였다. 각 신경 섬유 다발 영상들의 Fiber statics를 분석하여 신경 섬유의 총 개수, 한 단위 복셀 당 신경 섬유의 개수, 확산 텐서 영상에서 비등방성을 나타내는 고유의 값인 FA, RA, VR값과 평균 확산 계수(Mean Diffusivity), Radial Diffusivity, Eigen Value, Tensor Trace로 총 9개의 변수 값을 구하였다. 정성적 분석은 영상의학과 판독의 1명, 5년 이상 MRI 근무 경력이 있는 방사선사 4명에게 원본 영상과 비교하여 보았을 때 복원 영상이 진단적 가치가 있는지를 매우 양호하지 않다(1), 양호하지 않다(2), 보통(3), 양호하다(4), 매우 양호하다(5)의 항목으로 나누어 각각의 영상에 대하여 설문 조사를 하였다. 정성적 분석 결과와 변수들의 값을 회귀 분석을 통해 상관관계를 분석하여 식을 도출하였다. 결 과 : 25개의 training/test dataset에 대한 각 변수에 대한 가중치들을 회기 분석하여 구한 값을 통해 구한 test dataset의 정량적 분석과 전문가 집단의 정성적 분석과의 오차는 평균 19%를 보였으며 이 가중치 값들을 바탕으로 뇌 MR 확산 텐서 영상의 고속화에 다른 정확도를 정량적으로 평가하기 위한 방법의 식을 얻을 수 있었으며 평균 11%의 오차율을 보였다. 또한 sample data 수를 증가하여 결과를 예측해 보기 위하여 붓스트랩을 적용하여 15개의 복원된 뇌신경 섬유 영상의 원본과의 차이를 나타낸 변수 값들의 데이터를 training set으로 정하여 410개의 sample data를 바탕으로 구해진 가중치들의 값을 통해 얻은 식은 평균 7%의 오차율을 보였다. 결 론 : 전문가들의 정성적 평가에서 5명 모두 동일한 의견을 나타냈을 때는 8%에 지나지 않았으며 각 영상의 정성적 평가 평균값과 다른 의견을 보인 전문가들의 오차율은 평균 36%였다. 따라서 본 연구의 11%와 7% 오차율은 전문가들 중에서 이견을 보일 수 있는 오차율 보다 작아 허용 가능한 범위에 있는 것으로 보이며 이 두 식은 정확도를 평가하는 데 있어 정성적 평가방법을 충분히 대체할 수 있을 것으로 보인다. 하지만 정량적 평가의 정확도를 좀 더 높이기 위해서는 오차를 줄이기 위해 더 많은 training/test dataset의 실험을 추가하여 개선해 나아가면 될 것으로 보인다.
        4,000원
        104.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 신생아 혹은 미숙아의 뇌 MRI 검사 시 임상에서는 성인과 동일한 protocol을 사용하여 검사하고 있다. 하지만 신생아의 뇌는 성인과 달리 수초화가 완성되지 않아 물의 함량은 많고 단백질과 지질의 함량은 적어 각 조직의 T1 값이 성인보다 길다. 따라서 신생아의 뇌 특성을 고려한 최적의 T1 강조영상을 얻기 위해서는 기존에 적용되는 성인 TR: 450ms와 다른 적절한 TR 값이 요구된다. 이에 본 연구에서는 신생아 뇌 MRI 검사 시 진단가치 높은 T1 강조영상을 획득할 수 있는 최적의 TR 값을 찾고자 하였다. 대상 및 방법 : 신생아 중환자실에 입원한 생후 3개월 미만의 신생아 혹은 미숙아 총 10명(남6명, 여4명)을 대상으로 2014년 10월부터 2015년 1월까지 검사를 진행하였다. 장비는 1.5T Avanto (SIEMENS, Germany), MR Diagnostics Incubator System과 신생아 전용 Head coil인 LMT coil을 사용하였다. 대상 신생아에서 모든 parameters는 동일하게 하고, 조직 간의 T1 회복시간 차이에 큰 영향을 미치는 TR 값만을 450, 900, 1200, 1500 으로 달리하여 각각의 영상들을 얻었다. 영상분석방법은 정성적 분석과 정량적 분석으로 하였다. 정성적 분석을 위해 영상의학과 소아판독 전문의 2명과 방사선사 3명이 촬영한 영상에 대해 백질(white matter)과 회백질(gray matter)의 구별정도, 병변의 식별정도, Artifact, 전체적인 image quality에 관해 5 point scale (0=very poor, 1=poor, 2=fair, 3=good, 4=excellent)로 평가하였으며, 정량적 분석으로 신생아의 백질과 회백질 그리고 background의 신호강도(Signal intensity: SI)를 측정하여 신호 대 잡음비(signal to noise ratio: SNR)와 대조도 대 잡음비(contrast to noise ratio: CNR)를 계산해 비교분석 하였다. 통계적 분석을 위해서 SPSS 22.0(SPSS Incorporated, Chicago, IL, USA) 프로그램을 사용하였다. 결 과 : 본 실험에서 450, 900, 1200, 1500 TR 값으로 얻어진 영상들의 결과이다. 각 TR에 따른 백질과 회백질의 평균 SNR은 12.81/15.06, 23.58/27.39, 28.16/32.32, 35.52/40.26 이다. 각 영상들의 백질과 회백질 평균 CNR은 0.225, 0.371, 0.391, 0.454 이다. 정성적 분석으로 각 영상들의 평균값은 1.4±0.66, 2.56±0.49, 2.88±0.55, 3.46±0.49 이다. 통계분석은 Kruskal-Wallis 검정과 Mann-Whitney의 U 검정을 이용한 사후검정에서 근사유의확률 0.000~0.005로서 통계적으로 유의미한 차이가 있는 것으로 나타났다. 결 론 : 일반적인 검사방법인 성인 protocol의 TR 값을 신생아 뇌 MRI 촬영 시 적용하여 T1 강조영상을 얻을 경우, 신호 대 잡음비(SNR)와 대조도 대 잡음비(CNR)가 감소해 해부학적 분별력과 병변의 식별능력이 저하되는 문제점이 있었다. 하지만, 신생아 뇌의 특성을 고려하여 기존의 TR 값보다 2배 이상의 값을 선택하여 영상을 얻는다면 기존보다 향상된 SNR과 CNR을 가진 영상으로 신생아의 뇌 질환을 진단하는데 유용할 것으로 사료된다.
        4,000원
        105.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A 4-day-old, male Poodle dog was presented with dull, depressed and exhausted activity after the birth. On physical examination, the puppy showed arthrogryposis, muscular atrophy and no movement of hindlimbs. Palpation on dorsum revealed an absence of lumbar and sacral vertebrae. On prenatal and postnatal radiography, lumbar vertebrae, sacrum and coccygeal vertebrae were not visualized. On ultrasonography, bilateral kidney and urinary bladder were observed. On computed tomography, there were no apparent abnormalities in the forelimbs, cervical vertebrae or head, while lumbar vertebrae, sacrum and coccygeal vertebrae were not observed. At necropsy examination, the liver, stomach, intestine, kidney and urinary bladder were normal. This congenital anomaly was consistent with Perosomus elumbis. Perosomus elumbis in dogs is a rare condition of unknown etiology. In this report, Perosomus elumbis was evaluated with radiography, ultrasound and computed tomography.
        3,000원
        106.
        2015.11 구독 인증기관 무료, 개인회원 유료
        Because the lens is a tissue with the highest sensitivity, the lens shielding is very important in CT imaging. However, in clinical terms, there is a lack in the efforts in decreasing dosage on the lens, and the shielding of dosage and the effects on the imaging are researched using bismuth to evaluate the usefulness. As results of the dosage evaluation results, when there is no gantry angle when the thickness of the lens shielding material is 0mm, the dosage was 28.476mGy, and when there is gantry angle, the dosage was 20.852mGy that it was confirmed that the dosage was 27% lesser with gantry angle. It was confirmed that the dosage value decreased with the increase of thickness of lens shielding material when there is gantry angle, and when the lens shielding material was 1mm, the dosage decreased by approximately 39% compared to when it was 0mm. When there is gantry angle, the dosage values were respectively 12.788mGy and 12.776mGy for the crystalline lens shielding material thicknesses of 0.75mm and 1.0mm. In image analysis, the quantitative evaluation and the qualitative evaluation were almost constant regardless of the thickness of the lens shielding material. The optimal lens shielding material thickness to minimize the does of lens and increase the value of diagnosis in Brain CT examination is 0.75mm. Therefore, if this is utilized for easier use in clinical practices, it is considered to be able to contribute to not only the protection of the lens but the accurate diagnosis of diseases.
        4,000원
        110.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Korean very-long-baseline interferometry (VLBI) network (KVN) and VLBI Exploration of Radio Astrometry (VERA) Array (KaVA) is the rst international VLBI array dedicated to high-frequency (23 GHz (K-band) and 43 GHz (Q-band)) observations in East Asia. To evaluate the imagine capability of KaVA, we performed imaging observations of three bright active galactic nuclei (AGNs) known for their complex morphologies: 4C 39.25, 3C 273, and M87 by KaVA at K-/Q-band. Our KaVA images reveal extended out ows with complex substructure such as knots and limb brightening, in agreement with previous observations by other VLBI facilities. Angular resolutions are better than 1.4 and 0.8 milliarcsecond (max) at K-/Q-band, respectively. KaVA achieves a high dynamic range of ~1000, more than three times the value achieved by VERA. We conclude that KaVA is a powerful array with a great potential for the study of AGN out ows, at least comparable to the best existing radio interferometric arrays.
        3,000원
        111.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Muscular dystrophy is a hereditary musculoskeletal disorder caused by a mutation in the dystrophin gene. Duchenne muscular dystrophy (DMD) is one of the most common, and progresses relatively faster than other muscular dystrophies. It is characterized by progressive myofiber degeneration, muscle weakness and ultimately ambulatory loss. Since it is an X-linked recessive inheritance, DMD is mostly expressed in males and rarely expressed or less severe in females. The most effective measurement tool for DMD is magnetic resonance imaging (MRI), which allows non-invasive examination of longitudinal measurement. It can detect progressive decline of skeletal muscle size by measuring a maximal cross-sectional area of skeletal muscle. Additionally, other techniques in MRI, like T2-weighted imaging, assess muscle damage, including inflammation, by detecting changes in T2 relaxation time. Current MRI techniques even allow quantification of metabolic differences between affected and non-affected muscles in DMD. There is no current cure, but physical therapist can improve their quality of life by maintaining muscle strength and function, especially if treatment (and other forms of medical intervention) begins in the early stages of the disease.
        4,000원
        112.
        2015.05 구독 인증기관·개인회원 무료
        -To improve the performance of the conventional periodic δ-function arrays (PDFA) based computational integral imaging (CII), This paper propose a method of slice image reconstruction with controllable spatial filtering by using the correlation of PDFA with elemental images in CII. Methods- The multiple PDFAs are generated with spatial periods corresponding to object’s depths with the elemental image array (EIA). They are used to generate a set of spatially filtered-EIAs for multiple object depths. the intensity of the EIA can be represented as Eq. (1), ( ) ( ) ( ) 1 0 2 , 2 N O O O E E E O O O O O n O O O x f z P z P g x x n z f z x dx dz z f z f z d - = æ + ö = çç - - ÷÷ - è + + ø òòå . (1) Equation (1) implies that the intensity impulse response of an EIA is represented as a continuously distributed periodic function. The spatially periodic information corresponding to the targeting range of object’s depth can be extracted from an EIA by using the sifting property of convolution between periodic functions, and the equation is given by ( ) ( ) ( ) 2 1 , E E O E O R x g x s z x dz a a = - ò , (2) where α1 and α2 are the range of the depth for extracting spatially periodic information from the captured EIA and the given distance value. The later part of Eq. (2) can be given by ( ) ( ) 2 2 1 1 1 0 , 2 N O O O E O E O n O O NPf z P z P s z x dz x n dz z f z f a a a a d - = æ + ö = çç - - ÷÷ è + + ø ò ò å . (3) the results of Eqs. (2) and (3) imply that the depth information could be extracted from an EIA at the continuous or partially continuous ranges. This can be represented by ( ) ( ) ( ) ( ) 2 2 1 1 , , ... E E O E O O E O R x g x s z x dz s z x dz a b a b = - é + + ù êëò ò úû . (4) Therefore, Eq. (4) presents our controllable spatial filtering in the elemental images. Results- Figure 4 shows the spatial filtering result in the conventional method. Here, the single depth was considered as shown in Fig. 4(a). Then, the spatially filtered EIA has the only single clear object as shown in Fig. 4(b). Spatial filtering results according to required depth range from the EIA are shown in Fig. 5. Fig. 4. Spatial filtering used in the conventional method. Fig. 5. Spatial filtering used in the proposed method. Conclusions- In conclusion, a method of slice image reconstruction with controllable spatial filtering by using the correlation of PDFAs with elemental images in CII has been proposed. Since the multiple PDFAs had spatial periods correspond to object’s depths with the EIA, we could generate a set of spatially filtered-EIAs for multiple object depths. The proposed method was demonstrated for partially occluded object reconstruction experiments. Preliminary experiments reveal that our method can provide the control of depth range for spatial filtering selectively-
        117.
        2015.03 구독 인증기관 무료, 개인회원 유료
        Numerous experiments have demonstrated that infrared thermographic methods are effective for detection of subsurface defects in the materials. The response of the material to the thermal stimulus is dependent on the existence of subsurface defects and their features. In order to obtain the information about defects, the material’s response to the thermal stimulus is studied. In this study, image processing was applied to infrared thermography images to detect defects in metals that were widely used in industrial fields. When analyzing experimental data from infrared thermographic testing, thermal images were often not appropriate. Thus, four point method was used for processing of every pixel of thermal images using MATLAB program for quantitative evaluation of defect detection and characterization which increased the infrared non-destructive testing capabilities since subtle defects signature became apparent..
        3,000원
        118.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 신호대 잡음비는 자기공명영상 장치의 성능과 영상의 질을 평가하기 위한 객관적인 정보를 제공하는 중요한 척도이며 이를 측정하기 위한 많은 방법들이 제안되고 있다. 그 중 두 영역 측정방법은 측정방법이 간단하고 시간이 짧기 때문에 가장 흔히 사용되고 있다. 본 연구에서는 다중채널코일과 병렬영상기법 적용 시 두 영역측정방법에 의해 산출된 신호대 잡음비의 정확성에 대해 알아보고자 하였다. 대상 및 방법 : 장비는 Philips 3.0T MRI(Achieva, Philips medical system, Netherlands)과 transmit receive head coil, SENSE 8 channel head coil을 사용하였으며 MR sequence는 spin echo T1, T2 강조영상을 사용하여 축상면으로 ACR phantom 영상을 획득하였다. Transmit receive head coil을 사용한 두 영역 측정방법, AAPM, NEMA, Philips에서 제안한 측정방법, 다중채널코일과 병렬영상기법 적용 시 두 영역 측정방법의 신호대 잡음비 측정 조건에 따라 T1, T2 강조영상을 각각 30번씩 획득하였으며 Image J를 사용하여 각 영상의 동일한 위치에서 ROI 크기를 10 mm2으로 하여 신호대 잡음비를 측정하였다. 결 과 : T1 강조영상의 경우 AAPM에서 제안한 방법이 가장 균일한 신호대 잡음비를 나타내었으며 transmit receive head coil을 사용한 두 영역 측정방법과 NEMA는 10% 내외의 상대 표준 편차를 가짐으로써 균질한 값을 보였다. 하지만 다중 채널 코일과 병렬 영상 기법을 적용한 두 영역 측정방법의 경우 20% 이상의 상대 표준 편차를 보여 각 실험마다 신호대 잡음비의 큰 차이를 나타내었고 NEMA와 transmit receive head coil을 사용한 두 영역 측정방법에 비해 신호대 잡음비를 측정한 각각의 영역에서 차이를 나타내었다. T2 강조영상의 경우 transmit receive head coil을 사용한 두 영역 측정방법, AAPM, NEMA, Philips 모두 10% 내외의 상대 표준 편차를 가져 균일한 SNR을 나타내었지만 다중채널코일과 병렬영상기법을 적용한 두 영역측정방법의 경우 20% 이상의 상대 표준 편차를 보여 신호대 잡음비의 차이를 나타내었다. 결 론 : 다중 채널 코일과 병렬 영상 기법 적용 시 잡음의 공간적, 통계적 분포에 영향을 미치기 때문에 두 영역 측정방법으로 산출한 신호대 잡음비는 정확성이 감소하게 된다. 따라서 다중 채널 코일과 병렬 영상 기법을 적용한 영상에서 좀 더 정확한 신호대 잡음비를 산출하기 위해 AAPM, NEMA, Philips에서 제안되는 방법을 이용해야 한다.
        4,200원
        119.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 3.0T 자기 공명 영상에서 강자성 임플란트로 인해 발생한 자화감수성 인공음영에 대한 시퀀스별 WARP기법의 적정한 VAT(view angle tilting)값을 알아보았다. 대상 및 방법 : 자화감수성 인공음영(susceptibility artifact image)이 head용 워터 팬텀영상의 왜곡정도를 평가하기 위하여 head용 워터 팬텀에 강자성 임플란트(ferromagnetic implant)인 금속 와이어를 부착하여 영상을 획득하였다. 진행하였고(VAT(view angle tilting)) Warp를 사용하였다. 사용된 장비는 3.0T MRI system(MAGNETOM Skyra, Siemens, Munich, Germany)이었으며 20ch head/neck coil을 사용하여 TSE T2, TSE T1, FLAIR, Turbo IR T1 시퀀스에 WARP를 적용하여 VAT를 0~100% 범위내에서 10%씩 변화하여 각각 24개의 axial 영상을 얻었다. TSE T2 영상변수는 TR/TE 4410ms/79ms, Matrix 512×291이었으며, TSE T1 영상변수는 TR/TE 693ms/10ms, Matrix 512×291이었으며, Turbo IR T1 영상변수는 TR/TE 2000ms/9.5ms, Matrix 384×307이었으며, FLAIR 영상변수는 TR/TE 9000ms/96ms, Matrix 384×180이었다. 시퀀스별로 slice thickness 4mm, slice gap 0.4mm, NEX 1, bandwidth는 500Hz 였다. 정량평가는 팬텀영상의 대부분을 ROI로 설정 하여 표준편차를 구하였다. 정성 평가는 팬텀 영상 내에 dark area크기, image blurring 정도를 5점 척도로 하여 영상의 변화가 없는 경우 1점, 영상의 질이 약간 우수한 경우 2점, 보통 3점, 우수한 경우 4점, 매우 우수한 경우 5점으로 숙련된 방사선사 3명이 관찰 후 평가하였다. 결 과 : 정량분석으로 TSE T2와 TSE T1의 표준편차(SD)는 VAT 10%에서 VAT 적용전보다 많은 감소를 보였으며, VAT가 증가 할수록 감소하는 경향을 나타냈다. 그러나 IR 계열의 FLAIR와 Turbo IR T1은 WARP의 적용에 따른 영상차이가 없었다. 변동계수는 모든 시퀀스에서 30%이하였다. 또한 VAT 변화에 따라 영상의 위치변화도 나타났다. 정성분석으로 TSE T2는 VAT가 30~60%일 때 우수한 것으로 나타났고, TSE T1은 VAT가 10~70%일 때 우수한 것으로 나타났다. FLAIR와 Turbo IR T1은 WARP사용에 따른 영상의 변화가 없었다 결 론 : WARP는 TSE T2와 TSE T1의 자화감수성 인공음영을 줄이는데는 매우 효과적인 영상기법이었다. 그러나 WARP는 VAT를 증가시키면 image blurring도 증가함으로 VAT값을 최소화해서 사용 되어져야 할 것으로 사료된다.
        4,000원
        120.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 족관절 염좌 환자의 자기공명영상 검사 시 전하경비인대(AITFL)와 전거비인대(ATFL)를 관찰하기 위한 사방향 관상면(oblique coronal plane) 2D FSE 영상과 Isotropic 3D FSE Cube 영상의 비교를 통하여 그 유용성에 대하여 알아보고자 하였다. 대상 및 방법 : 2013년 10월부터 2013년 12월까지 족관절 염좌를 주 호소로 본 기관을 내원한 환자 15명(남자: 6명, 여자: 9명)을 대상으로, 사방향 관상면 2D FSE 기법과 시상면 3D FSE Cube 영상기법을 이용하여 AITFL과 ATFL의 영상을 획득하였다. 획득한 영상에서 AITFL과 ATFL, 골조직, 배경신호의 SI 및 CNR을 측정하고, Mann-Whitney U-검정으로 두 기법간의 통계적 유의성을 검증하여 정량적 평가를 하였다. 또한 영상의학의 2명이 각각의 영상에서 보여지는 AITFL과 ATFL의 형태 및 연속성, 부분용적에 의한 인공음영, 병변의 묘사정도의 3가지 항목을 4점 척도(0: 진단불가-Non diagnostic, 1: 부족함-Poor, 2: 적합함-Adequate, 3: 좋음-Good)로 평가하고, 평가결과 간의 일치도 검증을 위하여 Kappa-value(SPSS 19) 검정을 통해 통계적 유의성( p<0.05)을 검증하여 정성적 평가를 하였다. 영상획득에 사용된 장비는 3.0T MR 장비와 Extremity RF Coil을 사용하였다. 결 과 : 정량적 평가에서 CNR의 평균값은 AITFL의 경우 사방향 관상면 2D FSE영상에서는 10.72±0.01, 3D FSE Cube 영상에서는 18.66±0.52이었다. ATFL의 경우에는 사방향 관상면 2D FSE 영상에서는 5.62±0.98, 3D FSE Cube 영상에서는 8.15±0.65이었다. AITFL과 ATFL 모두 3D FSE Cube 영상에서 CNR 값이 높았으며, 두 영상기법 간의 CNR 값의 비교는 통계적으로 유의하였다( p<0.05). 정성적 평가에서 관찰자 1에 의한 AITFL의 형태 및 연속성, 부분용적에 의한 인공음영, 병변의 묘사정도의 평가결과는 사방향 관상면 2D FSE 영상의 경우 2.4±0.5, 2.5±0.5, 2.6±0.5의 순으로 값을 나타냈고, 3D FSE Cube 영상에서는 2.8±0.3, 2.9±0.2, 2.9±0.2의 순으로 값을 나타냈다. ATFL의 경우는 사방향 관상면 2D FSE 영상에서 2.5±0.5, 2.3±0.4, 2.5±0.5의 순으로 값을 나타냈고, 3D FSE Cube 영상에서는 2.8±0.4, 2.9±0.2, 2.9±0.2의 값을 나타냈다. 관찰자 2에 의한 AITFL의 형태 및 연속성, 부분용적에 의한 인공음영, 병변의 묘사정도의 평가결과는 사방향 관상면 2D FSE 영상의 경우 2.4±0.5, 2.3±0.8, 2.6±0.4의 순으로 값을 나타냈고, 3D FSE Cube 영상에서는 2.8±0.3, 2.8±0.3, 2.8±0.3의 값을 나타냈다. ATFL의 경우는 사방향 관상면 2D FSE 영상에서 2.8±0.4, 2.4±0.5, 2.8±0.5의 순으로 값을 나타냈고, 3D FSE Cube 영상에서는 2.9±0.2, 2.9±0.2, 2.9±0.2의 순으로 값을 나타냈다. AITFL과 ATFL 모두 3D FSE Cube 영상에서 평가 결과가 높게 나타났으며, 두 관찰자 간 평가결과의 일치도 검정은 통계적으로 유의하였다( p<0.05). 결 론 : 족관절 염좌 환자에서 3D FSE Cube 영상이 사방향 관상면 2D FSE 영상에 비해 AITFL과 ATFL의 손상 감별 및 기타 인대손상의 평가에 매우 유용하다는 것을 알 수 있었다
        4,800원