        In this study, the seismic response characteristics of the three analysis model with or without TMD were investigated to find out the effective dome shape. The three analysis models are rib type, lattice type and geodesic type dome structure composed of space frame. The maximum vertical and horizontal displacements were evaluated at 1/4 point of the span by applying the resonance harmonic load and historical earthquake loads (El Centro, Kobe, Northridge earthquakes). The study of the effective TMD installation position for the dome structure shows that seismic response control was effective when eight TMDs were installed in all types of analysis model. The investigation of the efficiency of TMD according to dome shape presents that lattice dome and geodesic dome show excellent control performance, while rib dome shows different control performance depending on the historical seismic loads. Therefore, lattice and geodesic types are desirable for seismic response reduction using TMD compared to rib type.
        4,000원
        2.
        2023.11 구독 인증기관·개인회원 무료
        Kori unit 1 and Wolsong unit 1 were permanently shut down in 2017 and 2019, respectively. Both plants were decided to demolish the building without reuse. Large structures must be demolished after removing systems and components in the building, and in the case of large structures, thorough planning is required because of the large scale of work. Therefore, in this study, important considerations in the phase of the demolition plan of large structures when decommissioning were analyzed. The demolition of large structures at nuclear facilities is major one phase of work within a broader decommissioning plan. Furthermore, the actual demolition of the structure (i.e., physical process) represents the last step in a process that begins with extensive planning and analysis. The National Demolition Association (NDA) has provided checklist items that should be considered before the start of a commercial demolition project and/or in the bid process. Important Considerations in the Phase of the demolition plan of large structures when decommissioning of nuclear facilities are Site knowledge and programs, Engineering survey/demolition plan, Hazardous and radioactive materials, Open air demolition, Financial and project management, Permits, Code adherence, and Special programs, Disposal pathway, Final site condition. The results of this study can be used as a basis for the Planning large structures demolition of the Kori unit 1 and Wolsong unit 1.
        4.
        2023.05 구독 인증기관·개인회원 무료
        Among the twenty six nuclear power plants in Korea, twenty four plants are currently in operation excluding the two permanently shut-down Kori #1 and Wolsung #1 plants. The decommissioning process includes many tasks such as cutting, decontamination, disposal and treatment. Among the tasks, because cutting is one of the tasks performed close to the target structure, there is a possibility for the workers to be exposed excessively to the radiation. There are representative large structures such as steam generators, nuclear reactors, reactor coolant pump, and pressurizer, made of metals, and radioactive concrete, made of concrete. Especially, compared to the trend of research to manage the radiation exposure of steam generators that are directly connected to pressurizers, the trend of research to manage the radiation exposure of pressurizers to workers is not satisfactory. Moreover, although there have been many studies on radioactive concrete, the studies to manage the radiation exposure to workers with a systematic cutting scenario are insufficient. In this study, radioactive concrete, a representative large structure made of concrete, was selected as the target for evaluation. The conditions for evaluation were cutting speed (1~10 m2/hr) and the time for cutting (permanent shutdown~30 years after the shutdown). A cutting scenario was developed by applying the situation for abrasive decontamination beforehand and Hot-to-Cold and Cold-to-Hot, and effort was made to derive a reasonable plan. The evaluation result derived were hourly radiation dose distribution of 1.19~0.103 mSv/hour and 1.29~0.0113 mSv/hour for a scenario without abrasive decontamination (in the order of Hot to Cold, Cold to Hot), and hourly radiation dose distribution of 0.547~0.0479 mSv/hour and 0.608~0.0522 mSv/hour for a scenario with abrasive decontamination. The maximum value of collective dose derived was 1.54E+04 mSv at the cutting time of permanent shutdown with cutting speed of 1 m2/hour in the Cold to Hot scenario before abrasive decontamination, and the minimum value derived was 5.15E+01 mSv at the cutting time of 30-year after the permanent shutdown with cutting speed of 10 m2/hour in the Hot to Cold scenario after abrasive decontamination.
        7.
        2021.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As people's living standards and cultural standards have developed, interest in culture and art has increased, and the demand for large space structures where people can enjoy art, music, and sports has increased. As it accommodates a large number of personnel, it is most important to ensure safety of large spatial structures, and can be used as a space where people can evacuate in case of a disaster. Large spatial structures should be prepared for earthquake loads rather than wind loads. In addition to damage to the structure due to earthquakes, there are cases in which it was not utilized as a space for evacuation due to the fall of objects installed on top of the structure. Therefore, in this study, the dome-shaped large spatial structure is generalized and the displacement response according to the number of installations, position and mass is analyzed using a tuned mass damper(TMD) that is representative vibration control device.
        4,000원
        8.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문는 개폐식 대공간 구조물의 지진하중에 대한 동적응답을 줄이기 위한 목적으로 파라메트릭 설계 기법을 적용한 TMD에 관한 연구이다. 인공지능 알고리즘을 이용하여 감쇠장치의 설치 위치를 자동 탐색하는 컴포넌트를 개발하였다. 이는 구조물의 동적응답을 실시간으로 확인하고, 구조물의 감쇠장치 최적의 위치를 찾을 수 있을 있다. 또한, 여러 대안에 대한 감쇠장치 질량의 최적 값을 찾아주며, 지붕의 열린 상태와 닫힌 상태에 모두 효과적으로 적용될 수 있는 설계안을 찾을 수 있다.
        4,000원
        9.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a tuned mass damper(TMD) was installed to control the displacement response to earthquakes by generalizing to six analysis models according to the shape of the upper structure based on the case of various large spatial structures around the world. The six analysis models are ribbed type, latticed type, elliptical type, gable type, barrel type, and stadium type composed of 3D arch trusses. In this paper, ribbed type, latticed type and elliptical type were analyzed. The mass of each TMD was set to 1% of the total structural mass. Result of analyzing the optimal number and position of the analysis model, the displacement response control was the most excellent in the model with 6 and 8 TMDs, and the displacement response decreased in most cases. The displacement response control was better with installing the TMD at the edge point than focusing the TMD at the center of the analysis model. However, when 10 or more TMDs are installed or concentrated in the center, large loads intensively act on the structure, resulting in increased displacement. Therefore, although it is slightly different depending on the shape, it is judged that the displacement response control is the best to install 6 and 8 TMDs at the close to the edge point.
        4,000원
        10.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a tuned mass damper(TMD) was installed to control the displacement response to earthquakes by generalizing to six analysis models according to the shape of the upper structure based on the case of various large spatial structures around the world. The six analysis models are ribbed type, latticed type, elliptical type, gable type, barrel type, and stadium type composed of 3D arch trusses. In this paper, ribbed type, latticed type and elliptical type were analyzed. The mass of each TMD was set to 1% of the total structural mass. Result of analyzing the optimal number and position of the analysis model, the displacement response control was the most excellent in the model with 6 and 8 TMDs, and the displacement response decreased in most cases. The displacement response control was better with installing the TMD at the edge point than focusing the TMD at the center of the analysis model. However, when 10 or more TMDs are installed or concentrated in the center, large loads intensively act on the structure, resulting in increased displacement. Therefore, although it is slightly different depending on the shape, it is judged that the displacement response control is the best to install 6 and 8 TMDs at the close to the edge point.
        4,000원
        12.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 개폐식 대공간 구조물의 풍하중 산정 및 구조해석의 과정을 자동으로 수행하는 컴포넌트를 개발하는 것이다. 설계한 파라메트릭 모델링을 StrAuto를 통해 구조해석 자동화단계를 거쳐 구조해석용 모델로 변환하는 과정을 실시간 으로 연동하여 구조해석 결과를 자동으로 도출하는 과정으로부터 본 연구에서는 추가로 구조물의 풍하중을 형상에 따라 상세히 할당하는 기능을 개발하였다. 이와 같은 과정을 통해 풍하중에 대한 최적화를 수행하여, 기존 설계된 구조의 물량을 줄이고, 구조적 안정성은 유지하는 방향으로 결론을 도출하였다. 추후에는 본 예제 모델을 통해 진동제어 최적화를 위한 제진 장치 설치위치의 자동탐색이 가능하게 되는 연구를 진행할 계획이다.
        4,000원
        18.
        2017.04 구독 인증기관 무료, 개인회원 유료
        Due to the sewer induced ground subsidence, there is an increasing demand for the advanced visual inspection technique for the existing sewer pipe structures. This study aim to develop a visual inspection device and real-time transmission system of inspection data with precisely evaluated structural and operational conditions of underground sewer pipe structures. In this paper, a high-precision image capturing system that automatically extracts cracks in the large-diameter sewer pipes and sewage culverts with a diameter of 1,000 mm or more, a real-time gas detection sensor for investigator safety were studied. By analyzing the module technology of the visual inspection device, the concept design for system integration was derived, and the real time transmission system of the inspection result was developed to establish the technical basis for the commercialized device. Also the crack detection test using crack calibration was carried out for the proposed image capturing camera system, and the position accuracy using L1 grade GPS module was tested in this study. The inspection technique of the existing structure condition using the visual inspection device in this study can be effectively used for various structures types and advanced composite structures in the future.
        3,000원
        19.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Since the 1980s, the number of large space buildings in Korea has consistently been increasing due to large scale international competitions such as the Olympics and the World Cup, demands for environmental improvement, and development of structural systems. Due to these reasons, this paper conducted a comparative analysis on terrorism risk factors of large space structure and skyscrapers in Korea. The results suggest that the total risk level of high-rise and large space structure was "medium level risk" and that the terrorism risk level for large space structure was as high as that for high-rise buildings. As it relates to the risk levels depending on scenarios, terrorism risks to large space structure were higher than high-rise buildings in the "internal explosion" and "internal intrusion" categories. And the results of analyzing explosion-related scenarios except for CBR suggest that terrorism risks to large space structure were highest when it comes to Internal-Explosive followed by Internal-Intrusion and Explosive-Zone I; and the results showed a regular pattern. On the other hand, in the case of high-rise buildings, terrorism risks were highest in Internal-Explosive followed by Explosive-Zone I and Explosive-Zone II; and the results showed an irregular pattern.
        4,000원
        20.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The serviceability design of the high-rise building is affected by the wind response vibration such as the acceleration, at this time it is important to calculate the natural frequency correctly. Since the suggestion equation of the natural frequency being used in the design phase is not the regression equation obtained from the vibration measurement of the high-rise building, the verification to use for the serviceability design of the high-rise building is necessary. This thesis conducted an ambient vibration measuring on the high-rise building through the mobile-phone application to calculate the natural frequency and suggested a natural frequency approximate expression following the building's height, and compared with the domestic/foreign standard and the result of the eigen-value analysis.