검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 12

        2.
        2009.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a low temperature growth of high-quality carbon nanotubes on glass substrate using a local surface heating without heating damage to substrate was tried and characterized. The local joule heating was induced to only Ni/Ti metal film on glass substrate by applying voltage to the film. It was estimated that local surface joule heating method could heat the metal surface locally up to around 1200℃ by voltage control. We could successfully obtain high-quality carbon nanotubes grown at 300℃ by applying 125 V for joule heating as same as carbon nanotubes grown at 900℃.
        3,000원
        3.
        2019.10 서비스 종료(열람 제한)
        고층의 공공 건축물에서 에스컬레이터는 수많은 탑승자가 동시에 이용하는 필수적인 수직 이동 시설물이다. 에스컬레이터에서 구동체인은 동력을 전달하는 핵심 부품인데, 구동체인 파단에 의한 역주행 사고가 지속적으로 발생하고 있으며, 이는 대형인명사고로 이어지고 있어 이의 예방이 반드시 필요한 상황이다. 본 연구에서는 체인의 초기 파단손상 진단을 통한 예방적 유지관리를 위해 마그네틱 센서 기반의 비파괴 진단 기법을 구동체인에 적용하였다. 이의 실험적 검증을 위해 다채널의 자속신호를 동시 수집할 수 있는 마그네틱 센서헤드를 제작하였고, 이를 에스컬레이터 시뮬레이터에 설치되어 구동되는 더블체인 손상시편에 적용하여 자속신호를 수집하였다. 수집된 각 채널별 자속 신호로부터 국부 손상부에서 발생하는 자속의 변화 특성을 확인하였고, 이러한 특성을 부각하여 이용하고자 다단계의 신호처리를 수행하였다. 가공된 자속신호를 손상 판단을 위해 설정된 통계기반의 임계값에 적용함으로써 구동체인에 발생한 국부손상을 객관적으로 자동 진단하였다.
        4.
        2019.04 서비스 종료(열람 제한)
        In this study, it evaluate the Local damage properties of amorphous metallic fiber reinforced cement composite by different fiber length. 30mm and 15mm length of amorphous metallic fiber was reinforced and fiber volume fraction was set to 1.0, 1.5 vol.%. Flexural test and high speed projectile impact test was performed. As as result, 30mm length of specimen showed more good flexural and impact resistance performance compared to 15mm length of specimen.
        5.
        2019.04 서비스 종료(열람 제한)
        Magnetic sensing NDE(non-destructive evaluation) method was applied to detect local damages at the steel chain of the escalator. To verify the feasibility of the magnetic sensing based chain inspection method, a magnetic sensor head was fabricated to adapt to the target chain. The fabricated sensor head scanned the notch damaged chain specimen to measure the magnetic flux signals. After obtaining signal, a series of signal processing process including pick picking and enveloping process based on Hilbert transform (HT) was performed to detect the damaged point by clarifying the signal.
        6.
        2018.10 서비스 종료(열람 제한)
        In this study, a magnetic flux leakage (MFL) method that is known as a suitable non-destructive evaluation (NDE) method for continuum ferromagnetic members was applied to detect the various types of local damages of the steel wire ropes. 3types of artificial damages, such as cutting, corrosion and compression, were formed on wire rope specimen. A multi-channel MFL sensor head that can maintain the constant lift-off was fabricated to scan the wire rope specimen. The fabricated MFL sensor head measured the magnetic flux signals from the three types of damaged specimens. The capability of damage detection according to damage type was verified from the measured MFL signals from each type of damage. And, the characteristics of the MFL signals were compared and analyzed by type of damage.
        7.
        2018.04 서비스 종료(열람 제한)
        This study presents the investigation for relationship between local damage and structural performance of the 7-wire strand. This strand is often used additional reinforcement of bridges such as PSC (Prestressed Concrete) bridge and cable-stayed bridge. Stay cables are continuously damaged after completion and corrosion is the main cause of damage. Due to its structural characteristics, it is difficult to quantitatively evaluate the degradation cable damage. Therefore the relationship between local damages on strand and structural performance is experimentally and analytically evaluated in this study. The results can be used for the safety management of the cable supported bridges in the future.
        8.
        2016.12 KCI 등재 서비스 종료(열람 제한)
        본 연구는 부산광역시 거주민을 대상으로 원전주변 갑상선암 피해 소송 이후 원자력발전소 인근지역과 시내권에 거주하는 주민간의 인식 차이를 분석하여 국민들의 원자력에 대한 수용성 수준을 판별하고자 하였다. 설문조사는 총 551명(원전인근지역 269명, 시내권 282명)을 대상으로 대인면접을 통해 이루어졌으며, 분석 결과, 원전 주변 갑상선암 발병 피해 소송 사건을 계기로 국민들의 원자력에 대한 인식에 변화가 있는 것으로 나타났다. 원전인근지역 주민의 경우 사건 이후 원자력에 대한 불신과 불안감이 높아져, 원자력에 대한 부정적 인식이 강해졌음을 확인할 수 있었다. 반면 시내권 주민들은 원전 주변 갑상선암 발병 피해 소송 사건에도 불구하고 사건 이전보다 더욱 원자력 수용성에 긍정적인 인식을 갖는 것으로 분석되었다. 그러나 원자력 안전성과 신뢰성에 대한 인식은 부정적인 것으로 분석되어 원자력 수용성과 상반되는 이중적인 인식을 보였다. 이는 부산광역시 시내권 주민들의 경우 원자력의 편익, 필요성 등을 원칙적으로 인정하나 안전성에 대해서는 의심하는 것으로 판단되며 향후 원자력의 이용 확대를 지속적으로 추진하기 위해서는 국민의 올바른 이해와 신뢰 그리고 무엇보다 국민 또는 원전인근지역 주민들과 충분한 의사소통이 필요하다고 사료된다.
        9.
        2014.10 서비스 종료(열람 제한)
        In this study, the investigation of the local damage evaluation method for the SC structure subjected to impact load was carried out. The conventional RC formula and SC formula to calculate wall thickness to prevent perforation were studied and compared. Finally, these results were compared with finite element analysis results using LS-Dyna, and the future direction to develop the reasonable local damage evaluation method of the NPP SC structure was suggested.
        10.
        2014.10 서비스 종료(열람 제한)
        Tensile stress and strain of rear by shock wave become the cause of rear side scabbing of concrete subjected to high-velocity impact. Improvement of flexural and tensile performance by fiber reinforcement has great effect on the suppression of the rear scabbing.
        11.
        2009.03 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 동적 가속도 데이터를 사용하는 신호기반 손상진단 알고리즘으로 ARX 모델을 제시하였다. ARX 모델은 구조물의 두 지점에서 계측된 가속도 데이터를 입력과 출력의 두 세트 신호로 보고, 두 세트 가속도 데이터의 상관관계를 설정한다. 구조물 손상은 계측한 데이터와 전달함수인 ARX 모델로 예측한 데이터의 차이인 시간이력 잔차를 사용하여 통계적으로 탐색하였다. 시간이력 잔차의 정규분포함수를 구하고, 그 통계적 특성치를 계산하여 손상 평가에 사용하였다. 손상 전후의 정규분포함수를 비교하여 손상을 탐색하기 위하여 세 가지 손상지수를 제시하였다. 손상지수의 통계적 평가를 위해 실내실험을 수행하였고, 제안한 알고리즘의 효율성을 검증하고 제한점을 검토하였다.