        Existing reinforced concrete building structures have seismic vulnerabilities due to their seismically-deficient details resulting in non-ductile behavior. The seismic vulnerabilities can be mitigated by retrofitting the buildings using a fiber-reinforced polymer column jacketing system, which can provide additional confining pressures to existing columns to improve their lateral resisting capacities. This study presents dynamic responses of a full-scale non-ductile reinforced concrete frame retrofitted using a fiber-reinforced polymer column jacketing system. A series of forced-vibration testing was performed to measure the dynamic responses (e.g. natural frequencies, story drifts and column/beam rotations). Additionally, the dynamic responses of the retrofitted frame were compared to those of the non-retrofitted frame to investigate effectiveness of the retrofit system. The experimental results demonstrate that the retrofit system installed on the first story columns contributed to reducing story drifts and column rotations. Additionally, the retrofit scheme helped mitigate damage concentration on the first story columns as compared to the non-retrofitted frame.
        4,000원
        2.
        2017.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        구조물의 성능을 개선하기 위하여 다양한 진동제어장치가 사용되고 있다. 대부분의 제진장치는 구조물의 감쇠비를 증가시킴으로써 성능개선효과를 유도하기 때문에 증가된 감쇠비는 제진장치에 의한 구조물의 성능을 평가하는 중요한 지표가 될 수 있다. 본 연구에서는 강풍 등으로 제진장치가 운영 중인 상태에서 구조물의 응답만을 이용하여 각 모드에 증가된 등가감쇠비를 추정하는 프로세스를 개발하고 이를 성능개선효과를 평가하는데 활용하고자한다. 제진장치가 설치된 구조물은 비고전 감쇠시스템이므로 상태공간 모드분해법을 이용하여 계측응답으로부터 모드 응답을 구하고, 분해된 모드응답에 가상 동적 진동기를 적용하여 각 모드에 증가된 감 쇠비를 구하였다. 제안된 제진장치 설치 구조물 감쇠비 추정법을 검증하기 위하여 수동형 제진장치로 카고메 점탄성 댐퍼를, 능동형 제진장치로 능동질량감쇠기를 구조물에 적용하여 각 제진장치에 의한 감쇠비를 추정한 결과 매우 정교하게 예측 가능함을 알 수 있었다.
        4,000원
        3.
        2003.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 전단변형을 고려한 비대칭 박벽 곡선보의 자유진동해석을 수행할 수 있는 일반이론을 제시하기 위하여, 3차원 연속체에 대한 가상일의 원리로부터 전단변형 효과를 고려하고 비대칭 박벽단면과 ?(Warping)을 포함하는 변위장을 도심 축에 대해 정의한 후 곡선보의 변형도-변위관계로부터 공간 박벽 곡선보의 일반화된 탄성변형에너지와 운동에너지를 새롭게 유도한다. 또한, 전단변형이 고려된 곡선보의 총포텐셜에너지에 대해 변분을 취함으로써 평형방정식과 힘-변위관계를 제시한다. 한편, 제시된 이론에 대해 등매개 보요소를 도입하여 유한요소 정식화를 수행하였으며 곡선보의 동적 거동특성을 조사하기 위하여 전단변형, 곡률효과 그리고 진동모드에 대한 매개변수 연구를 수행한다. 마지막으로, 본 연구의 타당성을 입증하기 위하여, 다양한 해석예제에 대한 3차원 고유진동수를 산정하고 타 연구자들의 결과 및 ABAQUS의 쉘요소를 이용한 해석결과와 비교ㆍ검증한다.
        4,500원
        4.
        1999.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        변단 면과 다양한 경계조건을 갖는 보와 타워구조물의 제1모드에서의 고유진동수를 구하는 정확한 해는 1974년에 Kim에 의해 발표되었다. 최근 이 방법은 복합재료 적층 판을 포함하는 2차원 문제의 제 1모드 진동해석에 확장되었으며, 다양한 경계조건과 불규칙 단면을 갖는 판에 매우 효과적이다. 이 논문에서는 변단 면과 경계조건에 따른 특별직교 이방성 판에 대한, Kim에 의해 개발된 간편한 진동해석 방법의 응용결과가 주어진다. 또한 집중하중들에 대한 영향이 연구되었다.
        4,000원
        5.
        2016.06 KCI 등재 서비스 종료(열람 제한)
        For elevated railway station on which track is connected with superstructure of station, structural vibration level and structure-borne-noise level has exceeded the reference level due to structural characteristics which transmits vibration directly. Therefore, existing elevated railway station is in need of economical and effective vibration reduction method which enable train service without interruption. In this study, structural vibration non-transmissible system which is applied to vibroisolating material for column member is developed to reduce vibration. That system is cut covering material of the column section using water-jet method and is installed with vibroisolating material on cut section. To verify vibration reduction effect and structural performance for structural vibration non-transmissible system, impact hammer test and cyclic lateral load test are performed for 1/4 scale test specimens. It is observed that natural period which means vibration response characteristics is shifted , and damping ratio is increased about 15~30% which means that system is effective to reduce structural vibration through vibration test. Also load-displacement relation and stiffness change rate of the columns are examined, and it is shown that ductility and energy dissipation capacity is increased. From test results, it is found that vibration non-transmissible system which is applied to column member enable to maintains structural function.
        6.
        2013.10 서비스 종료(열람 제한)
        In this Study cable tension of existing cable-stayed bridge is measured by non-contact laser vibrometer, and applicability of a non-contact vibration measurement method is experimentally evaluated. According to the analysis results, the non-contact vibration measurement method reveals an error of less than 5%, and could be efficiently applied to a rapid measurement for nonstationary response analysis of bridge structures.
        7.
        2010.11 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 비부착식 진동측정기법에 의한 공용중 교량의 진동사용성을 평가하고자 레이저 진동측정장치를 이용하여 진동사용성 평가 실험을 하였으며, 그 결과를 가속도계 및 처짐계를 사용하여 얻은 결과와 비교 분석 하였다. 레이저 진동측정장치의 측정에 대한 정확도는 실교량의 고유진동수를 측정하고, 이를 가속도계로 구한 값과 비교함으로서 검증하였다. 진동사용성 평가 실험 및 비교 분석 결과에 의하면, 측정속도의 수치미분을 통하여 가속도를 추정하고, 가속도 진폭에 대한 Reiher-Meister 진동사용성 평가기준을 이용함으로써 공용중 교량의 진동사용성을 평가할 수 있으며, 추정된 변위 진폭에 대한 경우 측정속도의 시간영역 수치적분 과정에서 발생된 오차로 인해 실제 측정된 변위 진폭에 대한 진동사용성 등급과는 다른 결과를 얻을 수 있음을 알 수 있었다.