검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 12

        1.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the distribution characteristics of particulate matter (PM) in subway platforms were investigated, and the performance of hybrid filter systems was determined through the removal efficiency of PM according to various flow rates and filter structures. The hybrid filter systems were constructed in magnetic systems as (Magnet-Magnet (MM) filters and Magnet-Cascade (MC) filters). PM removal efficiencies of these filters were investigated at a subway platform for three days including weekdays and weekends. The compositions of collected PM were also analyzed. Based on the PM measurement in the subway platforms, it was confirmed that the operation of trains had a significant effect on the increase of PM concentration, and a large number of PMs were less than 1 μm in size. For the MC filter, the removal efficiency of PM1 based on the number of particles was up to 30.5%, demonstrating a relatively high removal efficiency in comparison with the MM filter. In terms of PM10, PM removal efficiencies of the MC filter with respect to the mass concentration and the number of particles were 48.3% and 14.5%, respectively. For the MC filter, it was found that the PM removal efficiency was enhanced with the increase in the flow rate. Moreover, the relatively large particle size PM (i.e., 7.5 μm - 10 μm) denoted a maximum removal efficiency of 97% in terms of the number of particles. All PMs collected by the filter were Fecontaining PMs. As a field experiment using the hybrid filter, the applicability of magnetic particle control technology was approved. Based on this result, it is expected that this study will be used as background research for the development of fine dust control technologies in a subway environment.
        4,000원
        3.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We developed a wet scrubber by applying cyclone flow to the gas flow and using a spiral filter structure. While the size of a new scrubber was about half that of a conventional scrubber, the device showed relatively high efficiency in pollutants removal such as particulate matter and compounds inducing odor. The new scrubber installed in a plating industry showed a higher removal efficiency of about 5% for dust, about 23% for hydrogen chloride, and about 23% for sulfur dioxide compared to the conventional scrubber. Plurality of tubes in the spiral filer housing are arranged to be vertically shifted from each other. Because the upward residual gas does not directly rise vertically, the residence time of gas between the filter plates is extended. Thus, the purification efficiency of the pollutants was enhanced in the new scrubber. In addition, the new scrubber developed in this study is more cost effective because the cost saving in manufacturing it compared with a conventional scrubber increases with increasing the size of equipment. It is expected that a scrubber with better dust collecting efficiency can be obtained by carrying out a study in connection with facilities capable of controlling acidity of washing water.
        4,000원
        5.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Many countries of the world has been devoting a lot of effort to reduce carbon emission. In order to reduce carbon emission, the high efficiency engine has been studied in the automotive industry. Of these, the spread and research of the diesel engine in Europe center are active. However the combustion characteristic of diesel engines have disadvantages of much NOx and soot emissions. In this study, the optimum regeneration point of the forced regeneration type DPF(Diesel Particulate Filter) that was equipped in medium-duty diesel vehicles using a mechanical fuel injection system have studied. DPF that is applied to the medium-duty diesel vehicle has a bent inlet pipe. The flow distribution characteristics of DPF according to the influence of the bent pipe have investigated. The flow distribution characteristics of DPF according to variation of the engine operating condition is considered to be useful data In order to decide the optimum regeneration point.
        4,000원
        6.
        2013.08 구독 인증기관 무료, 개인회원 유료
        The aims of research of this paper are as follows; first of all, main contents of technical development are such as. 1. the burner system development for maximum efficiency of diesel particulate filter in low temperature emission gas, 2. the development of white fume reducing system by the second ejection in diesel, 3. the development of burner system for erasing of oxidation catalyzer of the most important role in diesel particulate filter, And the secondhand, expectation effect of this paper is such as. If the mass production of this development is successfully, this system is easy to applicable to small diesel vehicle stopping by low efficiency diesel particulate filter and is increased cost effective and adaptability by erasing oxidation catalyzer.
        3,000원
        7.
        2012.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was analyzed the characteristics of temperature distribution in DPF(Diesel Particulate Filter) equipped with partitioned electric heaters. Analysis parameters was used by variation to the length of pipe from exhaust manifold to inlet of filter. The temperature of the exhaust gas flowing into the DPF is related closely to the regeneration of filter. Due to space constraints, the DPF have inlet of bent pipe. The inlet of bent pipe induce the heterogeneous distribution of flow. The heterogeneous trapping of smoke is induced according to the heterogeneous distribution of flow. And the heterogeneous distribution of temperature in DPF is induced. In this study, without the use of assistive devices for even distribution of flow into DPF, the characteristics of temperature distribution in DPF were investigated according to the variation of the length of inlet pipe.
        4,000원
        10.
        1998.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        경유자동차에서 발생하는 입자상물질은 대기오염의 주범으로 인식되어 국내외적으로 이의 규제가 점점 강화되고 있다. 본 고에서는 전 호에 이어 이러한 입자상물질을 제거하기 위하여 가장 보편적으로 사용되는 필터인 세라믹 하니컴 필터에서의 기공 및 필터특성의 조절과 설계에 대하여 언급하였다. 또한 그 외 각종 필터, 즉 세라믹 화이버 캔들 필터, 세라믹 폼 필터, 세라믹 크로스 플로우 필터 그리고 금속 필터 등의 성능 및 제조방법을 정리하였다. 이와같이 후처리장치용 필터로는 수없이 많은 필터들이 개발되어 많은 실증시험을 거치고 있으나 이러한 필터의 본격적인 상용화를 위하여는 재료 측면에서의 보다 많은 연구, 개발이 뒤따라야 할 것으로 판단된다.
        4,300원
        11.
        1998.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        경유자동차에 의한 오염물질의 배출은 주로 입자상물질과 NOx가 문제시되고 있는데 특히 입자상물질은 각종 호흡기질환의 원인 등으로 간주되어 이의 규제가 국내외적으로 강화되고 있다. 본 고에서는 이러한 입자상 물질을 제거하기 위하여 사용되는 각종 필터의 특성 및 제조방법에 대하여 알아보고자 하였다. 이를 위하여 먼저 경유자동차에서 발생하는 오염물질 및 이의 규제현황에 대하여 다루었으며 각종 후처리장치의 종류 및 개발현황에 대하여 언급하였다. 다음으로 가장 일반적으로 사용되어지는 필터인 세라믹 하니컴 필터를 중심으로 하여 원료 및 소재, 제조방법 그리고 열팽창계수의 조절 등에 대하여 논하였다.
        4,500원
        12.
        2014.08 KCI 등재 서비스 종료(열람 제한)
        Foundry has an important economic value in the industry. However, the generation of air pollutants like particulate and odor are serious. Due to the unavoidable usage of molding sand, particulate occurs in almost all the processes. That accounts for the majority of respirable dust in the size less than 10 ㎛. As well as particulate, over 22 species of odor-causing gases and VOCs including hydrogen sulfide and ammonia are occurred. Therefore, the development of equipment that can simultaneously remove TVOC and particulate is regarded as an essential research. In this study, the spraying absorbent system was connected with the shear bag filter for the purpose to remove TVOC and particulate simultaneously. Maximization of process efficiency for the affective factors like the powder combination and injection method is conducted. The experiment was performed at the de-molding process of one foundry plant. Through these devices, the removal efficiency of more than 95% for TVOC was achieved with the absorbent that composed by 800 mesh Activated carbon (80%) and 300 mesh zeolite (20%). Also, the durability and economic evaluation were assessed. In the result of Durability assessment, the available recovery to maintain the deodorizing effect at 90% was counted to 350 degree.