검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 13

        1.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        UHPC(Ultra High Performance Concrete) is used widely with its remarkable performance, such as strength, ductility and durability. Since the fibers in the UHPC can control the tensile crack, the punching shear capacity of UHPC is higher than that of the conventional concrete. In this paper, seven slabs with different thickness and fiber volume ratio were tested. The ultimate punching shear strength was increased with the fiber volume ratio up to 1%. The shear capacity of specimens with the fiber content 1% and 1.5% do not have big differences. The thicker slab has higher punching shear strength and lower deformation capacity. The critical sections of punching shear failure were similar regardless of the fiber volume ratio, but it were larger in thicker slab.
        4,000원
        2.
        2014.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 유공형 형상의 GFRP 판으로 전단 보강된 플랫 플레이트의 전단거동을 실험을 통해 평가하였다. GFRP 판은 개구부가 있는 판의 형태로서 콘크리트와의 일체화 거동을 위하여 콘크리트에 매립하여 시공하였다. GFRP 판으로 전단보강된 플랫 플레이트의 전단 성능 실험을 위하여 총 7개의 시험체에 대한 전단 실험을 수행하였다. 실험 변수로는 전단 보강량, 전단 보강 간격을 선정하였다. GFRP 판의 전단 보강량에 따른 비교결과, 전단 보강량이 증가할수록 전단강도도 증가하는 결과를 보여주었다. GFRP 전단 보강 간격에 따른 비교결과, 전단 보강 간격이 0.3d 일 때 가장 높은 전단강도를 확인하였다. 실험결과를 바탕으로 KCI에서 제시하고 있는 전단강도식을 수정하여 GFRP 판에 적용이 가능한지 평가하였다.
        4,000원
        3.
        2014.04 구독 인증기관·개인회원 무료
        An experimental study was carried out to evaluate the punching shear performance of H-steel column + RC slab system for vertical load. Three specimens were constructed for interior column-slab system. All specimens were the same configuration and material properties except for columns such as RC column+flat plate slab and H-Steel column+flat plate slab. From the test results structural characteristics (maximum proof stress, maximum displacement, deformation capabilities and so on) are obtained and evaluated.
        4.
        2009.03 구독 인증기관 무료, 개인회원 유료
        A improved strength model was developed to predict the punching shear strength of interior slab-column connections without shear reinforcement. Considering the damage due to flexural cracking at slab-column connections damaged by flexural cracking, the punchingshear force was assumed to be resisted mainly by the compression zone of the critical section. The punching shear strength was defined by using the material failure criteria of concrete. In the evaluation of the punching shear strength, the interaction between the shear stress and the compressive normal stress developed by the flexural moment of the slab was considered. The proposed strength model was verified by existing test specimens.
        4,000원
        5.
        2017.03 KCI 등재 서비스 종료(열람 제한)
        This study was made to examine the motion characteristics according to the reinforcement of the reinforcement length and stiffener reinforcement for shear reinforcement to the foundation structure reinforced with shear reinforcement steel plate. Experimental study was made after specimen was installed on the ground as the same as in the practical site. Reinforcement lengths of the steel for shear reinforcement are divided into 1,000 mm, 1,200 mm and 1,400 mm in the specimen and as for reinforcement method of the stiffener, 4 stiffeners with interval of 100mm reinforced with the same materials as the shear reinforcement were manufactured for the experiment. Considering result of the experiment, it is expressed that no effect of the stiffener reinforcement was found and regarding the reinforcement length of shear reinforcement material the crossed point of the two converted lines of the value that the shear force is expressed in the bearing power in the expanded dangerous section and the value that the shear capacity receivable by the reinforcement materials in the dangerous section is proposed as effective reinforcement length.
        6.
        2015.04 서비스 종료(열람 제한)
        In this paper, punching shear test of flat plate reinforced by plates with openings has performed. And compared critical section of ACI 318, BS 8110, and Eurocode 2. Non-reinforced specimens and specimens that reinforced by GFRP plates with openings are manufactured. Shear reinforcement spacing was used as parameter for specimens reinforced by GFRP plates. Crack pattern showed that critical section increased as shear reinforcement spacing increased compared to critical section of ACI 318, BS 8110, and Eurocode 2. Critical section calculated by ACI 318 was the smallest predicted section, and sections calculated by BS 8110 and Eurocode 2 are larger predicted section.
        7.
        2015.04 서비스 종료(열람 제한)
        The objective of this study is to evaluate the location of a failure surface generatrix and the punching shear strength of hollow plat slabs. The main test parameters was the location of a starting position of hollow materials that varied between 1d and 3d, where d is effective depth of slab section. Based on test results, the starting position of hollow materials in plat slabs is recommended to be more than 2d to avoid the reduction of concrete punching shear strength.
        8.
        2015.03 KCI 등재 서비스 종료(열람 제한)
        In this paper, the RC column-based joint connection part carry out loading test by reinforced hollow or extended Base Plate in order to confirm that RC joint punching shear reinforcement effect of applying the Base Plate. Base Plate thickness, extension length, size, and type as the variable, Base Plate suitable for the stress distribution and shape and dimensions confirmed through experiment and then reinforcing effect was analyzed. Experimentally, vertical load transmitted to the Base Plate from column to foundation is effective to stress distribution and then, type of hollow reinforcement more efficient than a closed. Through experiment, improve performance and ductility due to reinforcement and relative to the thickness of the existing foundation reduced even showed better performance than the existing. The behavior of the reinforced specimens be able to induce from brittle to ductile. Experiment on loading to destroy performed the pattern of cracks, destruction aspect before and after reinforcement.
        9.
        2011.07 KCI 등재 서비스 종료(열람 제한)
        강섬유보강 초고성능 콘크리트(UHPC)는 압축강도가 200MPa에 이르고, 강성 및 인성이 크기 때문에 이를 이용하면 구조 부재를 얇고 가볍게 설계하는 것이 가능하다. 본 논문은 UHPC를 교량의 바닥판 슬래브에 적용하기 위해서 뚫림전단(punching shear)에 대한 저항능력을 평가한 것이다. 6개의 정사각형 슬래브를 제작하여 4변 완전고정 상태에서 뚫림전단 실험을 수행하였다. 슬래브의 두께는 40mm와 70mm였고, 재하판의 형상비는 1.0~2.5 범위였다. 40mm 실험체는 최대하중 이후에 연성적인 변형률 연화구간이 길고, 70mm 실험체는 상대적으로 더 취성적인 뚫림파괴를 보였다. 기존의 여러 뚫림전단강도 평가식을 이용하여 실험결과를 분석하였는데, 두께가 작은 40mm 실험체에서는 DuctalⓇ 및 JSCE의 식이, 그리고 70mm 실험체에서는 Harajli et al. 및 ACI-DuctalⓇ의 제안식이 상대적으로 실험에 근접한 값을 예측하였다. 그러나 전반적으로 실험결과를 잘 예측하지 못하였으므로 실제 파괴메커니즘에 근거한 새로운 식을 제안하였다. 새로 제안한 식은 실험결과를 비교적 잘 예측하는 것으로 나타났다.
        10.
        2011.03 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는, 철근 밀집 감소, 노무비 및 보수 보강비 절약, 향상된 부식 저항성, 공기 단축 등의 장점을 가지고 있는 고성능 철근으로 휨 보강된 이방향 슬래브를 제작하고 구조실험을 실시하였다. 상부 휨철근비, 기둥 인접부 휨철근의 집중배근, 강섬유 보강 콘크리트의 타설을 변수로 하여 실험하였고, 펀칭 전단강도 및 균열후 강성을 일반 철근 및 GFRP bar로 휨 보강된 슬래브의 펀칭 전단실험 결과와 비교하였다. 또한, 휨철근의 변형률 분포 및 균열제어 효과 등을 비교, 분석하였고, 휨철근비 계산을 위한 유효폭 산정 방법을 검토하였다. 고성능 철근의 사용으로 펀칭 전단강도가 향상되었고, 휨 철근량을 감소시킬 수 있었다. 기둥 인접부 휨철근의 집중배근을 통해 철근비의 감소 때문에 작아진 강성을 회복시킬 수 있었고, 훌륭한 변형률 분포 및 균열제어 효과를 나타내었다. 또한, 기둥 인접부에 대한 강섬유 보강 콘크리트의 타설은 펀칭 전단강도의 증가와 균열 제어에 탁월한 효과를 보였다. 휨철근비 산정을 위한 유효폭은 기둥면으로부터 슬래브 두께의 2배 이상으로 확대하는 것이 합리적이라 판단된다.
        11.
        2007.07 KCI 등재 서비스 종료(열람 제한)
        풍하중 및 지진하중등 횡하중이 작용하는 무량판 슬래브는 전단파괴와 같은 취성파괴를 지연시키기 위해서 충분한 전단강도와 연성능력을 보유하여야 한다. 본 연구에서는 반복 횡하중을 받는 무량판 슬래브의 전단강도와 변형성능을 고찰하기 위하여, 무보강 및 전단 보강된 총 4개의 내부기둥-슬래브 접합부를 실험하였다. 실험결과, 전단보강 슬래브의 이방향 전단강도는 무보강 슬래브보다 최대 1.5배까지 증가시켜 적용하는 콘크리트구조설계기준(KCI)과 ACI 318-02 기준은 중력하중만이 작용하는 경우에는 적절하나 조합하중 특히 횡하중의 영향이 클 경우에는 매우 불안전측 이었다. 한편, 변형성능 측면에서 슬래브-기둥 접합부의 1.5% 횡변위 성능을 확보하기 위하여 이방향 전단강도에 대한 중력하중비를 40%이하로 제한한 ACI-ASCE 352 위원회의 권고는 안전측인 것으로 나타났다.
        12.
        2007.01 KCI 등재 서비스 종료(열람 제한)
        연구는 플랫 플레이트 구조에서 직사각형 외부기둥-슬래브 접합부의 뚫림전단강도에 관한 실험결과에 관하여 다룬다. 직사각형 기둥의 형상비 증가에 따른 뚫림전단거동을 평가하기 위해 위험단면의 길이를 일정한 값이 되도록 기둥 단면크기를 산정하고 총 8개의 실험체를 계획하였다. 두 수준의 콘크리트 압축강도(f'c=24, 40MPa)에 대하여 기둥단면의 형상비(βc=C1