The importance of Structural Health Monitoring (SHM) in the industry is increasing due to various loads, such as earthquakes and wind, having a significant impact on the performance of structures and equipment. Estimating responses is crucial for the effective health management of these assets. However, using numerous sensors in facilities and equipment for response estimation causes economic challenges. Additionally, it could require a response from locations where sensors cannot be attached. Digital twin technology has garnered significant attention in the industry to address these challenges. This paper constructs a digital twin system utilizing the Long Short-Term Memory (LSTM) model to estimate responses in a pipe system under simultaneous seismic load and arbitrary loads. The performance of the data-driven digital twin system was verified through a comparative analysis of experimental data, demonstrating that the constructed digital twin system successfully estimated the responses.
Existing reinforced concrete building structures constructed before 1988 have seismically-deficient reinforcing details, which can lead to the premature failure of the columns and beam-column joints. The premature failure was resulted from the inadequate bonding performance between the reinforcing bars and surrounding concrete on the main structural elements. This paper aims to quantify the bond-slip effect on the dynamic responses of reinforced concrete frame models using finite element analyses. The bond-slip behavior was modeled using an one-dimensional slide line model in LS-DYNA. The bond-slip models were varied with the bonding conditions and failure modes, and implemented to the well-validated finite element models. The dynamic responses of the frame models with the several bonding conditions were compared to the validated models reproducing the actual behavior. It verifies that the bond-slip effects significantly affected the dynamic responses of the reinforced concrete building structures.
시공 중인 건물은 시공이 완료된 건물과는 다르게 콘크리트의 강도발현이 충분히 이루어지지 않았기 때문에 지진과 같은 자연재해 에 더 취약한 모습을 가질 수 있다. 현재 국내 기준은 건축물의 내진등급별 최소성능 목표를 제시하고 있지만, 설계를 위한 지진하중은 재현주기 2,400년의 지진위험도를 기반으로 한다. 하지만 건물의 시공기간은 건물의 사용기간보다 훨씬 짧기 때문에 재현주기 2,400 년의 지진을 시공 중인 건물에 적용하는 것은 과도하다. 따라서 이 연구는 주거용으로 사용되는 철근콘크리트 건물의 시공 중 지진하 중을 분석하기 위해 5층, 15층, 25층, 60층 건물의 시공단계모델을 작성하고 재현주기에 따라 저감한 지진하중을 적용하여 구조적 안 정성을 확인하였다. 그 결과, 시공기간에 따라 선정한 재현주기의 지진을 적용할 때 구조적 안정성을 확인하였으며, 건물의 규모의 따 라 구조적 안전성을 확보할 수 있는 지진재현주기를 확인하였다.
Vertical earthquake motions can occur along with horizontal earthquakes, so that Structure should be designed to resist Seismic loads in all directions. Especially, due to the dynamic characteristics such as the vibration mode, when the vertical seismic load, the dynamic response of the Spatial structure is large. In this study, the seismic response of the lattice dome to horizontal and vertical seismic loads is analyzed, and a reasonable seismic load combination is analyzed by combining horizontal and vertical seismic response results. In the combination of the horizontal seismic load, the largest result is obtained when the direction of the main axis of the structure coincides with the direction of seismic load. In addition, the combination of vertical seismic load and horizontal seismic load was the largest compared with the combination of horizontal seismic load. Therefore, it is considered that the most reasonable and stable design will be achieved if the seismic load in vertical direction is considered.
The arched stone bridge has been continuously deteriorated and damaged by the weathering and corrosion over time, and also natural disaster such as earthquake has added the damage. However, masonry stone bridge has the behavior characteristics as discontinuum structure and is very vulnerable to lateral load such as earthquake. So, it is necessary to analyze the dynamic behavior characteristics according to various design variables of arched stone bridge under seismic loads. To this end, the arched stone bridge can be classified according to arch types, and then the discrete element method is applied for the structural modelling and analysis. In addition, seismic loads according to return periods are generated and the dynamic analysis considering the discontinuity characteristics is carried out. Finally, the dynamic behavior characteristics are evaluated through the structural safety estimation for slip condition.
This paper relates to the study of load characteristics applicable to wind turbine generators induced by earthquakes. An artificial design earthquake wave generated through the target spectrum and the envelope function of Richter Magnitude Scale (ML) 7.0 as in ASCE4-98 was created. A simulation of earthquake loads were performed according to the design load cases (DLC) 9.5~9.7 of GL guidelines. Additionally, simulation of seismic loads experienced by Wind Turbines installed in the Gyeongju region were carried out utilizing artificial earthquakes of ML 5.8 simulating the real earthquakes during the Gyeongju Earthquakes of Sept. 2016.
Recently, the concept of damped outrigger system has been proposed for tall buildings. But, structural characteristics and design method of this system were not sufficiently investigated to date. In this study, the dynamic response control performance of outrigger damper has been analyzed. To this end, a simplified analysis model with outrigger damper system has been developed. Use the El Centro seismic(1940, NS) analysis was performed. Analysis results, on the top floor displacement response to the earthquake response, did not have a big effect. However, acceleration response control effect was found to be excellent. The increase of outrigger damper capacity usually results in the improved control performance. However, it is necessary to select that proper stiffness and damping values of the outrigger damper system because, the outrigger damper having large capacity is result in heavy financial burden.
This paper briefly introduces the design seismic loads in Korea (KBC 2009). Then, over 10,000 recorded earthquake ground accelerograms, with their magnitude ranging from 4.0 to 8.0 and their epicentral distance ranging from 0 to 200 km, were used to examine the appropriateness of seismic load defined in Korea known as a low-to-moderate seismicity region. The following conclusions are drawn based on the results: (1) The effective peak ground accelerations (EPA) of recorded earthquake accelerograms under M ≤ 6.0 and R ≥15 km appear to be less than that of MCE in Korea for all site conditions defined in KBC 2009. (2) The design spectrum (two-thirds of the intensity of MCE) in KBC 2009 is comparable to those of earthquake records in the magnitude 6 - 7 and the epicentral distance less than 50 km. Therefore, (3) the intensity of Korean design earthquake is considered to be overly high since the Korea peninsula is generally conceived to be a low-seismicity region.
In this study, a series of dynamic centrifuge tests were performed for a soil-foundation-structural interaction system in dry sand with various embedded depths and superstructure conditions. Sinusoidal wave, sweep wave and real earthquake were used as input motion with various input acceleration and frequencies. Based on the results, a natural period and an earthquake load for soil-structure interaction system were evaluated by comparing the free-field and foundation accelerations . The natural period of free field is longer than that of the soil-foundation-structure system. In addition, it is confirmed that the earthquake load for soil-foundation-structure system is smaller than that of free-field in short period region. In contrast, the earthquake load for soil-foundation-structure interaction system is larger than that of free-field in long period region. Therefore, the current seismic design method, applying seismic loading of free-field to foundation, could overly underestimate seismic load and cause unsafe design for long period structures, such as high-rise buildings.
본 연구에서는 기둥을 관통하는 슬래브 하부 철근이 중력하중만으로 설계된 포스트텐션 플랫플레이트 골조의 내진성능에 미치는 영향을 평가하였다. 중 약진 지역에서 건물은 흔히 중력하중만을 고려하여 설계되고 있다. 본 연구에서는 중력하중으로 설계된 PT 플랫플레이트 골조의 내진성능에 집중되고 있다. 이를 위하여, 3,6,9층 PT 플랫플레이트 골조는 중력하중만으로 설계하였다. 철근콘크리트 플랫플레이트 골조에서는 취성적인 붕괴를 예방하기 위해서는 기둥을 관통하는 연속된 슬래브 하부철근이 위치하여야 한다. 그러나 PT 플랫플레이트 골조에서는 슬래브 하부 철근에 대해 ACI 318-05에서는 특별한 언급이 없기 때문에 흔히 생략하고 있다. 본 연구는 대산건물을 비선형 시간이력해석 으로 골조 모델의 내진성능에 대해 평가한다. 비선형 시간이력해석은 6개의 지진과 2개의 다른 위험수준 (475, 2475년 주기), 3개의 다른 지역 (보스턴, 시애틀, LA)을 사용하였다. 해석모델은 PT슬래브-기둥 접합부의 파괴 메카니즘과 비선형 거동을 살펴보기 위해 개발되었다. 본 연구는 중력하중으로 설계된 PT 플랫플레이트 골조가 몇몇 내진저항 능력을 보여주고 있다. 또한, PT 플랫플레이트 골조의 내진성능은 기둥을 관통하는 슬래브 하부철근이 위치할 때 눈에 띄게 향상되었다.
성능에 기초한 내진설계 분야에서 구조물의 내진성능평가를 위해서는 비탄성 지진거동을 보다 정확하게 예즉할 필요가 있다. 성능기초 설계기준에 반영되어 있는 내진성능 평가 방법 가운데 하나인 pushover해석을 이용한 방법은 몇몇 연구자들에 의하여 다양한 해석 방법론이 개발되었다. 이 방법을 사용하여 비탄성 전체 또는 국부적 지진응답을 보다 정확하게 평가하기 위해서는 사용되는 횡하중 분배가 구조시스템과 지반운동의 동적특성에 부합되도록 반영되어야 한다. 그리고 구조물의 변형능력을 합리적으로 평가하여 성능점을 보다 정확하게 산정해야 한다. 본 연구에서는 개선된 적응적 횡하중 분배방법과 건물의 등가응답을 이용하여 비탄성 지진응답을 정확하고 효율적으로 평가할 수 있는 방법을 제안하였다. 제안된 방법은 건물의 전체 비탄성 거동에 대한 내진성능을 평가하고 국부적인 비탄성 지진응답을 정확하게 산정하는데 사용될 수 있다. 또한 제안된 방법의 정확성과 타당성을 검증하기 위해서 비탄성 시간이력해석과 기존의 다른 해석방법들에 의한 비탄성 지진응답과 비교하였다.
Sliding mode control(SMC) keeps responses of a structure in sliding surface when the structure is stable. Recently, this method has been investigated for application to seismically excited civil engineering structures because it can design both linear controller and non-linear controller such as bang-bang controller. This paper presents vibration control of the SDOF system using saturated sliding mode controller, of which maximum conrtol force is limited. It is assumed that the response of a structure is stationary random process and control dampers do not affect the modal shapes, and the structure has proportional damping. SMC method can be used to get the equivalent damping ratios of a SDOF system with non-linear control dampers such as friction dampers as well as linear control dampers. The determinated equivalent damping ratios and numerical simulation results indicate that the performance of saturated SMC method is verified.
내진상세가 적용되지 않은 철근콘크리트 교각의 거동특성 및 내진성능을 살펴보기 위해서 축소교각모형실험을 수행하였다. 횡방향 철근이 심부를 구속할 만큼 충분히 배근되어 있지 않은 중심 원형 단면의 실교각을 대상으로 기초 상단의 소성 힌지 부위에서 겹침이음이 된 주철근을 사용했을 때와 연속철근을 사용했을 경우로 구분되도록 철근상세를 결정하였다. 이에 따라 3기의 축소교각시험체를 제작하여 수직방향 축하중을 가한 상태에서 준정적 반복하중을 재하하는 실험을 수행하였다. 실험결과를 통해서 겹침이음이 있는 교각시험체는 연성거동을 하지 않지만, 겹침이음이 없이 연속철근을 사용한 교각시험체는 어느 정도의 한정연성거동을 하는 것으로 분석되었다.
이 연구는 지진 시 철근콘크리트 교각의 비탄성 거동 및 연성능력을 해석적으로 파악하는데 그 목적이 있다. 재료적 비선형성에 대해서는 균열 콘크리트에 대한 인장, 압축, 전단모델과 콘크리트 속에 있는 철근 모델을 조합하여 고려하였다. 이에 대한 콘크리트의 균열 모델로서의 분산균열모델을 사용하였다. 두께가 서로 다른 부재간의 접합부에 단면강성이 급변하기 때문에 생기는 국소적인 불연속변형을 고려하기 위한 경계면 요소를 도입하였다. 또한, 축방향철근의 유무 및 그 양 등에 따른 구속효과를 적절히 표현할 수 있는 해석 모델을 개발하였다. 본 연구에서는 철근콘크리트 교각의 비탄성 거동 및 연성 능력의 파악을 위해 제안한 해석기법을 신뢰성 있는 연구자의 실험결과와 비교하여 그 타당성을 검증하였다.
본 논문에서는 일반적으로 사용되고 있느 면진건축물의 내진설계기준에 대한 타당성을 검증하고 새로운 층지진하중 산정식을 제안하였다 UBC-91의 층지진하중 산정식은 충분한 안전성을 가지지 못하였으므로 94년에 개정이 되었다 그러나 개정된 산정식도 고정기초건축물과 유사한 층지진하중 산정식을 사용하였으므로 비경제성이 문제점으로 지적되고 있다 그러므로 제안된 식에서는 2자유도계 면진건축물과 고정기초건축물의 모드형상을 이용하여 안전성, 경제성 및 적용성을 만족시키도록 하였다. 제안된 층지진하중 산정식의 정확성 및 적용성을 검증하기 위하여 코멘트저항 골조형식과 전단변 구조형식의 구조물의 예제해석을 수행하였으며 동적해석의 경우와 근접한 결과를 얻었다.
건물의 고층화가 이루어지면서 구조부재에 미치는 축력이 증가하게 되고 축소현상을 발생시킨다. 이러한 축소현상은 구조물의 사용헝 저하를 가져올뿐만아니라 2차 응력 발생으로 구조물 자체의 안전에도 영향을 미친다. 수직구조부재의 축소량을 예측하는 목적은 인접 부재간의 부등축소를 보정하는 데 있다 본 논문에서는 시공과정에서만 보정을 실시한 경우와 설계단계에서 축소량을 예측하여 보정을 한 경우에 대해 각각 지진하중을 적용하여 구조부재에 미치는 영향에 대해 비교.검토를 하였으며 수직구조부재의 축소량은 반드시 예측되어 보정을 실시하여야 하는 것으로 나타났다.
현재 국내에는 조적조 건물에 대한 내진규준이 마련되어 있지 않다 반면 최근 들어 한반도에 발생하는 지진의 반도수는 계속증가하고 있어 조적조 건물에 대한 지진하중에 의한 평가가 이루어져야 한다. 본 연구에서는 2층 조적조 건물에 국내에서 발생 가능한 최대지진가속도인 0.12g의 지진하중을 적용한 유한요소해석법에 의한 방법으로 동적해석을 수행한 결과 2층에 비하여 1층에서 불안전한 거동이 발생하였다 특히 개구부 주위 및 테두리 보와 조적벽의 경계부분에서 허용응력을 초과하여 균열이 발생함을 알 수 있었다.
대도시에서 초고층 건물의 필요성은 구조 기술자에게 새로운 문제를 안겨주었다. 기둥축소의 효과는 설계 및 시공에 있어 특별한 주의를 요구한다. 기둥의 축소는 칸막이, 마감, 그리고 설비체계와 같이 수직하중을 지탱하도록 고려되어 있지 않은 비구조적인 요소에 영향을 미친다. 또한 각 기둥의 축소량 차이는 주위의 슬래브 및 보와 같은 부재들을 경사지게 한다. 축소량을 예측하는 목적은 부등 축소량의 차이를 미리 보정하는데 있다. 본 연구는 부동 축소량에 의한 주구조부재의 영향에 대한 내용을 다루었다. 자중으로 인해 초지 수직변위를 갖는 52층 철근콘크리트 구조물에 지진하중을 적용하여 구조물에 미치는 영향을 평가하였다. 각 수직구조요소에 대한 축소량은 전산화된 기둥축소 해석 프로그램을 이용하여 예측되었으며 지진하중으로 인한 축소량이 보정된 구조물과 보정되지 않은 구조물 사이의 응력을 조사하였다.
일반적으로 구조물 의 내진설계에 있어서는 동가정적해석볍이 주고 사용되고 있다. 현재 사용되고 있는
풍 가정적해석법 은 구조물의 거통이 주로 기본진동 모드에 의해 지배된다는 가정하에 유도되었으므로
기본진동 주기가 낀 구조 불 에 대해서는 구조물의 동적 특 성 을 정확하게 예촉하기가 어렵다.
본 연구에서는 구조불의 설계시 직접적인 영향올 미치게 되 는 충 전 단력의 분포를 주요 관점으로하여
구조물 의 동적특성에 미치는 고차모 드 의 영향을 정확히 고려할 수 있는 충지진하중에 대하여 연구했다.
층 지 진 하중의 분포를 개선하기위해 현행 내진설계 기준의 등 가정적해석법에서 쓰이는층지진하중과모드
해석 을 이용하여 얻은 충지진하중의 차이를 파악하고 이로 부 터 고자모드의 영향이 고려된 충 지진하증 의
분포 룹 제안했다.
Many of recent field observations and researches have been shown that axial force variation due to vertical ground motion can affect the shear capacityRC column . However, the majority of shear strength models of RC columns in current design codes and predictive approaches have been developed based on experiments with constant axial loads. Thus, this paper evaluates the experimental seismic performance of RC columns subjected to varying axial loads. The axial loading patterns included constant and variable loading considering the characteristic of overturning moment and vertical ground motion. The observations of experimental results, including the effect on shear strength, and ductility are discussed compared with the case of constant axial load.