현재 국내 복공판 관련 규정에는 장지간 복공판에 대한 규정이 부족하고, 복공판의 피로에 대한 별도의 규정도 없는 실정이 다. 장지간 복공판의 성능검증은 피로하중에 대한 구조성능 및 사용성에 대한 검증이 필요하다. 본 연구는 복공판의 장지간화를 위한 연구의 일환으로 수행된 실험적 연구로 피로하중을 받는 장지간 복공판의 단면형상 차이와 하중 재하조건 차이에 따른 응력분 포 특성을 파악하는데 목적이 있다. 실험 결과, 200만회 피로실험 후에도 처짐은 허용처짐의 1.22∼1.45배, 응력은 허용응력의 1.55∼1.56배 범위에 분포하고 있는 것을 확인하였다.
In this study, the characteristics of wind pressure distribution on circular retractable dome roofs with a low rise-to-span ratio were analyzed under various approaching flow conditions by obtaining and analyzing wind pressures under three different turbulent boundary layers. Compared to the results of previous studies with a rise-to-span ratio of 0.1, it was confirmed that a lower rise-to-span ratio increases the reattachment length of the separated approaching flow, thereby increasing the influence of negative pressure. Additionally, it was found that wind pressures varied significantly according to the characteristics of the turbulence intensity. Based on these experimental results, a model for peak net pressure coefficients for cladding design was proposed, considering variations in turbulence intensity and height.
This study was conducted to prepare a plan for the controlling indoor microclimate environment using natural ventilation for the single-span plastic greenhouses, which account for about 83.8% of the total area of horticultural greenhouses in South Korea. The changes of indoor air temperature and relative humidity according to the side opening height were experimentally compared and analyzed in the experimental greenhouse. As the side opening height was changed to 30, 70, and 110cm, the indoor and outdoor temperature differences were found to be 14.0, 10.1, and 7.7℃, respectively. The indoor and outdoor relative humidity differences were found to be -15.7, -12.5, and -11.1%, respectively. These results were verified for statistical significance by ANOVA. When the variable breadth of the outdoor temperature was 6.9℃, the indoor temperature breadths were 14.5, 12.3, and 9.0℃, and when the outdoor relative humidity breadth was 24%, the indoor relative humidity breadths were 31.2, 28.0, and 23.8%, respectively. It was analyzed that as the side opening height is increased, the indoor temperature and relative humidity become similar to the outdoor environment. This is because the air is mixed by active indoor-outdoor air movement of greenhouses with natural ventilation. The results indicated that the proper opening and closing of side openings is necessary for the stable indoor microclimate environment control of plastic greenhouses.
This study aimed to develop an optimal greenhouse model for strawberry seedling during the summer high-temperature period based on the results of field surveys. We conducted a survey on the structure types of 46 strawberry seedling farms nationwide, including width, ridge height, eaves height, ventilation method, seedling bed width, and spacing. Based on the survey results, we derived the optimal greenhouse model by considering various factors. The greenhouse width was set at 14 meters to maximize the efficiency of seedling beds and overall space. The height was determined at 2 meters, taking into account ventilation during the summer season. To reduce stress on the supporting structure due to snow loads, we established a reinforcement installation angle of 50 degrees. We analyzed two different models that use support beams with dimensions of φ48.1×2.1t and φ59.9×3.2t, respectively, to ensure structural safety against meteorological disasters, considering regional design wind speeds and snow accumulation. We utilized these developed greenhouse model to conduct strawberry seedling experiments, resulting in a high survival rate of average 93.2%. These findings confirm the usefulness of the strawberry seedling greenhouse in improving the seedling environment and enhancing overall efficiency.
이 논문에서는 보행교의 진동 사용성 평가에 있어서 보행자의 이동 질량 관성 효과의 고려 여부, 보행 패턴 등을 고려한 보행 시나 리오 등에 따른 해석 결과를 제시하고, 그에 따라 보행교 설계 단계에서 동적 유한요소 해석을 통한 진동 사용성 평가에 있어 적절한 해석 방법과 유의점을 제안한다. 지간 40m의 강합성 박스 단면을 갖는 단경간 단순교 형식의 보행교에 대하여 보행자 밀도, 보행 속 도, 임의 보행, 동기화 보행 등을 고려한 보행 시나리오에 대한 가속도 응답을 분석한다. 해석 결과 고정 질량 해석 방법은 임의 보행 시 나리오 해석에서 이동 질량 해석과 큰 차이를 보이지 않으며 진동 사용성 평가시에는 더 넓은 진동수 대역을 가진할 수 있는 임의 보행 시나리오를 고려하는 것이 바람직할 수 있음을 보였다.
본 연구에서는 연동온실의 골조로 인한 내부 광 분포를 검토 하기 위하여 위치별(중앙부 및 측면부) 일사량을 실측하고, 오 전(08:30-12:30)과 오후(12:35-16:30)로 시간대를 구분 하여 일사량, 광 투과율 및 일 적산일사량을 분석하였다. 또한 토마토의 생육 및 수확량을 위치별로 비교하였다. 오전일 때 중앙부와 측면부의 일사량은 각각 275.2W·m-2, 314.9W·m-2 이고, 오후일 때는 각각 278.1W·m-2, 313.9W·m-2로 측면부 보다 중앙부가 오전은 12.6%, 오후는 11.4% 낮았고, 광 투과 율과 일 적산일사량도 중앙부가 낮게 나타났다. 생육 특성에 있어서는 첫 번째 조사의 엽장과 엽폭을 제외하고는 조사 종 료일까지 유의미한 차이가 없었다. 토마토의 최종 주당 평균 수확량은 재배 위치에 따라 중앙부 4,828g, 측면부 4,851g으 로 유의미한 차이는 없었고, 중앙부가 0.5% 적게 나타났다. 토 마토의 광보상점은 60W·m-2이고 광포화점은 281W·m-2로 중앙부의 시간대별 일사량은 광보상점보다는 높고, 광포화점 보다는 낮으나 그 차이가 크지 않아 온실 내 위치에 따른 생육 및 수확량의 차이가 미미한 것으로 판단하였다. 향후 이 검토 결과를 포함하여 온실을 설계할 때 광 환경을 고려한 설계를위해 온실의 설치 방향, 위치 및 지붕 경사도 등에 따른 온실 내 광 분포 분석이 필요하다.
본 연구에서는 실대형 실험과 구조해석을 통해서 현장에서 사용되는 가새 시스템을 적용한 강관 골조 플라스틱 연동온실 의 횡하중 가력시험을 수행하고 성능을 분석하였다. 횡강성 과 응력을 분석하기 위해 실험체에 변위와 변형률계를 각각 9 개소 및 16개소 설치하였으며 가새의 설치 유무에 따른 성능 을 비교하기 위해 구조해석을 수행하였다. 실대형 실험과 가 새의 설치 유무에 따른 구조해석 결과 비교에서 구조물의 횡 강성이 많은 차이를 보였다. 실험체의 측고 부근에서 측정한 횡강성은 가새 시스템을 설치함으로 강성을 최대 44%까지 증 가시켰다. 현장에서 사용하는 가새의 접합부가 충분한 강성 을 확보하지 못함으로써 외력을 전체 구조물에 적절히 전달하 지 못하여 횡강성이 구조해석 결과보다 많이 저하되는 현상이 나타났다. 따라서 온실 설계 시 구조성능의 신뢰성을 높이기 위해서 가새 시스템의 연결방법, 설치위치, 부재의 최대길이 등 온실의 접합부에 대한 명확한 시공방법과 설계기준이 정립 되어 온실 설계가 이루어져야 할 것으로 판단된다.
본 연구는 권취식 측창을 갖는 아치형 단동 플라스틱 온실 내 강제환기장치 설치 및 운용, 환기 성능 개선방안 등을 제안 하기 위해 온실 내부에 유동팬과 배기팬을 설치하여 강제환기 장치 사용에 따른 온실 내부기온 강하 특성을 정량적으로 조 사하였다. 시험은 3가지 환기 조건(측창, 측창+순환팬, 측창+ 순환팬+배기팬)에서 수행되었다. 각 조건 데이터로거를 이용 하여 환기 시작과 동시에 온실 내외부 기온 및 외부환경 변화 를 측정·기록하였고, 환기 방식별 기온차 변화의 평균값으로 부터 정규기온차를 계산하여 기온 강하 효과를 비교하였다. 오전(11:00-12:00)에는 환기 방식에 상관없이 환기 초반 정 규기온차가 일시적으로 증가했다가 감소하는 것으로 나타났 다. 강제환기장치가 더 많이 사용될수록 최대 정규기온차는 1.158에서 1.037로 감소하였고 최대 정규기온차에 도달하는 시간도 340초에서 110초로 단축되었다. 강제환기장치의 사 용은 정규기온차가 0.8까지 감소하는데 소요된 시간을 1,030 초에서 550초로, 0.6까지는 1,610초에서 915초로, 0.4까지는 2,315초에서 1,360초로, 자연환기의 약 60% 수준으로 감소 시켰다. 오후(14:00-15:00)에는 정규기온차의 증가가 관측되지 않았지만, 환기 시작과 동시에 기온차가 감소하기 시작 했다. 또한 강제환기장치가 더 많이 사용될수록 정규기온차 가 0.8까지 내려가는 시간을 560초에서 345초로, 0.6까지는 825초에서 540초로, 0.4까지는 560초에서 345초로, 약 70% 수준으로 감소시켰다. 따라서, 보다 효과적이고 경제적인 환 기를 위해 강제환기장치는 오전과 같이 열부하가 높은 환경에 서 적극적으로 사용하는 것이 바람직하다고 판단된다.
This study was carried out to investigate the effect of side vent heights on temperature and relative humidity inside and outside the single-span plastic greenhouse (W: 7 m, L: 40 m H: 3.9 m) during natural ventilation. Four different heights (120, 100, 80, 60 cm) of the side vent were used as an experimental condition. Variations of temperature and relative humidity inside and outside the greenhouse and the differences between heights were compared by using one-way ANOVA. In the daytime, the difference in temperature between inside and outside the greenhouse was dropped from 14.0°C to 7.1°C as the side vent height increased. The temperature difference in the nighttime was less than 0.2°C regardless of the height. One-way ANOVA on the temperature difference between heights presented that the statistical significance was founded between all of the combinations of height in the daytime. The difference in relative humidity between inside and outside the greenhouse was grown from –13.8% to – 22.2% with a decrease in the side vent height. The humidity difference in the nighttime was less than 1% regardless of the height. One-way ANOVA on the humidity difference revealed that most of the side vent heights showed significance in the daytime but between 100 and 80 cm was not significant. It seemed because the external air became cooler during the experiment with a height of 80 cm. Conclusively, this study empirically demonstrated that the higher side vents resulted in the decrease of differences in temperature and relative humidity between inside and outside the greenhouse, and also the effect of side vent height was statistically significant. This study may be helpful for deciding the height of the side vent effective for controlling temperature and relative humidity in a single-span greenhouse during natural ventilation.
이 연구는 바잘트 섬유시트로 전단보강한 철근콘크리트 보의 전단경간비에 따른 구조물의 구조적 거동을 실험을 통해 확인하였다. 철근콘크리트 보의 전단보강은 무보강, 45도, 90도, U형보강을 변수로 두었으며 전단경간비에 따른 실험결과 U형으로 보강하였을 때 철근콘크리트 보의 전단보강효과가 높음을 확인하였다.
본 연구는 고온기 원예작물의 안정 생산을 위해 대형 단동하우스 ‘사계절하우스’를 파프리카 재배에 활용 시 시설 내부 기상 환경 및 파프리카 품종별 생육, 수량, 품질 등을 분석하고 근권냉방 효과 등을 구명하여 파프리카 재배환경 조건을 최적화 하기 위한 기초자료로 사용하고자 수행하였다. 정식 후부터 재배 종료 시점(2020년 5-11월)까지 시설내 평균 적산광량은 12.7MJ·m -2 d -1로, 온실외부의 평균 광량인 14.1MJ·m -2 d -1의 90% 수준으로 나타났다. 일 년중 가장 기온이 높은 7-8월의 온실내 24시간 평균온도는 외기보다 3.04℃ 낮았고, 장마가 끝난 8월 12일 이후에는 평균 4.07℃ 낮게 나타났다. 시설 내 포그 냉방 가동(6월 13일) 이전 일평균 상대습도는 최저 40% (주간 20%) 수준까지 떨어져 작물재배에 적합하지 않은 상태였으나 포그를 가동한 이후 주간 상대습도는 70-85% 수준으로 증가된 것으로 나타났다. 평균 수분부족분(humidity deficit)은 포그 공급전에는 최고 12.7g/m 3 까지 상승하여 매우 건조한 조건이었으나, 포그 공급 후 고온기(7-8월)에 평 균 3.7g/m 3으로 감소하였고, 저온기(10-11월)로 갈수록 다시 증가되는 경향이었다. 주간 잔존 CO2 농도는 전체 재배기 간동안 평균 707ppm으로 나타났다. ’20년 7월 27일부터 11월 23일까지 수확한 파프리카의 품종별 상품수량(kg/10a)은 주황색 품종 ‘DSP-7054’과 황색 품종 ‘Allrounder’이 각각 14,255kg/10a와 14,161kg/10a로 다른 품종에 비해 높았고, 다음으로 주황색 ‘K-Gloria orange’, 황색 ‘Volante’, 적색 ‘Nagano’ 품종 순으로 나타났다. 사계절하우스에서 고온기(8 월)에 생산된 대과종 파프리카의 품종별 과실품질 특성을 조사한 결과, 과고, 과폭, 과실당도, 과육두께에서 품종 간 유의성이 인정되었다. 당도는 주황색 품종인 ‘DSP-7054’와 ‘Naarangi’에서 높게 나타났고, 과육두께는 황색과 주황색 품종인 ‘K-Gloria orange’와 ‘Allrounder’에서 높게 나타났다. 근권 냉방처리 기간 동안 배지내 일평균 온도는 20.7℃로 나타났고, 근권 난방처리 기간 동안 배지내 일평균 온도는 23. 4℃로 나타났다. 근권부 냉난방 처리를 통해 상품수량은 무처리구에 비해 비해 ‘Nagano’ 16.5%, ‘Allrounder’ 1.3%, ‘Naarangi’ 20.2%, 및 ‘Raon red’ 17.3% 증가하였고, 품종 전체로는 16.1% 증가하였다. 근권 냉난방처리에 의해 과실의 경도는 4개 품종 평균 5.7% 증가하였으나 다른 품질 지표에서는 유의성있는 차이가 나타나지 않았다.
본 연구에서는 원예특작시설 내재해형 규격서에 등록되어 있는 폭이 넓은 단동온실(10-단동-5형)을 대상으로 기초의 경계조건과 서까래 강관의 이음 유무에 대해 실물 크기 실험을 실시하고 그 결과를 수치해석 결과와 비교하여 이음부가 있을 때 구조성능 차이에 대해 알아보았다. 각 측정 위치별 변위를 실험에서 측정한 값과 수치해석으로 예측한 값을 비교한 결과에서는 기초의 조건 및 서까래 강관 이음 유무에 상관없이 모두 상당한 차이를 보였고, 힌지 조건 보다 고정 조건이 상대적으로 차이가 컸다. 그리고 모든 절점을 강접합으로 가정하고 구조해석한 결과를 구조실험과 비교한 결과에서는 힌지조건이 고정조건 보다 잘 일치하였지만 해석값이 실험값 보다 크게 나타났다. 수치해석은 모든 절점을 강접합으로 가정했기 때문에 실제 성능과 달랐다. 따라서 현재 모든 절점을 강접합 으로 가정하고 온실을 설계를 하면 과소설계될 우려가 있어 앞으로 신뢰성 높은 온실 설계를 위해서는 서까래와 도리가 교차하는 교차부 성능 특성을 고려한 구조해석 기술 개발이 이루어져야 할 것으로 판단된다.
본 연구는 최근 지자체를 중심으로 경쟁적으로 건설되고 있는 장대 보도교를 대상으로 바닥판에 설치된 그레이팅의 배치 형태에 따른 풍응답특성을 파악하여 내풍설계의 기초자료를 확보함을 목표로 한다. 변장비 1:12.5의 플레이트거더단면을 대상으로 그레이팅의 배치방법과 설치면적을 달리한 10종류의 단면을 선정하여 연직-비틀림 2자유도 탄성지지상태에서 동적 풍응답실험을 수행하였다. 바닥판 중앙에 그레이팅을 둔 경우 전체 폐쇄단면과 비교할 때, (-)영각에서는 플러터 한계풍속이 증가하였으나 (+)영 각에서는 감소하는 것으로 나타났으나 바닥판 가장자리에 개구부를 둔 단면의 경우는 조사풍속영역에서 전반적으로 안정적인 내풍성을 가지고 있는 것으로 확인되었다. 실험 결과를 종합하면, 단면 중앙에 개구부를 설치하는 경우 유해진동의 발생이 예측되므로 적절한 내풍대책이 강구되어야 될 것으로 판단되며 개구부를 바닥판 가장자리에 두는 것이 내풍안정성확보에 유리한 배치임을 확인할 수 있었다.
본 연구는 단조가력 하중을 받는 실물크기 비닐온실의 기둥-서까래-도리 접합부의 역학적거동을 알아보기 위해 현장에서 시공되고 있는 두 가지 형식의 실험체로 구조실험을 수행하였다. 실험결과를 바탕으로 두 가지 형식의 접합부에 대해서 휨성능을 분석하고 접합부 분류를 시도하였다. Type B 는 Type A에 비해 휨 성능이 77% 수준으로 나타났으며 두 형식 모두 강성 및 휨내력이 강접합 수준에 미치지 못하는 것으로 나타났다. 기둥-서까래-도리 접합부의 거동은 용접부 및 체 결구 변형에 의한 국부좌굴이 지배적이었다. AISC 기준에 의한 접합부 분류 결과, Type A와 B 접합부 모두 설계 시 가정하는 강접합 성능에 미치지 못하는 결과를 보였으며 단순 접합으로 분류되는 것으로 나타났다. 따라서 접합부 성능평가 및 분류 결과, 접합부 성능을 고려한 온실 설계가 이루어져야 하며 신뢰성 높은 온실 구조설계를 위해서 온실 접합부에 대한 명확한 설계기준 정립 연구가 필요할 것으로 판단된다.
본 연구의 대상은 도로 폭이 좁은 시가지에서 굴착공사 시 적용되는 장지간 주형의 연결부이다. 일반적으로 적용되고 있는 연결부에서 상부 플랜지의 단차와 피로균열 등의 문제로 연결부의 신뢰도가 저하된다. 연결부의 결함을 보완하고 안전성을 향상시킨 개선형 연결부를 개발하였다. 유한요소 기반의 상용프로그램(ABAQUS)를 이용하여 개선형 연결부의 거동을 평가하였다. 먼저, 개선형 연결부에 적용되는 고장력 볼트 연결 및 강재와 콘크리트의 합성거동을 구현하기 위한 수치해석 방법을 제안하였다. 비교논문의 실험결과와 수치해석 결과의 비교를 통하여 개선형 연결부를 해석하는데 있어 수치해석 방법의 적합성을 검증하였다. 본 연구에서 제 안하는 수치해석 방법을 적용하여 개선형 연결부와 일반형 연결부가 적용된 장지간 주형을 해석하였다. 장지간 주형의 탄소성 거동과 연결부의 응력분포를 수치 해석적으로 비교분석하였다. 개선형 연결부의 도입으로 25%의 압축응력이 감소되며 구조적 성능 개선 효과 및 안전성을 확인하였다.
본 논문에서는 풍하중에 노출된 강재 및 CFRP로 구성된 비닐하우스에 대한 확률론적 성능비교를 하였다. 풍하중에 대한 취약성은 강풍에 노출된 온실의 파괴확률을 추정하기 위해 사용되었으며 단동 비닐하우스의 유한요소 모델링은 한국농촌 경제연구원에서 발간한 설계도를 적용하였다. 해석결과를 구조물의 한계상태와 비교함으로써 비닐하우스의 파괴상태를 결정할 수 있다. 기본적으로 몬테카를로 시뮬레이션은 풍속에 따른 파괴확률을 도출하기 위해 가상의 풍하중에 대하여 적용하지만 본 논문에서는 전체에 대한 수직 및 수평 변형한계상태를 고려하였다. 그 결과, 강재 비닐하우스가 가장 높은 성능을 보였으며 수평 변형 한계상태가 하중조건에 대한 단동비닐하우스의 파괴원인임을 확인하였다.
본 연구는 일정한 풍환경하에 온실 피복재 관류전열손실을 분석하기 위하여 온실 열손실 분석용 소형 풍동을 제작하고 그 성능을 분석하였으며 모형온실을 적용하였을 때의 관류전열손실을 분석하였다. 소형 풍동은 시험부 측 공기흐름이 정상상태를 유지하고 편차를 최소화하기 위하여 풍동의 각 요소를 반영하여 구성하였으며 송풍부, 확산부, 정류부, 축소부, 시험부로 구성하였다. 소형 풍동의 형태는 개방형, 토출식으로 결정하였고, 시험부 규격은 제작하고자 하는 모형온실의 규격과 상사비율, 시험부의 단면 폐쇄율을 감안하여 결정하였다. 상사비율을 풍동실험에 적용할 모형은 농업시설 중 가장 큰 비중을 차지하고 있는 단동 비닐온실을 대상으로 하였다. 소형풍동 내 풍속을 조절함에 따라 나타나는 모형온실 피복재의 관류전열계수는 피복재 면을 크게 지붕면과 측벽면, 앞뒷면으로 나누고 각 면별 계측 데이터를 평균 내어 산출하였다. 지붕면은 풍속이 증가함에 따라 전열계수도 증가하나 증가폭이 감소하는 구간은 배치각도에 따라 1-2ms-1과 2-3ms-1으로 구분되어지는 것으로 판단되었다. 측벽면의 전열계수가 증가하는 폭이 큰 구간은 0-1ms-1 구간인 것으로 판단된다.