The ductility of the system based on the capacity of each structural member constituting the seismic force-resisting system is a significant factor determining the structure’s seismic performance. This study aims to provide a procedure to supplement the current seismic design criteria to secure the system’s ductility and improve the seismic performance of the steel ordinary moment frames. For the study, a nonlinear analysis was performed on the 9- and 15-story model buildings, and the formation of collapse mechanisms and damage distribution for dynamic loads were analyzed. As a result of analyzing the nonlinear response and damage distribution of the steel ordinary moment frame, local collapse due to the concentration of structural damage was observed in the case where the influence of the higher mode was dominant. In this study, a procedure to improve the seismic performance and avoid inferior dynamic response was proposed by limiting the strength ratio of the column. The proposed procedure effectively improved the seismic performance of steel ordinary moment frames by reducing the probability of local collapse.
본 논문에서는 휨 항복 메커니즘을 기반으로 한 강재이력 댐퍼를 제안하기 위한 해석 및 실험적 연구를 수행하였다. 댐퍼는 휨모멘 트에 의한 항복거동을 하도록 설계된 일련의 댐핑 플레이트로 구성된다. 실험 결과와 유한요소해석 결과의 비교를 통해서 본 연구에 서 채택된 해석적 접근방식이 댐핑 플레이트의 형태 및 상세에 대한 민감도 연구를 수행하기에 적절함을 확인하였다. 최초에 제안된 댐퍼는 휨 항복 메커니즘을 기반으로 작동하는 것으로 고안되었으나, 댐핑 플레이트의 인장 거동에 대한 기여도가 상당할 수 있음을 관찰할 수 있었다. 댐핑 플레이트의 두께가 증가함에 따라 휨 항복에 의한 에너지 흡수량이 증가한다. 댐핑 플레이트의 두께가 감소함 에 따라 인장에 의한 댐퍼의 비선형 거동 기여도가 증가하고 좌굴 발생으로 인하여 이력곡선의 형상이 댐퍼로서 불리해진다.
The energy dissipation of inverted V-type eccentric steel braced frames can be achieved through the yielding of a slit link, through yielding of a number of strips between slits when the frame is subjected to inelastic cyclic deformation. On the other hand, the development of seismic resistance system without residual deformation is obtained by applying the superelasdtic shape memory alloy (SMA) material into the brace and link elements. This paper presents results from a systematic three-dimensional nonlinear finite element analysis on the structural behavior of the eccentric bracing systems subjected to cyclic loadings. A wide scope of structural behaviors explains the horizontal stiffness, hysteretic behaviors, and failure modes of the recentering eccentric bracing system. The accurate results presented here serve as benchmark data for comparison with results obtained using modern experimental testing and alternative theoretical approaches.
본 논문에서는 중심가새골조의 내진성능 향상을 위한 전단항복 댐퍼의 개발을 수행하였다. 실용성이 높은 댐퍼의 개발을 위해서 구조적 간결성과 내진성능의 신뢰도에 중점을 둔 상세를 제시하기 위해 노력하였다. 지진 발생 시 에너지 소산 메커니즘에 대한 신뢰 도가 높고, 지진 발생 후 항복 부위의 교체가 쉬운 형태로 고안되었다. 댐퍼의 끼움강판 치수를 변경함으로써 전단, 휨-전단, 휨 메커니 즘을 조절하여 설계할 수 있다. 비선형 유한요소해석을 통해서 댐퍼의 항복 메커니즘에 따른 구조적 거동을 분석하였고, 전단항복 메 커니즘 댐퍼가 휨항복 메커니즘 댐퍼에 비해 강성, 강도, 에너지 소산 측면에서 우수한 성능을 가지고 있음을 확인하였다.
In seismic design standards such as KDS 41 17 00 and ASCE 7, three procedures are provided to estimate seismic demands: equivalent lateral force (ELF), response spectrum analysis (RSA), and response history analysis (RHA). In this study, two steel special moment frames (SMFs) were designed with ELF and RSA, which have been commonly used in engineering practice. The collapse probabilities of the SMFs were evaluated according to FEMA P695 methodology. It was observed that collapse probabilities varied significantly in accordance with analysis procedures. SMFs designed with RSA (RSA-SMFs) had a higher probability of collapse than SMFs designed with ELF (ELFSMFs). Furthermore, RSA-SMFs did not satisfy the target collapse probability specified in ASCE 7-16 whereas ELF-SMFs met the target probability.
This paper presents a systematic numerical analysis to obtain the re-centering and energy dissipation capacities of Chevron braced steel frames subjected to seismic loadings. In order to develop a recentering seismic resistance system excluding a residual deformation, the chevron braced steel frames are assembled using super-elastic SMA (Shape Memory Alloy) braces. The three-dimensional nonlinear finite element models are constructed to investigate the horizontal stiffness, hysteretic behaviors, and failure modes of the re-centering Chevron bracing system.
In this paper a systematic numerical analysis is performed to obtain the energy dissipation and re-centering capacities of diagonal steel braced frames subjected to cyclic loading. This diagonal steel bracing systems are fabricated with super-elastic SMA (Shape Memory Alloy) braces in order to develop a recentering seismic resistance system without residual deformation. The three-dimensional nonlinear finite element models are constructed to investigate the horizontal stiffness, drifts and failure modes of the re-centering bracing systems.
미국의 내진설계기준인 ASCE/SEI 7-10은 구조물 붕괴성능에 대한 불확실성을 고려하지 않는 등재해도 기반 내진설계의 문제점을 해결하기 위해 위험도 기반 내진설계 개념을 도입하였다. 하지만 현행 국내 내진설계기준의 경우 한반도 내에서 발생한 큰 규모의 지진기록과 구조물의 붕괴성능과 관련된 연구의 부족으로 위험도 기반 내진설계 개념을 반영하지 않고 있 다. 본 연구에서는 철골 보통중심가새골조를 표본건물로 선정하여 위험도 기반 내진성능평가를 수행하였다. 건물이 위치한 지역, 높이, 지반조건을 변수로 바탕으로 표본건물에 대한 붕괴성능 평가를 수행하였으며, 국내 지진기록의 특성을 반영할 수 있는 경험적 스펙트럴 형상 예측 모델을 활용하여 지진재해도 곡선을 작성하였다. 이를 활용하여 국내 주요 도시에 위치 한 철골 보통중심가새골조의 붕괴확률을 위험도 적분 개념에 따라 평가하였다. 국내 주요 도시에 위치한 철골 보통중심가새 골조의 붕괴확률을 평가한 결과, 현행 건축구조기준에 따라 설계된 표본건물은 본 연구에서 고려한 해석 변수에 따라 붕괴 확률에 상당한 차이를 보였다. 특히 국내 건축구조기준의 경우 철골 보통중심가새골조에 대한 높이제한이 없어 일부 고층 표본건물에서 목표 위험도인 50년간 1%의 붕괴확률을 초과하는 것으로 평가되었다.
This paper presents the resizing method of columns and beams that considers column-to-beam strength ratios to simultaneously control the initial stiffness and ductility of steel moment frames. The proposed method minimizes the top-floor displacement of a structure while satisfying the constraint conditions with respect to the total structural weight and column-to-beam strength ratios. The design variable considered in this method is the sectional area of structural members, and the sequential quadratic programming(SQP) technique is used to obtain optimal results from the problem formulation. The unit load method is applied to determine the displacement participation factor of each member for the top floor lateral displacement; based on this, the sectional area of each member undergoes a resizing process to minimize the top-floor lateral displacement. Resizing members by using the displacement participation factor of each member leads to increasing the initial stiffness of the structure. Additionally, the proposed method enables the ductility control of a structure by adjusting the column-to-beam strength ratio. The applicability of the proposed optimal drift design method is validated by applying it to the steel moment frame example. As a result, it is confirmed that the initial stiffness and ductility could be controlled by the proposed method without the repetitive structural analysis and the increment of structural weights.
Seismic design of braced frames that simultaneously considers economic issues and structural performance represents a rather complicated engineering problem, and therefore, a systematic and well-established methodology is needed. This study proposes a multi-objective seismic design method for an inverted V-braced frame with suspended zipper struts that uses the non-dominated sorting genetic algorithm-II(NSGA-II). The structural weight and the maximum inter-story drift ratio as the objective functions are simultaneously minimized to optimize the cost and seismic performance of the structure. To investigate which of strength- and performance-based design criteria for braced frames is the critical design condition, the constraint conditions on the two design methods are simultaneously considered (i.e. the constraint conditions based on the strength and plastic deformation of members). The linear static analysis method and the nonlinear static analysis method are adopted to check the strength- and plastic deformation-based design constraints, respectively. The proposed optimal method are applied to three- and six-story steel frame examples, and the solutions improved for the considered objective functions were found.
본 연구에서는 철골모멘트골조의 보-힌지 붕괴모드를 유도하는 최적 내진설계기법을 제안한다. 이는 유전자알고리즘을 사용하며, 기둥의 소성힌지 발생을 억제하는 제약조건을 설정하여 보-힌지 붕괴모드를 유도한다. 제안하는 기법은 구조물량를 최소화하고 에너지소산능력을 최대화하는 목적함수를 사용한다. 제안하는 기법은 9층 철골모멘트골조 예제 적용을 통해 검증한다. 예제 적용을 통해 철골모멘트골조의 보-힌지 붕괴모드를 유도하기 위해 요구되는 기둥-보 강도비를 평가한다. 패널존에 대한 3가지 모델링 기법을 각각 적용하여 모델링 조건에 따른 휨강도비 영향이 추가적으로 검토된다.
This study is the compared seismic performance that are difference between the performance of structures on various site classes and beam-column connection. this analysis model was designed the previous earthquake load. To compare the performance levels of the structure was subjected to nonlinear static and nonlinear dynamic analysis. Nonlinear analysis was used to The Perform 3D program. Nonlinear static analysis was compared with the performance point and Nonlinear dynamic analysis was compared the drift ratio(%). Analysis results, the soft site class of the displacement was more increase than rock site classes of the displacement. Also The smaller the displacement was increased beam-column connection stiffness.
구조물의 붕괴성능을 정확하게 평가하기 위해서는 구조물과 관련된 구조부재 및 지반운동의 불확실성을 고려한 확률적 접근방식이 요구된다. 불확실성의 종류에 상관없이 불확실성은 구조물의 응답에 영향을 미치게 되는데, 구조물의 성능목표를 설정함에 있어 이러한 불확실성 전파를 예측할 필요가 있다. 최근 들어, 구조물의 붕괴성능을 평가하는 방법으로 사용되고 있는 증분동적해석은 지반운동과 관련된 임의적 불확실성을 해석과정에서 고려할 수 있다는 장점이 있으나, 확률론적 평가를 위한 또 다른 중요 요인인 인식론적 불확실성을 직접적으로 평가할 수 없다는 제한사항이 있다. 본 연구에서는 철골모멘트골조를 표본 건물로 선정하여 인식론적 불확실 요인으로 정의한 구조물의 고유감쇠, 지진중량, 구조부재의 항복강도 및 탄성계수가 구조물의 붕괴성능에 미치는 영향을 확률적으로 평가하였다. 이를 위하여 라틴 방격 추출법을 사용한 몬테카를로 시뮬레이션을 통해 증분동적해석을 수행하여 구조시스템 붕괴성능의 변동성을 정량적으로 예측하였다. 해석결과, 붕괴성능의 변동성에 인식론적 불확실성을 대표하는 변수 중에서 구조물 고유감쇠의 영향이 가장 두드러지는 것으로 나타났다.
철골보통중심가새골조의 수직불균형력에 대한 설계 요구사항이 KBC2009에서 처음으로 도입하였고, 이를 통하여 설계지진에서의 인명안전성능이라는 목표내진성능을 만족하도록 유도하고 있다. 그러나 수직 불균형력의 영향이 ASCE7-10에서 암시적으로 제시하는 최대고려지진에서의 구조물 붕괴방지성능에 미치는 영향에 대한 연구는 매우 제한적으로 이루어지고 있어 KBC2009를 따라 설계된 철골보통중심가새골조의 붕괴성능을 조사할 필요가 있다. 이를 위하여 본 논문에서는 역V형 철골보통중심가새골조의 최대고려지진에서의 붕괴양상을 조사하였다. 두 가지 지반조건과 세 가지 다른 수직불균형력 조건을 해석변수로 하여 총 6개의 5층 규모의 철골보통중심가새골조 표본건물을 설계하였다. 비선형 정적해석과 비선형 동적해석을 통하여 표본건물들의 내진성능과 붕괴양상을 조사하였다. 해석결과를 통해 수직 불균형력은 철골보통중심가새골조의 내진성능에 지대한 영향을 미쳤고, 바람직한 붕괴양상과 붕괴방지성능을 달성하기 위하여 불균형력에 대한 적절한 고려가 필요한 것으로 나타났다.
In this paper, Nonlinear Static Pushover analysis method(NSP) is proposed which apply to RC buildings reinforced by external retrofit fornseismic performance. Based on previous analysis and research, NSP is more developed by connection nonlinearity according to shearnresistance mechanism such as dowel and adhesive resistance as major shear resistance elements. According to the proposed method,nstructural analysis for example buildings was carried out to evaluate seismic performance of buildings. And, it was confirmed thatndepending on shear strain and characteristics of joint resistant of external retrofitting are different from internal retrofitting. Furthermore,nthe strength reduction coefficient of the anchor needs to be considered at the joint design.
구조물의 내용연수 동안 예상되는 지진에 대한 피해와 손실을 최소화하는 것이 내진설계의 최종적인 목표로 볼 수 있다. 이러한 목표를 만족시키기 위한 개념으로 지진하중에 대한 구조물의 손상확률을 나타내는 지진취약도를 작성하여 지진에 대한 구조물의 확률론적 성능평가를 수행한 후, 해당 지역에서 발생 가능한 지진에 대한 연간 초과확률로 표현되는 지진위험도를 활용하여 연간 손실 발생확률을 산정하는 절차를 제시한다. 본 연구는 미국 강진지역의 지진하중을 고려하여 설계된 철골모멘트골조에 대해 취약도를 정량적으로 평가하고 연간 손실 발생확률을 예측하다. 또한 HAZUS의 철골모멘트골조 대표건축물에 대한 손실 평가결과를 비교하였으며, 그 결과 HAZUS에 의한 연간손실이 보수적으로 산정됨을 알 수 있었다. 제시된 방법으로부터 해당 구조물의 내진성능 및 연간 손실 평가를 할 수 있으며, 향후 관련 연구에 활용할 수 있을 것으로 판단된다.
일반적으로 지진취약도를 평가할 때 사용되는 해석방법 중 하나인 역량스펙트럼 방법은 증분동적해석에 비해 해석의 정확성이 떨어지는 제한점이 있다. 본 연구에서는 증분동적해석이 가장 정확도가 높은 해석기법이라는 점에 착안하여 증분동적해석을 이용한 지진취약도 곡선의 도출과정을 제안하였다. 타당성 비교를 위하여 역량스펙트럼 방법과 제안된 방법으로 도출한 취약도 곡선을 비교하여 두 해석기법에 의한 지진취약도 곡선의 경향을 분석하였다. 그 결과 Slight damage와 Moderate damage의 경우 두 해석방법이 유사한 곡선 경향을 보이나 Extensive damage와 Complete damage의 경우에는 IDA방법에 의한 곡선이 더 가파른 경향을 보였다. 이는 구조물의 거동을 이상화하여 극한점 이후 구조물의 저항 강도가 떨어지지 않는다고 가정하는 역량스펙트럼 방법의 영향을 받는 것으로 사료된다.
본 연구의 목적은 다양한 높이에 따른 철골 중간모멘트골조의 내진성능을 평가하는 것이다. 구조물의 내진성능은 ATC-63에서 제안한 방법론에 따라 평가되었다. 3층, 6층, 9층, 12층 중간모멘트골조의 설계는 KBC 2009에 따라 수행하였다. 접합부의 모델링은 철골 중간모멘트골조에서 요구되는 회전성능인 0.02rad을 만족하도록 모델링하였다. 연구를 수행한 결과, 구조물의 붕괴확률은 높이가 증가함에 따라 증가하였다. 특히 9층과 12층 구조물은 ATC-63에서 제시한 요구조건을 만족하지 못하였다.
This paper is the sequel of a companion paper (I. Performance Evaluation) evaluating the relation between the seismic performance of steel intermediate moment frames (IMFs) and the rotation capacity of connections. The evaluation revealed that the seismic performance of IMFs having the required minimum rotation capacity suggested in the current standards did not meet the seismic performance criteria presented in FEMA 695. Therefore, thepresent study evaluates the causes of the vulnerable seismic performance for steel IMFs and proposes alternatives to satisfy the seismic performance suggested in FEMA 695. To that goal, the results of nonlinear analysis, which are the pushover analysis and the incremental dynamic analysis, are examined and evaluated. As a result, high-rise IMF systems are seen to have the lower collapse margin ratio after connection fracture than row-rise IMF systems and, the actual response isfound to compared tothedesign drift ratio acting on design load design. Finally, the minimum design load values are proposed to meet the seismic performance suggested in FEMA 695 for IMF systems having vulnerable seismic performance.
The current AISC341-10 standard specifiesa value of 0.02 radian for the minimum rotation capacity of connections for the intermediate steel moment frame system. However, despite of the advances realized in the domains of performance evaluation method and analysis method, research onthe minimum rotation capacity of the intermediate steel moment frame systemsatisfying the seismic performance has not been conducted in detail. In this study, the intermediate moment frame systemisdesigned with respect to current standards and the seismic performance in accordance with the rotational capacity of connections is evaluated using the seismic performance evaluation method presented in FEMA-P695. The minimum rotation capacity of intermediate steel moment frames required to satisfy seismic performance as well as the major design values affecting the seismic performance of moment frame areestimated. To that goal, the design parameters are selected and various target frames are designed. The analysis models of the main nonlinear elements are also developed for evaluating seismic performance. The resultsshow that the 20-story structure doesnot meet the seismic performance even if it satisfies the rotation capacity of 0.02 radian.