        1.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Spatial structure does not have columns and walls installed inside, so they have a large space. There are upper structure and substructure supporting them. The response of seismic loads to the upper structure may be increased or decreased due to the effects of the substructure. Therefore, in this study, the seismic response of the upper structure and the floor response spectrum of the substructure were compared and analyzed according to the height of the substructure in the spatial structure where the LRB was installed. As a result, the possibility of amplification of response was confirmed as seismic waves passed though the substructure, which is likely to increase the response of the upper structures.
        4,000원
        2.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently various composite beams in which concrete is filled in the U-shaped steel plate have been developed for saving story height and reducing construction period. Due to the high flexural stiffness and strength, they are widely being used for the building with large loads and long spans. The semi-slim AU composite beam has proven to take highly improved stability compared to the existing composite beams, because it consists of the closed steel section by attaching cap-type shear connectors to the upper side of U-shaped steel plate. In this study the finite element analyses were performed to evaluate the safety of the AU composite beam with unconsolidated concrete which were sustained through the closed steel section during the construction phase. The analyses were performed on the two types of cross section applied to the fabrication of AU composite beams, and the results were compared to the those of 2-point bending tests. In addition, the flexural performance according to the space of intermittent cap-type shear connectors and the location of reinforcing steel bars for compression was comparatively investigated. Through the results of analytical studies, it is preferable to adopt the yield moment of AU composite beam for evaluating the safety in the construction phase, and to limit the space of intermittent shear connectors to 400 mm or less for the construction load.
        4,000원
        3.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, composite beams have been developed in which concrete is filled in a U-shaped steel plate for saving height of story. And due to high flexural stiffness and bending strength, it is widely applied in the field where high load and long span are required. The AU composite beam was improved the instability of the existing beams because it makes a closed section by attaching a cover type shear connection to the existing U - shaped composite beam with open upper section. In this study, AU composite beam resisted by composite-section during the using phase was evaluated the safety through the finite element analysis. The analysis is performed on the five specimens of AU composite beams according to applied deck-system and compared with the results of 2 - point bending test. As a result of the analysis, behavior of beam was shown by integrated composite section. And the evaluation of flexible capacity was p
        4,000원
        4.
        2017.12 KCI 등재 서비스 종료(열람 제한)
        Recently, the parking in downtown area has caused severe problem due to the dramatic increase of possessing automobile in the country. A parking structure has been on the spotlight to solve the parking problem in downtown area. However, the overall height of parking structure is stipulated less than 8 m. Therefore, in this research, ‘wide composite beam’, which is possible for reducing story height and having long span, is developed and the flexural capacity of the wide composite beam is evaluated. Based on the result of the flexural test, the flexural strength of wide composite beam increased by 20% as the thickness of steel beam increased by 3 mm (6 mm → 9 mm) The shapes of rebar (whether it is triangle or rectangular shape) in the wide composite beam did not affect its flexural strength. The flexural strength of wide composite beam without rebar decreased by 10% compared to that of wide composite beam with rebar. In addition, the neutral axis moved upward as a load increased, but the neutral axis moved downward, when the load exceeded a certain level of load.