Tire noise is one of major causes of vehicle noise, and urban traffic noise pollution is becoming more and more serious as the number of vehicles continues to increase. Especially in the age of electric vehicles, improvement of tire noise is getting more important. Especially during highway driving, the noise from the tire became the main noise source of the vehicle. Tire noise is generated from the mutual friction between the tire and the road surface when driving. In this paper, we analyze various factors affecting tire noise generation, reduce environmental noise pollution, and increase ride comfort. The EU carried out the EC 1222/2009 tire labeling system in 2012, which was a severe blow to the tire exporting countries of all countries due to the stringent demand for tire noise. In this paper, 5 tires from 3 countries were selected and selected as test subjects. The purpose of this study is to analyze the noise of road / tire noise according to road condition of each tire.
목적: 본 연구는 안경원 및 안과의 시력 검사실의 다양한 조도가 피검자의 동공 크기 변화에 미치는 영향을 평가하고 자 하였다. 또한 이러한 동공 크기 변화가 이색검사를 이용한 굴절검사 결과에 미치는 영향을 분석하여 시력 검사실의 적정 조도 수준을 모색하고자 하였다. 방법 : 안질환 관련 수술 경험이 없고 시력과 동공에 영향을 줄 수 있는 전신질환 및 안질환이 없는 성인을 대상 으로 기본 검사(색각 검사, 동공 기능)를 진행하였다. 완전교정 자각식 굴절검사 후에 단안 이색검사를 진행하였다. 4단계의 조도(10, 50, 300, 630 lx)를 설정하고 각 조도에서 적응 후 동공 크기를 측정하였다. 굴절이상 변화는 적 록 차트를 사용하여 교정했으며, 변화가 있는 경우 0.12 D의 구면 렌즈를 추가하여 굴절이상 변화량을 정량화하였 다. 결과 : 각 조도 단계별 굴절이상 값(이색검사 값)의 변화량은 유의한 차이가 있었다(F=37.61, p=0.000*). 뿐만 아니라 동공 크기 증가에 따른 굴절이상 값의 변화량 사이에 유의한 양의 상관관계가 있었다(r=0.178, p=0.006**). 그리고 동공 크기가 증가할수록 굴절이상 값의 변화량도 유의하게 증가하는 것으로 나타났 다(p=0.006**). 특히 어두운 조도 환경(10 lx)에서 밝은 조도 환경으로 변환(630 lx) 시 굴절이상 값의 변화는 +0.24 D 이상으로 가장 두드러졌다. 결론 : 시력 검사실의 조도 변화는 피검자의 동공 크기 변화를 유발하며, 이는 굴절이상 값(이색검사 값)의 변화 에 영향을 미치는 주요 요인 중 하나임을 확인하였다. 따라서 실제 안경 착용자가 일상생활을 영위하는 환경의 조 도는 주로 명소시 상태에 해당하므로 안정적이고 최적의 시력 교정효과를 제공하기 위해서는 최소 50 lx 이상의 조 도 상태에서 최종 굴절이상 값의 결과를 확인하는 것이 적합할 것으로 사료된다.
전기추진 선박의 보급이 확대됨에 따라 추진축계의 정렬 불량, 비틀림 등 기계적 이상상태를 조기에 진단하기 위한 예지보전 (PHM) 기술의 필요성이 커지고 있다. 그러나 실제 운항 선박에서는 안전성과 운항 제약으로 인해 다양한 이상 상태를 의도적으로 재현하 기 어렵고, 이에 따른 학습·검증용 진동 데이터 확보에도 한계가 있다. 본 연구에서는 이러한 문제를 해결하기 위해 50kW급 전기추진 육 상 시험 시스템(Land‑Based Test System, LBTS)을 기반으로 전기추진 선박 추진축계의 비틀림 정렬 불량을 모사할 수 있는 실험 장치를 설계·구현하였다. LBTS는 SRPM(Synchronous Reluctance assisted Permanent Magnet)형 모터/발전기, AFE(Active Front End) 및 DC/DC 컨버터, 리 튬인산철 에너지저장장치(ESS)로 구성되며, PTO 모터를 슬라이딩 베이스에 장착하여 축 중심을 ±20mm 범위에서 조정할 수 있도록 제작 하였다(ESS 및 DC/DC 컨버터는 향후 추가적인 운전 조건 모사를 위해 탑재되었으며, 본 실험에서는 미사용). 이를 통해 정상 상태(0mm) 와 두 단계의 비틀림 상태(2mm, 4mm)를 설정한 후, 2,000rpm에서 3축 가속도계와 OROS사의 진동 분석기를 이용해 다채널 가속도 데이터 를 계측하고 FFT 분석을 수행하였다. 실험 결과, 비틀림이 증가할수록 진폭 및 주파수 성분의 변화 패턴이 관찰되었다. 본 연구에서 구축 한 0/2/4 mm 라벨링 진동 데이터셋과 LBTS 실험 환경은 향후 향후 1D/2D CNN 기반 PHM 알고리즘의 학습·검증에 활용될 수 있으며, 상태 분류 성능(Accuracy, Macro-F1)을 기준으로 오분류율 목표를 설정하여 정량 평가를 수행할 예정이다.
본 연구는 강풍에 취약한 설비로 선정된 154kV 직선형 송전철탑을 대상으로 극한 풍하중에 대한 구조 성능을 검토하였다. 선행연 구에 따르면 송전철탑은 정면풍보다 45° 풍향에서 더 취약한 거동을 보이며, 이를 고려하여 ABAQUS를 이용한 Pushover 해석을 수 행하였다. 극한 풍속 조건에서의 취약 부재와 거동 특성을 분석한 후, 길이 차원에서 1/2 상사율을 적용한 부분축소모형을 제작하였 으며, 지압이음 조건과 마찰이음 조건으로 구분하였다. 또한 두 대의 가력기를 이용해 전체모델에서 산정된 수평력과 휨모멘트를 상 사법칙에 따라 재현하였다. 실험 결과, 볼트 체결력을 향상시킨 경우 항복변위는 약 30% 감소했으나 항복하중에는 큰 차이가 없었다. 특히 마찰이음 조건에서는 해석과 실험의 항복하중 및 항복변위가 모두 5% 이내의 오차를 보여 Pushover 해석의 신뢰성이 검증되었다. 향후 연구에서는 주요 부재의 보강 방안을 수립하고, 보강된 부분축소모형 실험을 통해 내풍 및 내진 성능 향상을 검증할 예정이다.
하이드로겔은 친수성 고분자 네트워크로 높은 수분 함량과 생체적합성을 가지며, 조직 공학, 약물 전달 등 다양한 바이오 응용 분야에서 활용되고 있다. 그러나 하이드로겔의 친수성 표면은 약물 방출 속도를 지속적이고 정밀하게 제어하는 데 한계로 작용할 수 있다. 이러한 문제를 극복하기 위해, 약물의 방출 제어가 가능한 표면 개질 기술의 개발이 요구된다. 이 에 본 연구에서는, 표면 개질 기술의 모델 연구로써, poly(2-hydroxyethyl methacrylate) (PHEMA) 하이드로겔 표면의 알코올 기(-OH)를 octyltrichlorosilane (OTS)와 반응시켜 소수성 표면으로 개질하였다. 이러한 접근법은 하이드로겔의 기계적 특성과 같은 벌크 성질을 유지하면서도, 약물의 방출 속도 등에 영향을 주는 표면 특성을 제어할 수 있다. 나아가, 약물 전달뿐 아니 라 조직공학 지지체 및 바이오센서와 같은 생체 소재 개발을 위한 기반 기술로 확장 가능할 것으로 기대된다.
This study replicates and extends Lee-Ellis’s (2009) work by examining how different scoring methods affect the measurement characteristics of a Korean C-test. Thirty-six learners of Korean as a second language completed a five-passage C-test. Their responses were scored using Partial Credit Modeling, dichotomous item-by-item scoring, and dichotomous morpheme- by-morpheme scoring. Rasch analysis was conducted to compare reliability, person separation, item fit, and interpretability across these scoring approaches. The study also treated each text passage as a “super-item” to evaluate proficiency interpretation at the passage level. All three scoring methods demonstrated high reliability (above .97) and yielded highly correlated proficiency estimates. No single scoring method proved significantly superior in reliability, separation, or model fit. At the super-item level, the passages showed a narrow spread of difficulty indicating limited coverage of proficiency levels. These findings suggest that fine-grained scoring alone cannot compensate for limited test scope. To enhance the diagnostic value and level-referenced interpretation of C-tests, careful selection of text passages spanning a broader proficiency spectrum is essential.
With the increasing number of aging buildings, the importance of structural safety inspections has grown significantly. Traditional methods for inspecting welding defects, such as visual inspection and magnetic testing, rely heavily on human expertise, making them time-consuming, costly, and subjective. To address these limitations, thermographic technology has been introduced as a non-contact alternative, significantly reducing both time and cost. Furthermore, by incorporating AI, an objective and automated evaluation of welding defects can be achieved. In this study, we propose an AI-based thermographic approach for detecting welding defects. To validate the applicability of this method, a Mock-up Test was conducted. Specifically, 12 types of welding specimens with 4 welding part were prepared, generating a dataset of 6,500 thermographic images. Among 7 regression algorithms tested, RF and EXT were selected due to their superior performance. By ensemble learning these two models, we developed a robust welding defect measurement algorithm. To further verify its effectiveness, we applied the developed algorithm to 2 real projects, evaluating its applicability using 450 thermographic images. The results of this study demonstrate the feasibility of AI and thermographic technology in welding defect detection, highlighting its potential to enhance the efficiency and reliability of structural safety inspections in aging infrastructures.
국제해사기구(IMO)의 선박 환경규제 강화에 따라 선박 배출 온실가스 저감을 위한 대체연료 및 새로운 추진시스템의 도입이 활발히 진행되고 있다. 특히 연료전지와 배터리를 결합한 하이브리드 전기추진시스템은 배출가스 제로 및 높은 에너지 효율을 통해 차세 대 친환경 선박의 주요 대안으로 주목받고 있다. 본 연구에서는 이러한 전기추진시스템에 적용되는 암모니아 개질기의 선박 탑재를 위한 시험기준과 절차를 개발하고 그 타당성을 검증하였다. 암모니아는 저장 용이성, 운송 효율성 및 무탄소 배출 특성으로 인해 차세대 수소 공급원으로 주목받지만, 고온 개질기 필요, 독성 및 부식성, 잔류 암모니아 슬립 등 복합적 기술 문제와 안정성 확보 방안이 필수적이다. 이를 해결하기 위한 방안으로 본 논문은 실선 운항 조건을 반영한 4가지 핵심 시험항목(수소 생산량, 수소 순도, 잔류 암모니아 슬립, 경 사안정성)을 도출하고, 각 항목별로 시험환경, 절차, 측정기준, 수용기준을 포함한 정량적 시험방법론을 제시하였다. 해당 시험기준은 ISO 14687, IMO IGF Code 등 국제 기준을 기반으로 연계되며, 실선박에서의 신뢰성, 반복성, 실현가능성을 확보하기 위한 기반 자료로 활용 가 능하다.
인삼양영탕은 한국·중국·일본의 전통의약권에서 허약 개 선에 복용되는 14종 한약재로 구성된 의약품이다. 먼저 고 성능 액체 크로마토그래피(HPLC)를 적용하여 인삼양영탕 주요 물질을 규명하였다. 식품의약품안전처 단회투여독성 시험기준에 따라 Sprague-Dawley 랫드 암수 각 5마리에게 0, 1,000, 2,000, 5,000 mg/kg 용량으로 단회 경구 투여하 였다. 시험 결과 사망한 랫드는 없었으며 일반 증상 및 부 검소견에서도 어떠한 이상 반응도 관찰되지 않아, 랫드에 서 인삼양영탕 반수 치사량(LD50)은 5,000 mg/kg 이상으로 판단되었다. 문헌조사를 통해 조사된 인삼양영탕 일반독 성시험 5건(일본 2건, 중국 2건, 한국 1건)에 따르면 개략 치사량(ALD)은 160,000 mg/kg 초과, LD50는 10,000 mg/kg 초과, 최대내성용량(MTD)은 160,000 mg/kg 초과한다고 보 고하였다. 랫드 무독성량 5,000 mg/kg을 기준으로 인체 등 가 용량 변환하면 인삼양영탕 최대안전권장복용량(MRSD) 은 4.1 g 또는 4.8 g이며, 한의서 기준 인삼양영탕 성인 1 일 복용량 28.3 g을 랫드 독성시험 투여 용량으로 변환하 면 34,750 mg/kg 또는 29,100 mg/kg이다. 인삼양영탕 안전 성 평가를 위하여 동물과 인체 종간 등가 용량을 계산하 여 보니, 동물 독성시험 투여 용량과 실제 환자 복용 용 량 간에 유의미한 상관관계가 없음을 시사한다. 학계에서 는 전통적으로 확립된 한약처방 복용량에 대한 동물 독성 시험 평가시에 ICH 및 OECD 기준이외에 다각적인 투여 용량 검토가 필요하다고 사료된다.
원자력발전소에 설치되는 안전관련 기기는 높은 수준의 내진성능을 확보하여야 한다. 본 연구에서는 대표적인 안전관련 기기 인 전기 캐비닛을 대상으로, 열반(multi-bay) 구성 및 콘크리트 기초 열화와 같은 실제 설치 조건을 고려하여 내진성능을 평가하였다. 실제 현장에서는 전기 캐비닛이 열반 형태로 설치되는 경우가 많으며, 지지부 열화의 대표적 형태로 앵커 위치에서의 콘크리트 균열이 자주 발견된다. 이러한 조건을 반영하기 위하여, 앵커 위치에 균열 폭 0.5 mm 및 1.0 mm를 모사한 균열 기초와 건전한 기초를 대상 으로 실험체를 제작하였다. 실험체는 단순화한 전기 캐비닛 모델로서 단독(single-bay) 및 2기 열반(two-bay) 구성을 적용하였으며, 선설치 앵커로 고정 후 진동대를 이용한 한계상태 내진성능 실험을 수행하였다. 실험 결과, 균열이 없는 조건에서는 2기 열반 구성이 단독 구성보다 높은 내진성능을 보였다. 그러나 균열 조건에서는 2기 열반 구성에서 내진성능이 저하되는 경향이 나타난 반면, 단독 구성은 유의미한 성능 저하가 관찰되지 않았다.