High-rise buildings are equipped with TMD (Tuned Mass Damper), a vibration control device that ensure the stability and usability of the building. In this study, the seismic response control performance was evaluated by selecting the design variables of the TMD based on the installation location of the twisted irregular building. To this end, we selected analysis models of 60, 80, and 100 floors with a twist angle of 1 degree per floor, and performed time history analysis by applying historical seismic loads and resonant harmonic loads. The total mass ratio of TMDs was set to 1.0%, and the distributed installation locations of TMDs were selected through mode analysis. The analysis results showed that the top-floor displacement responses of all analysis models increased, but the maximum story drift ratio decreased. In order to secure the seismic response control performance by distributed installation of TMDs in twisted irregular buildings, it is judged that the mass ratio distribution of TMDs will act as a key variable.
Since atypical high-rise buildings are vulnerable to gravity loads and seismic loads, various structural systems must be applied to ensure the stability of the structure. In this study, the authors selected a 60-story twisted-shaped structure among atypical high-rise structures as an analytical model to investigate its structural behavior concerning the outrigger system. The structural analyses were performed varying the number of installed layers and the arrangement of the outrigger system, as well as the placement of the mega column, as design variables. The analysis revealed that the most effective position for the outrigger was 0.455H from the top layer, consistent with previous studies. Additionally, connecting outriggers and mega columns significantly reduced the displacement response of the model. From an economic standpoint, it is deemed efficient to connect and install outriggers and mega columns at the structure's ends.
국내 지진 발생의 빈도는 점차 증가하는 추세에 있으며, 포항지진(5.4 규모)은 진앙지와 주민 거주지가 가까워 피해 가 심각했는데 건물의 외장재가 떨어져 차량 등에 2차 피해가 발생하여 건물 외장재 안전에 대한 우려가 커지고 있는 실정이 다. 따라서 본 연구에서는 비구조 요소 중 커튼월의 동적 내진성능평가 규격에 대한 세계 각 국의 규준을 고찰하고 이 중에서 가장 널리 통용되는 AAMA501. 6-18에 따라 그 동적 내진성능을 평가하고자 한다. 또한, 본 연구에서 수행한 3축 동적 지진파 대응 가능 커튼월 시스템 실험을 통해 지진에 대한 2차 피해 방지를 위한 내진 커튼월 설계시공지침 개발에 기초적 자료로 제 공하고자 한다.
강진 시 원자력발전시설의 비선형 응답이 중요하기 때문에 이 시설의 내진성능에 대한 관심이 증가하였다. 이 연구에서는 원자력 발전소 철근콘크리트 전단벽의 유한요소해석을 위한 재료모델의 적절한 변수를 제시하였다: 최대인장강도, 팽창각, 손상계수. 이를 위해 상용 유한요소 해석프로그램인 ABAQUS를 사용하여 낮은 형상비를 가진 철근콘크리트 전단벽의 비선형 거동과 전단 파괴모드 에 대한 이 주요 변수의 효과에 대한 연구를 수행하였다. 연구결과에 기반하여 비선형 시간이력해석을 통해 강진 하의 원자로건물의 비선형 응답을 평가하였다.
A tilted tall building is actively constructed as landmark structures around world to date. Because lateral displacement responses of a tilted tall building occurs even by its self-weight, reduction of seismic responses is very important to ensure structural safety. In this study, a smart tuned mass damper (STMD) was applied to the example tilted tall building and its seismic response control performance was investigated. The STMD was composed of magnetorheological (MR) damper and it was installed on the top floor of the example building. Control performance of the STMD mainly depends on the control algorithn. Fuzzy logic controller (FLC) was selected as a control algorithm for the STMD. Because composing fuzzy rules and tuning membership functions of FLC are difficult task, evolutionary optimization algorithm (EOA) was used to develop the FLC. After numerical simulations, it has been seen that the STMD controlled by the EOA-optimized FLC can effectively reduce seismic responses fo the tilted tall building.
A shake table test is conducted for the three-story reinforced concrete building structure using 0.28 g, 0.5 g, 0.75 g, and 1.0 g of seismic input motions based on the Gyeongju earthquake. Computational efforts are made in parallel to explore the mechanical details in the structure. For engineering practice, the elastic modulus of concrete and rebar in the dynamic analysis is reduced to 38% and 50%, respectively, to calibrate the structure's natural frequencies. The engineering approach to the reduced modulus of elasticity is believed to be due to the inability to specify the flexibility of the actual boundary conditions. This aspect may lead to disadvantages of nonlinear dynamic analysis that can distort local stress and strain relationships. The initial elastic modulus can be applied directly without the so-called engineering adjustment with infinite element models with spring and spring-dashpot boundary conditions. This has the advantage of imposing the system flexibility of the structure on the sub-boundary conditions of springs and damping devices to control its sensitivity in a serial arrangement. This can reflect the flexibility of realistic boundary conditions and the effects of system damping (such as the gap between a concrete footing and shake table, loosening of steel anchors, etc.) in scalar quantities. However, these spring and dashpot coefficients can only be coordinated based on experimental results, making it challenging to select the coefficients in-prior to perform an experimental test.
The dynamic characterization of a three-story auxiliary building in a nuclear power plant (NPP) constructed with a monolithic reinforced concrete shear wall is investigated in this study. The shear wall is subjected to a joint-research, round-robin analysis organized by the Korea Atomic Energy Research Institute, South Korea, to predict seismic responses of that auxiliary building in NPP through a shake table test. Five different intensity measures of the base excitation are applied to the shaking table test to get the acceleration responses from the different building locations for one horizontal direction (front-back). Simultaneously to understand the global damage scenario of the structure, a frequency search test is conducted after each excitation. The primary motivation of this study is to develop a nonlinear numerical model considering the multi-layered shell element and compare it with the test result to validate through the modal parameter identification and floor responses. In addition, the acceleration amplification factor is evaluated to judge the dynamic behavior of the shear wall with the existing standard, thus providing theoretical support for engineering practice.
여러 센서를 이용한 구조물의 구조 응답을 모니터링하는 사례가 증가하고 있다. 그러나 비용과 관리 문제로 인해 제한된 센서만이 구조물에 설치되어 일부의 구조 응답만을 수집하는 경우가 대부분이다. 이는 구조물의 전체 거동을 분석하는데 장애요소로 작용하게 된다. 따라서 제한된 센서를 이용해 센서가 설치되지 않은 위치에서의 응답을 신뢰할 수 있는 수준으로 예측하는 기술이 필요하다. 본 연구에서는 제한된 정보를 이용해 저층 건물 구조물의 지진 응답을 예측하는 해석적 연구를 수행한다. 활용 가능한 응답 정보는 1층과 최상층의 가속도 응답만을 사용할 수 있다고 가정한다. 두 정보를 이용하면 구조물의 1차 고유진동수를 얻을 수 있다. 1층 가속도 정보는 구조물의 가력 정보로 활용한다. 최상층의 가속도이력응답에 대한 오차와 대상 구조물의 1차 고유진동수 오차를 최소화하는 구조물의 질량과 강성 정보를 유전자알고리즘을 이용해 예측하는 기법을 제시한다. 제약조건은 고려하지 않는다. 탐색공간을 의미하는 설계변수의 범위를 결정하기 위해 인공신경망 기반의 파라미터 예측기법을 제시한다. 또한 유전자알고리즘을 통해 얻게 되는 해를 개선시키기 위해 앞서 언급한 인공신경망을 활용한다. 제시한 기법을 검증하기 위해 5층 구조물 예제를 사용한다.
트윈 빌딩의 풍하중의 특성과 구조적 특성은 일반 고층건물보다 복잡하다. 이러한 특성을 조사하기 위해서 풍동실험을 통해서 트윈 빌딩의 풍압을 계측하였다. 계측된 데이터와 적합 직교 분해 기법을 이용하여 풍압의 패턴을 파악하였다. 1차 모드에서는 채널링 효과가 2차 모드에서는 와류 효과가 나타났다. 또한, 두 빌딩의 하중의 상관관계를 파악하였는데, 풍 방향 하중은 양의 상관관계를 가지며, 풍 직각 방향의 하중은 명확한 상관관계가 나타나지 않았다. 이러한 상관관계는 횡 방향 변위에도 영향을 미쳤다. 양의 상관관계를 가지면 트윈 빌딩을 연결하는 구조부재의 영향이 적게 작용한 반면에 음의 상관관계를 가지면 연결 구조부재의 영향이 횡 방향의 변위를 줄이는데 큰 영향을 미치게 되었다.
Seismic isolation systems have typically been used in the form of base seams in mid-rise and low-rise buildings. In the case of high-rise buildings, it is difficult to apply the base isolation. In this study, the seismic response was analyzed by changing the installation position of the seismic isolation device in 3D high - rise model. To do this, we used 30-story and 40-story 3D buildings as example structures. Historic earthquakes such as Mexico (1985), Northridge (1994) and Rome Frieta (1989) were applied as earthquake loads. The installation position of the isolation device was changed from floor to floor to floor. The maximum deformation of the seismic isolation system was analyzed and the maximum interlaminar strain and maximum absolute acceleration were analyzed by comparing the LB model with seismic isolation device and the Fixed model, which is the base model without seismic isolation device. If an isolation device is installed on the lower layer, it is most effective in response reduction, but since the structure may become unstable, it is effective to apply it to an effective high-level part. Therefore, engineers must consider both structural efficiency and safety when designing a mid-level isolation system for high-rise buildings.
본 논문에서는 반응표면법과 다목적최적화 기법을 이용한 유한요소모델개선기법의 절차를 제안하고 이를 저층의 철근콘 크리트건물의 모델개선에 적용하였다. 대상건물은 전단벽 신설 및 댐퍼부착을 위한 부재의 강재보강을 통해 내진보강이 이 루어진 건물로서 보강전후에 소형 가진기를 이용한 진동실험을 실시하여 동특성을 구하였다. 대상건물의 개선에 사용된 변 수는 기존콘크리트, 신규타설된 콘크리트, 조적의 탄성계수, 신축줄눈부의 스프링계수, 강재보강된 부재의 유효강성비이다. 보강전후 건물의 초기모델을 구축한 후 중심합성법에 따라 개선변수의 값을 변화시키면서 얻은 해석결과를 통해 고유진동 수의 오차와 모드형상의 오차를 나타내는 2개의 반응함수를 구하고, 이를 다목적최적화의 목적함수로 사용하였다
In this study, Stockbridge damper was adopted to reduce the reponses of structures under earthquakes. A finite element analysis software, SAP2000, was used to simulate the structural response and the control device under dynamic loads. A 3 story frame model and the proposed control device, Stockbridge damper, were designed under laboratory conditions. In this research, a pendulum type tuned mass damper (PTMD) was also adopted in order to compare with the Stockbridge damper. Harmonic loads were applied to verity the control performance of both control devices in each mode. In results, it has been found that the Stockbirdge damper decreases significantly the responses of the structure more than the PTMD under the harmonic loadings. The El Centro and Northridge earthquakes were also applied in order to investigate the performance by both control devices. The responses of the building demonstrate that the Stockbridge damper reduces the response of the building structure during earthquakes more effectively than the PTMD.
Developments on the Chinese automotive market could change the business in the race to the crown for German premium brands. With extraordinary growth rates, car manu-facturers prioritized Asian market development. More concrete, a quickly evolving segment of young, wealthy Chinese customers demanding German luxury cars seems to be a chance to compensate maturing home markets. BMW – originated in premium segments – is about to expand its luxury reach through its 7-series while, at the same time, serving the increasing demand for “affordable luxury” in all markets. However, competitors are catching up with new concepts. Whereas Mercedes-Benz always had a great proportion in the luxury segment, Audi became the market leader in China by launching several new luxury models. BMW sees the answer in the possible launch of a new 9-series sharing a platform with their Rolls-Royce cars. Furthermore, the BMW Individual manufactory launched a new, strictly limited 7-Series in corporation with silver manufacturer Robbe & Berking – the most expensive and exclusive car BMW ever crafted. To be able to win the race, BMW has to incorporate new technologies when considering the trading-up or trading-down of their model range.
허베이 스피리트호의 유류유출량이 씨프린스호의 것에 비해 2.5배에 불과하지만, 그 경제적·환경적·사회적 피해는 30배에 이를 정도로 대규모 유류유출의 피해는 기하급수적으로 증가할 수 있다. 본 연구에서는 이와 같은 재난적 해양환경오염사고에 신속하고도 효율적으로 대응할 수 있는 다목적 대형방제선의 건조에 대한 기술적·경제적 타당성을 분석함으로써 다목적 대형방제선의 건조에 대한 당위성과 정당성을 확보하고자 한다. 다목적 대형방제선의 기술적 타당성분석과 선진해양국의 많은 사례를 검토한 결과, 4,000톤급의 자항식 호퍼준설선 겸용 방제선을 건조하는 것이 적합한 것으로 판단되었다. 경제적 타당성 분석결과, 가장 보수적인 추정의 B/C ratio는 0.82로 경제성에 미달하지만 자구적 노력을 통하여 경제성을 확보할 수 있다. 한편, 중간추정치와 낙관적 추정치의 B/C ratio는 각각 2.72와 5.82로 이 사업의 경제적 타당성을 충분히 확보할 수 있다.
Over the past decade the maritime accident analysis casualties is 10 000 surpassed the persons marine accidents Due to the nature of government response alone is effective neither economic nor nor rich, well versed in local waters assess and advanced form through this site access to rapid private sector resource utilization civil and tube cooperation system building is the most effective and feasible Golden Time successful advanced marine structures within the system structure is possible
본 논문에서는 FSI해석을 이용하여 비정형 초고층 빌딩의 풍응답 특성을 연구하였다. 해석모델은 Twist모델이며, 뒤틀림 각도와 풍가속도의 상관관계에 대해 연구 중점을 두었다. 먼저 단방향 해석을 수행하여 100년 재현주기 풍속에 대한 최대 횡 변위를 구하고, 제한조건을 만족하는 탄성계수를 산출한다. 그리고 양방향 해석을 수행, 시간이력해석을 통해 산출된 탄성계수와 임의의 밀도를 가지는 풍가속도를 예측하게 된다. 정방형 모델은 높이 400m, 변장비 1:1, 세장비 8로 설정, 뒤틀림 모델은 0도에서 90도까지 15도 간격으로, 90도에서 360도까지 90도 간격으로 비틀어 회전시켰다. 형상에 따른 풍가속도 예측결과, 정방형 모델이 뒤틀림 모델보다 크게 산출되어 풍진동 영향에 더 민감한 것을 검증하였다.
고층 건축물의 내풍설계 시 다차모드 해석의 수행이 필요하다. 고층건축물의 다차모드 해석을 위해서 풍압적분법과 1차모드 해석을 수행하였으며, 풍압적분법을 활용하여 층별 시간이력 전도모멘트를 산출하였다. 층별 전도모멘트를 산출하기 위해 풍압적분법을 활용하였고, 그 방법으로 임의의 층까지의 누적 풍력데이터로부터 층별 시간이력의 전도모멘트를 산출하였다. 풍응답변위는 각 층별 전도모멘트로부터 1차 모드 해석을 수행하여 평가하였다. 본 연구 결과의 그 유효성을 높이기 위해, 건축물 전체에 작용하는 풍력데이터에 의해 얻어진 풍응답 결과와 비교하였다. 두 연구 결과는 유사한 것으로 나타났다.
Spatial variations of a seismic wave are mainly wave passage and wave scattering. Wave passage effect is produced by changed characteristics of exciting seismic input motions applied to the bedrock. Modified input motions travel horizontally with time differences determined by apparent shear wave velocity of the bedrock. In this study, wave passage effect on the seismic response of a structure-soil system is investigated by modifying the finite element software of P3DASS (Pseudo 3-Dimensional Dynamic Analysis of a Structure-soil System) to apply inconsistent (time-delayed) seismic input motions along the soft soil–bedrock interface. Study results show that foundation size affected on the seismic response of a structure excited with inconsistent input motions in the lower period range below 0.5 seconds, and seismic responses of a structure were decreased considerably in the lower period range around 0.05 seconds due to the wave passage. Also, shear wave velocity of the bedrock affected on the seismic response of a structure in the lower period range below 0.3 seconds, with significant reduction of the seismic response for smaller shear wave velocity of the bedrock reaching approximately 20% for an apparent shear wave velocity of 1000m/s at a period of 0.05 seconds. Finally, it is concluded that wave passage effect reduces the seismic response of a structure in the lower period range when the bedrock under a soft soil is soft or the bedrock is located very deeply, and wave passage is beneficial for the seismic design of a short period structure like a nuclear container building or a stiff low-rise building.