검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 299

        101.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, as demand for Electric Car has been increasing, it has been a main factor that maximizing performance and ensuring the stability of the Electric Car battery to increase the reliability of Electric Car. Above all the study on thermal control in a big influence on the performance and battery life is growing in parallel. This study has compared cooling effect of an Electric Car battery between battery with Heat Sink and without Heat Sink for optimum design of Electric Car battery. Battery is simply modeled into four cells, divided into two cases of battery with Heat Sink that attached on the cell's side and without Heat Sink. And this research was conducted on forced convection. The battery which is designed by this way was numerically analyzed by CFX 14.5. Numerical results, revealed that the battery with Heat Sink was superior in terms of cooling effect. According to the numerical analysis by battery cell's temperature variations, the battery with Heat Sink turned out to be superior in cooling effect to the battery without Heat Sink.
        4,000원
        102.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        온실의 냉난방시스템 설계 기준에 적용하기 위한 외부 기상조건을 설정하기 위하여 난방 설계용 외기온, 난방 degree-hour, 냉방 설계용 건구온도, 습구온도, 일사량을 분석하여 제시하였다. 우리나라 전 지역을 대상으로 현재 기상청에서 제공하는 기후평년값 기준인 1981~2010 년까지 30년간의 매 시각 기상자료를 분석에 사용하였다. 표준기상데이터의 이용이 제한적이기 때문에 30년간의 전체 기상자료를 이용하여 설계용 기상조건을 구하고, 전체 자료기간의 평균값을 설계기준으로 제시하였다. TAC 방식으로 위험률 1, 2.5, 5%에 대한 설계용 기상자료를 분석하고, 설계기준에서 추천하고 있는 난방용은 위험률 1%, 냉방용은 위험률 2.5%의 기상조건 분포도를 제시하였다. 지역별, 위험률별 및 설정온도별로 최대난방부하, 기간난방부하 및 최대냉방부하의 변화를 고찰하였다. 제시된 각종 설계용 기상조건은 온실의 냉난방시스템 설계에 직접 이용할 수 있을 뿐만 아니라 냉난방 설비 보강이나 에너지 절감대책의 수립에 활용이 가능할 것으로 판단된다. 한편 기후변화로 인하여 최근 여름철 폭염이나 겨울철 이상고온 현상이 자주 발생하고 있으므로 주기적인 설계용 기상자료의 분석이 필요하고, 최소한 10 년 주기로 설계기준을 개정할 필요가 있는 것으로 생각 된다. 본 연구에서는 현재 기후평년값 기준인 1981 ~2010년까지의 기상자료를 분석하였으나 이 기준이 1991~2020년으로 바뀌는 2021년에는 즉시 이 기간의 기상자료를 분석하여 새로운 설계기준으로 제공해야 할 것으로 판단된다.
        4,300원
        103.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        An experiment was carried out to determine the effect of cooling water treatment with ionized calcium on calcium content, extending the shelf-life and quality of fresh chicken meat in poultry slaughtering process. The subjects were divided into four groups: control (0% without ionized calcium) and treatment groups (0.5, 0.7, 0.9% ionized calcium). The results indicated that the cooling water treatment with ionized calcium exhibited the bacterial counts of 105 CFU/cm2 in surface of chicken meat, and maintained the quality of fresh chicken meat with extending the shelf-life above seven days when compared with that of control group. The results found that the cooling water treatment with ionized calcium could produce the calcium enrichment of chicken meat as nine times higher in calcium content of chicken meat when compared with that of control group. pH, water holding capacity, TBARS (MDA mg/kg) in chicken meat via the cooling water treatment with ionized calcium showed 6.4, above 50, below 0.10, respectively, with preventing the oxidation of unsaturated fatty acids. Lightness (L*) as a chicken meat color, shear force indicated above 60, below 1.70 kg/0.5 inch2, respectively.
        4,300원
        104.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Determining of the shape in the process of design for natural draught cooling tower is very important, because the shape of hyperbolic shell is respond sensitively to dynamic behavior of the whole cooling tower against wind load. In engineering practice, the geometric parameters have been determining based on the natural frequency. This study analyses influence of the tower shell geometric parameters on the structural behavior. For three representative models were selected, they were analyzed based on evaluation of damage by means of nonlinear FE-method. As a result, a hyperbolic rotational shell with the small radius overall was the lowest damage index induced by sufficient capacity of the stress redistribution and thus a wind-insensitive structure.
        4,300원
        105.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A new design concept for integrated thermal energy storage system is suggested to increase energy saving rate for heating and cooling system of the closed glass greenhouse. Heat pump of air source is installed in the mechanical room and air flows then controlled by damper system located between the greenhouse and outdoor environments. A damper control algorithm is designed to enhance the usage of excessive energy in the glass greenhouse. Since the proposed system is installed at the actual glass greenhouse site for experimental verification of energy savings, the proposed system with damper control is compared with conventional greenhouse heating and cooling system. From results, it is found that more than 10% increase of energy saving rate is achieved.
        4,000원
        106.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, solid solution heat treatment of consolidated nickel-based superalloy powders is carried out by hot isotactic pressing. The effects of the cooling rate of salt quenching, and air cooling on the microstructures and the mechanical properties of the specimens are analyzed . The specimen that is air cooled shows the formation of serrated grain boundaries due to their obstruction by the carbide particles. Moreover, the specimen that is salt quenched shows higher strength than the one that is air cooled due to the presence of fine and close-packed tertiary gamma prime phase. The tensile elongation at high temperatures improves due to the presence of grain boundary serrations in the specimen that is air cooled. On the contrary, the specimen that is salt quenched and consists of unserrated grain boundaries shows better creep properties than the air cooled specimen with the serrated grain boundaries, due to the negative creep phenomenon.
        4,000원
        107.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 BES 기법을 활용하여 온실을 대상으로 실시간 에너지교환 시뮬레이션 모델 개발 및 검증을 수행하고 냉·난방부하 산정 및 경향성을 분석하였다. 우선 BES 기법과 현장실험을 기반으로 온실의 실시간 에너지 교환 모델을 개발하였다. 광흡수율, 엽면적지수, 잎 특성 길이 등 대상작물인 애플망고의 특성 값들과 온실 내부 이산화탄소 농도, 광량, 온도 등 실시간 입력 자료를 고려하여 작물 및 토양의 에너지교환을 구현하였다. 모델의 검증은 온실 내부 기온으로 수행하였으며 실측 내부 기온과 연산된 내부 기온 간의 결정계수, 일치도로 평가 하였다. 내부 기온 비교는 결정계수 0.89, 일치도 0.93으로 높은 유사성을 확인하였으며 모델의 유의성을 판단하였다. 개발한 모델과 2005년부터 2014년까지의 기상자료, 대상작물의 생육단계별 적정생육온도를 이용하여 대상온실의 냉·난방부하 산정하였다. 연도별 냉·난방부하산정 및 경향성을 파악하였으며 최대 냉·난방부하 산정을 통하여 대상온실의 냉·난방장치 용량설계의 기초자료를 확보하였다. 최근 10년 치 기상자료를 통하여 평균 최대 난방부하 525,473 kJ·hr-1, 평균 최대냉방부하 630,870 kJ·hr-1가 산정되었으며 대상 온실에 지열, 온배수, 태양열 등 신재생에너지를 활용할 경우 유용하게 활용될 것으로 판단된다. 본 연구를 통하여 온실 내 각 구성요소 간의 실시간 에너지교환을 모의할 수 있었으며 추후 온배수 활용을 위한 저류조, 히트펌프, 축열조 등의 설비를 구현함에 따라 전반적인 냉·난방 시스템의 구현 가능성을 확인하였다. 또한 동적 해석방법을 통하여 재배작물, 생육단계 및 토양을 고려하였으며 온실 에너지교환 모델에 다양한 형태로 적용 가능할 것으로 판단된다.
        4,000원
        108.
        2016.05 구독 인증기관 무료, 개인회원 유료
        Cooling towers have been widely applied to control the indoor temperature in the residential area and the living space. At operating the cooling towers, motor, fan and dropping water produce noise and vibration, which diffuse through the air or the solid object, polluting the environment. The standards can be used at estimating noise and vibration emission by showing remarkable economic or social benefits. The purpose of this study is to show the vibration and noise measurement and influence evaluation between cooling towers and semiconductor equipment.
        4,000원
        109.
        2016.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Shelter that communication equipment and on-equipment material are mounted on is transported by airplane, vehicle and has a function such as waterproof and shielding EMI. Maintaining proper inside temperature of shelter is important in order to operate equipment. Accordingly proper cooling capacity of cooling equipment which installed on the shelter is important for equipment and operator. To calculate proper cooling capacity, There are some considerations such as environmental factors and equipment in the shelter. In Korea solar irradiation and outdoor temperature is difference in accordance with geological characteristic. Also electric equipment mounted on the shelter is increased by development of technology. But the capacity of air conditioner is not changed thus there is a problem about operating equipment. In this paper, Compare cooling capacity of shelter when using air conditioner that is not enough cooling capacity and calculate proper cooling capacity to consider geological solar irradiation and outdoor temperature.
        4,000원
        110.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was developed the rapid heating and cooling device using peltier module for uniform cooling. make the rapid heating and cooling device(RCHD), for traditional water cooling device(TWCD) method and the rapid heating and cooling method warpage were compared and were analyzed and the materials used crystalline PP polymer. various warpage were compared for the process parameters such as packing pressure, packing time, mold temperature. in the crystalline PP polymer, TWCD method has higher warpage than RCHD method and show the result to be a bit more uniform cooling. RCHD method has higher warpage than TWCD method as cooling time and packing time increases and TWCD method has higher warpage than RCHD method as mold temperature increases.
        4,000원
        111.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        여름철에 파프리카 코이어 배지경에서 ‘Cupra’, ‘Piesta’ 2품종을 공시하여 시설 내 포그냉방 효과에 의한 파프리카 생육을 검토코자 하였다. 시설 내 포그 냉방처리를 통해 무처리보다 온실 내의 온도가 2~3oC 낮았으며 최고온 도를 35oC이하로, 그리고 실내습도도 80% 내외로 유지할 수가 있었다. 초장, 엽수 등 생육은 포그냉방 처리구가 무처리에 비해 양호하였다. 평균과중은 두 품종 모두 포그 냉방 처리구에서 158~160g으로 무처리보다 무거웠고, 주 당 착과수는 ‘Cupra’, ‘Piesta’ 모두 포그냉방 처리구가 각 각 18.4, 18.3개로 무처리에 비해 7~8개 많았다. 상품수량은 ‘Cupra’, ‘Piesta’ 두 품종 모두 포그냉방 처리구가 각 각 6,027, 5,890kg/10a으로 무처리에 비해 유의적으로 많았다. 과실의 당도는 처리간에 차이가 없었으며 ‘Cupra’, ‘Piesta’ 두 품종 모두 5~6oBx 였으며 과육의 두께는 포그 냉방 처리 효과가 없었다. 과실의 열과 발생률은 포그냉방 처리구가 낮았으며 품종 간에는 차이가 없었다. 이상의 결과에서 여름철 파프리카 수경재배시 포그냉방으로 시설내 온도의 강하와 습도조절이 가능하였으며 그에 따른 결과, 생육이 양호하며 과실의 품질 또한 좋 아짐을 알 수 있었다.
        4,000원
        112.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        근권부 공기순환 덕트 냉방이 온도 및 생육에 미치는 영향을 구명하고자 고온기 파프리카((Capsicumannum.L. ‘Veyron’)을 코이어배지에서 수경재배하였다. 냉방시간 처리는 24시간 연속 가동한 연속냉방(All-day), 17시부터 다음날 1시까지 8시간 냉방한 야간냉방(Night), 대조구인 냉방 무처리(Control) 등 3 처리하여 온실 상·하부 온도, 근권온도, 엽온, 과실 특성 및 기관 분배율을 측정하였 다. 근권부 덕트 냉방하였을 때, 고온기(6월 ~8월) 온실 하부(바닥으로부터 40cm)와 상부(바닥으로부터 180cm) 온도, 근권온도는 하강되었다. 대조구와 비교하여 온실 하부/상부 온도 차이가 연속냉방에서는 4.4~5.1oC/ 2.1~3.1oC 하강을, 야간냉방 처리에서는 3.4~3.8oC/ 2.2~2.7oC 하강되었다. 근권온도는 온실 하부 온도 결과와 유사했으며, 연속냉방(22.8oC)> 야간 냉방(24.1oC) > 대조구(27.7oC) 순으로 온도가 낮았다. 연속냉방 처리에서 덕트 위치(통로, 베드하단)와 송풍 방향(45o, 90o, 180o)에 따른 온도 변화를 측정한 결과 덕트의 위치가 통로에 위치하고 송풍방향이 상향(45o) 또는 수평(180o) 인 처리는 지상부 100cm까지의 수직 위치에 따른 온도 차이가 크지 않지 않으면서, 근권부위 온도인 지상 50cm 온도가 낮은 특징을 보였고 베드와 베드 공간 사이로 덕트 송풍 방향이 직각(90o)이였을 때는 바닥과 지 상 50cm 부위의 온도가 높고, 지상 100cm 이상 200cm 부위 온도가 상대적으로 낮았다. 연속냉방 또는 야간냉방 처리했을 때 파프리카 엽온은 오후 7시가 오전 9시 보다 엽온 하강이 컸다. 과실 분배율은 대조구(24.4%)에 비해 연속냉방(48.6%)과 야간냉방(45.6%)에서 높았으며, 평균과중, 과수 및 수량도 연속냉방 처리에서 가장 높았다. 한편 야간냉방 처리에서도 고온기 평균 지상부 및 근권온도를 낮추었으나, 누적된 평균온도가 가장 낮은 연속냉방처리에서 과실로의 동화산물 분배율을 높여 파프리카 수량을 증가시킨 것으로 보인다.
        4,000원
        113.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        온실의 냉방부하 산정방법 개발을 위하여 열수지 방법에 기초한 냉방부하 산정식을 구성하고, 포그냉방 온실 에서 냉방부하를 실측하여 검증하였다. 포그냉방 온실의 냉각열량은 포그분사에 의한 증발수량에 물의 증발잠열을 곱하여 구할 수 있다. 여기서, 증발수량은 포그 분사량에 증발효율을 곱하면 구할 수 있으며, 즉 분무수량을 계측하고 포그시스템의 증발효율을 알면 온실의 냉방부하를 실측할 수 있다. 따라서 온실의 냉방부하 실측을 위하여 실험온실에서 포그시스템의 증발효율을 실험하고, 실험온실의 열환경 계측과 더불어 포그 분사량을 계측하여 냉방부하 산정방법을 검토하였다. 먼저 냉방부하 산정식의 환기전열량을 검토하기 위하여 냉방을 실시하지 않은 상태에서 환기량 실측 실험을 통해 비교한 결과 열수지식을 이용한 환기전열량 예측은 비교적 양호한 결과를 보이는 것으로 나타났다. 이류체 포그시스템의 증 발효율은 0.3~0.94의 범위를 보였으며 평균 0.67로 나타 났고, 환기율이 증가함에 따라 커지는 것으로 나타났다. 포그냉방을 실시하면서 온실의 환경을 계측하여 열수지 식으로 냉방부하를 계산하고, 분무량 실측치로부터 증발 냉각열량을 구하여 비교한 결과 냉방부하 계산치와 실측치는 대체로 유사한 경향을 보이는 것으로 나타났다. 냉방부하가 낮은 경우에는 실측치에 비하여 약간 크게 예측되었고, 냉방부하가 높은 경우에는 실측치보다 작게 예측되었다. 온실의 냉방시스템 설계 시에는 최대냉방부하를 이용하여 냉방설비의 용량을 결정하게 된다. 따라서 냉방부하가 큰 쪽에서 실측치보다 작게 예측되는 부분은 검토가 필요하지만 설비용량 산정시의 안전계수를 고려하면 본 연구에서 제시한 냉방부하 산정방법은 온실의 환경설계에 적용할 수 있는 것으로 판단된다.
        4,000원
        114.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Air-shiter is a new products possible ventilation at the same time cooling or heating with integrated refrigeration and ventilation units. and is a key component of the air shifter devices and bypass damper. The air shifter devices are to convert the outdoor air, room air, supply air and exhaust air flow. And the bypass damper is device to determine a ventilation. After research and development of these systems were as follows. It is confirmed that the Air-shiter is possible ventilation at the same time cooling or heating, and outdoor air cooling in the spring or fall.
        4,000원
        115.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Cooling towers have been widely applied to control the indoor temperature in the residential area and the living space. At operating the cooling towers, motor, fan and dropping water produce noise and vibration, which diffuse through the air or the solid object, polluting the environment. The standards can be used at estimating noise and vibration emission by showing remarkable economic or social benefits. The purpose of this study is to show the characteristics, measurement methods for the evaluation of noise and vibration in cooling tower.
        4,000원
        116.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        GRP pipe (Glass-fiber Reinforced Plastic Pipe) lines making use of FRP (Fiber Reinforced Plastic) are generally thinner, lighter, and stronger than the existing concrete or steel pipe lines, and it is excellent in stiffness/strength per unit weight. In this study, we present the result of field test for buried GRP pipes with large diameter(2,400mm). The vertical and horizontal ring deflections are measured for 387 days. The short-term deflection measured by the field test is compared with the result predicted by the Iowa formula. In addition, the long-term ring deflection is predicted by using the procedure suggested in ASTM D 5365(ANNEX) in the range of 40 to 60 years of service life of the pipe based on the experimental results. From the study, it was found that the long-term vertical and horizontal ring deflection up to 60 years is less than the 5% ring deflection limitation.
        4,000원
        117.
        2015.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 논문은 화재에 노출된 철근콘크리트 구조에 대한 수치해석 모델을 제시하고, 기존의 자료 및 설계 규준과의 비교를 통해 구조물의 설계 시 고려 사항에 대해 제안하고 있다. 수치해석은 비정상 열전달 해석과 비선형 구조해석의 두 단계로 수행되며, 비정상 열전달 해석을 통해서 얻어진 화재시간에 따른 단면 온도분포를 바탕으로 비선형 구조해석하여 부재의 상태에 대한 정보를 얻게 된다. 이때, 철근콘크리트의 재료모델을 화재진행상태(Under-Fire)와 화재종료 후 냉각상태(After-Cooling)로 나뉘어 해석수행하여 각각의 재료상태에 따른 거동의 변화를 살펴본다. 해석된 결과는 여러 구조물에 대해 기존의 실험결과와 비교하여 검증하고, 설계 규준과의 비교를 통해 화재 시 구조물의 안전성에 대해 고찰하였다.
        4,500원
        118.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 냉각코일과 리튬브로마이드 수용액을 활용 하여 유리 chamber 내 냉각 및 제습 실험을 수행하였다. 냉각수 온도별 냉각 효과와 리튬브로마이드 수용액의 제습량을 확인하였으며, 이를 동시에 적용하여 실험을 수행하였다. 냉각수 온도별 냉각 실험은 279K, 286K, 293K에서 각각 19K, 13K, 10K 가량 감소되는 경향을 보였다. 냉각수 온도가 낮을수록 높은 냉각 성능을 보였으며, 여름철 상하수도 온도인 293K의 물로도 충분히 작물이 생육하기 좋은 온실 내부온도를 유지할 수 있다고 판단되었다. 또한 리튬브로마이드 수용액을 활용한 제습 실험에서는 약 80%의 외부 습도가 리튬브로마이드 수용액과 결합하여 약 50%로 감소되어 약 30%의 제습량을 보였으며, 이는 시설 내 제습 시스템의 적용에 적합한 물질로 판단된다. 냉각코일과 리튬브로마이드 수용액을 동시에 적용한 실험에서 약 9K의 온도 강하, 15%의 제습량을 나타냈으며, 리튬브로마이드 수용액이 수증기를 흡수하는 과정에서 반응열이 발생하는 것을 확인하였다. 또한, 시뮬레이션을 통해 냉각 실험 결과와 대비 비교 한 결과 약 299.7K의 내부 온도를 보여 일치하는 것을 확인하였다. 수분의 제습과정을 거치면서 농도가 낮아진 리튬브로 마이드 수용액(희용액)은 수집탱크로 모아 재생부로 이송되어 가열, 수분을 증발시켜 농용액으로 전환된 후 열 교환을 거쳐 냉각되어 다시 제습시스템으로 공급되는 시스템을 적용하면 일정량의 리튬브로마이드 수용액만으로 온실 제습을 할 수 있을 것으로 판단된다. 본 실험을 통해 냉각 및 제습이 동시에 가능하다는 것을 확인하였으며, 리튬브로마이드 수용액을 활용하여 실제 온실에 적용된다면 기존 온실에서 사용하고 있는 냉방 및 제습 방법에 비해 에너지 절감을 통한 경제적 효과를 얻을 수 있을 것으로 판단된다. 향후, 제습 부분은 시뮬레이션을 통한 분석 및 실험결과와 대비 검증이 요구되고, Lab scale의 제습 시스템에 서 Farm scale의 온실 규모로 확장하여, 추가 변수에 대한 제습 및 냉각 연구가 수행되어야 할 것이다.
        4,000원
        119.
        2014.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This research is to investigate the cooling performance analysis of the heat sinks for LED light with four different fin types and two different fin numbers (16EA and 64EA) of heat sinks. Temperature distributions of fins over the flow domain are numerically calculated for the optimum design of heat sink fin types with uniform initial temperature of the bottom of the fins. According to the calculations of convective heat transfer coefficient between fin and atmosphere in the flow domain, S-curve fin type of heat sinks with 64EA of fins reveals the highest cooling performance of the heat sink fin types in the present cooling heat sink model.
        4,000원
        120.
        2014.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This research is to investigate the performance analysis of cooling fan of the IT and electronic device with two different blade types and three different blade numbers of the cooling fan. Velocity, and temperature distributions of fluid over the flow domain of the flow channel are numerically calculated for the optimum design of flow channel with uniform inlet velocity. According to the calculations of convective heat transfer coefficient between blade and atmosphere in the flow domain, case 2 with 6 blases type shows highest performance of the cooling fan shapes in the present cooling fan model considering manufacturing process and cost
        4,000원