This paper analyzes the footing shift by focusing on an interviewer’s questioning from the conversation of a Korean TV news interview. By dividing the interviewer’s questions into adversarial questions and non-adversarial questions, this study investigates what footing shift functions and what the interviewer wants to achieve through it. The analysis of the news interview reveals that footing shift in adversarial questions performs a function of defense. The interviewer attributes the responsibility of remarks that criticize and refute interviewees to a third party so that they can defend themselves against the criticism of attacking interviewees. On the other hand, the footing shift in non-adversarial questions is used to introduce a new topic to the conversation. The interviewer speaks on behalf of a third party when the new topic indicates one’s position on a contentious topic. It enables the interviewer to entirely conceal his personal opinion and lead the discussion in depth. In conclusion, footing shift in questions allows an interviewer to satisfy institutional demands of the news interview. Furthermore, it is found that interviewees collaborate to preserve the interviewer’s stance of footing shift in their responses.
지반-기초 상호작용계를 해석할 때 실제로 지반은 다양한 지반종류와 다층으로 형성되어 있으므로 지반 특성의 변화를 고려해야 한다. 초기의 대부분의 상호작용계의 정동적 해석은 지반의 복잡한 성질을 역학적으로 탄성거동을 한다고 가정한 Winkler 지반모델 혹은 지반을 등방성이고 균질한 반무한 탄성체로 가정한 반무한 탄성지반 모델로 보아 수행되었다. 본 연구는 유한 요소법을 이용하여 지반-기초 상호작용계의 동적 거동을 해석하기 위해 기초는 4절점 후판요소를 사용하고 지반은 지반특성을 고려할 수 있도록 8절점 6면체 요소를 사용하였고, 지반의 감쇠효과 및 지반특성을 고려한 지반-기초 상호작용계의 동적 거동을 유한요소법으로 해석하고 지반의 영향범위를 결정하는 것이다.
This research provides techniques for the implementation of an integrity evaluation system developed for wind turbine structures to jack-up barge. The strain values obtained from the upper tip of the footing are to be converted into values at a single point in order to represent the structural behavior. These obtained values are evaluated simultaneously through P-M curve, generated by FEM results. Evaluating loads with P-M curve, structural stability of barge could then be monitored.
Due to expansion of service environments for the Jack-up barge, the design of the footing has been improved. In this paper, the structure analysis of the modified spudcan based on DNV-OS-C201 examples was assessed.
말뚝머리-확대기초 접합부는 상부구조물의 하중을 말뚝으로 전달하는 연결부분으로서 부재의 단면과 강성의 급격히 변화하는 부 위이기 때문에 응력이 집중되고 작용하는 휨모멘트와 전단력이 큰 취약부분이다. 이 연구에서는 제작조건에 따른 PHC말뚝 및 합성 PHC말뚝 과 확대기초 접합부의 구조성능을 평가하는데 목적이 있다. 반복가력 하중 조건하에서의 균열패턴, 하중-변위관계, 연성비, 초기 회전강성 및 에너지소산 특성을 각각 평가하였다. 접합부 초기 회전강성은 확대기초 내부로 삽입되는 말뚝삽입 깊이와 축방향철근 배근위치에 큰 영향을 받는 것으로 나타났다. 또한 접합부 강도, 연성비 및 누적 에너지소산 등의 접합부 거동은 말뚝의 종류와 축방향 철근 배근 위치에 영향을 받는 것으로 나타났다.
We studied design and structural analysis of jack-up barge footing system that can be safely and quickly installed offshore support structure. In this paper, we checked the buckling strength for a structural member in spudcan based on DNV-RP-C201
In the remodeling underpinning, Connection between pile and footing is very important considering load transfer aspect. In this paper, the 3type construction cases of connection is introduced.
In this paper, we present requirements for the spudcan footing of jack-up barges, we take a survey about jack-up barges and their limitation. And by using the result of the survey, we find the failure modes and requirements for design of the footing.
This Paper evaluates the effect of Shear Design Article of KCI 2012 on the isolated footing of 15-story and 25-story frame type apartment buildings of which an apartment unit area is 59m2. As a result, the footing depth of a 15-story building shows 30.7% increase, and 25-story one, 39% increase, respectively. The minimum footing depth of isolated footing to resist pile punching is 750mm for a 15-story building and 830mm for a 25-story one.
Blades of wind farm structures should be designed to maximize the capacity generating lift force in the specific range of wind velocity. Although many studies related to wind farm efficiency have been performed but it is few to secure safety in the environment of high wind velocity. This study uses Computational Fluid Dynamics to analyze wind load on the blade and member force transferred to footing. And it is analyze wind load property variation related to the turbulence intensity because the wind property variation can be affected to generate the unstable motion on the blade, tower and footing. The maximum force loaded on the footing can be affected to the response of structure. The load variation by turbulence intensity can be considered when design the wind farm structures.
최근들어 매스콘크리트 구조물의 시공이 증가 추세에 있다. 이러한 매스콘크리트는 수화열상승으로 온도균열이 발생할 수 있다. 온도균열을 방지하기 위하여 일반적으로 프리 쿨링, 파이프 쿨링 및 타설높이를 제한하는 방법이 사용된다. 본 연구에서는 교각 기초의 온도균열을 방지하기 위하여 열응력 검토를 실시하였으며, 이때 기초는 12m×14m의 면적과 3m 높이를 가지는 것을 모델로 하였다. 타설 높이를 제한하는 방법과 파이프 쿨링에 의한 해석결과를 비교 검토 하였다. 온도응력를 해석한 결과 지반위에 타설한 기초매트는 타설높이를 제한하는 방법과 파이프쿨링 방법에 의해 균열을 제어할 수 있다.