        21.
        2017.04 서비스 종료(열람 제한)
        PSC girder bridges, widely applied to bridge and railroad bridge (25 ~ 50 m), are a type of bridge that introduces compressive force in advance to the part where tensile force of concrete is generated. The tension force for introducing the compressive force by inserting the tendon into the concrete is a key element of the structural performance in the PSC. At present, however, measurement and verification of this is indirectly managed through deflection and cracking. However, it has become more necessary to develop practical evaluation methods of prestress force of PSC bridges. In this experiment, a small scale PSC beam with various curvature radii was made. Tension force monitoring with FBG sensor and EM sensor was performed on test members using 3 point flexural loading test. The measured values of the FBG sensors and the EM sensors used in the experiment were analyzed and compared with the measured values of the load cell.
        22.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        PSC girder bridges, widely applied to bridge and railroad bridge (25 ~ 50 m), are a type of bridge that introduces compressive force in advance to the part where tensile force of concrete is generated. The tension force for introducing the compressive force by inserting the tendon into the concrete is a key element of the structural performance in the PSC. At present, however, measurement and verification of this is indirectly managed through deflection and cracking. However, it has become more necessary to develop practical evaluation methods of prestress force of PSC bridges. In this experiment, a small scale PSC beam with various curvature radii was made. Tension force monitoring with FBG sensor and EM sensor was performed on test members using 3 point flexural loading test. The measured values of the FBG sensors and the EM sensors used in the experiment were analyzed and compared with the measured values of the load cell.
        23.
        2015.10 서비스 종료(열람 제한)
        A PSC girder with I-typed section is one of the most common types applied to road and rail bridges in South Korea. As public service life of PSC bridges is on increase, lots of effort has been devoted to verify safety of PSC bridges. On the safety of PSC bridges, effective prestress force is one of the most important factor. At the current time, however, indirect measurements are mostly employed to measure the effective prestress force during construction. In this study, performances of FBG and EM sensors, which can directly measure the effective prestress force, are tested and investigated. The test result can be useful to develop block-out PSC girders with FBG and EM sensors monitoring effective prestress force during service life.
        24.
        2015.04 서비스 종료(열람 제한)
        In this study, long term monitoring of tensile force of pre-tensioned prestressing strand embedded in UHPC ribbed deck by means of FBG sensor encapsulated into 7-wire prestressing strand. Based on the monitoring result for two years, it was confirmed that the technique proposed in this study offers efficient and robust way of monitoring the internal prestress of pre-tensioned PSC structures.
        25.
        2015.04 서비스 종료(열람 제한)
        When prestressing tendons are placed with non-equal prestressing forces, restoring forces(torsional moment and bimoment) are occurred. Restoring forces was derived based on the theorem of virtual work for the purpose of controlling the torsional rotation. Numerical analysis was carried out on the existing double-T beam to clarify that the torsional rotation could be controlled by restoring forces.
        26.
        2015.02 서비스 종료(열람 제한)
        Prestressing steel is an effective means of increasing the load carrying capacity and control the deflection of structural steel members. Although the method of prestressing is not new, the application and development of the technique for steel members has been limited and not as advanced as prestressed concrete structures. Prestressing force is commonly introduced using hydraulic jacks and utilizes high strength tendons as the prestressing material. In this paper, a new method of applying prestressing force is introduced. The method involves a segmental beam consisting of three segments and a normal strength bottom plate (BP) as the pretressing material attached to the two initially inclined outer segments of the steel H-beam. Pretressing force is introduced by taking advantage of the geometry of the segmental assembly of the beam. Experiment, analytical studies, and finite element (FE) analysis using ABAQUS is performed to verify the feasibility and applicability of the method and to understand the behavior of a mechanically prestressed segmental steel beam. Results showed that the prestressing method significantly increases the load carrying capacity and at the same time reduces the deflection of the beam. The difficulties encountered in the method are the rigorous assembly and the introduction of the exact required amount of prestressing force. Overall, the method of prestressing performed in the study can be used to introduce pretressing force which improves the performance of steel beams, provided that proper detailing is implemented.
        27.
        2014.10 서비스 종료(열람 제한)
        To evaluate the prestressing loss of tendon caused by deflection angle, test is conducted with the variables of a deflection angle and a diameter of deviator head. Results show that the prestressing loss increases when the delfection angle increases but the diameter of deviator head gives no significant influence on the prestressing loss.
        28.
        2014.04 서비스 종료(열람 제한)
        This paper investigated experimentally the feasibility of estimating stress in prestressing strands using induced magnetic field by an external electromagnet and Villari effect that the permeability of ferromagnetic material varies according to its stress or strain.
        29.
        2014.02 서비스 종료(열람 제한)
        현재 국내에 건설되고 있는 도심지내 고가도로 및 중소형 교량의 경우 일반적으로 교각 기둥 상부에 코핑부가 설치되며, 그 위에 거더가 놓이는 형식을 대부분 사용하고 있다. 하지만 이와 같은 형식에서의 코핑부는 큰 부피와 투박한 형상으로 인해 시각적 개방감을 저하시키는 비 친화적인 구조물로 인식되고 있다. 코핑-거더 일체형 강교량은 이와 같은 단점을 개선하고자, 코핑부를 거더의 높이 내에 위치시켜 상호 일체화함으로써 형하공간의 확보를 통한 하부차로의 공간 확대 및 미관향상의 장점을 지닌다. 본 연구에서는 코핑-거더일체형 강교량의 연결부 실물실험 결과를 토대로 유한요소 해석을 실시하여 수치해석적으로 획득한 변위 및 변형률 값을 비교, 분석하였다. 또한 코핑-거더 일체형 강교량의 구성요소 중 PC강봉에 가해지는 긴장력을 매개변수로 비선형 유한요소해석을 진행하여 코핑-거더 일체형 강교량 연결부의 구조적 성능을 분석한다.
        30.
        2013.04 서비스 종료(열람 제한)
        To evaluate the efficiency of the FBG sensors encapsulated into 7-wire strand, a field test for the UHPC girder bridge was performed using both FBG sensors and the conventional strain gages. Variations of prestressing forces from FBG sensors are compared to the values from the strain gages after this test.
        31.
        2012.05 서비스 종료(열람 제한)
        The main objective of this paper is to investigate the static behavior of a prestressed concrete (PSC) girder. The monolithic girder has the same geometric and material properties with respect to the splice girder. In this study transverse prestressing method was treated to connect girders as an application of modular technology, and various experiments were performed to measure a connection capacity and to evaluate structural behaviors between double T-girder.
        32.
        2012.05 서비스 종료(열람 제한)
        The existing Full-staging method(FSM) has problems of economic efficiency and clearhead decline due to short applicable span length. This study proposes the thermal prestressing method (TPSM) with eccentric bracket in FSM. The study contains an analysis of TPSM as well as static loading analysis for the proposed method. It was verified that sectional stiffness of applied H beam girder is increased and ultimate strength is improved as well.
        33.
        2010.03 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 해석의 결과 내부 지점부 보강과 외부프리스트레싱의 도입이 일반 플레이트거더교의 단면보다 단면감소의 효과가 있음을 확인하였으며 특히 외부프리스트레싱의 도입으로 얻은 솟음은 교량의 처짐을 감소시켜 사용성 측면에서 긍정적인 효과를 나타냄을 확인하였다. 해석결과를 바탕으로 하여 거더 개수 별 적용가능 단면을 도시 하였으며, 거더 개수가 4개일 경우에 한하여 회귀분석을 시행해 회귀식을 제시함으로써 추후에 이와 같은 단면을 사용할 때 응력예측을 가능할 수 있게 하였다.
        34.
        2009.11 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 RC 중공슬래브 교량의 내하력을 향상시키기 위해 외부 프리스트레싱을 이용한 보강방법을 제시하였다. 효과적인 보강을 위해 Queen-post 형식과 King-post 형식이 고려되었으며, 축차무제약 최소화 기법(SUMT)를 이용하여 목표 내하율을 달성하기 위한 최적의 형상과 긴장력을 구하였다. 최적보강을 위한 목적함수는 재료비용을 무차원화한 비용함수로 구성하였으며, 제약조건은 시방서 규정과 내하율을 고려하여 형성하였다. RC 중공슬래브 교량의 보강을 실행한 후 그 결과를 분석하여 제안된 방법의 타당성을 제시하였다.
        35.
        2009.09 KCI 등재 서비스 종료(열람 제한)
        본 논문은 이론으로 개발된 FEM과 HGA의 조합을 이용한 외부 긴장재의 손실 긴장력 평가에 대한 실험적 검증과 현장 적용에 대하여 소개한다. 외부 긴장된 텐던에 대한 모형실험과 현장실험을 통하여 진동실험이 수행되었고, 진동실험으로부터 고유진동수를 획득하였다. 추출된 고유진동수를 기반으로 제안된 기법이 적용되었고, 모형실험으로부터 추정장력과 추정 긴장 손실량은 4%이내의 오차를 보여주었다. 또한 현장실험에서는 Rayleigh 댐핑이 고려된 현장 시스템에 대한 정확한 모델이 모사되었다. 제안된 기법을 적용하여 1%이내의 장력이 추정되었고, 추정된 긴장 손실량은 실제값보다 작은 값으로 수렴되었다.
        36.
        2009.09 KCI 등재 서비스 종료(열람 제한)
        본 논문은 외부 긴장된 긴장재의 손실 긴장력 추정에 대한 새로운 방법을 소개한다. 제안된 방법은 HGA과 FEM이 조합된 시스템 인식 기법으로 외부긴장된 긴장재의 손실된 긴장력이 추정된다. 제안된 기법의 인식변수로는 외부긴장 긴장재의 긴장력, 유효공칭직경, 단위길이당 질량과 레일리 감쇠 계수가 사용되었다. 첫째로 감쇠의 효과가 적용된 유한요소 모델 시스템을 모형화되고, 시스템 인식변수를 반복적으로 추정하는 역해석 기법을 이용하여 인식하게 된다. 마지막으로 3번의 수치실험을 통하여, 제안기법의 수치적 타당성 여부가 확인된다. 이때, 레일리 감쇠 계수를 제외한 인식변수들의 오차는 1%미만으로 인식된다.
        37.
        2009.07 KCI 등재 서비스 종료(열람 제한)
        본 연구는 다단계 온도프리스트레싱 공법으로 보강된 합성보의 하중재하 실험 및 구조해석을 통하여 온도프리스트레싱 공법의 프리스트레스 도입효과와 단면증가효과를 평가하였다. 연구결과 온도프리스트레싱을 이용한 합성보의 보강공법은 온도프리스트레싱에 의한 프리스트레스 도입 뿐 아니라 커버플레이트의 설치에 의한 단면증가로 합성보의 처짐 또한 감소시킬 수 있으므로 합성보의 효율적인 보강공법으로 적용이 가능할 것이다.
        38.
        2008.09 KCI 등재 서비스 종료(열람 제한)
        본 연구는 콘크리트에서 인발실험(pullout test)을 통해서 인장을 가하지 않은 강연선의 부착특성을 파악하기 위한 것이다. 인장을 가하지 않은 강연선의 부착특성은 이형철근이나 인장이 가해진 강연선과는 다르게 나타난다. 본 연구에서 인장을 가하지 않은 강연선을 철근과 같은 용도로 사용하고 설계하기 위해서는 인장을 가하지 않은 강연선의 부착특성에 관한 연구가 필요하다. 본 연구는 묻힘 길이(10db~60db), 콘크리트 피복두께(45mm, 70mm, 100mm), 그리고 강연선의 직경(12.7mm : SWPC7B, 9.3mm : SWPC7A)을 주요변수로 선정하였다. 실험결과, 묻힘길이가 증가함에 따라 상대적으로 평균부착응력은 감소하는 경향을 보여주고 있으며, 묻힘길이가 60db 이상 확보된다면 인장을 가하지 않은 강연선의 부착성능에 기여할 수 있을 거라 판단된다.
        39.
        2006.09 KCI 등재 서비스 종료(열람 제한)
        일반적으로 PSC 교량은 여러개의 강선을 포함하며, 이러한 강선들의 긴장순서에 따라 정착부의 파열력의 크기는 좌우된다. 그럼에도 불구하고 강선긴장순서에 대한 연구부족으로 강선긴장시 긴장순서를 설계자의 경험이나 직관에 의하여 결정하고 있다. 본 연구에서는 정착부의 파열력을 산정하는 여러 방법에 대하여 고찰한 후, 가장 합리적인 해석방법을 선택하여 PSC 교량중에서 가장 대표적인 PSC빔교와 PSC박스거더교에 대하여 해석을 통한 합리적인 긴장순서를 결정하였다. 본 연구에서 제시한 방법은 PSC교량 정착부의 파열력을 최소화하는 강선긴장순서 결정에 유용한 방법이 될 것이다.
        1 2 3