This study sought to conduct a fundamental investigation in order to test and evaluate the thermal performance of an aluminum stick curtain wall system. In terms of the thermal performance index, the infiltration rate of air tightness, thermal transmittance of the heat insulation property and temperature difference ratio of condensation resistance were experimentally measured. The research process can be divided into three parts. First of all, a database for the test report of the curtain wall was compiled and existing design criteria with respect to the evaluation method and standard of transparent building components such as curtain wall, window and door were analyzed to produce the specimens. Secondly, four different types of curtain wall specimens were created through investigating the curtain wall database. Thirdly, standard tests of thermal performance were carried out for airtightness, thermal performance and condensation resistance. As a result, the curtain wall specimens with low-e triple glazing covered by an aluminum capture system showed high thermal performance compared to other curtain wall specimens including low-e triple glazing with a 4-sided structural sealant glazing system. Air tightness of all types of curtain wall specimens satisfied level 1 standard for air tightness. It was found that a curtain wall which consists of a one track frame has difficulties meeting the residential standard of thermal performance with regard to thermal transmittance and condensation resistance.
of the marketed multi-later insulating curtain was carried out. Experiments is conducted by fabricating a test apparatus for investigating the heat flux characteristics. The multi-later insulating curtain used for the experiment was compared using the P, N, S, U and T company, which are commercially available, and the heat flux due to temperature difference between the experimental apparatus and the outside was compared and analyzed. When the internal temperature of the experimental result is the maximum temperature 60℃, the heat flux of multi-later insulating curtain is T Co.(73.1W/m2) > S Co.(119.5W/m2) > U Co.(155W/m2) > N Co.(163.1 W/m2) > P Co.(177.7W/m2). The heat flux means the quantity of heat passing through the unit time per unit area, and the higher the numerical value, the higher the quantity of heat passing through the multi-layer insulating curtain. This can be determined that high heat fluxes produce low heat resistance. Further, it has been found that the weight of the insulating curtain is largely unrelated to the heat insulating property, and the heat insulating curtain having a thickness containing a high internal air layer is excellent in the heat insulating property. In the future when manufacturing a heat insulating curtain, It is judged that it is desirable to manufacture a combination of heat insulating materials that contain a high internal air layer content and that can maintain the air layer even for long-term use while minimizing the volume.
본 연구는 우리나라 온실 피복재의 결로 발생을 억제하는데 필요한 기초자료를 제공하기 위하여 토마토 재배용 실험온실의 포차변화 및 피복재에 발생하는 결로량의 변화를 분석하였으며 결과를 요약하면 다음과 같다. 실험온실의 경우 포차가 병 발생을 유발하기 쉬운 한계포차인 0.2kPa보다 더 크게 유지되어 온습도환경이 양호한 것으로 판단되었고 제습여부 결정을 위한 임계포차인 0.5kPa보다는 작게 나타나 제습은 필요한 것으로 판단되었다. 내부피복재의 표면온도는 외부온도와 커튼상부온도의 평균값 보다 약간 더 큰 것으로 나타났으며, 대체로 외부온도의 변화에 비례하여 변화하는 것으로 나타났다. 외부의 온도 및 습도 변화에 상관없이 커튼 상부의 습도는 거의 100%에 가까운 상대습도를 유지하여 결로 발생이 용이한 조건인 것으로 나타났다. 커튼하부의 습도는 내부습도의 큰 변화에도 불구하고 75~90% 정도로 안정된 값을 유지하였으며, 이는 온풍난방을 실시하여 온도를 15℃로 유지하였기 때문으로 판단된다. 실험조건 및 피복재의 종류에 따라 결로 발생량은 많은 차이가 있는 것으로 알려져 있다. 실험온실의 결로 발생량은 Seginer와 Kantz(1986)의 연구결과와 가장 잘 일치하는 것으로 나타났으나 다른 온실실험 결과들과는 약간의 차이를 보여주고 있기 때문에 앞으로 실험을 통해서 더 자세한 검증을 거친다면 우리나라 온실 피복재에 발생하는 결로량을 분석하는데 유용하게 활용될 수 있을 것으로 기대된다.
겨울철 난방연료가 많이 소모되는 대규모 연동형 온실의 보온성을 향상시키기 위해 터널용 보온자재로 많이 사용되는 다겹보온커튼을 이용하여 기존의 부직포, 알루미늄스크린 등과 보온성을 상대적으로 비교하였다. 또한 다겹보온자재는 보온성이 높으나 두께가 두꺼워 전동모터를 이용한 자동개폐장치를 구성하기 어려운 단점이 있으므로 연동형 온실에 적용할 수 있는 고장이 적고 작동이 원활한 커튼 개폐장치를 개발하여 작물재배 및 난방연료 절감효과를 검토하였다. 다겹보온자재와 부직포, 알루미늄스크린 등의 보온커튼용 자재의 열 관류량을 측정하여 상대적인 보온효과를 비교한 결과 부직포에 비해 알루미늄스크린의 열관류량이 적었고, 알루미늄 및 화학솜의 3겹보온자재와 다겹보온자재는 알루미늄스크린에 비해 열관류량이 각각 23.3%, 43.0% 적게 나타나 다겹보온자재의 보온성이 우수한 것으로 판단되었다. 다겹보온자재는 여러 겹으로 누빈 조합형 보온자재이므로 두께가 두껍고 화학솜, 폴리폼 등 연신되기 쉬운 자재를 이용하므로 장기간 사용시 커튼 개폐장치의 예인선이나 보온자재가 처지게 될 우려가 있으므로 예인식과 권취식 개폐방법을 동시에 적용하여 보온커튼 개페장치를 구성하였다. 시험용 온실 에 다겹보온커튼과 부직포커튼을 설치하고 풋고추를 재배한 결과 다겹보온커튼 설치 온실에서 풋고추의 생육이 유리하였고 초기수량도 27% 정도 증수되었으며, 경유온풍기의 난방연료 소모량은 46%정도 절감되었다.