We compared the Load transfer area of the composite column rechargeable through FEM in this study. We compared by the method of comparative analysis of the Abaqus program. Load transfer is easy to position the stud in the same transmission with the load direction, and the stud is to be arranged densely in the FEM is KBC2009 and KBC2013. We serve as resources for establishing a non-diaphragm type filled composite column standard through shear connectors in Load transfer area with this result.
The purpose of this study is to evaluate the seismic performance of unreinforced masonry(URM) building more accurately. For that, the nonlinear hysteresis models of preceding research did not validate for dynamic analysis. Therefore, in this study, we compared the results of the shaking table test and dynamic analysis. As a result, nonlinear hysteresis models are expected to be applicable.
Recently climate change have increased consumption of building heating and cooling energy. Furthermore, the study on energy reduction is important. Especially the outer covering of the building has been made of concrete more than 70%. The study is to evaluate durability of concrete using insulation performance improvement materials.
The pipe system for underground cable can be damaged by shock and corrosion under the various types of upper load. The existing protective systems have many problems because of constructivity and maintenance. Therefore, this study presents the protective system for underground cable pipe and evaluates the field application according to upper load.
It is necessary to secure the safety for the horizontal capacity of solar tracker system. Therefore, this study evaluates the structural capacity of the horizontal connections through the structural experiment under various variables.
In this study, the hydration characteristics in winter of low heat concrete with respect to the binder type are investigated experimentally. According to the research results, TBC1(Ternary Blended Cement) applied low heat concrete, the heat of hydration was found to be reduced and the 28 days compressive strength was superior to that of other TBC mixes.
Tensile stress and strain of rear by shock wave become the cause of rear side scabbing of concrete subjected to high-velocity impact. Improvement of flexural and tensile performance by fiber reinforcement has great effect on the suppression of the rear scabbing.
In this study, local fracture of concrete was evaluated through high-velocity impact test. As results, increase of bending tension performance by fiber reinforcement did not affect penetration depth Control, but it decreased rear side fracture thickness and diameter. Therefore, it was observed that fiber reinforcement decreases scabbing limit thickness.
A new system to ensure fire resistance of high strength concrete column in high-rise building with an permanent formwork made of insulation materials has been being studied. In this study, the lateral pressure safety performance of concrete column member using newly develope permanent formwork was estimated.
In this study, impact of high-velocity projectile by mixing steel fiber, polyamide, nylon, polyethylene fiber which have different shape and properties respectively. Scabbing is restrained because of micro-crack caused by the shock wave offset effect and energy dispersive of synthetic fibers are mixed populations.
The purpose of this study is to investigate the field application of cold-mixed recycled asphalt using cementless binder. After the test construction, it was not cause problem, such as this stripping, falling and crack of pavement. Also, it was confirmed to be performance of equal or higher than of existing technology.
Based on the study of current status for domestic port facility management system, it was used to collect information for building the ocean & port facility integrated management system.