검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 312

        81.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study develops numerical model of mega composite columns in fire and investigates the residual areas using 500℃ isotherm method and residual capacity of mega composite columns after 3 hours. In order to perform heat transfer analysis, thermal properties of steels and concrete were adopted from Eurocodes. In addition to, the temperature distributions of composite columns with respect to fire tests were compared with numerical analysis results. As a result, residual capacity of mega composite column with 1m width remained more than 45%. The residual capacity of mega composite column was only increased to 2.3∼2.6% with the use of additional rebars.
        4,000원
        82.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        컨테이너를 이용한 위험물의 해상운송이 증가함에 따라 적재불량으로 인한 위험물의 누설 등으로 선박에서 화재사고가 발 생하고 있다. 한편, IMO(MSC.93)에서는 2016년 1월 1일 이후 건조되는 개방갑판상에 컨테이너를 5단 이상 적재하도록 된 모든 선박은 물분무창(Water Mist Lance, WML)이라는 소화장치를 선박에 의무적으로 비치하도록 규정하였다. 본 연구에서는 LS-DYNA를 이용하여 최적의 첨단곡률반경을 가지는 WML을 설계하기 위한 수치해석을 수행하였다. 첨단부분의 길이가 10 mm, 15 mm, 20 mm인 3가지 모델에 대한 해석결과 길이가 15 mm인 경우만 컨테이너 벽면을 관통하고, WML의 첨단부분에 손상을 일으키지 않는 결과를 나타내었다. 향후, 본 연구결과를 바탕으로 테스트용 WML를 제작하여 성능실험을 할 계획이며, 문제점은 지속적으로 개선해 나갈 것이다.
        4,000원
        83.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        선박 거주구역에 화재발생 시 화재시뮬레이션 도구를 이용하여 화재확산형상을 실시간으로 예측하고 상황에 따른 적절한 대응방안을 제시할 수 있다면 화재사고로 인한 인명피해를 최소화시킬 수 있을 것으로 예상된다. 그러나 오늘날 화재시뮬레이션은 해 석대상공간의 크기와 그리드 개수에 따라 해석을 하는데 있어, 매우 장시간을 필요로 하는 현실적 한계가 있다. 이에 이 연구에서는 화재시뮬레이션 시간단축을 목적으로 선박 거주구역 화재시뮬레이션에 적용할 수 있는 격자크기와 생성방법에 대한 연구를 수행하였 다. 연구결과 선박 거주구역에 적용되는 격자크기는 0.25[m] 이내의 값을 사용하는 것이 가장 효율적인 것으로 판단되었다. 또한 single mesh 격자생성방법으로 수행했을 경우와 비교하여, multi mesh 격자생성방법으로 시뮬레이션을 수행하였을 때 가시거리 값은 4.3 %, 온 도 값은 8.3% 이내에서 유사하고 해석시간은 약 80% 감소하였기 때문에, multi mesh 방법으로 격자를 생성하는 것이 해석시간을 단축 하는데 있어 매우 효과적임을 확인하였다.
        4,000원
        84.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The occurrence of unexpected disasters, including fire events, increases as the road network becomes complicated and traffic volume increases. When a fire event occurs on and under bridges, the damage extensively influences direct damage to structures, vehicles, and human life and secondary socioeconomic issues owing to traffic blockage. This study investigated potential fire-hazard risks on bridges of the Korean national route roadMETHODS: The investigation was conducted using field investigation and analysis with satellite pictures and road views from commercial websites and the Bridge Management System (BMS). From the filed investigation, various potential fire resources were identified. The satellite pictures and road views were helpful in measuring and recognizing conditions underneath bridges, stowage areas, etc.RESULTS : There are various potential fire resources underneath bridges such as piled agricultural products, parked petroleum tanks, construction equipment, and attached high-voltage cables. A total of 94.6% of bridges have underneath clearances of less than 15 m. A bridge underneath volume that can stow a potential fire hazard resource was 7,332 m3 on average, and most bridges have about 4,000 m3 of space. Based on the BMS data, the amounts of PSC and steel girders were 29% and 25%, respectively.CONCLUSIONS : It was found that the amount of stowed potential fire hazard resources was proportional to the underneath space of bridges. Most bridges have less than 15 m of vertical clearance that can be considered as a critical value for a bridge fire. The fire risk investigation results should be helpful for developing bridge fire-protection tools.
        4,200원
        85.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A number of plating companies have been exposed to the risk of fire due to unexpected temperature increasing of water or other reasons in a plating bath. Since the companies are not able to forecast the unexpected temperature increasing of plating bath and most of raw materials in the bath have low ignition temperature, it is easy to be exposed to the risk of fire. Thus, in previous study, we tried to monitor and notice the dangerous change of temperature of water immediately to prevent the risk of fire from plating process. However, unfortunately previous studies were not able to shut out the fundamental cause of fire since bath temperature sensor can detect air temperature when the level sensor was malfunctioned. In this paper we developed the Teflon heater which contains a built in temperature sensor and improved plating equipment system. Teflon heater is improved using Pt 100Ω sensor which can detect until 600°C . When the bath temperature sensor detects over 60°C or the Teflon heater sensor detects over 240°C they temporarily shut down the heater to control temperature. Also relay completely shuts down main power when detects instant temperature is detected over 5% of 240°C by the heater sensor to prevent teflon melting down and fire spreads. Developed plating equipment system can monitor a real time temperature in the teflon tube and bath water. Therefore we think the proposed plating equipment can eliminate the possibility of fire in plating processes fundamentally.
        4,000원
        86.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study attempted to establish fire risk factors and preventive measures for each of five major types of construction, focusing on construction sites. For this purpose, disaster cases were analyzed and countermeasures were prepared. In addition, fire risk factors and flammable and combustible materials by construction type according to construction process were identified and preventive measures thereof were suggested. The results of this study can be used to establish policy improvement directions that meet various educational needs and expectations by identifying the use status of flammable and combustible materials and figuring out the fire risk factors according to the process by work type in construction sites.
        4,600원
        90.
        2017.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To minimize and prevent the increasing fire and personal injury, the domestic firefighting organizations are making continuous efforts to strengthen the response system and safety standards. "Fire Reduction Program" has been prepared to reduce the outbreak of fire up to 20% in the next 10 years, and the analysis of fire sources should be done and its countermeasures also should be done accordingly. Therefore, the management status, the improvement tasks, and the limitations of the implementation plan are reviewed and studied so that the implementation and goal of the "Fire Reduction Policy" can be achieved
        4,000원
        91.
        2017.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The study seeks to cooperate with the investigation of a fire investigation based on public-private partnership. Fire protection systems provide a wide variety of viewpoints from the perspectives of design, construction, management, maintenance, maintenance and maintenance systems at a particular point in time, construction, management, and maintenance systems. What is controversial is that there are illegal activities such as illegal activities of the Patent Office, misconduct of construction work and unreasonable construction of construction works.As a theoretical framework, the present study identified the four key elements of a successful disaster response system : responsiveness, control, professionalism, and bias.
        4,000원
        92.
        2017.04 구독 인증기관 무료, 개인회원 유료
        In this paper we developed the Teflon heater which contains a built in temperature sensor and a relay for improved plating equipment system. Teflon heater is improved by using Pt 100Ω sensor which can detect until 600°C. When the bath temperature sensor detects over 60°C or the Teflon heater sensor detects over 240°C they temporarily shut down the heater to control temperature. Also relay completely shuts down main power when detects instant temperature is detected over 5% of 240°C by the heater sensor to prevent teflon melting down and fire spreads. Developed plating equipment system can monitor a real time temperature in the teflon tube and bath water. Therefore we think the proposed plating equipment can eliminate the possibility of fire in plating processes fundamentally.
        3,000원
        95.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        선박의 기계식 환기시스템은 화재발생 시 연기의 생성과 확산 특성에 영향을 미치고, 이는 피난자의 피난경로 상의 가시도를 방해함으로써 피난자의 연기로 인한 피해를 증가시킬 위험성이 크다. 이에 이 연구에서는 선박 거주구역에서 화재발생 시 기계식 급·배기시스템이 연기확산에 미치는 영향과 위험성에 대하여 FDS를 활용하여 평가하고 화재 시 급·배기시스템을 효율적으로 사용할 수 있는 방안을 제안하였다. 연구결과 화재가 발생한 장소에 급·배기시스템이 함께 작동되고 있는 경우에는 현재 권장되고 있는 급·배기시스템을 멈추는 방법보다 작동을 유지하는 것이 효과적이고, 배기시스템만 작동되는 곳에서 화재가 발생한 경우에는 화재가 발생한 구역 이외의 구역에서 급기시스템을 함께 작동시키는 것이 피난시간을 확보하는데 효과적인 것으로 예측되었다. 그러나 화재가 발생한 곳에 급기시스템만 있는 경우에는 급기시스템이 연기확산을 가속시키기 때문에 급기방식을 중단시켜 연기의 확산을 최대한 억제할 필요가 있음을 확인하였다.
        4,000원
        97.
        2016.11 구독 인증기관 무료, 개인회원 유료
        Electric of using in daily life is always exposed to risk of electrical fire and electric shock. Only degree of risk is different, there is no risk free electrical product. Generally, the higher voltage, the risk of electric shock is high. The much electric current, the risk of electrical fire is high. But, we can’t help using electric because of risk and we effort to reduce the risk of electrical fire and electric shock. This study deal with the fire prevention generated on heating equipment using SSR for current
        4,000원
        98.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Currently the forest area is 6,370,000 hectare (ha) which occupies 63.7% in Korea. The forest has good functions such as production of forest products, conservation of national land, prevention of disasters, etc. However constructing houses near the forest area make bad situation like illegal waste incineration by resident. So research subject is forest fire caused by waste incineration place including facility. And this study was conducted about statistical analysis and research analysis of the 100 waste incineration places including facilities at the country town. Statistical analysis shows that March is 27% which percentage is the highest number of forest fire in 10 years’ average. The number of forest fire caused by waste incineration is 45 which is the third highest number in the fire statistic. The distance between waste incineration place including facility and forest area is 30m, 40m and 50m. That 40m (36%) is the most common distance from forest area. The types of waste incineration are ground (62%), the temporary facility made with oil drum can (35%) and other made with steel sheet, concrete, etc. The result of this study is that government and local government must conduct the improvement measure to reduce illegal incineration such as waste pickup area made with rain and wind proof type installed near residence, expenses for waste treatment, enlightenment and training, etc. Also considering their age and income are needed for realistic improvement.
        4,000원
        99.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구는 화재에 노출된 구조물의 역학적 거동을 평가하기 위한 기반연구로서 화재 유동해석과 열응력해석의 통합 프레 임워크를 확립하고 이를 강재와 콘크리트로 이루어진 대표체적에 적용한 결과를 제시하였다. 먼저 Fire Dynamics Simulator(FDS)를 이용해 임의의 화재곡선으로 모델링되는 화원으로부터 구조물 표면까지 유동해석을 실시하였다. 이를 통 해 구조물 표면에서 시간에 따른 온도 분포를 계산하였고, 이 결과를 비선형 열응력해석에 경계조건으로 적용하였다. 이후의 과정은 화재의 성장 또는 감소에 따라 구조물 표면온도의 변화를 반영하는 열전달해석과 구조해석으로 이루어진다. 제시한 통합 프레임워크에 의해 화재 구조해석을 수행한 결과, 강재와 콘크리트의 대표체적 모두 동일한 하중이 작용할 때 상온 조 건에서는 탄성 거동을 보였지만 화재로 인한 온도 조건을 고려할 경우 소성 거동을 보였다. 이는 구조물이 화재에 노출되는 경우 설계하중보다 작은 하중에서도 한계상태에 이를 수 있다는 것을 의미하며, 따라서 원전구조물이나 교량과 같은 중요 사회기반구조물의 설계 시 구조물의 화재거동 평가가 고려되어야 한다고 할 수 있다.
        4,000원
        100.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구는 화재에 노출된 구조물의 역학적 거동을 평가하기 위한 기반연구로서 화재 유동해석과 열응력해석의 통합 프레임워크를 확립하고 이를 강재와 콘크리트로 이루어진 대표체적에 적용한 결과를 제시하였다. 먼저 Fire Dynamics Simulator(FDS)를 이용해 임의의 화재곡선으로 모델링되는 화원으로부터 구조물 표면까지 유동해석을 실시하였다. 이를 통해 구조물 표면에서 시간에 따른 온도 분포를 계산하였고, 이 결과를 비선형 열응력해석에 경계조건으로 적용하였다. 이후의 과정은 화재의 성장 또는 감소에 따라 구조물 표면온도의 변화를 반영하는 열전달해석과 구조해석으로 이루어진다. 제시한 통합 프레임워크에 의해 화재 구조해석을 수행한 결과, 강재와 콘크리트의 대표체적 모두 동일한 하중이 작용할 때 상온 조건에서는 탄성 거동을 보였지만 화재로 인한 온도 조건을 고려할 경우 소성 거동을 보였다. 이는 구조물이 화재에 노출되는 경우 설계하중보다 작은 하중에서도 한계상태에 이를 수 있다는 것을 의미하며, 따라서 원전구조물이나 교량과 같은 중요 사회기반구조물의 설계 시 구조물의 화재거동 평가가 고려되어야 한다고 할 수 있다.
        4,000원
        1 2 3 4 5