검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 22

        1.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this work, we synthesize brilliant yellow color α-FeOOH by controlling the rod length and core-shell structure. The characteristics of α-FeOOH nanorods are controlled by the reaction conditions. In particular, the length of the α-FeOOH rods depends on the concentration of the raw materials, such as the alkali solution. The length of the nanorods is adjusted from 68 nm to 1435 nm. Their yellowness gradually increases, with the highest b* value of 57 based on the International Commission on Illumination (CIE) Lab system, by controlling the nanorod length. A high quality yellow color is obtained after formation of a silica coating on the α-FeOOH structure. The morphology and the coloration of the nal products are investigated in detail by X-ray diffraction, scanning electron microscopy, UV-vis spectroscopy, and the CIE Lab color parameter measurements.
        4,000원
        2.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Fe-based pigments have attracted much interest owing to their eco-friendliness. In particular, the color of nanosized pigments can be tuned by controlling their size and morphology. This study reports on the effect of length on the coloration of β-FeOOH pigments prepared using an NH4OH solution. First, rod-type β-FeOOH is prepared by the hydrolysis of FeCl3·6H2O and NH4OH. When the amount of NH4OH is increased, the length of the rods decreases. Thus, the length of the nanorods can be adjusted from 10 nm to 300 nm. The color of β-FeOOH changes from orangered to yellow depending on the length of β-FeOOH. The color and phase structure of β-FeOOH is characterized by UVvis spectroscopy, CIE Lab color parameter measurements, transmission electron microscopy (TEM), scanning electron microscopy (SEM), and powder X-ray diffraction (XRD).
        4,000원
        3.
        2014.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This work describes the coloration, chemical stability of SiO2 and SnO2-coated blue CoAl2O4 pigment. The CoAl2O4, raw materials, were synthesized by a co-precipitation method and coated with silica (SiO2) and tin oxide (SnO2) using sol-gel method, respectively. To study phase and coloration of CoAl2O4, we prepared nano sized CoAl2O4 pigments which were coated SiO2 and SnO2 using tetraethylorthosilicate, Na2SiO3 and Na2SiO3 as a coating material. To determine the stability of the coated samples and their colloidal solutions under acidic and basic conditions, colloidal nanoparticle solutions with various pH values were prepared and monitored over time. Blue CoAl2O4 solutions were tuned yellow color under all acidic/basic conditions. On the other hand, the chemical stability of SiO2 and SnO2-coated CoAl2O4 solution were improved when all samples pH values, respectively. Phase stability under acidic/basic condition of the core-shell type CoAl2O4 powders were characterized by transmission electron microscope, X-ray diffraction, CIE L*a*b* color parameter measurements.
        4,000원
        4.
        2012.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to assess the influence of patellar height on quadriceps muscles' electromyography (EMG) activity during a squat exercise in adults with patella baja. For the study, we recruited 15 volunteers who had patella baja on the right side. We measured the EMG activity of the right rectus femoris, vastus medialis oblique, and vastus lateralis muscles during squat exercises under two conditions, specifically with and without an infra-patellar strap. The infra-patellar strap was applied below the tested patella to elevate the patella to a normal height. A paired t-test was used to compare the effects of patella height on EMG activity of the quadriceps muscles. The EMG activity of the rectus femoris (RF), vastus medialis oblique (VMO), and vastus lateralis (VL) muscles were significantly decreased during the squat exercise with the infra-patellar strap compared to the same exercise without the infra-patellar strap (p<.05), while the VMO/VL ratio was not different significantly between two conditions (p>.05). The findings of this study suggest that an infra-patellar strap may benefit people with patellar baja, as changes in patellar height could improve the efficiency of the quadriceps muscles.
        4,000원
        5.
        2011.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The effects of an abdominal drawing-in maneuver (ADIM) using a pressure bio-feedback unit (PBFU) were compared to the effects of a pelvic belt (PB) on the muscle activities of the hip and back extensor muscles during hip extension in the prone position. Fifteen healthy male participants all performed prone hip extensions under three conditions: 1) preferred hip extension (PHE), 2) performing an ADIM, and 3) using a PB. The muscle activities of the erector spinae, the gluteus maximus, and the medial hamstring on the right side were recorded by surface electromyography. The muscle activity of the erector spinae was significantly lower while performing an ADIM during prone hip extension than during PHE or with a PB (p<.05). Gluteus maximus muscle activity was significantly higher while performing an ADIM (p<.05). No significant difference was found for the medial hamstring muscle among the three conditions (p>.05). We concluded that the internal stabilization of the pelvis and lumbar spine afforded by the ADIM using a PBFU could be more effective than the external stabilization provided by a PB in terms of increasing selectively gluteus maximus activation during prone hip extension.
        4,000원
        6.
        2011.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to assess visual biofeedback's influence on trunk muscles' (EMG) activity and endurance holding time for correct position during whole-body tilt exercise. For the study, we recruited 14 volunteers who showed no symptom of lumbar disease during medical tests. We measured the EMG activity of their rectus abdominis, external abdominal oblique, internal abdominal oblique and erector spinae muscles, and their endurance holding time for correct position during anterior and posterior whole-body tilt under two conditions: whole-body tilt with and without visual biofeedback. Resistance with gravitational force on the trunk during whole-body tilt was applied by using a device that had a monitor on which the subjects could check their alignment and that sounded an alarm if a subject's alignment collapsed. The study showed an increase in the EMG activity of external abdominal oblique, internal abdominal oblique/rectus abdominis ratio and endurance holding time for correct position during both anterior and posterior whole-body tilt with visual biofeedback compared with without visual biofeedback (p<.05). We suggest that the whole-body tilt exercise with visual biofeedback could be a beneficial strategy for selectively strengthening the internal abdominal oblique muscle and minimizing the rectus abdominis muscle's activity while maintaining correct alignment during whole-body tilt exercise.
        4,000원
        7.
        2010.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate the variations in gait parameters in terms of the type of arm sling used in hemiplegic patients. Ten patients with hemiplegia and ten healthy adults participated in this study and walked at self-selected speeds on a GAITRite-instrumented carpet. The activities of the opposite shoulder girdle muscle including the latissimus dorsi, anterior deltoid, and posterior deltoid were simultaneously recorded using surface EMG during gait. They were randomly assigned a condition: without an arm sling, a single strap arm sling, a Harris hemi arm sling, a Rolyan humeral cuff arm sling, and a Bobath roll arm sling. The following gait variables were analyzed: the temporo-spatial parameters of velocity, step length, stride length, swing phase, stance phase, single support, step time and toe in/toe out. The statistical analysis was one-way ANOVA with repeated measures to compare the variation of each variable. In comparison of parameters in each trial in the hemiplegia group, the non-affected side stride length, single support, and toe in/toe out resulted in statistically significantly changes (p<.05). But without an arm sling group did not show any gait parameter differences with arm slings. This study found that several arm slings varied gait patterns in patients with hemiplegia and in healthy adults. In the EMG analysis, the Rolyan humeral cuff arm sling and the Bobath roll arm sling were higher muscle activity for the latissimus dorsi muscle than did the single strap ann sling. Further study should examine the problems that appeared in patients who worn arm slings by focusing on a larger number of subjects and by studying the variety of responses in more detail using an assessment tool that measures variation.
        4,000원
        19.
        2016.04 서비스 종료(열람 제한)
        An experiment was conducted to recycle sulfur which is industrial by-product, by producing concrete mix materials. production of specimens were implemented on the replacement of modified sulfur emulsion with cement. this paper presents data on the experimental results of durability test of the each specimens.
        20.
        2016.04 서비스 종료(열람 제한)
        An experiment was conducted to recycle sulfur which is industrial by-product, by producing concrete mix materials. production of specimens were implemented on the replacement of modified sulfur emulsion with cement. this paper presents data on the experimental results of strength test of the each specimens.
        1 2