        21.
        2015.01 KCI 등재 서비스 종료(열람 제한)
        Recently a new damper system with Kogome truss structure was developed and its mechanical properties were verified based on the laboratory test. This paper presents a Kagome truss damper external connection method for seismic strengthening of RC frame structural system. The Kagome external connection method, proposed in this study, consisted of building structure, Kagome damper and support system. The method is capable of reducing earthquake energy on the basis of the dynamic interaction between external support and building structures using Kagome damper. The pseudo-dynamic test, designed using a existing RC frame apartment for pilot application of LH corporation, was carried out in order to verify the seismic strengthening effects of the proposed method in terms of the maximum load carrying capacity and response ductility. Test results revealed that the proposed Kagome damper method installed in RC frame enhanced conspicuously the strength and displacement capacities, and the method can resist markedly under the large scaled earthquake intensity level.
        22.
        2014.10 서비스 종료(열람 제한)
        The LH seismic system is composed of structure, brace, and LH damper designed high damping rubber. The dynamic test with shaking table was performed to analyze the vibration characteristic of the RC Frame and LH seismic system.
        23.
        2014.09 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 건물의 질량중심과 면진층의 강성중심 사이의 차이에 따른 면진효과에 대하여 살펴보았다. 면진기술은 면진층에 설치되는 면진장치의 성능에 크게 의존하는 기술이므로 면진장치 제작 후 전수검사를 통하여 면진장치의 수평강성을 검토하게 되어 있다. 하지만면진장치 성능실험 시 각각의 면진장치의 품질기준은 건축기준에는 정해져 있지 않으며, 이로 인해 설계 시 적용된 강성과 실제 강성의 차이가 발생하여 면진층 상부 부재에 큰 문제를 야기할 수 있다. 연구결과, 최대응답변위의 차이는 크게 나타나지 않았으나 편심이 증가할수록 최대응답가속도, 층전단력 및 상부구조의 부재력은 크게 증가하여 일부 부재에서는 과도한 손상이 예상된다. 따라서 면진층은 실제 장치제작 후 전수검사를 실시하여 반드시 설계된 의도대로 편심이 발생하지 않도록 장치를 재배치할 필요가 있으며, 가능하다면 건물의 질량중심과 강성중심의 차이는 동일하게 설계할 것을 추천한다.
        24.
        2014.04 서비스 종료(열람 제한)
        In this paper, the seismic performance of framed building with porous hysteretic damping system is examined by comparing the beam-column stiffness ratio. Analytical results show that in case of maximum displacement, acceleration, and shear force, the decrease in ρ=2.00 is larger than the decrease in ρ=0.10. But results appeared differently according to a number of stories that damper installed.
        25.
        2013.10 서비스 종료(열람 제한)
        Seismic isolation offers an attractive approach for reducing seismic loads in the building and in its components. This paper deals with the seismic isolation effects due to variation in period ratio between superstructure and isolation layer of the building. Seismic isolation effects of the moment-resisting frames with the various period ratio were studied by nonlinear time history analysis. It is recommended that the isolation period should be greater than 2.0 times of that of the superstructure for the effective seismic isolation.
        26.
        2013.04 서비스 종료(열람 제한)
        For coupled shear walls, coupling beams are the first line of dissipation under earthquakes. So coupling beams are important energy dissipation component. When coupling beams have little depth-to-span ratio, routine coupling beams have less capacity of energy dissipation.There are less design methods for coupling beams with depth-to-span less than 2. In this paper a specimen with steel plate reinforcement coupling beam was designed and analyzed by means of FEM software ABAQUS.
        27.
        2013.04 서비스 종료(열람 제한)
        In this paper, the seismic performance of FCW apartment building with porous hysteretic damping system(PHDS) is examined by comparing with the building designed by KBC2009. The results show that even though the seismic force-resisting system is designed to reduce the design seismic base shear by 75 percent, the building with PHDS is enough to satisfy the performances required by the national seismic code
        28.
        2013.04 서비스 종료(열람 제한)
        Diagonally reinforced concrete coupling beam has complicated reinforcement details. To solve this problem, it is necessary to develop the alternative reinforcement details. The objective of this study is to investigate strain characteristics of coupled shear wall according to the replacement ratio of headed-bar.
        29.
        2013.04 서비스 종료(열람 제한)
        Reinforced concrete coupled shear wall systems in medium and high-rise construction, where RC beams couple two or more RC walls have been frequently used. The objective of this study is to investigate seismic behavior of coupled shear wall according to the replacement ratio of headed-bar.
        30.
        2013.01 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 등대 구조물을 대상으로 한 면진기술 적용방안을 제시함으로써 지진에 대해 무방비상태에 놓여 있는 등대구조물의 지진안전도 확보방안을 제시하였다. 또한, 제안된 면진기술 적용방안을 활용하여 내진설계 이전에 지어진 등대를 대상으로 등대전체를 면진하였을 경우와 등대 렌즈만을 면진하였을 경우에 대하여 면진효과를 분석해 보았다. 해석결과, 등대 전체를 면진화하였을 경우 최대응답가속도와 층전단력 측면에서 충분한 면진효과를 얻은 반면, 등대 렌즈만을 면진화한 경우에는 렌즈부의 면진효과는 유효한 것으로 나타났으나 등대 자체의 안전이 확보되지 못한 상황에서는 등대의 파괴가 선행될 가능성이 있음에 주의할 필요가 있는 것으로 나타났다. 또한 등대전체와 렌즈를 동시에 면진화한 경우 비 면진구조 대비 유효한 면진효과는 나타내었지만, 최대응답가속도가 등대전체를 면진화한 경우보다 증가하는 경향을 나타내었으며, 렌즈의 면진화로 인한 층전단력의 감소가 미소함으로 이중면진의 적용으로 인한 실효성은 그 효과가 크지 않은 것으로 나타났다.
        31.
        2012.11 서비스 종료(열람 제한)
        Reinforced concrete coupled shear wall systems in medium and high-rise construction, where RC beams couple two or more RC walls have been frequently used. The objective of this study is to investigate seismic performance of coupling beam with headed bar.
        32.
        2012.11 서비스 종료(열람 제한)
        Coupling beams of coupled shear wall systems are often the most critical members in medium or high rise buildings subject to seismic load or wind loads. To ensure the survival of shear walls under high-intensity cyclic loading, these beams, which normally have limited dimensions, should possess high deformability and good energy absorption while being able to resist large shear force. Experimental work are conducted to illustrate the design of special RC coupling beams using the proposed procedure reinforcement details.
        33.
        2012.11 서비스 종료(열람 제한)
        The coupling beams provide transfer of vertical forces between adjacent shear walls in coupled shear wall system, which creates a frame-like coupling action that resists lots of the total overturning moment induced by the wind load or seismic load. The purpose of this study is to investigate the strain characteristics performance of coupling beams with headed bar.
        34.
        2010.11 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 상부구조에 있어서 보-기둥 강성비 변화에 따른 골조의 특성과 상부구조와 면진층 간의 진동주기비에 따른 면진효과를 분석해 보고, 상부골조의 주기와 목표 면진주기의 설정에 따라 면진효과가 어떻게 달라지는가에 대한 정보를 제공하여 향후 면진건물을 설계하기 위한 기본계획을 세우는데 있어서 필요한 기초 자료를 제공하고자 한다. 그 결과 건물골조의 경우 유효한 면진효과를 얻기 위해서는 최소한 상부구조의 고유진동주기 대비 2.5배 이상의 면진주기를 확보하고, 목표 면진주기를 2.0초 이상으로 설정하여 설계할 것을 추천한다.
        35.
        2009.03 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 최근 계단공사의 시공성 개선을 위하여 새롭게 제안된 Hi-Form 접합부를 대상으로 동특성 정보를 이용하는 계확정기법을 응용하여 접합부의 강성평가를 수행하였으며 해석 시 동 접합부의 합리적인 모델링기법을 제시하였다. 실험 및 해석결과, 균열패턴 및 하중-변형관계 그리고 손상분포로부터 Hi-Form 접합부는 완전한 응력전달을 위한 강접합으로 간주하기 어려운 것으로 나타났으며, 실험결과에 근거하여 Hi-Form 접합부를 약 50%의 강성감소 요소로 모델링 할 것을 제안하였다.
        36.
        2008.09 KCI 등재 서비스 종료(열람 제한)
        본 논문은 기둥형상비를 실험 변수로 가지는 무량판 슬래브-기둥 접합부의 내진성능을 평가하는데 있다. 본 연구에서는 무량판 슬래브의 뚫림 전단파괴를 방지하기 위하여 본 연구와 병행하여 진행된 연구에서 개발된 연속 절곡된 전단보강근을 적용하였다. 기둥형상비에 따른 실험체는 각각 FIS1-05(0.5), FIS1- 10(1.0), FIS1-20(2.0) 이다. 실험체의 수평방향으로 정적 수평하중을 가력 하였으며, 중력하중비에 의한 일정 수직 하중을 적용하였다. 실험결과는 슬래브-기둥 접합부의 수평 변위 및 강도를 기준으로 평가하였다. 분석결과, FIS1-05, FIS1-20와 같은 장방형 기둥을 갖는 접합부의 성능이 FIS1-10와 같은 정방형 기둥을 갖는 접합부보다 우수한 것으로 평가되었다.
        37.
        2006.03 KCI 등재 서비스 종료(열람 제한)
        본 연구의 목적은 면진건물의 설계를 수행하는데 있어, 면진건물의 주기, 수평 변위량 등과 같은 면진장치의 성능을 결정하기 위한 중요 요소들을 손쉽게 산정할 수 있는 포락해석용 도표를 산정하는데 있다. 이를 위하여 가속도로 표현되는 설계지진의 위험도 대신, 에너지와 관계된 VE 스펙트럼을 아울러 산정한다. UBC 97의 지진응답계수를 적용한 경계주기 TG 및 최대속도 응답 V0를 지반조건별로 제안하였으며, 이를 근간으로 한 스펙트럼 작성법을 제안하였다. 제안된 VE 스펙트럼을 근거로 지반조건별 포락해석용 도표를 작성하였다.