검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 33

        21.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzed the appropriate placement method by floor for evacuating all occupants during the nighttime through evacuation simulation. The analysis results are as follows. First, when non-self evacuating patients were placed on the first floor, 266 patients and 6 workers were found to be evacuated after 460 seconds. This result shows that it is meaningful to place non-self evacuating patients on the lower floor with a time that is faster than 540 seconds, which is an evaluation criterion set using life Safety standards for human. This result is a time faster than the evaluation criteria of 540 seconds, which is set using the life safety standards, and it can be confirmed that it is meaningful to place non-self evacuating patients on the lower floor. Next, as a result of placing non-self evacuating patients from the first floor to the fourth floor, it was found that evacuation of all occupants required 460 seconds for the first floor, 834 seconds for the second floor, 1,508 seconds for the third floor, and 1,915 seconds for the fourth floor. These results indicate that the placement of non-self evacuating patients on the rest of the floors, except for the first floor, can lead to dangerous results in excess of 540 seconds, which is a flashover time. As a result, it is necessary to place non-self evacuating patients on a lower floor for safe evacuation. The study has limitations except for comparative analysis of changes in evacuation time due to changes in the number of workers at eldery care hospitals and situations in which fire-fighting facilities such as sprinkler facilities operated. It is necessary to study the evacuation time linked to the operation of the fire-fighting facilities and the evacuation time according to the change in the number of workers in the future.
        4,000원
        22.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzed the evacuation time in indoor stadiums when exits that automatically open/close when the fire sensor is triggered are installed as a means to improve the problem of closing certain exits. Firstly, when spectators on the 2nd floor stands exit through the 1st floor exits, the RSET of all inhabitants was 529.8 seconds when the automatic opening/closing exits are broken and employees are not present. Secondly, when spectators on the 2nd floor stands exit through the 1st floor exits, the RSET of all inhabitants was 445 seconds when the automatic opening/closing exits with 750mm width are working but employees are not present. Lastly, when spectators on the 2nd floor stands exit through the 1st floor exits, the RSET of all spectators was 337 seconds when the automatic opening/closing exits with 1,500mm width are working and employees are present. As a result, it was revealed that the evacuation time is shortened when the automatic opening/closing exits are working. Additional comparative studies with actual simulations of people evacuating an indoor stadium and firefighting simulations considering smoke flow are necessary.
        4,000원
        23.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to explore the effects of fire officers’ experience of traumatic events and subsequent forest healing on their occupational burnout. The results are as follows: First, the experience of traumatic events, social and psychological healing, and relieving stress by strolling had a significant effect on burnout. The more fire officers are exposed to traumatic events, the more they lose self-control in social and psychological aspects, and the lower the level of stress relieved through strolling, the higher the level of burnout. Thi sresult suggests that the more fire office rsare called out for fire fighting, the more they see their colleagues with severein juries, and the higher the level of mental and physical an xiety, the more they areex hausted. Moreover, for es thealing help store duce the irmental and physi calfatig uecaused by traumatic events, thu spreven ting them from suffering from burn out. Second, the experience of traumatic events, social and psychological healing, and relieving stress by strolling had a significant impact on occupational stress. The more fire officers are exposed to traumatic events, the more they lose self-control in social and psychological aspects, and the lower the level of stress relieved through strolling, the higher the level of occupational stress. This result indicates that to relieve job stress caused by fire fighting, increased forest healing activities, including various programs such as psychotherapy, developing interpersonal relationships and self-control, and creating a positive mind-set, can reducejobstress and help fire officers recover from it. Lastly, job stress had a mediation effect on the effects of the experience of traumatic events and forest healing on burnout. This implies that burnout can be prevented when fire officers gain high emotional stability through social and psychological healing and stress-relief strolling over a traumatic experience, and stronger support from the organization and family can keep them from being emotionally drained, thus contributing to the prevention of burnout.
        4,900원
        24.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzed how the installation of a pressure gauge in the indoor fire hydrant of an apartment building affected identifying pressurized water in the pipe, making it easier to conduct internal inspection on the fire suppression system, and ensuring reliability of fire suppression. The following are the study’s results: First, identifying pressurized water in the indoor firefighting pipe had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that a higher level of identification of pressurized water in the indoor firefighting pipe had a positive impact on improving the installation and use of a pressure gauge in the indoor fire hydrant. Second, making it easier for the fire safety officer to inspect the fire suppression system had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This suggests that if it becomes easier for the apartment building’s stakeholder to conduct internal inspection or the firefighting facility manager to carry out inspection on the fire suppression system, it would have a positive effect on the installation of a pressure gauge in the indoor fire hydrant. Finally, ensuring reliability in fire suppression had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that if it becomes easier to identify pressurized water in the indoor firefighting pipe, for the fire safety officer to conduct internal inspection, or for the firefighting facility manager to carry out inspection in accordance with the fire suppression system’s internal inspection requirements, it would increase reliability in fire suppression, making it more necessary to install a pressure gauge in the indoor fire hydrant.
        4,300원
        25.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to enhance heat insulation effect and to decrease fire hazard by attaching aluminum foil to expanded polystyrene, which is mainly used for insulating materials, to have fire retardant. The result of the test confirmed that the insulating materials, expanded polystyrene of 10 kg/m3 and 14 kg/m3 of density attached aluminum foil on both sides, showed 12%, 14% of improved heat transfer coefficient respectively compared to existing expanded polystyrene of the same density. Besides, they met all the standards for the testing of heat release and gas hazard. On the other hand, the one made of general expanded polystyrene could not meet the standards of the heat release test and the gas hazard test.
        4,000원
        26.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study classified the study subjects as apartment residents and managers, and conducted the descriptive statistics of research questions related to the effectiveness of the lightweight partition walls and the evacuation space. This study also conducted T-test and Anova to find the different perceptions of the lightweight partition walls and the evacuation space, and the different perceptions of related laws according to the characteristics of the residents and managers. The findings and suggestions were as follows. Firstly, strengthening of the Senior Fire Safety Manager system to prevent the insolvency of fire safety management due to the affiliate. Secondly, implementing enhanced penalties in accordance with not implementing residents education, in order to prevent not smoothly delivering manager trained education to residents. Thirdly, adjusting hands-on training time according to the gender of the managers to supplement women’s relatively low perceptions of lightweight partition. Fourthly, mandating evacuation guidance stickers on the evacuation space for residents to remove obstacles in the evacuation space. Finally, establishing regular residents education system in order to improve the awareness of the related laws for residents residing over 16th floors.
        4,600원
        27.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this article is to search stakeholders' recognition related to Fire Construction Surveillance system; a client(order), fire fighting officer, supervision company, construction company, design company, other. The paper provides 4 important things. Firstly, a client(order) suggested the lowest recognition in the needs about the need of separation order, that of contract for any construction work limited registered companies, and that of standard price for engineering.. Secondly, the design company is lowest recognition in guidance and control participating in construction-design phase. Thirdly, the design company is lowest in adjustment about manpower-allocation according to allocation criteria of technical manpower. Fourthly, a client(order) and supervision company are relatively lower than other stakeholder in necessity on special education and training system for auditor in fire protection construction. Almost all related matters are related to more or less stakeholders' interest.
        4,200원
        28.
        2014.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to make sure what the stress causes of women's EMTs within the firehouse are, and is to suggest ideas (plans) that are possible to resolve this problem. The reasons are because of difficulties such as not only the overwork at one's tasks, the uncomfortable working environment and circumstances, women's pregnancy, but also shift work or the shift system. It's own ideas about the way to resolve these difficulties are as follows: a separate operation of first-aid department, environmental improvement within a fire house (fire station) via remodeling, activation of substitute man power, alterating women's EMT services into daywork system, mutual encouragement and solicitude among co-workers, reinforcement of the number of the working force to be mobilized, and adoption about the rest year system in employment.
        4,000원
        29.
        2014.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is to search cooperation plan about fire investigation based on the public-private partnership. Especially focused on the partnership with 4 sector; the academic world, insurance sector, industrial world, professionalist of private fire investigation. In conclusion, Firstly a partnership with the academic world should have courses or school subject extensions related to fire investigation. Secondly, a partnership with insurance sector should secure trust through unifying estimate standard about the origin of damage. Thirdly, A partnership with industrial company is presented making collaboration team to investigate the fire investigation. Lastly, the partnership with the private professionalist related to fire investigation should strengthen credibility and expertise.
        4,000원
        30.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The rate that women's EMTs(emergency medical technicians) in fire department occupy is increasing, but my general plan is aimed at suggesting the improving plan for the working environment of women's EMTs paying attention to the duty stresses of increasing women's EMTs, because improvement for the working environment of women's EMTs is being proceeded slowly. I suggested my improving plan for solving the working stress on the basis of a survey of the Recognition against women's EMTs as follows. Firstly, I suggested that physical strength of women's EMTs should be managed well continually via program establishment and a defined evaluation not only by employing a professional person in charge for physical strength in firehouse, but also by replenishing the suitable number for the urgent mobilization. Secondly, I suggested that the suitable number for the urgent mobilization should be increased to 3 including an ambulance driver. Thirdly, I suggested necessity such as the fruitful education and the creation of circumstances that can focus on education for improving participation rate, development of various new educational program, incentive program and penalty. finally, I suggested the fact that is related to the actual re-amendment of the concerned law and ordinance such as not only the smooth treatment of penalty for a traffic signal violation of ambulance and the legal remedy system due to aggravation of a patient's condition during a first-aid course, but also workshop and meeting among the periodical EMTs and administration of special therapy program and sufficient recess.
        4,000원
        1 2