        1.
        2023.05 구독 인증기관·개인회원 무료
        Corrosion-related challenges remain a significant research topic in developing next-generation Molten Salt Reactors (MSRs). To gain a deeper understanding of preventing corrosion in MSRs, previous studies have attempted to improve the corrosion resistance of structural alloys by coating surfaces such as alumina coating. To conduct a corrosion test of coating alloys fully immersed in molten salt, it’s important to ensure that the coating application process is carefully carried out. Ideally, coating all sides of the alloy is necessary to avoid gaps like corners of the alloy, while only applying a one-sided coating alloy can lead to galvanic corrosion with the base metals. Using the droplet shape of eutectic salt applied to only one side of the coating alloy would avoid these problems in conventional corrosion immersion tests, as corrosion would occur solely on the coating surface. Although the droplet method for corrosion tests cannot fully replicate corrosion in the MSRs environment, it offers a valuable tool for comparing and evaluating the corrosion resistance of different coating surfaces of alloys. However, the surface area is important due to the effect of diffusion in the corrosion of alloy in molten salt environments, but it is difficult to unify in the case of droplet tests. Therefore, understanding the droplet-alloy properties and corrosion mechanism is needed to accurately predict and analyze these test systems’ behavior highlighting unity for corrosion tests of different coating surfaces of alloys. To analyze the molten salt droplet behavior on various samples, pelletized eutectic NaCl-MgCl2 was prepared as salt and W-, Mo-coating, and base SS316 as samples. At room temperature, the same mass of pelletized eutectic NaCl-MgCl2 was placed on different samples under an argon atmosphere and heated to a eutectic point of 500°C in a furnace. After every hour, the molten droplets were hardened by rapid cooling at room temperature outside the furnace. The mass loss of salts and the contact area of the samples were measured by mass balance and SEM. The shape, surface area to volume ratio, and evaporation of the droplets of NaCl-MgCl2 per each coating sample and hour were analyzed to identify the optimal mass to equalize the contact coating surface of alloys with salts. Furthermore, We also analyzed whether their results reached saturation of corrosion products through ICP-MS. This will be significant research for the uniformity of the liquid-drop shape corrosion test of the coating sample in molten eutectic salts.
        2.
        2023.05 구독 인증기관·개인회원 무료
        Molten salt reactors have several advantages over conventional light water reactors. These include producing less nuclear waste, operating at higher power efficiency and inherent safety due to the low operating pressure. NaCl-MgCl2 eutectic salt is one of the candidates for the molten salt reactor coolant. However, because the salt is very hygroscopic, structural material corrosion occurs resulting in the high cost to maintain. To mitigate corrosion there have been many studies for the dehydration of the salt, especially focusing on the magnesium chloride. The reason is that the moisture adsorbed to the magnesium chloride undergoes hydrolysis over 200 degrees Celsius and decomposes to MgOHCl while the moisture associated with the NaCl is easily liberated during the heating procedure without chemical reaction. As the operating temperature of the molten salt is between 500 and 700 degrees Celsius, the MgOHCl is believed as the main cause for the structural corrosion. In this research, thermal dehydration of the salt with elemental Mg, for the NaCl-MgCl2 eutectic, was studied based on the previous dehydration methods and considering scalable and easy to handle. The MgOHCl was removed both through the thermal decomposition and the reduction by Mg metal. After the removal of MgOHCl, based on the difference between the freezing points and the density, the salt cooled down very slowly to ensure the separation between the purified salt and the disposals such as MgO and remaining Mg metals. The efficiency of the dehydration method was determined by the concentration of the MgOHCl. The concentration was determined by cyclic voltammetry and the result was compared with undehydrated salt and salt dehydrated thermally without the addition of Mg metal. To qualify and quantify the MgOHCl content through the cyclic voltammetry, it was necessary to observe the signal by adding MgOHCl to each sample. Based on the thermogravimetric analysis result of MgCl2· 6H2O, MgOHCl powder was formed through heating the MgCl2·6H2O.
        3.
        2022.10 구독 인증기관·개인회원 무료
        Molten salts based on magnesium chloride can be used in the nuclear power reactor because they have a high heat capacity and heat stability, and allow for a faster neutron spectrum. However, magnesium chloride is highly hygroscopic, leading to the formation of moisture-related impurities, which result in the corrosion of structural materials and negatively affect the operation of the reactor. The dehydration of magnesium chloride is studied using both thermal and electrochemical treatments. According to previous studies, water impurities in magnesium chloride molten salt transform into magnesium oxide over 650 degrees Celsius. The temperature profile of the molten salt is suggested to separate magnesium chloride and magnesium oxide, focusing on cooling rate near the freezing point of magnesium chloride. Two layers separated by a phase boundary on the salt surface appear due to the density difference between magnesium oxide and magnesium chloride. Further, the removal of oxide ions remaining in the molten salt is carried out by electrochemical treatment. Two different cells, each consisting of two electrodes, are used. One cell is composed of graphite anode and nickel cathode. The other is composed of tin oxide anode and nickel cathode. As the reaction proceeds, carbon dioxide and oxygen are generated in graphite and tin oxide, respectively, and magnesium electrodeposition occurs at the cathode. The amount of purified magnesium oxide is measured to the endpoint, which is notified by the reduced current. The efficiency of each method is compared by measuring the weight ratio of the purified part to the unpurified part. Thermogravimetric analyzer (TGA) and UV-vis spectroscopy are used to check the quality of the purified part. Only magnesium oxide remains at a temperature above the boiling point of magnesium chloride. Therefore, the amount of magnesium oxide in the purified part can be measured by the mass change of the salt through the TGA method. For UV-vis spectroscopy, the transmittance is measured which depends on the weight percent of the impurities in the purified part. The suggested purification method using both thermal and electrochemical treatment is assessed quantitatively and qualitatively. It is expected that hygroscopic molten salts other than magnesium chloride will be able to be dehydrated through the above process.
        4.
        2022.10 구독 인증기관·개인회원 무료
        Molten chloride salts are promising candidates as a coolant for Molten Salt Reactors (MSRs) because of their low cost, high specific heat transfer, and thermal energy storage capacity. The NaCl- MgCl2 eutectic salts have enormous latent heat (430 kJ/kg) and financial advantage over other types of molten chloride salt. Despite the promise of the NaCl-MgCl2 eutectic salt, problems associated with structural material corrosion in the MSR system remain. The hygroscopicity of NaCl-MgCl2 and high MSRs operating temperature accelerate corrosion within structural alloys. Especially, MgCl2 reacts with H2O in the eutectic salt to produce HCl and Cl2, which are known to further exacerbate corrosion by the chlorination of structural materials. Therefore, several studies have worked to purify impurities associated with MgCl2, such as H2O. Thermal salt purification of NaCl-MgCl2 eutectic salt is one method that reduces HCl and Cl2 gas generation. However, MgO and MgOHCl are generated as the byproduct of thermal purification through a reaction between MgCl2 and H2O. The corrosion behavior of MgO within structural alloys after thermal treatment is not well known. This paper demonstrates corrosion behavior within structural alloy after thermal treatment at various temperature profiles of the NaCl-MgCl2 eutectic salt. According to the temperature range, MgCl2·H2O are separated at 100~200°C, and MgOHCl and HCl begin to occur at 240°C or higher. Finally, MgOHCl produces MgO and HCl at 500°C or higher temperatures. After thermal treatments, the H2O, MgOHCl, and MgO content were measured by Thermo Gravimetric Analyzer (TGA) to evaluate significant products causing corrosion. The structural materials were analyzed by the Scanning Electron Microscope-Energy Dispersive Spectroscopy (SEM-EDS) and using the mass change method to observe the type of localized corrosion, the corrosion rate, and the corrosion layer thickness. This study is possible in that it can reduce economic costs by reducing the essential use of expensive, high-purity molten salts because it is related to a substantial financial cost problem considering the amount of molten salt used in industrial sites.
        5.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the fate and removal of 15 pharmaceuticals (including stimulants, non-steroidal anti-inflammatory drugs, antibiotics, etc.) in unit processes of a sewage treatment plant (STP) were investigated. Mass loads of pharmaceuticals were 2,598 g/d in the influent, 2,745 g/d in the primary effluent, 143 g/d in the secondary effluent, and 134 g/d in the effluent. The mass loads were reduced by 95% in the biological treatment process, but total phosphorous treatment did not show a significant effect on the removal of most pharmaceuticals. Also, mass balance analysis was performed to evaluate removal characteristics of pharmaceuticals in the biological treatment process. Acetaminophen, caffeine, acetylsalicylic acid, cefradine, and naproxen were efficiently removed in the biological treatment process mainly due to biodegradation. Removal efficiencies of gemfibrozil, ofloxacin, and ciprofloxacin were not high, but their removal was related to sorption onto sludge. This study provides useful information on understanding removal characteristics of pharmaceuticals in unit processes in the STP.
        4,200원
        6.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목적 : 실리콘 하이드로겔렌즈의 베이스커브가 피팅상태와 착용감에 미치는 영향을 평가하고자 하였다. 방법 : 안질환이 없고 콘택트렌즈 착용에 문제가 없는 성인 30명(60안, 평균 나이: 21.9±1.5세)를 대상으로 하였다. 두 종류의 베이스커브(8.5 mm와 9.0 mm)를 가진 실리콘 하이드로겔렌즈를 사용하여 경험적 피팅법은 각막의 약주경선의 곡률반경이 7.8 mm보다 스티프하면 8.5 mm 베이스커브로, 7.8 mm보다 플랫하면 9.0 mm 베이스커브로 결정하였고, 시험렌즈 피팅법은 두 개 베이스커브의 콘택트렌즈를 이중맹검법으로 모두 착용 시킨 후 평가하였다. 콘택트렌즈 착용 후 피팅상태는 렌즈의 중심잡기, 순목 시 렌즈움직임, 래그(lag), 푸쉬업검사(push-up test), 케라토미터 마이어상 관찰 결과로 평가하였고, 자각적 착용감은 Likert 5점 척도 설문 조사를 통해 평가하였다. 결과 : 경험적 피팅법의 경우 전체 대상안의 91.67%에서 적합한 피팅상태를 보였으나, 시험렌즈 피팅법을 통해 두 가지 베이스커브의 피팅상태를 비교하면 스티프한 각막에 9.0 mm 베이스커브가 이상적인 경우가 33.33%, 플랫 한 각막에 8.5 mm 베이스커브가 이상적인 경우도 25%로 나타나, 경험적 피팅법을 통해 이상적인 성공률은 71.67% 을 나타냈고, 시험렌즈 피팅법은 100%의 성공률을 보였다. 베이스커브 별 착용감은 대상자의 63.33%가 베이스커 브에 따라 착용감에 차이를 느끼지 않았지만 8.5 mm에서 3.53점, 9.0 mm에서 2.75점으로 8.5 mm 베이스커브 에 대한 만족도가 유의하게 높았고(t=4.528, p<0.001), 플랫 각막군의 27.78%가 8.5 mm 베이스커브에 만족하는 것으로 나타났다. 결론 : 실리콘 하이드로겔렌즈의 베이스커브 선택에 있어서 각막의 곡률반경만을 고려한 경험적 피팅을 하거나 착용자 착용감에만 의존할 경우 부적합한 상태가 나타날 수 있으므로 시험렌즈 피팅을 통한 피팅상태 평가가 중요할 것으로 사료된다.
        4,200원
        7.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Total organic carbon(TOC) was introduced as the water quality index of the rivers and lakes in 2013. This paper evaluated factors affecting effluent TOC concentrations and treated and discharged loads of existing publicly owned treatment works(POTWs). For selected POTWs with greater treatment capacity than 500㎥/day, factorial analysis was used to consider effects of kinds of biological treatment processes, inflow of other types of wastewater(industrial, livestock, landfill leachate wastewater, etc.) with domestic wastewater, sewer separation rate, and effluent discharging zones in which different effluent criteria applied. As a result, those factors did not show significant effect on effluent TOC concentration of POTWs in effluent discharging zone Ⅰ and Ⅱ. However, In effluent discharging zone Ⅲ and Ⅳ, kinds of biological treatment processes, the inclusion of other waste in influent of domestic wastewater, and the sewer separation rate were significant factors. The treated TOC load in POTWs was also not affected significantly by the variables set in this study. On the other hand, those three factors influenced significantly on the TOC load discharged to water bodies. The sum of factorial effects and the contribution rate of three factors to the discharged TOC load was 60.23 and 41%, 59.57 and 41%, and 42.04 and 18%, respectively.
        4,000원
        8.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The aim of this study was to evaluate pretreatment methods for 27 pharmaceuticals and personal care products (PPCPs) in various sewage samples using a modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) and online solid-phase extraction with LC-MS/MS. Extraction efficiencies of PPCPs in the solid phase under different experimental conditions were evaluated, showing that the highest recoveries were obtained with the addition of sodium sulfate and ethylenediaminetetraacetic acid disodium salt dehydrate in acidified conditions. The recoveries of target compounds ranged from 91 to 117.2% for liquid samples and from 61.3 to 137.2% for solid samples, with a good precision. The methods under development were applied to sewage samples collected in two sewage treatment plants (STPs) to determine PPCPs in liquid and solid phases. Out of 27 PPCPs, more than 19 compounds were detected in liquid samples (i.e., influent and effluent) of two STPs, with concentration ranges of LOQ-33,152 ng/L in influents and LOQ-4,523 ng/L in effluents, respectively. In addition, some PPCPs such as acetylsalicylic acid, ibuprofen, and ofloxacin were detected at high concentrations in activated sludge as well as in excess sludge. This methodology was successfully applied to sewage samples for the determination of the target compounds in STPs.
        4,600원
        9.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Total organic carbon (TOC) will replace chemical oxygen demand (CODMn) as an effluent water quality standard in public sewage treatment works (PSTWs) from 2021 in Korea. To ensure effective control of TOC in the effluent, investigation was carried out into TOC levels and sewage treatment operation factors in five target PSTWs using anaerobic-anoxic-aerobic (A2O) processes, media, membrane, and sequencing batch reactor (SBR) technologies. TOC removal efficiencies appeared to be 93-96% on average. As a fraction of TOC, biodegradable dissolved organic carbon (BDOC) was reduced from 64% in the influent to 9% in the effluent in these PSTWs. During the investigation, biological treatment processes were applied flexibly for operation factors such as HRT, SRT, MLSS, F/M ratios and BOD volume loads, based on the influent characteristics and design conditions. As a result, we suggest efficient operating conditions in PSTWs by evaluating relationships between TOC removal and operation factors.
        4,900원
        10.
        2018.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As the issue of microplastics (MPs) detection in tap water was raised in other countries in 2017, monitoring of MPs in drinking and source water, and sewage treatment plant (STP) effluents was initiated. This study intends to look into other studies on MPs in STPs at home and abroad, and review the characteristics of MPs and their removal efficiencies in the STPs, the risk and effect of MPs on watersheds, and management practices in order to help better understand MPs in STPs. To manage MPs effectively in STPs, it is necessary to investigate the detection of MPs discharged from STPs, do research on human health risk and control measures, and build a monitoring system including standardized analytical methods.
        4,300원
        11.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As the modern society is rapidly developing and people become affluent in materials, many new chemical compounds in different forms of products (e.g., antibiotics, pesticides, detergents, personal care products and plastic goods) are produced, used, and disposed of to the environments. Some of them are persistently having a harmful impact on the environment and mimicking endocrine properties; in general they are present in the environment at low concentrations, so they are called organic pollutants. These organic micropollutants flow to sewage treatment plants via different routes. In this study, the generation characteristics, exposure pathways, detection levels, and environmental impacts of organic micropollutants were critically reviewed. In addition, currently available risk assessment methods and management systems for the compounds were reviewed. The United States Environmental Protection Agency (US EPA), for example, has monitored organic micropollutants and set the monitoring and management of some of the compounds as a priority. To effectively manage organic micropollutants in sewer systems, therefore, we should first monitor organic micropollutants of potential concern and then make a watch list of specific substances systematically, as described in guidelines on listing water pollutants in industrial wastewater.
        4,000원
        15.
        2018.12 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        A Fabry-Perot interferometer (FPI) for mesospheric observations was installed at King Sejong Station (62.2°S, 58.9°W) in Antarctica in 2017. For the initial validation of the FPI measurements, we compare neutral wind data recorded with the FPI with those from a Meteor Radar (MR) located nearby. The overall characteristics of the FPI and MR winds of both OH 892.0 nm (87 km) and OI 557.7 nm (97 km) airglow layers are similar. The FPI winds of both layers generally match the MR winds well on the observed days, with a few exceptions. The correlation analysis of the FPI and MR wind data shows that the correlation coefficients for the zonal winds at 87 and 97 km are 0.28 and 0.54, respectively, and those for the meridional winds are 0.36 and 0.54, respectively. Based on the assumption that the distribution of the airglow emissions has a Gaussian function with respect to the altitude, we calculated the weighted mean winds from the MR wind profile and compared them with the FPI winds. By adjusting the peak height and full width at half maximum of the Gaussian function, we determined the change of the correlation between the two winds. The best correlation for the OH and OI airglow layers was obtained at a peak height of 88–89 km and 97–98 km, respectively.
        16.
        2013.02 KCI 등재 서비스 종료(열람 제한)
        본 연구는 최근 자동노출제어장치에 의한 X선질 보정 및 다양한 수학적 보정 알고리즘 적용이 가능한 전산화단층촬영 장치를 이용하여 견부 강제 견인용 밴드의 사용 유‧무에 따라 영상의 질과 환자의 편의성 및 안정성 측면에서 견부강제 견인법에 대한 임상적 유용성을 제시하고자 하였다. 이를 위하여 경부 통증을 호소하는 환자 79명을 대상으로 견부 강제 견인용 밴드를 사용하기 전‧후의 측면 투영 scout 영상과 횡단면 영상을 획득하여 횡단면 영상의 일정 크기의관심영역 내의 화소 및 평균 HU 값을 비교하여 정량적 분석을 하였고 인공물과 해상도 및 분해능에 대한 임상 영상평가를 정성적으로 분석하였으며 환자가 느끼는 불편 정도를 자가 진단 설문 평가하였다. 결과적으로 측면 투영 scout영상에서 견부 강제 견인용 밴드를 사용한 경우 묘출되는 경추의 수가 증가되었으나 횡단면 영상의 관심영역 내에서견부 강제 견인용 밴드를 사용하기 전‧후에 대한 화소 및 평균 HU 값의 변화는 거의 없는 것으로 판단되었으며 인공물과 해상도 및 대조도와 관련된 정성적 분석 결과에서 관찰자간 특이한 결과는 보이지 않았다. 따라서 견부 강제 견인용 밴드의 사용에 대한 자가 진단 설문 평가에서 환자의 82.27%는 불편함을 호소하였으며 정량적 및 정성적으로 영상의 질을 분석한 결과에서 사용에 따른 영상의학적 이점은 없는 것으로 판단되었다. 최근 다양한 수학적 보정 알고리즘에 의한 전처리 필터 과정의 적용과 더불어 절편 두께의 감소 및 자동노출제어장치 등에 의한 선질 보정 등이 가능한전산화단층촬영 장치가 보급되면서 선속 경화에 의한 영상의 잡음은 문제가 되지 않을 것으로 판단되어 영상의 질에영향을 주지 않으면서 환자에게 불편함을 주거나 추가적 위험성이 있는 견부 강제 견인용 밴드의 사용은 더 이상 임상적 유용성이 없는 것으로 판단되었다.