        21.
        2018.04 서비스 종료(열람 제한)
        In this paper, the mechanical properties of hardened concrete were evaluated by using electric arc furnace oxidizing slag(EOS) aggregate. Water-Cement(W/C) ratio was selected as 0.45 and 0.30, and the mixing amount of EOS aggregate as 0%, 50%, 100%. Experiments were carried out to compare the unit volume weights by concrete mixing, and the compressive strength test was carried out at 28 days of age. The unit volume weight and compressive strength of the EOS aggregate increased as the amount of the mixture increased. It also shows the difference according to the W/C ratio.
        22.
        2017.09 서비스 종료(열람 제한)
        This study investigated the properties of lightweight foamed concrete by using surfactant and synthetic foaming agent, lightweight aggregate. The effects of foaming agent types and replacing ratio of lightweight aggregate on the compressive strength, density and pore structure of the concrete were investigated. This study showed the improvement of important properties of lightweight foamed concrete. Lower pore distribution and correspondingly higher compressive strength values were reached. Also, synthetic foaming agent had more positive effect on the strength of foamed concrete.
        23.
        2017.05 서비스 종료(열람 제한)
        부분 침지형 수직류식 인공습지공정은 20×12×20cm 크기로 제작하였으며 반응조 총 용적은 4.8L(유효용적 4.3L)이다. 인공습지 충진 여재는 생초액비 폐잔류물과 황토 및 점토를 혼합하여 지름 5~10mm의 크기로 제조한 황토볼을 사용하였으며, 반응조 하부로부터 높이 13.5cm(유효용적 대비 75%)까지 황토볼을 충진 하였다. 그리고 그 위에 모래를 반응조 높이 20cm 까지 충진 하였다. 모래는 지하흐름형 수직류식 인공습지공정의 식물 식재 및 뿌리의 기공확보를 위하여 사용 하였으며, 식물로 갈대를 반응조내 식재 가능한 만큼 충분히 식재하였다. 본 연구에서는 수직류식 반응조 단일공정에서 Oxic, Anoxic 공정이 존재하도록 Zone을 구분한 상태에서 tidal flow 방식으로 운전하였다. 체류시간은 96hr로 운전을 실시하였으며, 침지율 25% 지점에서 반송을 실시하였으며, 반송률은 1Q, 2Q, 4Q로 변화시켜가며 반송률에 따른 유기물 및 영양염류 제거효율을 살펴보았다. 처리수는 pH, SS, CODMn, T-N, T-P를 분석하였으며, 유입수의 평균농도는 pH 6.6~6.8, SS 7.0mg/L, COD 44.22mg/L, T-N 35.81mg/L, T-P 0.67mg/L 이었다. 그 결과 pH는 반송률에 관계없이 6~8사이로 유지되는 것으로 나타났으며, SS는 모든 반송률 조건에서 유입수 유입시 모래층을 거쳐 반응조 내부로 유입되기 때문에 부유물질이 거의 없는 수준까지 제거되는 것으로 나타났다. COD는 반송률 1Q 보다는 2Q 이상으로 운전할 때 COD 제거에 있어 더 좋은 것으로 나타났으며, T-N은 반송률 2Q 이상의 조건에서 T-N 농도가 약 4~5mg/L 수준까지 감소하여 그 농도수준으로 계속 유지되는 것으로 나타났다. 따라서 반송률은 2Q 이상으로 반송을 실시하여야 COD 및 T-N의 제거효율이 더 증가되는 것으로 나타났으며, 반송률 2Q에서는 제거효율이 COD 70%, T-N 87%, 4Q에서는 COD 73%, T-N 89%로 나타나 2Q 이상의 반송률에서는 반송률 증가에 따른 처리효율 변화가 미미한 것으로 나타났다. T-P는 반송률에 관계 없이 매우 낮은 농도로 유출되어 반송률별 처리효율 비교가 큰 의미를 가지지 않는 것으로 나타났다. 하지만 반송률을 2Q 이상으로 실시할 경우 1Q의 반송률 보단 T-P가 좀 더 제거되는 것으로 나타났다. 따라서 2Q 이상의 반송률에서는 반송률 증가에 따른 COD, T-N 처리효율 변화가 미미하여 경제성 등을 고려할 때 최적 반송률은 2Q인 것으로 판단된다. 부분 침지형 수직류식 인공습지공정 최적 반송률(2Q) 조건에서 처리수의 유기물 및 영양염류 농도는 SS 5.1mg/L, COD 14.6mg/L, T-N 4.71mg/L, T-P 0.32mg/L로 나타났다. 이는 하수도법 시행규칙 공공하수처리시설 방류수수질기준(1일 하수처리용량 500㎥ 미만 50㎥ 이상) SS 10mg/L, COD 40mg/L, T-N 20mg/L, T-P 2mg/L 농도에도 만족하는 것으로 나타났다.
        24.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        형상비(M/VD, shear span-depth ratio)가 4.5인 축소모형의 원형기둥 실험체 3개를 제작하였다. 철근콘크리트 기둥 실험체의 단면 은 원형이고 중공단면으로 제작되었다. 철근콘크리트 기둥 실험체의 단면 지름은 400 mm, 중공 지름은 200 mm이다. 일정한 축력 하에서 반복 하중을 가력하는 준정적 실험을 수행하였다. 실험체의 주요변수는 횡방향철근비이다. 모든 실험체의 횡방향 나선철근 체적비는 소성힌지 구 간에서 0.302~0.604%의 값을 갖는다. 이 값은 도로교설계기준에서 요구하는 최소 심부구속철근 요구량의 45.9~91.8%에 해당하며, 이는 내진 설계가 되지 않은 기존 교각이나 내진설계개념으로 설계되는 교각을 나타낸다. 본 연구의 최종목적은 실험적 기초자료의 제공과 함께 성능단 계별 균열거동, 하중-변위 이력곡선, 에너지 소산 능력, 등가점성감쇠비, 잔류변형, 유효강성 등 내진성능의 정량적 수치와 경향을 제공하기 위 한 것이다. 본 논문에서는 실험결과를 통해 분석된 실험변수에 따른 실험결과들을 공칭강도, 비선형 모멘트-곡률 해석 결과, AASHTO LRFD 및 도로교설계기준(한계상태설계법)과 같은 기준들과 비교하였다.
        25.
        2016.04 서비스 종료(열람 제한)
        This paper presents an experimental study on the improvement of ductile and flexural strength for high performance fiber reinforced cementitous composites (HPFRCC). The test was evaluated by compressive and flexural behavior of HPFRCC(compressive strength : 180 MPa) according to aspect ratio and volume contents of steel fiber. The flexural strength was increased by aspect ratio near 100 or increasing volume contents of steel fiber while there is no clearly result on the compressive strength.
        26.
        2016.04 서비스 종료(열람 제한)
        This study evaluates the material performance of slump value and compressive strength of the concrete which was made by recycled sand and blast furnace slag powder(BFSP). The main variables are replacement ratio of BFSP. As a result, it was evaluated that more detailed evaluation is needed in long-term strength development and the compensation of slump value to the replacement ratio of BFSP.
        27.
        2014.10 서비스 종료(열람 제한)
        In this study, four reinforced concrete beams, replacing recycled coarse aggregate with PVA fiber(BSPG-R series), were constructed and tested under monotonic loading. Experimental programs were carried out to improve and evaluate the structural performance of such test specimens, such as the load-displacement, the failure mode and the maximum load carrying capacity. all the specimens were modeled in 1/2 scale-down size.
        28.
        2013.10 서비스 종료(열람 제한)
        This paper provides Shear Performance Evaluation of Squat Shear Wall on Aspect Ratio of Slit. The main variables of paper were vertical slit and slit length. Slit height analysis results by lengthening the slit height was reduced according to the strength and stiffness, the maximum displacement was increased.
        29.
        2013.10 서비스 종료(열람 제한)
        Usually, columns are the key load bearing elements in concrete frame structures. They are typically weak, not to long distance explosive loadings, but to short distance loadings. In this study, the effect of blast loadings occurring within a short distance was examined analytically. Various aspect ratios of column sections with the same sectional area and reinforcement ratio were considered as variables in order to evaluate damage levels. It was found that ratio of residual strength to nominal axial strength of columns decreased as contact area of column to the blast loading became smaller.
        30.
        2013.04 서비스 종료(열람 제한)
        This research is a part of a research program to verify the seismic performance of circular reinforced concrete bridge columns with respect to longitudinal steel ratio and transverse steel ratio under cyclic lateral load. In this paper, describes mainly displacement ductility of circular reinforced concrete bridge columns with respect to test variables.
        31.
        2012.05 서비스 종료(열람 제한)
        This paper experimentally evaluates effects of fiber ratio of the seismic performance of infill walls. Variable of study was a concrete and fiber ratio (PVA1.3+PE0.2 and PVA0.75+PE0.75). The experimental investigation consisted of cyclic loading tests on 1/3-scale models of infill walls. The experimental results show that SHCC specimens was more ductile behavior.
        32.
        2009.06 KCI 등재 서비스 종료(열람 제한)
        The effects of the cation-to-anion resin ratio and bed depth on ion exchange performance of mixed-bed were studied at ultralow solution concentration. Breakthrough curves were experimentally obtained for NaCl solution as functions of resin ratio and bed depth. The bed depth affects the pattern of the sodium breakthrough curve but not the chloride breakthrough curve in beds because of the selectivity difference. Resin selectivity determines the shape of breakthrough curves. Some sodium and chloride breakthrough curves crossed at a point as a function of resin ratio. The lower cation-to-anion resin ratio showed the higher effluent concentration or treated volume of the crossover point regardless of the total resin weight.