검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 215

        41.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        UHPC(Ultra High Performance Concrete) is used widely with its remarkable performance, such as strength, ductility and durability. Since the fibers in the UHPC can control the tensile crack, the punching shear capacity of UHPC is higher than that of the conventional concrete. In this paper, seven slabs with different thickness and fiber volume ratio were tested. The ultimate punching shear strength was increased with the fiber volume ratio up to 1%. The shear capacity of specimens with the fiber content 1% and 1.5% do not have big differences. The thicker slab has higher punching shear strength and lower deformation capacity. The critical sections of punching shear failure were similar regardless of the fiber volume ratio, but it were larger in thicker slab.
        4,000원
        42.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Ultra High Performance Fiber Reinforced Concrete (UHPFRC) has a outstanding tensile hardening behaviour after a crack develops, which gives ductility to structures. Existing shear strength model for fiber reinforced concrete is entirely based on crack opening behavior(mode I) which comes from flexural-shear failure, not considering shear-slip behavior(mode II). To find out the mode I and mode II behavior on a crack in UHPFRC simultaneously, maximum shear strength of cracked UHPFRC is investigated from twenty-four push-off test results. The shear stress on a crack is derived as variable of initial crack width and fiber volume ratio. Test results show that shear slippage is proportional to crack opening, which leads to relationship between shear transfer strength and crack width. Based on the test results a hypothesis is proposed for the physical mechanics of shear transfer in UHPFRC by tensile hardening behavior in stead of aggregate interlocking in reinforced concrete. Shear transfer strength based on tensile hardening behavior in UHPFRC is suggested and this suggestion was verified by comparing direct tensile test results and push-off test results.
        4,000원
        43.
        2015.04 구독 인증기관 무료, 개인회원 유료
        In constructing the cast-in-place concrete track system, the installation of reinforcing bars to a TCL is one of the main causes of consuming construction time. In this study, to eliminate the reinforcing bar installation process, the applicability of the fiber reinforced concrete to the TCL is studied using the numerical analysis. The analysis is performed using the commercial finite element program, ABAQUS, and, in the analysis, the effect of the variations in fiber content rate and the surrounding temperature is considered. From the analysis, it is found that the fiber reinforced concrete has better applicability than the existing reinforced concrete with steel bar.
        3,000원
        44.
        2015.04 구독 인증기관·개인회원 무료
        This paper deals with the strengthening effect of reinforced concrete beams strengthened with carbon fiber sheets (CFSs). Fifteen strengthened reinforced concrete (RC) beams were experimentally evaluated to determine improvements in structural performance. Test parameters in this experimental study are strengthening ratios and strengthening methods of CFSs (I-S, I-W, U-S, U-W type). RC beams strengthened with CFSs were tested under sustaining load. Considering strengthening ratios and strengthening methods of carbon fiber sheets, structural performance and failure mode of test specimens were evaluated. The results show that maximum capacity of beams strengthened with CFSs is about 28.8% in I-S type, 20.5% in I-W type, 26.0% in U-S type, 28.7% in U-W type higher than that of control beam.
        45.
        2013.09 구독 인증기관 무료, 개인회원 유료
        Ultra high performance concrete which has recently been studied was developed to complement the brittle behaviour and dynamic uppermost limit of high strength concrete. Fiber reinforced concrete which mixed steel fiber is receiving attention as an alternative about this and is being developed to complement the disadvantages of high strength concrete including lower toughness coefficients and crack resistance and spalling in fires. Review about fiber reinforced ultra high strength concrete that this study tries to treat includes reduction of self shrinkage generated by high cement content per unit volume of concrete, evaluation of compression and tension strength to lower internal and external spalling resistance and fragility factors of member of framework, and flow characteristics of concrete which doesn't harden according to steel fiber amounts and used materials. As the result, the more fiber reinforcement increases, the more compression and tensile strength increase and deformation control of cement matrix and improvement of energy absorption ability showed the great effect in shrinkage reduction.
        4,000원
        46.
        2013.04 구독 인증기관·개인회원 무료
        휨 거동 및 전단부의 전단거동으로 인한 철근상세 및 사용되어지는 철근의 과다로 인하여 취성파괴의 양상이 발생 하고 있다. 이에 본 실험에서는 유리섬유망을 이용하여 철근과의 휨 및 변위 거동을 통하여 무보강철근과 유리섬유망의 ply 수에 따른 휨거동 실험을 통하여 균열을 살펴보고서 향후 휨 거동에 적정한 유리섬유망의 철근의 배치겹수에 대한 사용량을 검토하고자 한다.
        47.
        2013.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: As pavement generally provides service shorter than an expected life cycle, maintenance cost increases gradually. In order to help extending the service life and reduce maintenance cost, a new multi-functional composite pavement system is being developed in Korea. METHODS: This study is a part to develop the multi-functional composite pavement and is to investigate the mechanical performances of fiber-reinforced lean concrete for pavement subbase. The inherent problem of fiber reinforced concrete is dispersion of fibers in concrete mix. This study additionally evaluated fiber dispersion characteristics with respect to different fiber types. RESULTS: From the test results, the compressive strengths of the concretes satisfied the required limit of 5MPa at 7days. The standard deviation of the measured number of fibers were lower in the order of nylon, steel fiber and polypropylene. CONCLUSIONS: Reject ash was shown to be satisfactory as a replacement material to Portland cement in lean concrete base. The fiber volume fraction is suggested to be 0.4% even though the fracture toughness did not vary significantly with respect to fiber types. However, fracture energy absorbed up to complete failure increased with the increased fiber volume fraction increment.
        4,200원
        48.
        2012.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: This study is to investigate the mechanical performance of the fiber reinforced lean concrete with respect to different types of fibers. METHODS: Increased vehicle weight and other causes from the exposed conditions have accelerated the deteriorations of road pavement. A new multi-functional composite pavement system is being developed recently in order to extend service life and upgrade the pavement. A variety of tests were conducted before and after hardening of the concrete. RESULTS: From the test results, it was found that the use of different types of fibers did not affect the compressive strength development. This might be due to the inherent property of the lean concrete. When steel fibers were used relatively greater flexural strength and flexural fracture toughness were developed. Also addition of fly ash by replacing a part of Portland cement the fracture toughness was slightly increased. CONCLUSIONS: It has been known that the addition of fibers and use of mineral admixture can be positively considered in the development of multi-functional composite pavement system as its required mechanical performance is obtained.
        4,000원
        50.
        2012.04 구독 인증기관·개인회원 무료
        Recently, strengthening and repairing concrete structures are increasing due to the deterioration of concrete infrastructures. Carbon Fiber Reinforced Polymer Plastic (CFRP) system for strengthening concrete structures have emerged as an alternative to traditional strengthening techniques, such as steel plate bonding, section enlargement, and external post-tensioning. CFRP systems offer advantages over traditional strengthening techniques such as lightweight, noncorrosive, and relatively easy to install. In this paper, we present the structural design algorithm for the RC beams strengthened with CFRP sheet based on ACI 440. In addition, structural behavior of strengthened RC beams is investigated by varying the amount of CFRP sheets.
        52.
        2011.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        섬유보강 콘크리트를 이용하여 도로 포장의 기층을 형성하고 그 위에 아스팔트 또는 콘크리트로 표층을 구성함으로써 기능적인 측면과 구조적인 측면 모두에서 우수한 공용성을 발휘할 수 있는 복합포장 공법을 개발하기 위한 기초 연구로써 본 연구에서는 섬유보강 콘크리트 기층이 환경하중을 받을 때의 거동을 수치 해석을 통해 중점적으로 분석하였다. 이를 위해 2차원 유한요소해석 모델을 개발하였으며 이러한 모델을 사용하여 기층 슬래브 두께, 열팽창계수, 탄성계수, 인장 및 압축강도 등의 변수에 대하여 민감도 분석을 수행하였다. 기층의 거동으로는 균열간격과 균열틈 등 균열 특성을 선정하였다. 수치 해석 결과 고려한 변수가 균열간격 및 균열틈에 미치는 일반적인 영향을 파악할 수 있었으며, 기층 거동에 민감한 영향을 미치는 인자를 선정할 수 있었다. 이러한 결과는 표층 재료와 적절히 조합될 수 있는 섬유보강 콘크리트 기층의 재료 특성을 결정하는 기반이 될 것이다.
        4,200원
        55.
        2010.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 콘크리트 포장의 균열, 스폴링 등의 파손문제를 해결하기 위해 국내 시공사례가 없는 이층 포설 공법의 도입 및 기술 경제적 타당성을 검토하고자 하였다. 본 포장공법중 하나인 강섬유 보강 콘크리트(SFRC, Steel Fiber Reinforced Concrete)의 포장 배합 적용성이 검토되었다. 강섬유 함량과 포장 높이가 산정되었으며, 강섬유 보강 콘크리트의 물성 평가를 위해 압축강도, 휨강도, 휨인성 지수, 인장강도, 피로강도를 측정하였다. 슬럼프와 공기량은 대부분이 시방 기준을 만족하였으며, 28일 강도도 교통개방을 할 수준 정도로 발현되었다. 휨강도 실험 결과, 강섬유 보강 콘크리트가 무보강 콘크리트에 비해 휨인성은 증가하였지만 휨강도는 증가하지 않았다. 에너지 흡수능력, 피로 저항성 및 동결 융해저항성은 강섬유 보강 콘크리트가 무보강 콘크리트에 비해 향상되었다. 향후, 시험시공을 통해 강섬유 보강 콘크리트의 현장 적용성 및 공용성을 평가할 것이다.
        4,000원
        56.
        2009.12 구독 인증기관 무료, 개인회원 유료
        4,000원
        57.
        2008.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        TR-CFT(Transversely Reinforced Concrete Filled Steel Tube) 기둥은 CFT 기둥의 국부좌굴부위를 탄소섬유쉬트로 보강을 하여 국부좌굴을 방지하거나 지연시키는 기둥부재이다. 본 연구에서는TR-CFT 기둥의 휨내력 산정을 위한 설계식을 제안하였다. CFT 기둥의 ACI 설계식은 강관내부에 발생하는 콘크리트의 구속효과를 고려하지 않아 저평가 되고 있다. 따라서 본 연구에서는 구속효과를 고려한 콘크리트의 응력-변형률 곡선를 이용하여 CFT 기둥과 TR-CFT 기둥의 휨내력 산정식을 제안했으며 해석에 의한 예측 값들은 실험값과 잘 일치함을 확인할 수 있었다.
        4,000원
        58.
        2008.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        CFT(Concrete Filled Steel Tube)기둥은 부재의 합성효과와 경제적인 측면 때문에 최근 고층건물 시공 시 널리 쓰이고 있다. 그러나 기존의 연구문헌을 살펴보면 CFT 기둥은 강관의 항복이후 강관의 일정지점에 국부좌굴이 생기는 단점을 지니고 있다. 이러한 문제점을 해결하기 위하여 예상 국부좌굴부위를 탄소섬유쉬트로 보강하여 국부좌굴을 방지하거나 지연시키는 TR-CFT (Transversely Reinforced Concrete Filled Steel Tube) 기둥에 관한 연구가 진행되고 있다. 본 연구에서는 고강도 콘크리트를 사용한 TR-CFT기둥의 실험을 수행하였으며 휨내력에 대한 해석을 수행한 결과 실험값과 해석값이 잘 일치하였다. 또한 기존의 ACI 318 설계법은 강관내부에서 발생하는 콘크리트에 대한 구속효과를 고려하지 않아 저평가가 되어있음을 알 수 있었다.
        4,000원
        59.
        2007.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 포장재로서 투수콘크리트의 실질적인 현장적용을 위한 자료제시와 성능향상 방안을 도출하기 위하여 슬래그골재와 플라이애시의 혼입률에 따른 포장용 투수콘크리트의 역학적 특성을 평가하였다. 시험결과, 포장용 투수콘크리트의 공극률 및 투수계수는 슬래그골재의 혼합비율이 증가함에 따라 증가하고 플라이애시 혼입률 증가에 의하여 감소하는 경향을 나타내었으며 국내 포장용 투수콘크리트에 관한 규정(8% 및 0.01cm/sec)을 만족하였다. 압축강도 및 휨강도는 슬래그골재의 혼입률이 증가함에 따라 감소하였으나, 플라이애시의 혼입률이 증가함에 따라 크게 증가하는 경향을 나타내어 플라이애시를 5% 이상 혼입하면 슬래그골재를 50% 사용한 경우에도 국내 포장콘크리트에 관한 규정(18MPa 및 4.5MPa 이상)을 만족하였다. 또한 강섬유를 0.75vol.% 혼입한 경우 사용하지 않은 경우에 비하여 휨강도가 22.8% 증가 하였다. 미끄럼저항성은 슬래그골재의 혼입률이 증가에 따라 BPN값은 증가하였고, 플라이애시의 혼입률 증가에 의해 BPN값은 감소하는 경향을 나타내었으며, 내마모성 및 동결융해저항성은 부순골재만을 사용한 경우에 비해 슬래그골재의 혼합비율이 증가함에 따라 감소하였고, 플라이애시를 10% 혼입한 경우에는 현저히 개선되어 혼입하지 않은 경우에 비하여 내마모성 및 내동해성이 각각 약 5.6% 및 14.3% 정도 개선되는 것으로 확인되었다.
        4,300원