        41.
        2018.11 구독 인증기관·개인회원 무료
        Commercial polystyrene-based ion exchange membranes have simple manufacturing processes, they also possess the poor durability due to their brittleness. Poly(ethylene glycol)methyl ether methacrylate with hydrophilic side chain of poly(ethylene glycol) (PEG) was used as a co-monomer to make the membranes have improved flexibility. Hydrophilicity of the anion exchange membrane was able to be adjusted by varying the chain lengths of the PEG polymers. For the preparation of the anion exchange membranes, a porous PE substrate was immersed into monomer solutions and thermally polymerized and crosslinked. The prepared membranes were then subsequently post-aminated using trimethylamine(TMA). The prepared pore-filled anion exchange membranes were evaluated in terms of ion exchange capacity(IEC), electric resistance(ER) and water uptake.
        42.
        2018.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        축전식 탈염(capacitive deionization)에 이용할 수 있는 폴리페닐렌 옥사이드(PPO) 음이온 교환막의 가교결합에 대해 조사하였다. 브롬화와 아민화 반응단계를 거쳐 PPO 음이온 교환 고분자를 제조하고 비스페놀 A 디글리시딜에테르 (BADGE), m-페닐렌디아민(m-PDA), 헥사메틸렌디아민(HMDA) 등으로 가교하였다. 가교에 따른 겔화되는 시간은 HMDA > m-PDA > BADGE 순으로 짧았으며, 일정한 함량 이상으로 실온에서 가교하면 1-메틸피롤리돈(NMP)과 같은 비양성자성 용매(aprotic solvent)에 녹지 않아 내화학성이 증대되었다. 가교제(BADGE) 함량에 따른 음이온 교환막의 이온 교환 용량과 함 수율을 측정하고 비교하였다. HMDA 용액에 침적하여 표면 가교한 PPO 음이온 교환막을 축전식 탈염에 적용한 결과 그 탈염 성능은 가교하지 않은 막과 비교하여 흡착단계의 초기 부분을 제외하고 거의 차이가 없었다.
        4,000원
        43.
        2018.05 구독 인증기관·개인회원 무료
        Commercial polystyrene-based ion exchange membranes have simple manufacturing processes, they also possess the poor durability due to their brittleness. Poly(ethylene glycol)methyl ether methacrylate with hydrophilic side chain of poly(ethylene glycol) (PEG) was used as a co-monomer to make the membranes have improved flexibility. Hydrophilicity of the anion exchange membrane was able to be adjusted by varying the chain lengths of the PEG polymers. For the preparation of the anion exchange membranes, a porous PE substrate was immersed into monomer solutions and thermally polymerized and crosslinked. The prepared membranes were then subsequently post-aminated using trimethylamine (TMA). The prepared pore-filled anion exchange membranes were evaluated in terms of ion exchange capacity (IEC), electric resistance (ER) and water uptake.
        44.
        2018.05 구독 인증기관·개인회원 무료
        There is a great importance in the development of anion exchange membrane fuel cells (AEMFCs) for renewable energy research. The high conductivity and alkaline stability under high pH conditions at elevated temperatures are required for AEMs. We report herein SEBS-based AEMS with different hydrophobic side chain lengths, and investigated the properties of the corresponding AEMs, including conductivity, morphology and chemophysical stabilities.
        45.
        2018.05 구독 인증기관·개인회원 무료
        Anion exchange membrane fuel cells (AEMFCs) have been considered as a promising energy device. To make highly efficient AEMs, high ion conductivity, mechanical stabilities and alkaline stabilities are required. High ion conductivity generally accompanies poor mechanical properties, and crosslinking has been widely applied to overcome these problems. Our groups introduced novel terminally-crosslinked piperidinium-functionalized poly(arylene ether sulfone)s as a anion exchange membrane. Unlike the typical AEMs, our terminally-crosslinked membranes are expected to have high conductivity, especially at low RH conditions due to enhanced water-holding capacity, while maintaining the high chemophyscial stabilities by crosslinking. The synthesis, and properties of the prepared membranes will be discussed in detail.
        46.
        2017.11 구독 인증기관·개인회원 무료
        기존에 많이 이용되고 있는 전기탈이온(EDI) 공정은 전기투석법과 이온교환수 지법을 혼합한 공정이다. 이 공정에 이용되는 모듈은 전기투석을 위한 양・음이 온교환막, 두 막 사이에 이온교환수지로 채워지는 형태이다. 하지만 이온교환수지와 양・음이온교환막으로 인해 모듈의 크기가 커지는 단점이 있다. 이러한 점 들을 바탕으로 현재 이온교환수지를 글라인딩하여 바이폴라형태의 막으로 만든 전기흡착탈이온 공정 모듈이 생산되고 있다. 본 연구는 모듈에 적용할 수 있는 높은 이온교환능력을 가지는 이온교환고분자를 합성하고, 이온교환수지을 대신 할 이온교환그룹을 가진 나노입자를 제조하여 이 둘을 적절하게 조절하여 하이브리드막을 제조하였다. 그리고 제조된 하이브리드막은 다양한 특성평가를 실시하였고, 그에 따른 고찰을 진행하였다.
        47.
        2017.11 구독 인증기관·개인회원 무료
        While commercial polystyrene-based ion exchange membranes have simple manufacturing processes, they also possess the poor durability due to their brittleness. Poly(ethylene glycol)methyl ether methacrylate with hydrophilic side chain of poly(ethylene glycol) (PEG) was used as a co-monomer to make the membranes have improved flexibility. Hydrophilicity/hydrophobicity of the anion exchange membrane was able to be adjusted by varying the chain lengths of the PEG. For the preparation of the anion exchange membranes, a porous PE substrate was immersed into monomer solutions and thermally polymerized. The prepared membranes were then subsequently post-aminated using trimethylamine. The prepared pore-filled anion exchange membranes were evaluated in terms of ion exchange capacity, electric resistance and water uptake.
        48.
        2017.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        바나듐 산화환원 흐름 전지에 핵심적으로 사용되는 이온교환막은 일반적으로 양이온교환막을 사용하고 있으나 co-ion인 바나듐 이온의 투과에 의한 장기적 성능 저하 문제를 해결하기 어렵다. 따라서 본 연구에서는 바나듐 투과도 및 장 기 운전 안정성의 특성을 파악하기 위해 세 가지 다른 관능기를 보유한 음이온교환막을 제조하였다. 기저막으로는 다공성 폴 리에틸렌 필름에 benzyl chloride (VBC)과 divinylbenzene (DVB)을 충진 및 가교 중합하여 제조한 후, 세 가지 다른 아민 관 능기를 각각 도입하였다. 제조된 음이온교환막들에 대해 바나듐 이온 투과 정도 및 장기 운전 안정성을 관찰한 결과 triethylamine을 관능기로 적용한 음이온교환막에서 높은 에너지효율을 유지하면서도 가장 장기적 운전 안정성을 확보할 수 있었다.
        4,000원
        49.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        전해질막을 사용하는 알칼라인 연료전지는 최근 들어서 시스템 구성이 비슷하고 전해질막의 종류만 다른 기존의 양이온 교환막 연료전지를 대체할 수 있을 것으로 기대를 모으고 있다. 특히, 알칼라인 연료전지에서는 비백금계 저가 촉매가 사용 가능하여 많은 연구들이 진행되고 있다. 본 연구에서는 이러한 알칼라인 연료전지 시스템에 적용하기 위한 고성능, 고내 구성 음이온 교환막을 제조하기 위하여, 두 종류의 다공성 지지체인 폴리벤조옥사졸 지지체와 폴리에틸렌 지지체에 Fumion FAA 이오노머를 함침시켜, 기존의 Fumion 시리즈의 막보다 우수한 기계적 강도를 가지면서 높은 이온전도도를 유지할 수 있는 함침막을 제조하고자 하였다. 이를 통하여 최종적으로 지지체-함침막이 성공적으로 제조되었고, 이온 전도도와 기계적 특성이 지지체의 성질에 따라 서로 다른 결과를 보여 주었다. PE 지지체에 Fumion 이오노머를 함침시킨 함침막에서는 우수 한 기계적 특성이 얻어졌지만, 이온전도도는 감소하였으며 특히 높은 온도에서 성능감소가 더욱 증가하였다. 반면에 PBO 지 지체에 Fumion 이오노머를 함침 시킨 경우에는 PBO의 높은 염기성으로 인하여 함침 후에 높은 이온 전도도를 보였지만, Fumion-PE막에 비하여 상대적으로 낮은 기계적 특성을 나타내었다. 결과적으로 지지체-함침막 제조 시 알칼라인 연료전지의 운전조건에 따라 지지체의 특성을 충분히 고려하여 연구를 진행할 필요가 있다는 결론을 얻었다.
        4,000원
        50.
        2017.05 구독 인증기관·개인회원 무료
        The anion exchange membrane fuel cells (AEMFCs) have been regarded as the promising power sources. To develop promising AEMs, the most important components in AEMFCs, the properties of the conducting groups as well as the polymer backbones should be both considered. We recently developed PPO-based anion exchange membranes having various conducting groups, including ammonium, imidazolium, mopholinium. The preparation, characterization and properties of the corresponding membranes will be discussed in detail.
        51.
        2016.11 구독 인증기관·개인회원 무료
        Reverse electrodialysis (RED) is green energy technologies to produce electric power using the salinity gradient. The salinity gradient generates chemical potential difference by transport of ions through the membranes. In RED system, anion exchange membrane (AEM) and cation exchange membrane (CEM) play a major role in transporting cation (Na+) and anion (Cl-), respectively. Significant technical issue is how to enhance conductivity and permselectivity of membrane simultaneously in the system. In this study, we characterized influences of cationic functional groups on AEM. We evaluated conductivity and permselectivity of AEM introduced three types of cationic salt functional groups.
        52.
        2016.11 구독 인증기관·개인회원 무료
        While commercial polystyrene-based ion exchange membranes have simple manufacturing processes, they also possess the poor durability due to their brittleness. Poly(ethylene glycol)methyl ether methacrylate with hydrophilic side chain of poly(ethylene glycol) (PEG) was used as a co-monomer to make the membranes have improved flexibility. Hydrophilicity/hydrophobicity of the anion exchange membrane was able to be adjusted by varying the chain lengths of the PEG. For the preparation of the anion exchange membranes, a porous PE substrate was immersed into monomer solutions and thermally polymerized. The prepared membranes were then subsequently post-aminated using trimethylamine. The prepared pore-filled anion exchange membranes were evaluated in terms of ion exchange capacity, electric resistance and water uptake.
        53.
        2016.11 구독 인증기관·개인회원 무료
        The water uptake, ionic conductivity, vanadium (VO2+) permeability and stability of polysulfone (PSF) based AEMs in alkaline media and in strongly oxidizing solutions were assessed. The highest ion conductivity was obtained with PSF-trimethylammonium (TMA)+. PSF-TMA+ also had better alkaline stability in comparison to PSF-AEM with different bases. PSF-TMA+ was demonstrated to show fuel cell performance. PSF-TMA+ demonstrated a 40-fold reduction in vanadium (VO2+) permeability when compared to Nafion® membrane. Comprehensive 2D NMR studies verified that PSF-TMA+ remained chemically stable even after exposure to a 1.5 M vanadium(V) solution for 90 days. Excellent energy efficiencies (85%) were attained and sustained over several charge–discharge cycles for a vanadium redox flow battery prepared using the PSF-TMA+ separator.
        54.
        2016.05 구독 인증기관·개인회원 무료
        AEMFCs have been realized as a desirable alternative to PEMFCs. AEMs are the most important components of AEMFCs, and the high ion conductivity, good dimensional, mechanical and alkaline stabilities are required for AEMs. High conductivity mostly leads to a poor dimensional and mechanical stabilities. Chemical cross-linking of polymers have been attempted in an effort to overcome these problems, but the cross-linking inevitably reduced the conductivity due to the increased hydrophobicity of the membrane. Our group developed terminal crosslinking in which cross-linking was restricted only to the terminus of the polymer chains to minimize the loss of conductivity. Synthesis and properties of these terminally-crosslinked membranes will be detailed.
        55.
        2016.05 구독 인증기관·개인회원 무료
        The anion exchange membrane fuel cells (AEMFCs) have been regarded as the promising power sources. To develop promising AEMs, the most important components in AEMFCs, the properties of the conducting groups as well as the polymer backbones should be both considered. We recently developed PPO-based anion exchange membranes having various conducting groups, including ammonium, imidazolium, mopholinium. The preparation, characterization and properties of the corresponding membranes will be discussed in detail.
        56.
        2016.05 구독 인증기관·개인회원 무료
        Alkaline direct liquid fuel cells (ADLFCs) employing anion-exchange membranes as a fuel barrier have attracted significant attention as promising alternative energy sources. ADLFCs are allowed to use more abundant anode catalysts which are cheaper than the catalyst used in that using hydrogen fuel. In this work, novel pore-filled anion-exchange membranes (PFAEMs) were successfully fabricated by combining a highly porous poly(tetrafluoroethylene) film and cationic polyelectrolytes with structurally stable anion-exchange sites. The results of the membrane characterizations revealed that the optimization in the crosslinking degree and hydrophilicity of membranes should be considered for the successful application of the PFAEMs to ADLFCs. (KETEP)(20153030031720) and (MOTIE) (No. 10047796).
        57.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        상업적으로 이용되는 폴리스티렌계 이온교환막은 제조 공정이 쉽고 간단하지만 막이 가지는 취성 때문에 내구성이 약하다는 단점을 가지고 있다. 이를 보완하기 위하여 친수성 그룹인 poly(ethylene glycol)을 곁사슬로 가지고 있는 poly(ethylene glycol)methyl ether methacrylate를 공중합시켜 음이온 교환막을 합성하였다. 지지체로는 내화학성 및 기계적 강도가 우수한 다 공성 PE 지지체를 사용하였고, 여기에 다양한 조성의 vinylbenzyl chloride, styrene, poly(ethylene glycol)methyl ether methacrylate, divinylbenzene, benzoyl peroxide를 녹인 단량체 용액을 지지체 기공에 채운 뒤 열중합 가교시켜 trimethylamine을 이 용하여 음이온 교환기를 도입해 세공충전 음이온 교환막을 합성하였다. 또한 poly(ethylene glycol)methyl ether methacrylate의 곁사슬 길이와 각 단량체가 차지하는 비율의 변화가 음이온 교환막의 전기화학적 특성에 미치는 영향을 알아보았다.
        4,000원
        58.
        2015.11 구독 인증기관·개인회원 무료
        Reverse electrodialysis (RED) is one of the promising processes for generating electricity from the salt concentration gradient between river and sea water. A RED stack contains alternately arranged anion and cation exchange membranes which separate salt solutions of different concentrations. The power generation performance of RED significantly depends on the characteristics of ion exchange membranes. In this work, we have prepared high performance pore-filled anion-exchange membranes. In addition, the optimization of membrane design parameters has been investigated using the membranes via various electrochemical analyses in terms of the enhancement of RED performances. Finally, the membrane surface has been modified with acid-doped polypyrrole for the improvement of the membrane properties. (No. 10047796) (No. 2015H1C1A1034436)
        59.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 이온교환막을 이용한 전기화학적 수처리 공정의 효율을 향상시키기 위해 낮은 전기적 저항, 높은이온선택 투과성, 및 농도분극 조건에서 낮은 물분해 플럭스 특성을 갖는 새로운 세공충진 음이온 교환막을 개발하였다. 다공성 폴리올레핀 기재에 이온교환능이 우수한 4급 암모늄기를 포함한 공중합 고분자를 충진하여 상용막 이상의 성능을 갖는 기저 멤브레인을 제조하였다. 또한 기저 막 표면에 이미다졸륨 고분자를 코팅하여 전기화학적 성능을 유지하며 동시에 물분해플럭스를 효과적으로 제어할 수 있음을 확인하였다. 제조된 세공충진 음이온 교환막은 상용막 대비 약 1/6∼1/8 수준의 매우낮은 전기적 저항을 나타내었으며 동시에 농도분극 조건에서 양이온 교환막 수준의 낮은 물분해 플럭스를 나타내었다
        4,000원
        60.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        폴리스티렌계 음이온교환막은 제조가 쉽고 공정이 간단한 장점을 갖고 있으나 막의 취성이 높아 내구성이 떨어지 는 단점을 가지고 있다. 이를 보완하여 유연하고 우수한 내구성을 갖는 막을 만들기 위해 acrylonitrile-butadiene rubber를 첨 가제로 사용하여 음이온교환막을 제조하였다. 다양한 조성의 vinylbenzylchloride와 styrene, divinylbenzene, acrylonitrile- butadiene rubber 그리고 benzoyl peroxide로 이루어진 단량체 용액을 지지체인 직물 형태의 지지체인 poly(propylene)위 에 캐스팅 후 열중합 가교시킨 다음 trimethylamine과 acetone을 이용하여 음이온 교환기(-N+(CH3)3)를 함유하는 복합막을 제 조하였다. 음이온 교환막 제조시 첨가제의 함량에 따른 막의 성능을 평가하여 최적화 비율을 찾고, 단량체의 함량을 변화하여 함수율, 이온교환용량(IEC) 및 전기저항 값을 측정하였다. 그 결과 최적화 비율로 제조된 막들은 아스톰사의 상용화 음이온 교환막(AMX)보다 높은 IEC와 낮은 전기저항 값을 나타내는 동시에 유연성과 내구성이 우수한 막이 만들어진 것을 확인할 수 있었다.
        4,000원
        1 2 3 4