검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 92

        66.
        1995.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        One of the most destructive forces around greenhouses is wind. Wind loads can be obtained by multiplying velocity pressure by dimensionless wind force coefficient. Generally, wind force coefficients can be determined by wind tunnel experiments. The wind force coefficient distribution on a single - span arched greenhouse was estimated using experimental data and compared with reported values from various countries. The results obtained are as follows : 1. The coefficients obtained from this study agree with the values proposed by G. L. Nelson except about 0.5 of difference in the middle region of roof section. This discrepancy is mainly attributed to the dissimilarity of experimental conditions (or wind tunnel test such as Reynolds number, type of terrain, surface roughness of model, location of the lapping and measuring methods. 2. Considering that the wind force coefficients are varied along the height of a wall at wind direction perpendicular to wall, structural analysis using subdivided wind force coefficient distribution is more resonable for wall. 3. It is recommendable that wind force coefficient distribution on a roof should take more subdivision than the existing four equal divisions for more accurate structural design. 4. Structural design using wind forces close to real values is more advantageous in safety and expense.
        4,000원
        67.
        1989.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 확률에 기초한 한국의 기본 설계풍속 추정을 위한 합리적인 방법을 제시하고 위험도에 기초한 전국의 설계풍속지도를 제안한다. 본 논문에서는 장기기록 지역의 계절풍 연 최대 풍속자료와 단기기록 지역의 계절풍 월 최대 풍속자료의 극치 Type I 분포 모형에 대한 적합성을 검토하였고, 극치 태풍 풍속 분포 추정에서는 Monte-Carlo 시뮬레이션을 이용하여 간접적인 해석방법이 적용되었다. 태풍과 계절풍에 대한 기본 설계풍속은 두개 분포의 적(product)으로 된 혼합모형에서 구한다. 본 연구 결과로부터 제안된 모형과 방법은 현재 한국에서 가용한 단기기록 풍속자료를 이용한 위험도에 기초한 기본설계풍속과 기본 설계풍속지도의 개발에 실용적인 도구로 활용 가능하다고 본다.
        4,200원
        68.
        2019.10 서비스 종료(열람 제한)
        고층건물의 설계에서는 풍하중이 지진하중에 비해 지배적이며, 탄성 설계만을 허용하는 국내 설계기준(KBC 2016)으로 인해, 구조물에 과도한 배근이 되고 성능기반 내진설계에서 취성적인 거동을 보이게 된다. 이러한 문제를 해결하기 위해 내풍 설계에서도 비탄성을 고려한 성능기반 내풍설계가 요구된다. 이를 위해 공진 성분에 반응수정계수를 도입하여 비탄성 설계를 수행하고, 이를 풍동실험이나 파워스펙트럼으로부터 시간이력 하중을 재생하여 비선형 시간이력해석을 통해 성능을 검증하여, 구조물의 안전성과 경제성을 확보할 수 있다.
        69.
        2018.07 KCI 등재 서비스 종료(열람 제한)
        해상풍력 지지구조물은 설치과정에서 수직도 오차가 발생하여 풍력발전기 전체 구조의 안전성이 저하될 수 있다. 따라서, 본 논문에서는 콘크리트 중력식 해상풍력 연결부에서 PS 앵커와 앵커체결구 그라우트를 사용하여 수직도를 조정할 수 있는 방안에 대한 연구를 수행 하였다. 연결부는 5MW급 해상풍력 지지구조물에서 발생한 수직도 오차를 최대 0.5°까지 보정하는 것을 목표로 하였다. 우선, 수직도 조정이 가능한 해상풍력 연결부에 대해 주요 부재별 설계안과 설계절차를 제안하고, 제주도 해상지역을 대상으로 설계 제원을 산출하였다. 그 후, 설계 제원에 대해 비선형 3차원 유한요소해석을 수행하여 설계안의 적정성을 검토하였다. 검토 결과, 하중 전달 메커니즘과 연결부 발생 응력 확인을 통해 제안 설계안은 0.5°의 수직도 오차를 보정하여도 안전하다고 판단하였다.
        74.
        2017.09 서비스 종료(열람 제한)
        Transition piece of offshore wind turbine tower is one of the main parts which takes the direct load and pass on to the lower support structure. In this study, a new design method for the transition piece has been developed. The trasition piece was designed based on the the load flow which was analyzed by approximation and was evaluated by FEM.
        75.
        2017.09 서비스 종료(열람 제한)
        It is necessary to develop the damage function to cope with the increasing damage of steel transmission towers. A simplify analysis to evaluate the performance resistance capacity, which is essential for the development of the damage function, was performed. The 154kv power transmission towers installed between Sokcho and Yangyang were selected as the target structures. Wind loads were calculated and applied to the target structures according to the domestic transmission and distribution facility design standards. As a result of this study, displacement according to wind speed of the target structure was derived.
        76.
        2017.04 서비스 종료(열람 제한)
        In this paper, we research about integrated jacket support structure. The connection of the offshore wind support structure was designed based on the DNV-RP-C201 standard and the design of the appropriate type was derived through numerical calculation and finite element analysis of the stress paths of various connecting part type.
        77.
        2016.10 서비스 종료(열람 제한)
        Recently, wind turbine industry have received more attention than before. Many countries including South Korea focus on the offshore wind turbine because of its geographical advantage. However, domestic technique level is much lower than that of advanced countries such as Europe. In this study, analysis on development trend of offshore wind turbine and design standard in Europe is carried out to develop the original design standard.
        80.
        2016.04 서비스 종료(열람 제한)
        An ICH RC (internally confined hollow reinforced concrete) tower for supporting 5.0MW wind turbine was developed and its standard sections were designed. It was found that ICH RC wind tower is satisfied with maximum 200% bigger moment which is required for pre-existing steel tower. Also, the results from the FAST showed that 5.0MW turbine can be normally operated with the ICH RC tower.