        검색결과 731

        161.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this experimental research is to evaluate the workability and strength properties of hybrid fiber reinforced concrete containing amorphous steel fiber and organic fiber. For this purpose, the hybrid fiber reinforced concrete containing amorphous steel fiber(ASF) with polyamide(PA) and polyvinyl alcohol(PVA) fiber, respectively were made according to their total volume fraction of 0.5% for water-binder ratio of 33%, and then the characteristics such as the workability, compressive strength, and flexural strength of those were investigated. It was observed from the test results that the workability and compressive strength at 7 and 28 days were decreased and the flexural strength at 7 and 28 days was increased with increasing ASF and decreasing organic fiber.
        4,000원
        162.
        2015.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기존 구조물의 손상평가에 관한 연구는 지진 등과 같은 과도한 하중에 의한 손상을 고려하였다. 그러나 구조물은 과도한 하중없이도 장기간의 시간에 따라 염화물, 탄성화 등과 같은 이유로 노후화가 진행되어 구조성능이 저하될 수 있다. 그래서 구조물의 건전도를 효과적으로 관리하기 위해서는 노후화에 의한 구조성능 저하도 검토되어야 한다. 본 연구에서는 염화물에 의한 철근의 부식을 노후화 요인으로 고려한다. 철근부식에 의한 재료의 구조성능 저하를 고려하기 위해 부식정도에 따른 철근의 단면적, 항복강도, 파단변형률, 피복 콘크리트 강도 등을 예측한다. 이를 구조모델링에 적용하여 구조부재 및 구조물의 구조성능 저하를 분석한다. 구조부재의 구조성능을 분석하기 위해 모멘트-곡률 해석을 수행한다. 구조물 레벨의 구조성능을 고려하기 위해, 고유치해석을 통한 고유주기와 모드형상을 분석한다. 또한 비선형 정적해석을 통해 구조물의 강도와 변형성능을 분석한다.
        4,000원
        163.
        2015.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        건물외피 발생하는 열교현상은 건물의 단열성능 및 외피의 내구성에 영향을 미치며, 국내의 일반적인 주거형식인 공동주택의 발코니에 있어서 이러한 열교현상은 중요하게 고려되고 있다. 이와 같이 내·외부 발코니 슬래브 사이에서 발생하는 열교현상을 최소화하기 위한 목적으로 열교차단장치가 개발되었으며 다수의 건설현장에서 적용되고 있다. 철근콘크리트 슬래브 벽-슬래브 접합부에 열교차단장치를 적용함으로써 건물의 단열성능을 향상될 수 있으나 풍하중과 같은 양방향의 하중에 의해 열교차단장치 삽입부위가 적합한 구조성능을 확보하고 있는지에 대한 검증이 요구된다. 따라서 본 연구에서는 철근콘크리트 슬래브에 적용된 열교차단장치의 구조성능을 확인하기 위해 변위제어 방식으로 30 싸이클의 반복하중을 가력하였다. 열교차단장치가 삽입된 접합부는 요구되는 구조성능을 확보하며, 최대 모멘트강도, 에너지소산능력, 연성비가 기존의 철근콘크리트 슬래브와 비교하여 향상되는 것으로 나타났다.
        4,200원
        164.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Reinforced concrete shear walls are effective for resisting lateral loads imposed by wind or earthquakes. Observed damages of the shear wall in recent earthquakes in Chile(2010) and New Zealand(2011) exceeded expectations. Various analytical models have been proposed in order to incorporate such response features in predicting the inelastic response of RC shear walls. However, the model has not been implemented into widely available computer programs, and has not been sufficiently calibrated with and validated against extensive experimental data at both local and global response levels. In this study, reinforced concrete shear walls were modeled with fiber slices, where cross section and reinforcement details of shear walls can be arranged freely. Nonlinear analysis was performed by adding nonlinear shear spring elements that can represent shear deformation. This analysis result will be compared with the existing experiment results. To investigate the nonlinear behavior of reinforced concrete shear walls, reinforced concrete single shear walls with rectangular wall cross section were selected. The analysis results showed that the yield strength of the shear wall was approximately the same value as the experimental results. However, the yielding displacement of the shear wall was still higher in the experiment than the analysis. The analytical model used in this study is available for the analysis of shear wall subjected to high axial forces.
        4,000원
        165.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        For small-size reinforce-concrete buildings, Midas Gen, OpenSees, and Perform-3D, which are structural analysis programs that are most popularly used at present, were applied for nonlinear static pushover analysis, and then difference between those programs was analyzed. Example buildings were limited to 2-story frames with irregular shaped walls. Analysis result showed that there were more differences than for frames only and frames with rectangular walls, but it was not so significant. Nevertheless, the capacity curve were different in some buildings, which is attributed to shape and location of walls, and feature of the analysis program. Especially, selection of automatic or manual input in Midas Gen, or nonlinear wall elements in Perform3D can affect the capacity curve and performance of the buildings. Therefore, the program users should understand the feature of the program well, and then conduct performance assessment. The result of this study is limited to low-story buildings so that it should be noted that it is possible to get different results for mid- to high-rise buildings.
        4,000원
        166.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        For small-size reinforce-concrete buildings, Midas Gen, OpenSees, and Perform-3D, which are structural analysis programs that are most popularly used at present, were applied for nonlinear static pushover analysis, and then difference between those programs was analyzed. Example buildings were limited to 2-story frames only and frames with one or more rectangular walls. Analysis results showed that there was not much difference for frames only based on capacity curves. There were some differences for frames with rectangular walls, but it was not so significant. The global behaviors represented by the capacity curve were not so different, but the feature of each analysis program appeared when the results were analyzed in more detail. Therefore, the program users should understand the feature of the program well, and then conduct performance assessment. The result of this study is limited to low-story frames only and frames with rectangular walls so that it should be noted that it is possible to get different results for frames with non-rectangular walls or mid- to high-rise buildings.
        4,000원
        167.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근들어 철근콘크리트 슬래브와 벽의 연결부에 적용 가능한 열교차단장치에 대한 연구가 다수 수행되고 있다. 이에 본 연구에서는 열교차단장치가 적용된 슬래브의 균열 전 탄성거동, 균열 후 항복거동 및 극한강도까지 적용이 가능한 해석모델을 제안하고, 실험결과와의 비교를 통하여 제안 모델의 정확도를 검증하고자 하였다. 해석모델은 변형률 적합조건과 힘의 평형개념을 적용하였으며, 이 때 구성 재료의 응력-변형률 관계는 재료실험 결과를 적용하였다. 해석모델의 신뢰성 검증을 위해 모멘트-곡률 관계, 하중단계에 따른 중립축을 실험결과와 비교하였으며, 제안된 해석모델은 실험결과로 획득한 전체적인 휨거동 양상과 거의 일치함을 확인할 수 있었다.
        4,000원
        168.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.
        4,500원
        169.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims at developing a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. Top shear connection of the PC panel was required to show the composite strength of RC column and PC wall panel. However, the strength of the connection did not influence directly on the ultimate loading capacities of the specimens in the positive loading because the loaded RC column push the side of PC wall panel and it moved horizontally before the shear connector receive the concentrated shear force in the positive loading process. Under the positive loading sequence(push loading), the reinforced concrete column and PC panel showed flexural strength which is larger than 97% of the composite section because of the rigid binding at the top of precast panel. Similar load-deformation relationship and ultimated horizontal load capacities were shown in the test of PR1-LA and PR1-LP specimens because they have same section dimension and detail at the flexural critical section. An average of 4.7 times increase in the positive maximum loading(average 967kN) and 2.7 times increase in the negative maximum loading(average 592.5kN) had resulted from the test of seismic resistant specimens with anchored and welded steel plate connections than that of unreinforced beam-column specimen. The maximum drift ratios were also shown between 1.0% and 1.4%.
        4,200원
        170.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Ultra High Performance Fiber Reinforced Concrete (UHPFRC) has a outstanding tensile hardening behaviour after a crack develops, which gives ductility to structures. Existing shear strength model for fiber reinforced concrete is entirely based on crack opening behavior(mode I) which comes from flexural-shear failure, not considering shear-slip behavior(mode II). To find out the mode I and mode II behavior on a crack in UHPFRC simultaneously, maximum shear strength of cracked UHPFRC is investigated from twenty-four push-off test results. The shear stress on a crack is derived as variable of initial crack width and fiber volume ratio. Test results show that shear slippage is proportional to crack opening, which leads to relationship between shear transfer strength and crack width. Based on the test results a hypothesis is proposed for the physical mechanics of shear transfer in UHPFRC by tensile hardening behavior in stead of aggregate interlocking in reinforced concrete. Shear transfer strength based on tensile hardening behavior in UHPFRC is suggested and this suggestion was verified by comparing direct tensile test results and push-off test results.
        4,000원
        171.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : In this study, a fracture-based finite element (FE) model is proposed to evaluate the fracture behavior of fiber-reinforced asphalt (FRA) concrete under various interface conditions. METHODS: A fracture-based FE model was developed to simulate a double-edge notched tension (DENT) test. A cohesive zone model (CZM) and linear viscoelastic model were implemented to model the fracture behavior and viscous behavior of the FRA concrete, respectively. Three models were developed to characterize the behavior of interfacial bonding between the fiber reinforcement and surrounding materials. In the first model, the fracture property of the asphalt concrete was modified to study the effect of fiber reinforcement. In the second model, spring elements were used to simulated the fiber reinforcement. In the third method, bar and spring elements, based on a nonlinear bond-slip model, were used to simulate the fiber reinforcement and interfacial bonding conditions. The performance of the FRA in resisting crack development under various interfacial conditions was evaluated. RESULTS : The elastic modulus of the fibers was not sensitive to the behavior of the FRA in the DENT test before crack initiation. After crack development, the fracture resistance of the FRA was found to have enhanced considerably as the elastic modulus of the fibers increased from 450 MPa to 900 MPa. When the adhesion between the fibers and asphalt concrete was sufficiently high, the fiber reinforcement was effective. It means that the interfacial bonding conditions affect the fracture resistance of the FRA significantly. CONCLUSIONS: The bar/spring element models were more effective in representing the local behavior of the fibers and interfacial bonding than the fracture energy approach. The reinforcement effect is more significant after crack initiation, as the fibers can be pulled out sufficiently. Both the elastic modulus of the fiber reinforcement and the interfacial bonding were significant in controlling crack development in the FRA.
        4,000원
        172.
        2015.04 구독 인증기관 무료, 개인회원 유료
        In constructing the cast-in-place concrete track system, the installation of reinforcing bars to a TCL is one of the main causes of consuming construction time. In this study, to eliminate the reinforcing bar installation process, the applicability of the fiber reinforced concrete to the TCL is studied using the numerical analysis. The analysis is performed using the commercial finite element program, ABAQUS, and, in the analysis, the effect of the variations in fiber content rate and the surrounding temperature is considered. From the analysis, it is found that the fiber reinforced concrete has better applicability than the existing reinforced concrete with steel bar.
        3,000원
        173.
        2015.04 구독 인증기관·개인회원 무료
        This paper deals with the strengthening effect of reinforced concrete beams strengthened with carbon fiber sheets (CFSs). Fifteen strengthened reinforced concrete (RC) beams were experimentally evaluated to determine improvements in structural performance. Test parameters in this experimental study are strengthening ratios and strengthening methods of CFSs (I-S, I-W, U-S, U-W type). RC beams strengthened with CFSs were tested under sustaining load. Considering strengthening ratios and strengthening methods of carbon fiber sheets, structural performance and failure mode of test specimens were evaluated. The results show that maximum capacity of beams strengthened with CFSs is about 28.8% in I-S type, 20.5% in I-W type, 26.0% in U-S type, 28.7% in U-W type higher than that of control beam.
        174.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to improve the previous damage evaluation model for RC members which is proposed by Igarashi[1] in 2010.The previous model was not confirmed by enough data of damage such as, residual crack length, width and area for exfoliation of concrete, etc. In addition, validation of the model is still insufficient. Therefore, experiment of a real-scale RC structure and experiment of RC columns using the high-strength concrete were conducted to gather the data of damage in RC members. The investigation has been conducted gathering the data not only additional experiments data but also existing data for modification of damage evaluation model. It has been investigated on changing damage in RC due to axial force ratio, shear reinforcement and shear span ratio. As a result, several problems were founded in the previous model, such as, hinge length(lp), spacing of flexural crack(Sav,f), total width of flexural cracks regulated by maximum width of flexural crack(nf) and total width of shear cracks regulated by maximum width of shear crack(ns). New model is proposed and evaluated the damage properly.
        4,000원
        175.
        2015.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 논문은 화재에 노출된 철근콘크리트 구조에 대한 수치해석 모델을 제시하고, 기존의 자료 및 설계 규준과의 비교를 통해 구조물의 설계 시 고려 사항에 대해 제안하고 있다. 수치해석은 비정상 열전달 해석과 비선형 구조해석의 두 단계로 수행되며, 비정상 열전달 해석을 통해서 얻어진 화재시간에 따른 단면 온도분포를 바탕으로 비선형 구조해석하여 부재의 상태에 대한 정보를 얻게 된다. 이때, 철근콘크리트의 재료모델을 화재진행상태(Under-Fire)와 화재종료 후 냉각상태(After-Cooling)로 나뉘어 해석수행하여 각각의 재료상태에 따른 거동의 변화를 살펴본다. 해석된 결과는 여러 구조물에 대해 기존의 실험결과와 비교하여 검증하고, 설계 규준과의 비교를 통해 화재 시 구조물의 안전성에 대해 고찰하였다.
        4,500원
        176.
        2015.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The purpose of this study is to investigate the relationship between the crack propagation depth through a slab and crack width movement in continuously reinforced concrete slab systems (CRCSs). METHODS : The crack width movements in continuously reinforced concrete pavement (CRCP) and continuously reinforced concrete railway track (CRCT) were measured in the field for different crack spacings. In addition, the crack width movements in both CRCP and CRCT were simulated using finite element models of CRCP and CRCT. The crack width movements, depending on the unit temperature change, were obtained from both the field tests and numerical analysis models.. RESULTS: The experimental analysis results show that the magnitudes of the crack width movements in CRCSs were related to not only the crack spacing, but also the crack propagation depth. In CRCP, the magnitudes of the crack width movements were more closely related to the crack propagation depths. In CRCT, the crack width movements were similar for different cracks since most were through cracks. If the numerical analysis was performed to predict the crack width movements by assuming that the crack propagates completely through the slab depth, the predicted crack width movements were similar to the actual ones in CRCT, but those may be overestimated in CRCP. CONCLUSIONS: The magnitudes of the crack width movements in CRCSs were mainly affected by the crack propagation depths through the slabs.
        4,000원
        177.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 현재 시공중인 58층의 철근콘크리트조 고층건물에서 진동현식게이지를 통해 계측된 기둥의 축방향 변형률과 레이져 스캐닝을 통해 구한 횡변위를 3차원 시공단계해석에 의한 예측치와 비교하였다. 예측치는 ACI 209와 PCA의 재료모델식, PCA report의 축소량 산정알고리즘을 3차원 구조해석 프로그램으로 개발한 ASAP을 사용하여 구하였다. 비교결과 평면의 중앙부 기둥의 축방향 변형율 계측치는 시공단계 해석치와 거의 유사한 결과를 나타내었으나 각 모서리에 두 개씩 배치된 기둥의 경우 비교적 큰 오차를 나타내었다. 레이져 스캐닝에 의한 횡변위 계측결과는 해석결과와 유사한 경향을 보였으나 층당 계측치가 큰 변동을 나타내므로 향후 이를 해결하기 위한 계측 및 데이터 처리기법이 요구된다.
        4,000원
        178.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        불확실성을 가지는 콘크리트의 특성으로 인해 철근 콘크리트 부재의 처짐에는 높은 변동성이 발생할 수 있다. 그러나 현행 설계규준은 이를 고려하지 않고 경험적인 데이터에 바탕을 두고 있으며, 부재의 최소 두께 또는 최대 허용 처짐만을 제시하고 있다. 본 논문에서는 철근 콘크리트 플랫 플레이트의 처짐 예측이 가능한 유한요소해석 모델에 확률해석 모델을 적용하여 철근 콘크리트 플랫 플레이트 처짐의 변동성을 평가하고자 하였다. 이를 위해 콘크리트, 철근, 부재치수, 인장강성에 관련된 8개 요소를 변수로 한 몬테카를로 시뮬레이션을 수행하였다. 해석결과, 스팬의 크기가 증가할수록 하중으로 인한 처짐에 더 민감하게 반응하는 것으로 나타났으며, 재하되는 활하중의 크기가 클수록, 슬래브의 두께가 작을수록 처짐의 변동성이 큰 것으로 나타났다.
        4,000원
        179.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: The purpose of this study is to evaluate the degree of restraint (DOR) of longitudinal steel at continuously reinforced concrete pavement (CRCP) against environmental loadings. METHODS : To measure the longitudinal steel strain, 3-electrical resistance and self-temperature compensation gauges were installed to CRCP test section (thickness = 250mm, steel ratio = 0.7%) and continuously measured 10 min. intervals during 259 days. In order to properly analyze the steel strains first, temperature compensation process has been conducted. Secondly, measured steel strains were divided into 12 phases with different events such as before paving, during concrete hardening, and after first cracking, etc. RESULTS : Thermal strain rate (TSR) concept is defined as the linear strain variations with temperature changes and restraints rate of longitudinal steel against environmental loadings (especially thermal loading) with different cases is defined as degree of restraint(DOR). New concept of DOR could be indirect indicator of crack width behaviors of CRCP. CONCLUSIONS: Before paving, DOR of longitudinal steel is almost same at the coefficient of thermal expansion of steel (12.44m/m/℃) because of no restraint boundary condition. After concrete pouring, DOR is gradually changed into -1 due to concrete stiffness developing with hydration. After first cracking at crack induced area, values of DOR are around -3~-5. The negative DOR stands for the crack width behavior instead of steel strain behavior. During winter season, DOR reached to -5.77 as the highest, but spring this values gradually reduced as -1.7 as the lowest. Based on this observation, we can presume crack width decreased over time within the time frame of this study. This finding is not consistent with the current theory on crack width variations over time, so further study is necessary to identify the causes of crack width reducing. One of the reasons could be related to concrete stress re-distribution and stress relaxation.
        4,000원
        180.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: To evaluate the feasibility of cut waste fishing net as a reinforced fiber for concrete. METHODS: Strength characteristics of fiber reinforced concrete using waste fishing net were investigated. The cut waste fishing nets with 4~5cm length were putted into the soil-cement and cement concrete for pavement slab. RESULTS: Compression and tensile strength of fiber reinforced concrete using waste fishing net were increased. CONCLUSIONS: It was concluded that cut waste fishing net can be used as a reinforced fiber for cement concrete. However, sometimes using cut waste fishing net leads to decrease the strength; therefore, further researches are needed for real project.
        4,000원