This study was carried out to investigate the proper wattage and installation distance for the efficient use of nano-carbon fiber infrared heating lamp (NCFIHL), a heating device advantageous for heating energy saving, when the production of watermelon plug seedlings in the plug seedling nursery in winter season. Six small beds were divided into plastic film, and 700 W and 900 W nano-carbon fiber infrared heating lamps were installed at 100 cm above the bed. 1 lamp at central (control), 60 cm interval (2 lamps), and 40 cm interval (3 lamps) heating lamps were installed in each bed inside the greenhouse. All treatments, except the control, were set to keep the night air temperature at 20℃ after lighting the NCFIHL. The leaf temperature showed a tendency to increase fast as the install distance was narrow. The leaf length and leaf width tended to increase as the installation distance of the 700 W heating lamp was narrow. The compactness was high in 700 W heating lamp with 40 cm of installation distance. Therefore, in consideration of maintaining the set temperature at night, installing 700 W electric lamps at 40 cm was an efficient power and installation distance for watermelon grafted seedlings considering economic feasibility.
본 연구에서는 고설 딸기 관부(크라운부) 난방시스템을 전기 온수 보일러, 축열조, 순환 펌프, 관부난방 배관 (백색 연질 PE관, 관경 16mm) 및 온도 제어반으로 구성하였다. 관부(크라운부) 난방의 경우 난방 배관을 딸기 관부에 최대한 밀착될 수 있도록 설치하고 배관 위치를 원예용 고정핀으로 고정하였다. 또한 관부 난방시스템의 에너지 효율을 증진하기 위해 축열조 온수 온도를 20~23oC, 관부 온도를 13~15oC로 관리하였다. 관부난방은 전기 온수보일러를 이용하여 20~23oC의 온수를 축열조에 저장하고 순환펌프를 제어하기 위한 온도 센서를 딸기의 관부에 최대한 근접하여 설치하고 온도를 감지함 으로써 관부(크라운부)를 집중적으로 난방하는 방식이다. 시험 온실의 난방 처리는 공간 난방 4oC + 관부난방(처 리 1), 공간 난방 8oC (대조구), 공간 난방 6oC + 관부 난방(처리 2)로 처리하였다. 각 난방처리는 온실 1동에 딸기를 980주를 심었으며, 재배방법은 표준재배법에 준해서 재배하였다. 난방 에너지 소비에 대한 비교시험은 2017년 11월 8일부터 2018년 3월 30일까지 수행되었다. 소비된 누적 전력량은 등유 사용량으로 환산하였고, 등유 소비량은 공간난방 8oC(대조구)의 경우 1,320L (100%), 공간난방 4oC + 관부난방의 경우 928L(70.3%), 공간난방 6oC + 관부난방의 경우 1,161L (88%)로 계측 되었다. 공간난방 4oC + 관부난방(처리 1) 및 공간난방 6oC + 관부난방(처리 2)은 8oC 공간난방(대조구)에 비해 생육 저하, 수확시기의 지연 등이 없이 비슷하게 딸기 수확이 가능하였으며, 29.7% 및 12%의 난방 에너지가 절감되는 것으로 분석되었다.
본 연구에서는 유리온실 경영비 절감을 위한 고효율 난방기술을 개발하기 위하여 지하수열원 히트펌프, 알루미늄 다겹보온커튼, 근권부 국소난방장치를 조합한 난방 패키지 모델을 구성하고 파프리카 재배 벤로형 유리온실에 적용 시험을 수행하였다. 적용효과 분석을 위하여 관행 경유온수보일러와 일반 보온커튼을 설치한 대조구 온실과 비교시험을 통해 온실환경, 난방비용, 작물생육 등을 검토하였다. 알루미늄 다겹보온커튼과 일반 부직포 보온커튼을 설치한 온실에 대한 무가온 조건에서의 야간 온도 비교시험에서 알루미늄 다겹보온커튼 설치 온실의 온도가 일반 부직포 보온커튼 설치 온실에 비해 평균 2.2oC 더 높게 유지됨을 확인하였다. 또한 근권부 국소 난방장치를 설치한 온실에서 미설치 온실에 비해 야간 난방 중의 베드내부 근권온도가 4.7oC 더 높게 유지됨을 확인하였다. 난방패키지를 구성하는 지하수열원 히트펌프의 난방성능을 분석한 결과 지하수를 직접 열원으로 이용하는 시스템 특성상 난방성능계수는 평균 3.7로 비 교적 높게 나타났다. 난방패키지를 적용한 처리구 온실과 관행 난방의 대조구 온실에 대하여 연료소비량을 계 측한 결과 10a(1,000m2)당 대조구 온실은 경유 14,071L, 전력 364kWh를 소비하였고, 처리구는 전력 35,082kWh 를 소비하여 난방비용 기준으로 대조구 온실의 비용 절감율은 87%로 나타났다. 처리구 및 대조구 온실의 작물 생육을 비교한 결과 초장과 엽록소 함량에서 차이가 발생하였으나 두 온실의 난방온도가 거의 동일하므로 전체적인 생육은 큰 차이가 없는 것으로 분석되었다. 원예시설의 난방에너지 절감효과를 극대화하기 위해서는 본 연구의 난방패키지를 구성하는 개별 기술뿐 아니라 이미 개발된 고효율 공조기 이용기술, 보온성 향상기술, 온도 관리 기술 등을 지역, 시설, 작목, 작형 등에 최적화하여 조합할 수 있는 추가적 패키지 모델의 개발 연구가 필요한 것으로 판단되었다.
본 연구는 공기열원 히트펌프 온실에서 환기에 의해 배출되는 에너지 즉 잉여 태양에너지 및 태양열 집열기를 이용하여 축열량 및 이들 에너지를 이용한 온실의 난방효과를 실험적으로 검토하였다. 태양열 집열기의 경우, 실험기간동안 누계 수평면 일사량의 최대, 평균 및 최솟값은 각각 52.2, 22.9 및 3.2 MJ․m-2이었고, 총 일사량은 869.8 MJ․m-2 정도였다. 그리고 집열량의 최대, 평균 및 최솟값은 각각 38,118.2, 22,545.9 및 2,622.1 kcal 정도였고, 총 집열량은 856,742.6 kcal 정도인 것으로 나타났다. 잉여 태양에너지의 경우, 여러 가지 요인에 의해서 온실로부터 회수되는 열량은 다르지만, 온실로부터 회수된 총 잉여 태양에너지는 375,946.7 kcal 정도인 것으로 나타났다. 히트펌프의 경우, 설정온도를 고려하지 않고 축열된 총 축열량은 17,519,085.3 kcal이고, 이 때 소비된 소비전력량은 7,169.6 kWh정도이었고, 시스템의 성능계수는 2.84정도이었다. 그리고 온실로 공급된 난방에너지는 최저 외기온과 유사한 경향을 보이는 것으로 나타났으며, 실험기간동안 총 난방에너지는 9,554,541.9 kcal로서 시간당으로 환산하면 평균 6,653.1 kcal․h-1정도인 것으로 나타났다. 특히 실제 히트펌프에 의해 축열된 량의 54.5%정도만 이용하는 것으로 나타나 난방시스템의 개선이 필요할 것으로 판단되었다. 실험기간동안 태양열 집열기, 잉여 태양에너지 및 히트펌프에 의한 축열량을 난방에너지로 100.0% 이용할 경우, 탄소배출량은 각각 259.7, 116.9 및 5,403.5 kgCO2정도 절감시킬 수 있을 것으로 나타났다.
Experimental hot-water heating system was consisted of power supply equipment, a hot water storage tank, circulating pump, fan coil unit and a plastic flexible hose. This heating system was manufactured by an electric heater of a power capacity 6kw/h and light-oil hot air heater in control the heating capacity was 5,000kcal/h. As the result, temperature difference due to hot-water heating system and hot air heater in greenhouse showed that air temperature at experimental greenhouse, and comparison greenhouse were 14.8℃, 13.4℃ respectively. It was found that root-zone temperature of experimental plot and control were 22℃, 15℃. Root-zone temperature in the experimental plot was 7℃ higher than that in control. The inlet-outlet water temperature difference of 2℃ and 3℃ corresponded to the difference of the heat exchange of about 3,132kcal/h, 4,916kcal/h, the heat exchange effciency ranged from 54~88% generally. Under the experimental condition, equation heat change(Y) and correlation could be represented as follows : Y = -282.92x2 + 2963.9x -1688.6, R2 = 0.9081. it is suggested to applicate energy of root-zone warming system where energy from the groundwater is extracted and transferred to the water
본 연구는 길이 15 m, 폭 5.6 m, 동고 2.9 m인 단동 비닐 온실 2동을 대상으로 실험구와 대조구로 나누어 실시하였다. 시스템은 전기히터를 이용한 온수가온기로서 온수저장조와 순환펌프, 팬코일유닛으로 구성하였다. 폐회로시스템의 온수배관을 통하여 온수가 순환되도록 하였으며 팬코일유닛을 통해 온실내부를 난방 하도록 하였다. 연구결과를 요약하면 다음과 같다. 실험기간 동안 순환유량은 26L/min 정도의 범위에 있었고, 평균유속은 2.0m/s 정도였다. 유출입수의 평균 온도차는 60±2℃ 이었다. 근권부 온도를 측정한 결과 처리구에는 22℃, 대조구에서는 15℃로 나타나 처리구 근권부 온도가 약 7℃ 높게 유지되었다. 입출구 온도차에 따른 열교환량은 온도차가 2℃일 경우 시간당 열교환량은 3,132kcal이고, 3.4℃일 경우 4,916kcal로서 열교환방정식은 y=-282.92X2+2963.9X-1688.6, R2=0.9081로 상관관계가 매우 높은 것으로 나타났으며 열교환효율은 54~88%로 온도차가 클수록 열교환효율은 높게 나타났다.
This carbon nano heating system was consisted of power supply equipment, a carbon fiber and a stainless flexible hose. carbon nano heating system was manufactured by carbon fiber of a power capacity 30kw/h and light-oil hot air heater in control plot was the heating capacity 30,000kcal/h, As the result, Temperature difference due to carbon nano heating system and hot air heater in greenhouse showed that air temperature at experimental greenhouse, comparison greenhouse were 14.8℃, 13.4℃ respectively. It was found that carbon nano heating system and light-oil hot air heater heating cost were 1,095,740won, 2,683,628won. therefore as heating cost saving 60%. Yield of tomatoes cultured in greenhouse using carbon nano heating pipe was 4% inclease. Economic analysis comparison between the carbon nano heating pipe and the hot air heater in greenhouse were 41% respectively.
경상대학교 농장 벤로형 유리온실(280m2)에 적외선등 난방 시스템을 설치하였다. 분식물 호접난, 홍콩야자나무, 무늬고무나무, 장미에 대한 적외선등 난방 시스템의 가 열효과를 알아보고자 열화상 카메라를 이용하여 온도 변화를 측정하였다. 그리고 난방의 효과를 적외선등 난방 시스템 ‘On’과 ‘Off’로 달리하여 실험을 수행하였고 적외 선등 난방 시스템의 경제성을 분석하였다. 온실 내부 설 정온도가 18oC일 때 식물체의 엽온도는 22.8~27oC, 화분 에 담겨 있는 배지의 온도는 21.3~24.3oC이었다. 관엽식 물과 같이 키가 큰 작물은 상부의 온도가 홍콩야자나무와 무늬고무나무 각각 24.0oC와 26.9oC로 가장 높았고, 아래 로 내려오면서 점점 온도가 내려가는 경향을 보였다. 열 화상 카메라를 이용한 온도 변화 관찰을 통하여 적외선등 난방 시스템을 이용한 온실내 작물의 가열 효과는 충분함 을 알 수 있었다. 장미의 경우 적외선등 난방 시스템을 이용한 난방의 경우 밤과 새벽 사이 외부 기온이 많이 떨어지는 시점에도 설정온도(18oC)에 가깝게 유지되고 있었다. 특히 ‘On’ 상태에서 근권부 평균온도는 21.8oC 이었고, 엽의 평균온도는 17.8oC이었다. ‘Off’ 상태의 경우 근권부 평균온도가 20.4oC이었고, 엽의 평균온도는 15.5oC 로 뚜렷한 차이를 보였다. 난방부하량은 약 24,850~ 35,830 kcal·h−1 정도로서 이 때 난방비를 경유로 환산 하면 약 27,000~40,000원 정도였다. 소비전력량과 전력요 금은 각각 330~560 kWh 및 8,600~14,800원 정도였다. 즉 전체적으로 단순비교해 볼 때, 적외선등 난방 시스템을 사용할 경우 경유 온수보일러에 비해 난방비용이 약 35% 정도 밖에 소요되지 않는 것을 알 수 있다. 적외선등 난방 시스템을 이용한 난방의 경우 야간 시간대에 공기온도가 설정온도 보다는 다소 낮게 유지되고 있음을 알 수 있다. 즉, 유리온실의 경우 밀폐성이 좋지 않아서 공기온도를 설정한 온도수준으로 유지되지 못하는 것으로 판단되어 향후 유리온실에서 적외선등 난방 시스템을 이용하는 경우 설치간격, 센서 부착위치 및 공기대류 등에 대한 연구가 더 필요하다고 생각된다.
To use effectively the solar energy in greenhouse heating, a high performance solar collector should be developed. And then the size of the solar collector and thermal storage tank should be determined through the calculation of heating load. The solar collector must be set in the optimum tilt angle and direction to take daily solar radiation maximally, and the flow rate of heat transfer fluid through the solar collector should be kept in the optimum range. In this research, the performance tests of a capillary tube solar collector were performed to determine the optimum water flow rate and the results summarized as follows. 1. The regressive equations for efficiency estimations of the capillary tube solar collector in the open loop were modeled in the water flow rate of 700-l,000 l/hr. 2. The optimum water flow rate of the solar collector was estimated by the second order polynomial regression and the maximum efficiency was 80% at the water flow rate of 850 l/hr. 3. The solar thermal storage system consisted of a capillary tube solar collector and a water storage tank was tested at the water flow rate of 850 l/hr in the closed loop, and obtained the solar thermal storage efficiency of 55.2%. 4. As the capillary tube solar collector engaged in this experiment was made of non-corrosive polyolefin tubes, its weight was as light as 1/30 of the flat plate solar collector made of copper tubes. Therefore it was considered to be suitable for the greenhouse heating system.