검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 13

        1.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, we break away from the method of removing and inspecting the GDI injector, measure the pressure change of the fuel rail pressure sensor when driving the GDI injector of a vehicle equipped with the GDI fuel system, and compare the results. analyzed.There was a pressure change in the fuel rail pressure sensor from the general drive GDI injector. There was no pressure change in the fuel rail pressure sensor when driving the GDI injector without injecting fuel. You can check the fuel injection status in the pressure change data of the fuel rail pressure sensor without removal the GDI injector.
        4,000원
        2.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In commercial vehicles. the pulsation noise when the power steering operating is the major item to make the complain for users. If this noise have related to vibration characteristics in steering system's parts or assembly, it makes the problem in vehicle quality. Recently, the users demand the high quality in commercial vehicles, and we must identified the relevance between the pulsation noise and the vibration characteristics. After the identification, we can design the power steering system for satisfaction the user’s needs. Finally, the identification of relevance in pulsation noise for analysing the vibration characteristics will be suggested advanced power steering system.
        4,000원
        3.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Fuel pump of a vehicle is a device to supply the fuel from fuel tank to engine. This study analyzed the pulsatility on the shape of fuel supply pipe using a CFD(Computational Fluid Dynamics). Numerical analysis was performed to use 3-dimensional incompressible k-ε turbulent model with measured pressure values at an exit by an experiment. Simulation models used commercial and improved model. In this study, the characteristics of the pulsatility reduced in improved model compared to those in commercial model. The pressure loss, which occurs at the flexure, was effective to pulsatile reduction. Commercial and improved model differed by numbers of flexure. The number of flexure between inlet and outlet decreased the difference of velocity and pressure. Therefore, the design of fuel supply pipe should be considered numbers and shape of flexure.
        4,000원
        4.
        2006.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to assess the effects of High-Voltage Pulsed Current (HVPC) and ultrasound on adjuvant-induced arthritis in rats. Adjuvant arthritis was induced in female Sprauge-Dawley rats by the subcutaneous injection of a single dose of 1 ㎖ of Complete Freund's Adjuvant (CFA) (1 mg of Mycobacterium Butyricum suspended in 1 ㎖ paraffin oil) into the right hind paw. A randomized, parallel-groups design of 24 subjects was used. All rats were randomly assigned to control (n=8), ultrasound (n=8), and HVPC (n=8) were compared with those of injured rats. The rats in the pulsed ultrasound group were treated at 1 MHz frequency with 5 W/㎠ intensity in 1:4 mode for 5 minutes per day. The rats in the HVPC group were treated at 120 pulses per second and 50 ㎲ phase duration, 20 mA intensity for 30 min per day. Treatment was done in the left and right hind limb for 2 weeks. We evaluated clinical, radiographic, hematologic and histopathologic findings before and after treatment and obtained the following results. 1. Edema of the right hind paw was more significantly reduced in the ultrasound and HVPC groups than the control group on days 9, 12, and 14 (p<.05). Edema of the left hind paw was more significantly reduced in ultrasound and HVPC groups than the control group on days 12, 14 (p<.05). 2. WBC counts of the ultrasound and HVPC groups as compared with the control group were becoming remarkably decreased after the treatment. 3. In radiologic findings, arthritis formation was seen according to the score of arthritis, which was the highest in the control group, upon the observation of radiographs of the left and right hind paws. However, no statistically significant difference was present in the score within three groups. 4. In the histopathologic findings, ultrasound and HVPC groups had effectively suppressed erosions of articular cartilage and inflammatory cell infiltrations. Therefore, the results of the study show that rats that were treated with the ultrasound and HVPC effectively suppressed adjuvant arthritis. However, no statistically significant difference was present between the ultrasound group and the HVPC group.
        4,000원
        5.
        2005.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to evaluate the effects of pulsed ultrasound on wound healing and observe during the wound healing process the distribution of mast cells according to histopathologic findings. Eighty Sprague Dawley rats which were divided into 4 groups received full thickness skin wounds on the back. Each of the 5 animals was sacrificed immediately and then sacrificed again 1, 3, 6, and 12 days after injury. Specimens from the wounds were removed during healing and routinely processed with a hematoxylin-eosin stain and a toluidine blue stain. The authors then observed the distribution of mast cells under a light microscope. The results of this study were as follows: The rate of wound healing and the length of the wounds of the pulsed ultrasound group II was significantly faster than group I on day 6 and day 12 (p<.001). Group III showed the most significant effect after12 days (p<.001). Group IV also showed a significant effect at 12 days (p<.01). A low-intensity ultrasound .5 resulted in a fast healing rate. During the wound healing process mast cells had a tendency to decrease in the acute inflammatory phase. During the wound healing process mast cells were thought to contribute to the healing of the wound.
        4,200원
        7.
        2002.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this research was to determine the effects on the healing of fibular fractures in rabbits of low-intensity pulsed ultrasound (50 and 500 ) applied for periods of 4, 14 and 24 days following fibular osteotomy. Thirty-six male Japanese white rabbits were randomly divided into three groups of twelve for three treatment protocols: (1) ultrasound treatment at intensities of 50 and 500 until the 4th day following fibular osteotomy, (2) ultrasound treatment at intensities of 50 and 500 until the 14th day following fibular osteotomy, and (3) ultrasound treatment at intensities of 50 and 500 until the 24th day following fibular osteotomy. The low-intensity pulsed ultrasound was applied to only one fibula of each rabbit (these served as the experimental group). The other fibula of each rabbit served as the control group. The selection of which fibula was to be treated was made randomly. The animals were sacrificed on the 4th, 14th and 24th day after the start of ultrasound treatments. Percent of trabecular bone area and fibular radiography were carried out to compare the degree of fibular bone healing. A microscope was also used to determine any histologic changes. For statistical differences in radiological changes due to length of treatment period (4, 14 and 24 days respectively), the Wilcoxon signed-ranks test was used to compare the experimental and control groups. For statistical differences in fracture healing due to differences in ultrasound intensity, radiological studies were compared using the Mann-Whitney Test. And, to compute percentage differences in areas of trabecular bone, Two-way analysis of variance (ultrasound intensity x each group) was used. Experiment results were as follows: 1. In animals sacrificed on the 4th day, no difference was found in the radiological studies of the fibulae in the experimental and control groups (p>.05). However, experimental groups showed more rapid bone repair than control group. 2. Both radiographic and percent of trabecular bone area studies showed significant differences in rabbits sacrificed after 14 days. Fracture healing was significantly increased in the experimental group (p<.05) 3. In the animals sacrificed on the 24th day, histologic study showed rapid bone repair but fibular radiologic studies did not show statistical differences between the two groups (p>.05). 4. On the 14th day, bone union on radiograph was significantly more rapid in the treatment group with pulsed ultrasound of 50 than the group with 500 (p<.05). Histologic studies showed that both the 14 and 24 days groups had more rapid bone repair in animals treated with 50 ultrasound intensity than those treated with 500 intensity. In conclusion, it has been shown that the low-intensity pulsed ultrasound has a positive effect on bone fracture healing in the early stage and the range of pulse ultrasound from 50 to 500 is effective for fracture healing. Further study is needed to investigate the influence of pulsed ultrasound on delayed union and non-union in bone fractures and also for the clinical use of low-intensity pulsed ultrasound for bone healing in humans.
        4,900원
        9.
        1999.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to determine whether high voltage pulsed current stimulation (HVPCS) would enhance wound healing in neuropathic rabbits. Ten rabbits were assigned to either an experimental or a control group. The wounded part around the peripheral neuropathy of the experimental rabbits was stimulated for two hours twice a day for six days under the following conditions: pulse frequency 80 pps, pulse duration , and stimulation intensity 30~40 V. The results indicated that there was no difference in the wound closure between the experimental and control groups. The two groups showed similar aspects in collagen and reticulum, which were observed by colored Masson's trichome. While the rabbits in the control group had more or less thick fibers, the rabbits in the experimental group had thin and branched-shape fibers. The rabbits in the experimental group showed both strong responses in the shaping of elastic fibers and the increased aspects in fibroblast when compared with the control group.
        4,000원
        10.
        1996.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was performed to assess the efficacy of high voltage pulsed galvanic current for the healing of wounds in rabbits. Skin wounds were created laterally on the flank of 12 domestic rabbits(). The wounds of each group were treated with an intensity of 170 V at a frequency of 70 pulses per second, which was applied for 30 minutes a day for 10 days. The experimental groups were randomly assigned to either EXP I (n=3), EXP II(n=3), EXP III(n=3) or control(n=3). Each group was stimulated under the following conditions : 1) EXP I (Negative polarity), 2) EXP II (Change in polarity, negative electrode stimulation during the first 3 days and then positive electrode stimulation from 4 to 10 days), 3) EXP III(Positive polarity), 4) control(No stimulation). An active electrode was placed over the wound and a dispersive electrode on the buttock. The rate of wound closure was compared with the original wound size, evaluated by a tracing film in each measurement period. Finally, on the wound in each group, skin tissue was excised for histological evaluation after treatment for 10 days. The results obtained are as follows : 1) It was found that the control group did not show a complete remodeling of epitherial layer and had a chronic inflammatory response. Judging from the irregularity of intercellular space and the loose alignment of connective tissue, these findings show that wound healing was delayed. 2) EXP I showed a significant bactericidal effect, but a moderate response of vasodilation. The rate of wound closure was slower when compared with EXP II, III. 3) EXP II showed a complete remodeling of epitherial layer and a positive repair of connective tissue. Its rate of wound closure was best when compared with the others. 4) EXP III had a slower rate of wound closure than EXP II, but judging from the greater proliferation of collagen fibers and the dense alignment of connective tissue, this positive electrode was very effective in the formation of neo - connective tissue.
        4,800원
        11.
        1996.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        High Voltage Pulsed Current Stimulation(HVPCS) and Microcurrent Electrical Neuromuscular Stimulation(MENS) have been used to promote the healing of decubitus ulcer and surgical wounds. The benefits of HVPCS and MENS are thought to include an inhibitive effect on bacterial growth. The purpose of this study was to compare the inhibitive effect of two different electrical stimulation techniques growth in vitro. Using agarose-based media, the two bacterial species Staphylococcus aureus, Esherichia coli - which are commonly isolated from open wounds were incubated in an incubator for 24 hours following exposure to HVPCS(400 V, 120 pps, ) and MENS(, 0.3 Hz). We then measured the zone of inhibition around each electrode. Both HVPCS and MENS produced an inhibitive effect on bacterial growth in this vitro study. However MENS was more effective than HVPCS.
        4,300원
        12.
        1993.12 구독 인증기관·개인회원 무료