In this study, a vibrating nozzle using the waste vibration energy of the compressor body was installed in the suction flow path to improve the efficiency of the compressor through the pre-compression. To this end, the behavior of the suction valve according to the vibrating nozzle and the mass flow rate of the refrigerant entering the compression chamber were numerically analyzed. The results showed that the mass flow rate increased proportionally as the angle of the vibration nozzle increased. Among the profile shapes of the vibration nozzle, the concave or straight shape showed the highest mass flow rate. Considering the ease of machining, the straight shape is more favorable. On the other hand, as the operating frequency and stroke of the vibration nozzle increased, the mass flow rate also increased proportionally. It can be seen that the largest nozzle angle, operating frequency, and stroke are favorable for pre-compression unless the suction flow is restricted.. In the future, it is necessary to apply the vibrating nozzle system to an actual compressor model to experimentally check the compressor's cooling power, compression work and EER.
Abstract The compressor of a refrigerator accounts for approximately 60-80% of the total energy consumption necessary for the refrigeration cycle. This study investigates the implementation of a pre-compression system featuring a vibrating nozzle, with the goal of enhancing the efficiency of a linear compressor. By utilizing this pre-compression system, the cooling capacity and efficiency of the compressor are expected to improve. The numerical results show that the pre-compression system leads to an improvement of approximately 1.7% in cooling capacity compared to the baseline model. Furthermore, an increase of approximately 0.1 in EER was observed, confirming the feasibility of incorporating a pre-compression system with a vibrating nozzle.
선박 및 해양구조물과 같은 대형 유한요소모델의 진동 특성을 평가하기 위해 고유치 해석 및 가진 주파수에 따른 응답 계산을 필수적으로 수행해야 한다. 하지만 이러한 해석들은 과도한 전산 장비와 계산 시간이 요구되어 고성능 해석 프로그램의 개발이 필요하다. 특히 선형연립방정식에서 발생하는 역행렬 계산 및 고유치 해석 시에는 상당한 전산 해석 시간이 발생하기 때문에 최신 고성능 라이브러리를 적용함으로써 이를 개선할 수 있다. 본 연구에서는 병렬식 선형연립방정식 계산 라이브러리인 PARDISO와 고성능 고유치 해석 라이 브러리인 ARPACK을 적용하여 빠르고 정확한 해석이 가능한 진동해석 프로그램을 개발하였다. 끝으로 개발된 해석 프로그램의 정확도와 효율성을 검증하기 위해 여러 선박해양공학 수치 예제를 사용하였고, 상용 유한요소 프로그램인 ABAQUS와의 결과 비교 검토를 통해 개발된 진동해석 프로그램의 신뢰성을 검증, 제시하였다.
본 논문에서는 실제 공연장을 예제 건물로 하여 공연장에 발생한 진동을 측정한 결과를 바탕으로 공연장 구조물의 안전성에 대해 해석적으로 평가하였다. 수치해석 프로그램은 MIDAS GEN을 사용하였으며, 바닥판은 합성효과를 고려하여 모델링 하였다. 해석결과 진동계측실험을 통해 구한 바닥판 고유진동수와 유사한 결과를 보였다. 또한 군중의 율동에 의한 동적하중을 시간이력해석으로 해석하여 진동계측 실험과 유사한 수준의 바닥판 가속도 응답을 확인하였다. 이 모델을 사용하여 예제 공연장의 최대관람인원인 400명의 집단율동 시 발생하는 상황에 대하여 분석하였다. 그 결과 기둥과 보의 가해지는 외력은 설계 내력을 하회하여 안전성에 문제없음을 확인하였다. 또한 공연 시 발생하는 수평방향 진동수준은 지진하중의 2% 수준으로 수직수평 모두 안전성에 문제가 없는 것을 확인하였다.
본 논문에서는 상부구조물과 진동대에서 측정된 가속도를 이용하여 구조물과 지반의 동적 상호작용을 고려한 진동대 시험을 수행하는 방법이 제안된다. 부분구조법을 기반으로 한 제안된 실험법은 상부구조물만을 실험체로 사용하고 지반모델에 대해서는 동적지반강성을 진동대 제어기에 반영하는 방법이다. 이 때, 실험부분인 상부구조물은 전체 구조물 지반계의 동적거동을 모사하기 위한 운동으로 진동대에 의해 가진된다. 먼저, 구조물 지반계의 운동방정식으로부터 유도된 수치 시뮬레이션 검증모델에 의해 제안된 방법의 타당성이 검증된다. 또한, 진동대의 전달함수를 고려한 시뮬레이션 모델로부터 진동대 시험에 의한 제안된 방법의 적용성이 수치 시뮬레이션에 의해 검증된다.
이 논문은 원호형 곡선보의 면외 자유진동에 관한 연구이다. 곡선보 요소의 동적 평형방정식에 Timoshenko 이론을 적용하여 원호형 곡선보의 자유진동을 지배하는 상미분방정식을 유도하고 이를 수치해석하여 고유진동수를 산출할 수 있는 개략해법 중 하나인 수치해석기법을 개발하였다. 수치해석기법에서 미분방정식의 수치적분은 Runge-Kutta method를 이용하였고, 고유진동수의 결정은 Regular-Falsi method를 이용하였다. 실제 수치해석예에서는 회전-회전보, 고정-고정보에 대하여 시행하고 고유진동수에 미치는 무차원 변수들의 영향을 고찰하였다.
실시간 그래픽스 응용에서 연체의 움직임을 효율적으로 생성하기 위해 다양한 방법이 제안되었다. 연 체 구성 요소들의 위상을 유지하기 위해서는 서로를 묶는 힘이 존재할 수밖에 없으며, 이는 강직도 (stiffness)로서 수치적분의 시간간격의 크기를 제한하고 효율성을 떨어트린다. 이를 해결하기 위해 시간간 격을 늘릴 수 있는 암시적 적분이 제안되었지만, 대규모 행렬이 포함된 선형시스템을 풀어야 해서 계산복 잡도가 크게 높아진다. 이 문제를 개선한 근사 기법들은 댐핑 효과의 증가와 정확성의 손실을 초래할 수 밖에 없다. 본 논문에서는 선형시스템을 풀지 않고도 안정성은 크게 높이기 위해 조화진동에 근거하여 스 프링 힘을 적분하고, 이를 근사 암시적 기법과 결합하여 안정성을 극대화 하는 방법을 제안한다. 이 기법 은 GPU를 통한 병렬화가 용이하여 거대한 규모를 가진 연체 객체의 움직임을 실시간에 생성할 수 있다.
In order to analyze the dynamic characteristics and seismic performance of electrical cabinet affected the earthquake, a preliminary study should be carry on to find the natural frequency of that, and it can be known that through shaking table test and finite element analysis. The purpose of this study is to developing regarding the numerical model by using finite element method for the natural frequency of electrical cabinet be influenced by earthquake and to verify its reliability in comparison with experimental data through shaking table test in the future.
The light rail transits, in theses days, are planed to be introduced in Korea. However, there are more and more problems regarding the noise and vibration from the trackway. In order to reduced the vibration and noise, various method have been applied. Among those methods, it is that one of the most effective ways is to apply the floating mat underneath the slab track. In this stud, a numerical modeling to calculate the effect of the floating mat is to be used as well as the performance of the floating track.
Interest in seismic performance evaluation is increased due to various earthquake in the world. Many studies about fragility analysis of structure are performing which is based on probability analysis of failure for infrastructures maintenance. In this study, probability of failure for a numerical model of prototype square-shape reinforced concrete column was calculated in accordance with amplitude of seismic ground motion. The numerical model was updated based on results from shake table tests. The probability of failure will be used for comparing with that for scaled models. The difference of fragilities from prototype and scaled model can be confirmed by the comparing in a further study.
High speed railway bridges should be strictly maintained due to its social importance. However, There are many problems to execute loading test for precision safety diagnosis. A numerical experiment with a numerical model which is updated for reflecting characteristics of an existing bridge can be useful for high speed railway bridge maintenance. Moreover, more efficient maintenance can be possible if only ambient vibration is needed for numerical model updating process. In this study, a numerical model updating process is introduced in which only ambient vibration is enough to execute the process. Also, the usability of updated numerical model is verified by comparing measured and analyzed acceleration.
Linear and nonlinear models are available to simulate the effect of mine blasting. And the results are changed by selection of each model. Plaxis 8.0, FLAC 4.0 are used in this study for simulating blasting pressure. These programs offer linear model and nonlinear model. Linear model can properly simulate loss of impact wave in plastic failure region based on comparison of site vibration measurement and numerical analysis iteratively.
하천정비 사업과 치수, 이수 목적의 하천시설물이 증가함에 따라 시설물의 구조적 문제로 인한 사회적 피해예방을 위해 유지관리에 대한 관심이 높아지고 있다. 특히, 하천시설물 중 수문의 경우 개폐시 시간적, 공간적 흐름 변화가 크기 때문에 진동이 유발될 수 있다. 진동 발생 시 균열, 휨, 누수 등 안정성 문제가 발생하며 발생된 진동수가 구조물의 고유진동수와 일치하게 될 경우에는 공명현상으로 인해 붕괴될 수 있다. 이러한 피해 발생 후에는 많은 복구비와 노력이 필요하기 때문에 사전예방에 더 중점을 두어 설계해야한다. 종래의 진동해석 방법은 유체와 구조물의 해석을 각각 수행한 후, 시간 순서에 따라 유체의 해석결과를 구조물 해석의 초기 및 경계 조건으로 사용하였다. 따라서 수문의 부분 개방에 따른 유체흐름 변화에 의한 동수역학적 하중과 구조 변형에 의한 유체 흐름의 변화와 같은 지속적이고 상호적인 과정이 고려되지 않아 부정확성을 내포하였다. 반면에 FSI(Fluid-Structure Interaction) 분석은 유체와 구조물간의 상호작용을 시간과 공간에 있어 동시에 분석할 수 있어 이러한 부정확성을 감소시킬 수 있을 것으로 판단된다. 본 연구에서는 기존에 수리모형 실험 결과가 있는 Radial Sluice gate를 선정하였으며 수리모형실험과의 비교를 통해 FSI 분석의 적용성을 검토하였다. 수치모형으로는 FSI 해석이 가능한 CFX를 이용하였으며 수문의 개방비율에 따른 구조물의 변위를 분석하여 진동수를 산정하였다. 그 결과 진동해석에 FSI를 적용하는 것이 적합함을 확인하였고 수리모형 실험 결과와 전체적인 경향이 유사하다고 판단하였다. 추후 수문의 개방비율 뿐만 아니라 개폐중에 발생하는 진동수 변화에 대해서도 해석한다면 수문 운영에 따른 진동안정성을 검토하는데 중요한 자료로 활용될 수 있을 것이다.