An experimental study was conducted to examine for the structural behavior of coupled steel plate shear wall (Coupled SPSW) system what is formed by connection the two steel plate shear walls (SPSW) with a coupling beam. The variable of this study was the length of coupling beam. The testing results were showed that the strength and stiffness of specimen with shorter coupling beam were improved than those of other specimen. However there is no difference of the yielding mechanism.
The coupling beam is recognized that critical structural elements, those whose yield strength is likely to be exceeded in the event of a severe earthquake, should be designed and detailed to exhibit large ductilities and stable hysteretic loop. As a result, the alternation reinforcement details of reinforced concrete coupling beam was investigated.
This paper addresses the shear strength based on ACI 318-88 code and proposed equation by Park & Yun for steel fiber coupling beams containing steel fiber.
Based on the study of chloride migration coefficient and hydration heat evolution, it was found that the use of ternary blended cement was effective to achieve desired service life and minimum crack index. On the other hand, a high level of compressive strength is required for marine concrete mix design.
This paper addresses failure modes of steel fiber coupling beams containing steel fiber. It shows that steel fiber of coupling beams efficiently controlled increase of crack width by bridge action.
This paper addresses analysis using vector2 program of steel fiber coupling beams containing steel fiber. It shows that steel fiber of coupling beams efficiently controlled increase of crack width by bridge action.
For coupled shear walls, coupling beams are the first line of dissipation under earthquakes. So coupling beams are important energy dissipation component. When coupling beams have little depth-to-span ratio, routine coupling beams have less capacity of energy dissipation.There are less design methods for coupling beams with depth-to-span less than 2. In this paper a specimen with steel plate reinforcement coupling beam was designed and analyzed by means of FEM software ABAQUS.
The objective of this study is to investigate the influence of PVA Fiber on flexural yielding coupling beam. Test variable of this study is material type of coupling beam. Test results showed that coupling beam with PVA material experienced multiple micro craks.
Reinforced concrete coupled shear wall systems in medium and high-rise construction, where RC beams couple two or more RC walls have been frequently used. The objective of this study is to investigate seismic performance of coupling beam with headed bar.
The coupling beams provide transfer of vertical forces between adjacent shear walls in coupled shear wall system, which creates a frame-like coupling action that resists lots of the total overturning moment induced by the wind load or seismic load. The purpose of this study is to investigate the strain characteristics performance of coupling beams with headed bar.
The objective of this study is to investigate the failure modes of steel coupling beam-wall connection. Test variable of this study is types of material used, concrete and with pseudo strain hardening cementitious composites (PSH2C). The results showed that Specimen PSH2C-SB with longer embedment length of steel coupling beam exhibits good seismic performance than Specimen HCWS-SB.
초고층 건물의 주된 횡력 저항 시스템으로 사용되는 커플링보는 면내방향에 대한 하중을 고려하여 설계하는 것이 일반적인 경우이다. 하지만 장경간 구조물 혹은 비정형 구조물에서는 커플링보에 면내방향의 축력, 전단력 그리고 휨모멘트와 더불어 면외방향의 비틀림 모멘트가 작용하게 된다. 커플링보 길이가 짧고 비틀림 모멘트 하중이 작을 경우에는 수평철근 및 스터럽의 배근에 의해 설계가 되는 경우도 있지만 그 값이 클 경우에는 사용성(균열) 부분을 위해서라도 정밀 구조 해석이 필요하게 된다. 이에 대해 슬래브 강성 효과를 고려하여 커플링보 설계를 하는 것은 반드시 필요하다. 따라서 이 연구에서는 슬래브 강성을 고려한 RC 커플링보의 비틀림과 전단력에 대한 거동 및 구조 성능을 규명하고자 하였다.
구조물에서 커플링보의 위치는 코어 중심부와 코어 가장자리부로 나누어 볼 수 있다. 지금까지 커플링보의 연구에서 코어 가장자리부에 대한 연구 성과는 적은 것으로 나타났다. 코어 가장자리부의 SRC 커플링보 설치 방법에는 벽체에 철골기둥을 설치하는 경우와 설치하지 않는 경우가 있다. 그리고 철골기둥의 설치 이유는 커플링보가 양단에 모멘트 접합으로 충분한 강성을 필요로 하는 경우와 시공시 SRC 커플링보의 벽체 고정 작업을 편리하게 하기 위한 것이다. 오늘날 많은 현장에서 사용되고 있지만 이에 대한 연구가 미흡한 것이 사실이다. 또한 플렛 플레이트 구조물에서 사용되는 커플링보는 정확한 구조 성능 분석과 경제성을 위해 슬래브 강성 효과를 고려하는 것이 필요하다. 따라서 이 연구에서는 플렛 플레이트 구조물의 슬래브 강성을 고려한 코어 가장자리에 놓인 SRC 커플링보의 철골기둥 영향에 대한 거동 및 구조 성능을 규명하고자 하였다.
오늘날 층고 절감과 다양한 평면을 위해 플렛 플레이트 구조시스템의 사용이 증가하고 있다. 최근의 건물의 고층화와 층고제약 등으로 커플링보의 춤은 줄어들고, 요구 성능은 오히려 높아지고 있어서, 일반 형태로는 요구 성능을 만족시키기 어려운 실정이다. 따라서 커플링보의 슬래브 강성을 고려한 연구가 관심을 갖게 되었고 지속적인 연구성과가 나오고 있다. 하지만 기둥과 보의 강성에 의해 저항하는 라멘구조에서의 커플링보와 슬래브의 두께 및 유효폭에 맞춰 연구를 하였다. 따라서 슬래브 부분에서는 작은 변형에 의해 크랙이 발생하게 되고 이 원인으로 슬래브 강성 효과는 초기에 없어지는 것으로 나타났다. 하지만 검토 결과, 플렛플레이트 구조물에서의 커플링보에 대한 슬래브 강성비는 일반 라멘구조물과는 명확히 차이가 있다. 또한 코어 가장자리에 놓이는 커플링보는 일반적으로 모멘트 접합이 아닌 핀 접합으로 설계를 하게 되지만 슬래브 강성을 고려하여 구조적 거동을 명확히 분석하는 것이 필요한 것으로 판단된다. 따라서 이 연구에서는 플렛 플레이트 구조물의 슬래브 강성을 고려한 코어 가장자리에 놓인 RC, SRC 커플링보의 거동 및 구조 성능을 규명하고자 하였다.
최근의 건물의 고층화와 층고제약 등으로 커플리보의 춤은 줄어들고, 요구성능은 오히려 높아지고 있어서, 일반형태로는 요구성능을 만족시키기 어려운 실정이다. 이에 대한 대안으로 여러 가지 방법들이 연구되어지고 있으나, 구조기준과 이론적인 배경이 정립되어 있지 못하여 설계자가 적용하기에는 많은 어려움이 있다. 이 연구에서는 플렛 플레이트 구조물에서 사용되는 RC, SRC 커플링보 및 슬래브 두께를 조사하고 현실과 유사하게 유한요소해석 프로그램을 적용하여 슬래브 강성 효과를 고려한 커플링보의 구조 성능을 규명하고자 한다.