Cu-Ti thin films were fabricated using a combinatorial sputtering system to realize highly sensitive surface acoustic wave (SAW) devices. The Cu-Ti sample library was grown with various chemical compositions and electrical resistivity, providing important information for selecting the most suitable materials for SAW devices. Considering that acoustic waves generated from piezoelectric materials are significantly affected by the resistivity and density of interdigital transducer (IDT) electrodes, three types of Cu-Ti thin films with different Cu contents were fabricated. The thickness of the Cu-Ti thin films used in the SAW-IDT electrode was fixed at 150 nm. As the Cu content of the Cu-Ti films was increased from 31.2 to 71.3 at%, the resistivity decreased from 10.5 to 5.8 × 10-5 ohm-cm, and the density increased from 5.5 to 7.3 g/cm3, respectively. A SAW device composed of Cu-Ti IDT electrodes resonated at exactly 143 MHz without frequency shifts, but the full width at half maximum (FWHM) values of the resonant frequency gradually increased as the Cu content increased. This means that although the increase in Cu content in the Cu-Ti thin film helps to improve the electrical properties of the IDT electrode, the increased density of the IDT electrode deteriorates the acoustic performance of SAW devices.
The acoustic emission (AE) method as a passive non-destructive monitoring technique is proposed for real-time monitoring of mechanical degradation in underground structures, such as deep geological disposal of high-level nuclear waste (HLW). This study investigates the low-frequency characteristics of AE signals emitted during the fracturing of meter-scale concrete specimens; uniaxial compression tests (UCT) in a lab scale and Goodman jack (GJ) tests in a 1.3 m-long concrete block were conducted while acquiring the AE signals using low-frequency AE sensors. The results indicate a sharp increase in AE energy emission at approximately 60% and 80% of the yield stresses in the UCT and GJ tests, respectively. The collected AE signals were primarily found in two frequency bands: the 4-28 kHz range and the 56-80 kHz range. High-frequency AE signals were captured more as the stress increased in the GJ tests, which was in contrast to the UCT tests. Furthermore, the AE signals obtained from the Goodman jack tests tended to lower RA values than the UCT results. This study presents unique experimental data with low-frequency AE sensors under different loading conditions, which provides insights into field-scale AE monitoring practices.
위험유해물질은 해양에 유입되었을 때 인간의 건강 및 해양생태계에 막대한 영향을 미치는 물질로 정의된다. 최근 선박을 이용한 물동량이 증가되면서 위험유해물질 누출사고의 발생비율도 증가되는 추세이다. 이에 따라 위험유해물질 누출사고 대응기술개발의 관점에서 해저에 침적되는 물질들의 방제 및 모니터링 연구가 수행되어야 한다. 본 논문에서는 저층 침적 위험유해물질의 음향 탐지 가능성을 확인하기 위해 저층 침적 위험유해물질 대체물질의 반사손실 측정 실험이 수행되었다. 위험유해물질로 구분되는 클로로폼의 위험성을 고려하여 클로로폼과 임피던스가 유사한 피마자유가 대체물질로 사용되었으며, 200 kHz 고주파 신호를 송신하여 물과 피마자유 경 계면에서 발생되는 반사손실을 측정하였다. 그리고 물과 피마자유의 임피던스를 측정 및 조사하여 반사계수를 모의하고 모의된 반사손실이 측정값과 유사함을 확인하였다. 또한 저층 침적 위험유해물질로 분류되는 클로로폼의 반사손실을 모의하고 모의 결과가 다양한 해저면 구성성분의 반사손실 모의결과와 차이를 나타냄으로써 해저면과 구분되는 저층 침적 위험유해물질의 음향 탐지 가능성을 예측하였다.
Target strength (TS) information is an important parameter that estimates the detection, distribution, and abundance of Aurelia aurita. In order to investigate the biological TS of jellyfish, some factors such as size (bell diameter), tilt angle, pulsation, and symbion should be known. In the ex situ TS measurements, the tilt angles and pulsation from synchronized swimming behavior of four live A. aurita (bell diameters in the air: 54.2 ~ 94.2 mm) were measured with the acoustic data at 70 kHz. The reduced target strength (RTS) of A. aurita was found to change ranged from 13.4 ~ 16.5 dB according to the incidence angles from –30° to 24°. When the change rate of bell diameter in the water was 0.2, the TS value showed a 7.2 dB change. These results could be utilized as an important data to understand the acoustic characteristic scattering of A. aurita.
This study deals with the high frequency induction hardening (HF at 850℃, 120kHz & 50kW condition) SM45C steel. (1) The HF specimen, which was tempered at 150℃, did not show any tempering effect. A brittle fracture occurred at rounded area of the tensile specimen. AE (acoustic emission) amplitude distribution showed between 45dB and 60dB. (2) A slip and fracture occurred at the hole area of the HF specimen which was tempered at 300℃. As they pass the yield point, the AE energy is increased intermittently and AE amplitude distribution exists between 70dB and 85dB. In addition, after imposing the maximum tensile load, AE signals showed high amplitude and energy distribution. The AE amplitude showed between 45dB and 70dB. (3) A brittle fracture occurred at HF specimen which was tempered at 450℃ as if it is torn in the direction of 45° on parallel area over the both sides of the tensile specimen, which lead to several peak appeared in AE energy. It was found that the AE amplitude was relatively low and the AE energy was high.
This study is deal with the high frequency induction hardening (HF at 850℃, 120kHz & 50kW condition) SM45C steel. (1) The HF specimen which was tempered at 150℃, did not appear any tempering effect. A brittle fracture occurred at rounded area of the tensile specimen. AE amplitude distribution showed between 45~60dB. (2) The HF specimen which was tempered at 300℃, slip and fracture occurred at the hole area of the tensile specimen. As it passes the yield point, the AE energy increased intermittently and AE amplitude distribution showed between 70~85dB. In addition, after the maximum tensile load, it showed high amplitude and energy distribution. The AE amplitude showed between 45~70dB. (3) The HF specimen which was tempered at 450℃, a brittle fracture occurred as if it is torn in the direction of 45℃ on parallel area over the both sides of the tensile specimen, which led to several peak to be appeared in AE energy. It was found that the AE amplitude was relatively low and the AE energy was high.
Dual frequency acoustic pinger(AP) was manufactured to reduce study effect by long-term use of developed single frequency AP to prevent cetacean bycatch. Directivity characteristic of transducer was the omnidirectional pattern which showed less than ±3dB the change range of sensitivity on the beam pattern of right and left. Source power level(SPL) was 1384311pa with epoxy window before casing however after casing 1170B11Pa at sea. Dual frequency Af was tested to identify the avoidance behavior of bottlenose dolphin by its working. However the efficiency of dual frequency AP about the study effect was verified experiment repeatedly using single and dual frequency AP.
A low frequency, high power hydroacoustic transducer with 7 tonpilz piston elements assembled in a circular array suitable for marine application, such as the transmission of underwater information and the development of new fisheries resources in the deep sea zone was designed. A modified Mason's model was applied to monitor and to simulate the transducer behavior at each step during the fabrication. The in air, and in water constructed tonpilz transducer was tested experimentally and numerically by changing the size and the type of the material for head, tail and acoustic window. Also, the developed transducer was excited by pulse signals and the received waveform was analyzed. The resonance peaks in the transmitting voltage response(TVR) of a single tonpilz element without housing were observed at 11.33kHz in air and 10.93kHz in air and 10.93 kHz in water, respectively, with the overall electrical-acoustic efficiency of 43.7%. The value of TVR of single tonpilz element with aluminum housing in water was 129.87dB re 1 μPa/V at 12.25 kHz with the frequency bandwith of 2.15 kHz and half beam angle of 30.2˚at -3dB.The resonance peaks in the transmitting voltage response of the 7 element circular transducer were observed at 11.50 kHz in air and 11.45 kHz in water, respectively. The value of TVR in water 144.84 dB re 1μPa/V at 11.5kHz with the frequency bandwith of 4.25 kHz and the half beam angle of 22.3˚ at -3dB.Reasonable agreement between the experimental measurements and the theoretical predictions for the directivity patterns, TVRs and the impedance characteristics of the designed transducer was achieved.
본 연구에서는 국내 기술로 개수로 흐름 측정에 활용할 수 있는 초음파 유속 프로파일러를 개발하였다. 이 유속 프로파일러는 초음파의 도플러 효과로 유속을 측정하는 원리에 기반을 두고 있으며, 도플러 주파수는 펄스반복주파수(Pulse Repetition Frequency) 기법에 의해 산정된다. 개발된 유속 프로파일러의 성능을 검증하기 위해 실내 실험 및 현장 테스트를 수행하였다. 실험 결과 개발된 유속 프로파일러는 바닥에서부터 약 0.1 cm 이상의 수심