This paper is presented an experimental studies on bond stress between steel and concrete in concrete filled steel tubes. In the actual building frames, vertical dead and live loads on beams are usually transferred to columns by beam-to-column connections. In case when concrete filled steel tubes are used as columns of an actual building frame which has a simple connection, shear forces in the beam ends are not directly transferred to the concrete core but directly to the steel tube. Provided that the bond effect between steel tube and concrete core should not be expected, none of the end shear in the beams would be transferred to the concrete core but only to the steel tube. Therefore, it is important to investigate the bond strength between steel tube and concrete core in the absence of shear connectors.
In this study, compressive tests were carried out on seamless circular tubular short columns with corrosion-damaged end, and investigated change in compressive strength of columns with local corrosion at the end. Local corrosion was artificially introduced by milling machine, and differed in corrosion depth (0, 1.5, 3, 4.5 mm), corrosion height (0, 20, 60, 120 mm), and corrosion circumference (0, 90, 180, 360˚ ). As a result, the compressive loads were linearly decreased with increasing of corrosion degrees, and a quantitative evaluation for residual compressive strength of seamless circular tubular short column with corrosion-damaged end was suggested by using corroded volume loss ratio.
Eight small scale circular reinforced concrete columns were tested under cyclic lateral load with 4.5 aspect ratio. The test variables are longitudinal steel ratio, transverse steel ratio, and axial load ratio. Eight flexurally dominated columns were tested. In all specimens, initial flexural-shear cracks occurred at 1.5% drift ratio. The multiple flexural-shear crack width and length gradually increased until the final stage. The angles of the major inclined cracks measured from the vertical column axis ranged between 40 and 48 degrees. In particular, this study focused on assessing transverse reinforcement contribution to the column shear strength. Transverse reinforcement contribution measured during test. Each three components of transverse reinforcement contribution, axial force contribution and concrete contribution were investigated and compared.
형상비(M/VD, shear span-depth ratio)가 4.5인 축소모형의 원형기둥 실험체 3개를 제작하였다. 철근콘크리트 기둥 실험체의 단면 은 원형이고 중공단면으로 제작되었다. 철근콘크리트 기둥 실험체의 단면 지름은 400 mm, 중공 지름은 200 mm이다. 일정한 축력 하에서 반복 하중을 가력하는 준정적 실험을 수행하였다. 실험체의 주요변수는 횡방향철근비이다. 모든 실험체의 횡방향 나선철근 체적비는 소성힌지 구 간에서 0.302~0.604%의 값을 갖는다. 이 값은 도로교설계기준에서 요구하는 최소 심부구속철근 요구량의 45.9~91.8%에 해당하며, 이는 내진 설계가 되지 않은 기존 교각이나 내진설계개념으로 설계되는 교각을 나타낸다. 본 연구의 최종목적은 실험적 기초자료의 제공과 함께 성능단 계별 균열거동, 하중-변위 이력곡선, 에너지 소산 능력, 등가점성감쇠비, 잔류변형, 유효강성 등 내진성능의 정량적 수치와 경향을 제공하기 위 한 것이다. 본 논문에서는 실험결과를 통해 분석된 실험변수에 따른 실험결과들을 공칭강도, 비선형 모멘트-곡률 해석 결과, AASHTO LRFD 및 도로교설계기준(한계상태설계법)과 같은 기준들과 비교하였다.
형상비(M/VD, shear span-depth ratio)가 4.5인 축소모형의 원형기둥 실험체 3개를 제작하였다. 철근콘크리트 기둥 실험체의 단면 은 원형이고 중공단면으로 제작되었다. 철근콘크리트 기둥 실험체의 단면 지름은 400 mm, 중공 지름은 200 mm이다. 일정한 축력 하에서 반복 하중을 가력하는 준정적 실험을 수행하였다. 실험체의 주요변수는 횡방향철근비이다. 모든 실험체의 횡방향 나선철근 체적비는 소성힌지 구 간에서 0.302~0.604%의 값을 갖는다. 이 값은 도로교설계기준에서 요구하는 최소 심부구속철근 요구량의 45.9~91.8%에 해당하며, 이는 내진 설계가 되지 않은 기존 교각이나 내진설계개념으로 설계되는 교각을 나타낸다. 본 연구의 최종목적은 실험적 기초자료의 제공과 함께 성능단 계별 균열, 철근의 항복, 파단 등 정량적 수치와 경향을 제공하기 위한 것이다. 본 논문에서는 실험결과를 통해 분석된 실험변수에 따른 교각의 파괴거동, 강도저감거동, 변위연성도에 대해 중점적으로 기술하였다.
최근 도심지에 건설되는 건축물의 초고층화는 기둥에 작용하는 하중을 증가시켜 기둥단면 증가와 사용면적 확보의 어려움을 발생 시키고 있다. 이에 최근에는 CFT와 같은 합성기둥의 사용이 증가하고 있는 추세이다. 그러나 CFT 기둥의 경우 폐단면으로 이루어져 있어 보- 기둥 접합부 개발의 어려움과 성능저하의 문제가 발생하게 된다. 특히, 원형CFT 기둥과 외다이아프램을 이용한 접합상세 개발의 연구가 미비 한 실정이다. 이에 본 연구에서는 Y형 플레이트를 적용한 원형 CFT 기둥-H형강 보 접합부 접합상세를 개발하여 Y형 플레이트를 적용한 접합 부 구조성능에 영향을 미치는 Y형 플레이트 폭 및 두께를 주요변수로 설정하여 실험을 통해 구조성능을 평가하였다. 또한 실험체에 사용된 Y 형 플레이트는 설계기준에 제시된 장기허용인장력이 Y형 플레이트에 접합된 인장 측 플랜지의 축방향력 이하가 되도록 설계하여 파괴형태를 통해 Y형 플레이트의 구조적 안전성과 성능을 확인하고자 한다.
Transverse reinforcement in reinforced concrete column can improve strength and ductility by confining column to expend laterally. The effects of enhancement of strength and ductility depend on the degree of confinement on transverse reinforcement. The theoretical equations about confinement effects of reinforcement concrete column were proposed by earlier investigators. In this study, it was identify the factor for significant impact on reinforced concrete circle column based on early models, and Parameter studies was carried out by each factor. Parameter studies decide the major variables for vertical interval and yield strength of transverse reinforcement, compressive strength of concrete, and sectional area. In Parameter study results, it was identify that vertical interval of transverse reinforcement is significant impact on the strength and ductility.
The result of structural performance evaluation about circular CFT column-H shape steel beam which was performed as in previous study, even though we designed the Y type plate tension as below the axial force which was under design criteria, the flexure of steel beam was happened. For these reasons, in this study, to figure out the time of connections failure and the minimum value of parameters in order to evaluate the performance of advanced Y type plate in detail.
Eight small scale circular reinforced concrete columns were tested under cyclic lateral load with constant axial load. Test specimens were designed with 4.5 aspect ratio. The selected test variables are longitudinal steel ratio, transverse steel ratio, yielding strength of longitudinal steel and axial load ratio. The test results of columns with different longitudinal steel ratio, transverse steel ratio and axial load ratio showed different seismic performance such as equivalent damping ratio, residual displacement and effective stiffness. It was found that the column with low strength of longitudinal steel showed significantly reduced seismic performance, especially for equivalent damping ratio and residual displacement. The regulation of flexural over-strength is adopted by Korea Bridge Design Specifications (Limited state design, 2012). The test results are compared with nominal strength, result of nonlinear moment-curvature analysis and the design specifications such as AASHTO LRFD and Korea Bridge Design Specifications (Limited state design).
형상비 4.5인 축소모형 원형기둥 실험체 8개를 제작하여 일정한 축력 하에서 반복횡하중을 가력하는 실험을 수행하였다. 실험체의 주요변수는 횡방향철근비, 축방향철근비 (2.017%, 3.161%), 축력비 (0, 0.07, 0.15)이다. 모든 실험체의 횡방향 나선철근 체적비는 소성힌지 구간에서 0.3352~0.8938%의 값을 갖는다. 이 값은 도로교설계기준에서 요구하는 최소 심부구속철근 요구량의 39.7~122.3%에 해당하며, 이는 내진설계가 되지 않은 기존 교각이나 내진설계개념으로 설계되는 교각을 나타낸다. 본 연구의 최종목적은 실험적 기초자료의 제공과 함께 성능단계별 균열, 철근의 항복, 파단 등 정량적 수치와 경향을 제공하기 위한 것이다. 본 논문에서는 실험결과를 통해 분석된 실험변수에 따른 교각의 파괴거동, 강도저감거동, 변위연성도에 대해 중점적으로 기술하였다.
원형 강합성 중공 철근 콘크리트 기둥은 중공 철근 콘크리트 기둥의 내부에 튜브를 보강하여 코어 콘크리트를 3축 구속 상태를 만들어 주어 강도, 강성, 연성도를 향상 시킨 매우 성능이 우수한 기둥이다. 본 기둥을 교량의 하부구조에 적용하기 위해서는 횡방향 철근량 및 종방향 철근량의 기준을 제시하는 것이 필요하다. 교각에서는 횡방향 하중에 저항하기 위하여 소성힌지 부분에 심부 구속 횡방향 철근을 배근하여 구속 효과를 증대시키고 있다. 이것은 심부 구속 횡방향 철근 배근을 통하여 교각에 필요한 강성 및 연성을 확보하여 내진성능을 향상 시킨다. 철근 콘크리트 기둥의 심부 구속 횡방향 철근량을 산정하는 방법은 국내의 도로교 설계 기준과 국외의 대다수 설계 기준이 동일하다. 이 설계식을 원형 강합성 중공 철근 콘크리트 기둥에 적용하기에는 그 구성 요소가 상이하고 거동 특성이 다르기 때문에 새로운 방법이 적용되어야 할 것으로 판단된다. 본 연구에서는 현행 기준을 적용하였을 때를 분석하였고 이때에 연성도에 영향을 미치는 인자를 도출한 후 이를 이용하여 합리적인 수정식을 제안하였다.
본 연구에서는 카본시트튜브로 구속된 원형기둥에 반복 횡하중을 가하여 기둥의 휨내력을 평가하는 실험을 수행하였다 중립축을 기준으로 압축 및 인장측 단면의 모멘트를 이용하여 공칭모멘트를 계산하는 등가응력블록계산법을 소개하였다 또한 실험결과를 분석하여 횡 하중에 대한 거동을 예측할 수 있는 회귀식을 마련하여 실험결과와 비교하였다