검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 13

        5.
        2016.11 구독 인증기관·개인회원 무료
        본 연구에서는 한외여과 막을 사용하여 대장균 단독, 대장균 및 Bacillus subtil is 균을 혼합액을 대상으로 제거 효과를 고찰하였으며, 아울러 kaolin, CaCO3 및 urea와 같은 탁도 유발 성분들과 대장균 단독, 대장균 및 Bacillus subtilis 균과의 혼합액에서의 상호작용을 검토하고자 pH 변화, 탁도 제거 효율, urea, kaolin, Ca CO3 제거 효율, 대장균 군 및 Bacillus subtilis 균의 제거 효과를 고찰하였다.
        6.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To evaluate the performance of a new automated coliform enumeration system (TEMPO® CC) for the quantitative test of coliform bacteria contaminated in domestic livestock processed foods, a total of 507 samples of livestock foods were tested by the TEMPO® CC method, the most probable number (MPN) method, and Petrifilm method, respectively. The results of those three methods were compared to each other. Of 507 samples of livestock processed foods used in this study, 217 samples were contaminated artificially with coliform bacteria and the rest (n=290) were contaminated naturally. The results of the TEMPO® CC method for all samples were equivalent to those obtained from the MPN method, except 8 samples. In addition, 496 (97.8%) out of 507 samples made agreement between the TEMPO® CC method and the Petrifilm method. The correlation coefficients between TEMPO® CC and MPN methods as well as between TEMPO® CC method and Petrifilm method were above 0.9, and the slope and intercept of the linear regression model was different in less than 1 value. In conclusion, there were statistically equivalent levels of performance between the TEMPO® CC and the reference and alternative methods for the enumeration of coliform bacteria in livestock processed foods in this study.
        4,000원
        7.
        2009.02 구독 인증기관 무료, 개인회원 유료
        In this study, disinfection effect of coliform group treated with ozone was analyzed for the effluent discharging from activated sludge treatment process in hospital wastewater treatment plant. Based on these results, it aims to get basic data to establish the disinfection facility in hospital wastewater treatment, suggesting affecting factors according to hydraulic retention time of the activated sludge process and design basic factors necessary to ozone disinfection. Removal efficiencies of coliform group for the effluent according to HRT such as 4hr, 8hr, 12hr were analyzed using a lab-scale activated sludge process, respectively. To decay the microorganism regulates the CT value multiplied disinfectant concentration by contact time. CT value is highly correlated with a removal efficiency of coliform group and according to increasing an injected ozone concentration, the CT value was increased.. When HRT was 4, 8, 12 hours , CT value takes place at minimum condition 50, 40, 334 mg/L-min, respectively.
        5,100원
        8.
        1999.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The number of viable microorganism in drinking water was monitored according to storage temperature and storage period. The number of general bacteria in underground water was 10²-10^5CFU/ml and that of coliform group was decreased after 7days. The number of general bacteria in bottle water was increased until 7days but decreased after that day. Coliform group in bottle water were detected only 1 sample. The number of general bacteria in purified water was 10³-10⁴CFU/ml and 10²-10⁴CFU/ml at 8 and 25, respectively. Coliform group were not detected in purified water.
        3,000원
        9.
        1997.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A study was conducted to determine contamination status of fish sold at wholesale market in Seoul. A total of 79 samples (35 different kindry fish) were collected from the wholesale market. E. coli and coliform group bacteria were cultured and tested for sensitivity against antibiotics. The results are summarized as follows; 1. E. coli was isolated from 23 out of 79 samples (29.1%), and coliform groups from 53 out of 79 (67.1%). 2. Of coliform group, Citrobacter freundii was the most common and Enterobacter cloacae was the next. 3. 23 E. coli strains isolated from fishes were resistant to Oxacillin, Erythromycin and Lincomycin, meanwhile 23 E. coli strains were sensitive to Cefoperazone, Ceftazidime, Imipenem, and Ciprofloxacin.
        4,000원
        12.
        2008.07 KCI 등재 서비스 종료(열람 제한)
        Using high voltage electric fields induced by high voltage AC (10-12 kV/cm, 20 kHz) and pulsed (20-30 kV/cm, 40 Hz) electric field generator as a semipermanent and environment-friendly disinfecting apparatus, the disinfection effect of coliform group in the effluent of sewage plant was investigated. The effects of electric field strength, treatment time, discharge area of a discharge tube, water quality factors (electric conductivity, pH and SS) on its death rate were examined. The death rate of coliform group was increased with increasing electric field strength and treatment time. For AC and pulsed electric field generator, the critical electric field strength was 6 kV/cm and 2 kV/cm, respectively, and the critical treatment time was 5 min and 2 min, respectively, regardless of electric field strength. Comparing the death rate of coliform group by AC and pulsed electric fields used in this study, its death rate was higher for the latter than the former, but did not increase linearly with increasing electric field strength. The results obtained for the effects of discharge area, electric conductivity, pH and SS on the death rate of coliform group using AC electric field (12 kV/cm, 20 kHz) were as follows: its death rate showed the trend to increase linearly with increasing discharge area; for the effect of electric conductivity, its death rate was increased with increasing electric conductivity, regardless of ionic species, increased with increasing cationic valency, but was similar between the same cationic valency; the pH 5~9 used in this study did not affect its death rate; its death rate was decreased with increasing SS concentration.
        13.
        2006.06 KCI 등재 서비스 종료(열람 제한)
        The experiment was carried out to determine the distribution of total coliform the translocation of heavy metals and the salt accumulation in soils following the supply of ground water, the domestic wastewater and the ultraviolet treatment of domestic wastewater during the spinach and the chinese cabbage cultivation. There were not much changes in the Total-N, Total-P and cations in soils following the ultraviolet treatment of the domestic wastewater. However, the density of total coliform was dramatically reduced from 894MPN/100mL to 5MPN/100mL. The diagnosis of composition of soil after the harvest of chinese cabbages and spinach has shown that the concentration of Na+ was 3-4 times higher in plot using domestic wastewater than in plot using ground water. When domestic wastewater and ground water were used in growing spinach md chinese cabbage at 50% each, the application of chemical fertilizers reduced about 25% to 50% compared to the criteria set down by the Rural Development Administration and there was not significant difference in terms of harvest. Using non-ultraviolet treatment of domestic wastewater directly on spinach and chinese cabbage has resulted in excessive density of total coliform at 25,000MPN/100mL. Even when ultraviolet treatment, the density was still high at 2,000MPN/100mL. The high density of total coliform even following ultraviolet treatment of domestic wastewater is considered to be caused by photo-reactivation of micro-organism. When reusing domestic wastewater, the application of sterilization such as ultraviolet, ultrasonic and electron-beam for public health and hygiene reasons may provide safe supply of agricultural water.