        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The high-temperature properties of mild steels were studied by comparing the test results of Kwon and the yield strength, tangent modulus predicted by the design provisions of ASCE and Eurocode(EC3). The column strengths for steel members at high temperatures were determined by the elastic and inelastic buckling strengths according to elevated temperatures. The material properties at high temperatures should be used in the strength evaluations of high temperature members. The buckling strengths obtained from the AISC, EC3 and approximate formula proposed by Takagi et al. were compared with ones calculated by the material nonlinear analysis using the EC3 material model. The newly simplified formulas for yield stress, tangent modulus, proportional limit and buckling strength which were proposed through a comparative study of the material properties and buckling strengths. The buckling strengths of proposed formulas were approximately equivalent to ones obtained from the formulas of Takagi et al. within 4% . They were corresponded to the lower bound values among the buckling strengths calculated by the design formulas and inelastic buckling analysis.
        4,000원
        3.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 국내에서는 고층 벽식 아파트 건설 시, 하부 주차공간과 공용공간 확보를 위하여 RC 전이슬래브 시스템을 사용하는 경우가 증가하고 있다. 하지만 두께가 얇은 RC 무량판 슬래브를 위해 개발된 설계방법 및 구조성능평가 방법을 두께가 매우 두꺼운 전이슬래브 구조설계에 그대로 사용하고 있다는 문제점이 있다. 따라서 합리적인 전이슬래브의 구조설계를 위해서는 RC 전이슬래브 시스템의 2면 전단거동 양상에 대한 명확한 분석이 필요하다. 이에 따라 본 연구에서는 전이슬래브의 두께, 콘크리트 강도, 전단경간비, 철근비 등 다양한 설계변수에 따라 비선형 FEM을 이용하여 전이슬래브의 2면 전단거동을 분석 하였다. 또한 비선형 FEM 해석결과와 기존의 2면 전단강도 평가식으로 예측한 전단강도를 비교분석하여 기존 평가식의 전이슬래브 2면 전단강도 평가 유효성을 검토하였다.
        4,800원
        4.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As buildings are becoming larger, demand for mega-sized composite columns (over 1-meter diameter) is increased. We have developed and commercialized welded built-up CFT column (ACT Column I) since 2005 which are structurally stable and economical using cold-formed steel with rib. However, there has a limit in size of cross section (618˟618mm) by a fabrication facilities. And due to characteristics of closed cross section, there has a limit to construction of connection of moment frame. Composite mega column (ACT Column II) has same concept of forming closed cross section. But in order to enlarge cross sectional size, thick plate is inserted between cold-formed steels. Since composite mega column can control thickness and width of thick plate, steel or composite beams can be directly attached to the connection. In this study, we propose strength formula of composite mega column to beam connections with T-shaped stiffener as internal diaphragm and verified through finite element analysis and simple tensile experiment.
        4,000원
        5.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents the resizing method of columns and beams that considers column-to-beam strength ratios to simultaneously control the initial stiffness and ductility of steel moment frames. The proposed method minimizes the top-floor displacement of a structure while satisfying the constraint conditions with respect to the total structural weight and column-to-beam strength ratios. The design variable considered in this method is the sectional area of structural members, and the sequential quadratic programming(SQP) technique is used to obtain optimal results from the problem formulation. The unit load method is applied to determine the displacement participation factor of each member for the top floor lateral displacement; based on this, the sectional area of each member undergoes a resizing process to minimize the top-floor lateral displacement. Resizing members by using the displacement participation factor of each member leads to increasing the initial stiffness of the structure. Additionally, the proposed method enables the ductility control of a structure by adjusting the column-to-beam strength ratio. The applicability of the proposed optimal drift design method is validated by applying it to the steel moment frame example. As a result, it is confirmed that the initial stiffness and ductility could be controlled by the proposed method without the repetitive structural analysis and the increment of structural weights.
        4,000원
        6.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recent Engineered nanoparticles were increasingly exposed to environmental system with the wide application and production of nanomaterials, concerns are increasing about their environmental risk to soil and groundwater system. In order to assess the transport behavior of silver nanoparticles (AgNPs), a saturated packed column experiments were examined. Inductively coupled plasma-mass spectrometry and a DLS detector was used for concentration and size measurement of AgNPs. The column experiment results showed that solution chemistry had a considerable temporal deposition of AgNPs on the porous media of solid glass beads. In column experiment, comparable mobility improvement of AgNPs were observed by changing solution chemistry conditions from salts (in both NaCl and CaCl2 solutions) to DI conditions, but in much lower ionic strength (IS) with CaCl2. Additionally, the fitted parameters with two-site kinetic attachment model form the experimental breakthrough curves (BTCs) were associated that the retention rates of the AgNPs aggregates were enhanced with increasing IS under both NaCl and CaCl2 solutions.
        4,000원
        7.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Behavior of RC(Reinforced-concrete) beam-column connections has been subjected to the earthquake loading has been determined by shear and attachment mechanism. However, since the shear and attachment are very fragile for cycle loadings. Through occurring plastic hinges at the beam, the column and the connection should remain elastic condition and the beam should dissipate the energy from the earthquake. This study was investigate on the seismic performance of 6 RC beam - column connections built with the high strength reinforcements (700MPa) based on design and detailing requirements in the ACI 318-05 Provision and KCI-07 appendix Ⅱ. This is aimed to evaluate the effect of the high-strength reinforcements as used the beam-column connection members. The main comparisons were the seismic performance of the connections affect the seismic performance in terms of strength, stiffness and ductility, joint shear stress-strain. A total of 6 beam-column specimens were built with a 1/2 scale and subjected to the cyclic loadings. Main design considerations were the area of the longitudinal reinforcements of the beam and details of the beam-column joint designed based on the seismic code. Cyclic test results are given and recommendations for the usage of high strength reinforcements for the seismic design is provided.
        4,000원
        8.
        2015.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the moment frame subjected to earthquake loads, beam-column joint is structurally important for ductile behavior of a system. ACI Committee 352 proposed guidelines for designing beam-column joint details. The guidelines, however, need to be updated because of the lack of data regarding several factors that may improve the performance of joints. The purpose of this study is to investigate the seismic performance of reinforced concrete exterior joints with high-strength materials and unbonded tendons. Three specimens with different joint shear demand-to-strength ratios were constructed and tested, where headed bars were used to anchor the beam bars into the joint. All specimens showed satisfactory seismic behavior including moment strength of 1.3 times the nominal moment, ductile performance (ductility factor = at least 2.4), and sufficiently large dissipated energy.
        4,000원
        9.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper we present the result of investigations pertaining to the buckling strength of Zelkova Serrata (Elm-like) tree column with entasis at the Muryangsujeon in Buseoksa-Temple, Korea. Wooden columns with entasis had been used in the construction of ancient architectural buildings in Korea. It was not known why did they design columns with entasis of the buildings. It is just presumed that the reason may be the compensation of optical illusion, aesthetics, and/or structural safety. The question is not answered even today and it may not be possible to answer clearly and easily. In the paper, the buckling analyses are conducted on both of the wooden column with entasis and the prismatic wooden column by the successive approximations technique and the finite element methods, respectively. The results of analyses are compared and discussed.
        4,000원
        10.
        2011.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        주각부는 상부의 강구조와 철근콘크리트조 기초의 접합부로써 매우 중요한 부분이다. 현재 국내외 강구조 골조 공사에서 사용되는 주각부의 형식은 크게 구분하여 노출형 주각부 근권형 주각부, 매입형 주각부라고 할 수 있다. 이 중에서 부재의 재사용 및 재활용을 최우선으로 고려한다면 노출형 주각부가 가장 유리하다. 본 연구에서는 이러한 노출형 주각부의 시공 성능 및 역학적 성능을 획기적으로 개선할 수 있는 형태의 강구조 선형상 노출형 주각부를 개발하고, 구조 성능 평가를 위한 탄소성 재하실험을 수행하였다. 그 결과 개발된 신형상 노출형 주각부는 수평 방향과 수직 방향의 시공 오차를 현장에서 간단히 흡수하여 기존 노출형 주각부의 시공 불량을 사전에 방지함으로써 구조 성능을 발휘한다. 또한 에너지 흡수형 고력볼트를 사용함으로써 변형 성능이 증가함을 알 수 있었다.
        4,000원
        11.
        2009.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 논문은 반복-수평력을 받는 프리캐스트 기둥-RC 기초 Anchor 접합부의 반복-수평력에 대한 내력 특성을 규명하기 위함이다. 본 연구는 하부 기초에 프리캐스트 콘크리트 기둥과 기초를 Anchor식으로 접합한 콘크리트 구조체가 정확한 응력전달 경로 및 파괴 메커니즘에 있어서 기존의 콘크리트-강재 연결부와 어떠한 차이가 있는지 제시한다. 반복-수평력 작용하의 철근의 인발력 실험결과는 프리캐스트 기둥-RC 기초 Anchor 시공에 필요한 철근의 최소 필요 삽입 깊이를 제시한다. 또한, 실험을 통해 제시된 응력 전달 경로 및 파괴 메커니즘을 제품별 메뉴얼에 제시되어 있는 메커니즘과 비교, 검토함으로서 접합부의 명확한 응력전달 경로 및 파괴 메커니즘을 시공자의 요구 성능에 맞게 제시한다. 그러므로 본 연구를 통해 프리캐스트 콘크리트 기둥의 정확한 주근의 개수, 공칭직경, 정착 길이 등에 대한 최적의 설계 조건을 제시함으로써, 시공 시 이들에 대한 정확한 데이터를 제공한다.
        4,000원
        12.
        2009.03 구독 인증기관 무료, 개인회원 유료
        A improved strength model was developed to predict the punching shear strength of interior slab-column connections without shear reinforcement. Considering the damage due to flexural cracking at slab-column connections damaged by flexural cracking, the punchingshear force was assumed to be resisted mainly by the compression zone of the critical section. The punching shear strength was defined by using the material failure criteria of concrete. In the evaluation of the punching shear strength, the interaction between the shear stress and the compressive normal stress developed by the flexural moment of the slab was considered. The proposed strength model was verified by existing test specimens.
        4,000원
        13.
        2008.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        TR-CFT(Transversely Reinforced Concrete Filled Steel Tube) 기둥은 CFT 기둥의 국부좌굴부위를 탄소섬유쉬트로 보강을 하여 국부좌굴을 방지하거나 지연시키는 기둥부재이다. 본 연구에서는TR-CFT 기둥의 휨내력 산정을 위한 설계식을 제안하였다. CFT 기둥의 ACI 설계식은 강관내부에 발생하는 콘크리트의 구속효과를 고려하지 않아 저평가 되고 있다. 따라서 본 연구에서는 구속효과를 고려한 콘크리트의 응력-변형률 곡선를 이용하여 CFT 기둥과 TR-CFT 기둥의 휨내력 산정식을 제안했으며 해석에 의한 예측 값들은 실험값과 잘 일치함을 확인할 수 있었다.
        4,000원
        14.
        2006.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 지진하중을 받는 내부 및 외부 철근콘크리트 보-기둥 접합부의 강도 및 연성능력을 평가하였다. 접합부에 인접한 보에 소성힌지가 발생한 이후 접합부가 파괴할 경우 접합부 내력은 보의 소성힌지의 영향을 받아 감소하게 된다. 보에 소성힌지가 발생하면 보의 부재축방향 변형률은 급격하게 증가하게 되며, 증가된 부재축방향 변형률은 접합부의 변형에 영향을 주어 접합부의 강도를 저감시킨다. 이 논문에서는 보에 소성힌지가 발생하기 이전에 파괴하는 접합부의 내력과 보에 소성힌지가 발생한 이후에 파괴하는 접합부의 연성능력을 접합부의 변형능력 및 스트럿의 강도저감을 이용하여 평가하였다. 제시한 평가법은 52개의 접합부 실험체를 이용하여 검증하였다.
        4,000원
        15.
        2005.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        부재의 내력비, 강성비에 영향을 받는 다층 강구조 골조의 내진성능을 평가하기 위하여 내력비 및 강성비를 설계 파라메타로 하여 동적 비탄성 응답해석을 수행하였다. 해석 결과에 대한 분석을 통하여 내력비와 강성비의 변화폭이 큰 다층골조의 손상분포 예측식을 제안하였다. 본 연구에서 얻어진 결과는 다음과 같이 요약할 수 있다. 1) 보기둥 내력비 및 강성비가 작아질수록 1층의 기둥 주각부에서의 손상집중 현상이 크게 나타났다. 2) 보기둥 내력비 및 강성비를 고려하여 보붕괴형 강구조 다층골조의 손상분포를 예측할 수 있는 식을 제안하였으며, 예측식은 응답해석 결과와 좋은 대응을 보였다. 3) 본 연구에서 제안한 손상분포 예측식은 강접 및 반강접 보붕괴형 강구조 다층골조의 손상분포를 예측할 수 있을 것으로 판단된다.
        4,000원
        16.
        2003.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        탄소섬유튜브는 기존의 콘크리트 기둥에 강도와 연성을 제공하여 길이방향 및 횡방향 철근을 대신할 수 있다. 본 연구에서는 탄소섬유튜브에 의해 구속된 각형 콘크리트의 축하중에 대한 실험 및 해석적 연구를 수행하였다. 탄소섬유튜브는 길이방향에 대하여 90^{\circ}\pm30^{\circ}, 90^{\circ}\pm45^{\circ}로 섬유의 방향을 조합하여 필라멘트 와인딩 방법으로 제작하였다. 10,000kN UTM을 이용하여 단조축하중을 재하하였다. 섬유의 방향, 튜브의 두께에 따른 횡구속된 콘크리트 기둥의 응력-변형률 관계를 고찰하였다. 탄소섬유튜브에 의해 횡구속된 콘크리트의 압축강도와 연성을 예측하기 위하여 제안된 실험식은 실험결과를 적절히 예측하는 것으로 나타났다.
        4,000원
        17.
        2000.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        전편의 실험적 연구에 이어서, 기 수행된 4개의 외부 접합부 시험체에 현존하는 여러 강도 예측식을 사용하여 콘크리트 기둥-강재 보 접합부의 내진 성능을 결정하는 패널 전단 및 지압 강도를 평가하였다. 또한, 접합부 패널지역의 변형특성을 묘사할 수 있는 일련의 스프링을 사용한 macro 형태의 해석모델이 논의되었으며, 이에 따라 Drain-2DX 및 IDARC 등의 상용프로그램을 사용하여 접합부의 패널전단 및 지압 파괴형태의 변형을 포함하는 단순해석이 수행되었다. 강도 예측결과에 의하면 본 연구에서 제시하는 수정된 내부 콘크리트 패널 전단 강도식을 포함하고 있는 ASCE 방법이 실험결과에 가장 근접한 것으로 나타났으며, 본 연구에서 검토된 패널지역 변형을 고려한 단순해석모델은 향후 전체 건물해석에 사용할수 있는 것으로 판단되었다.
        4,000원
        18.
        1999.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        고강도 콘크리트는 부재의 내력증가 뿐만아니라 내구성을 증대시키기 때문에 널리 사용되고 있다 그러나 고강도 철근콘크리트 보-기둥 접합부의 구조성능에 관한 연구자료는 충분하지 않은 실정이며 현행규준 또는 일반강도 콘크리트의 실험에 근거하고 있다 따라서 본 연구에서는 일반강도 (f_c'=240kg/\textrm{cm}^2) 및 고강도(f_c'=700kg/\textrm{cm}^2) 콘크리트를 사용하여 실제의 중진지역 30층 실제구조물의 2/3크기를 축소한 보와 기둥 슬래브로 구성된 네 개의 부분구조체를 제작하여 유사정적실험을 통한 구조거동과 파괴형태를 조사하고 전단내력에 대한 현행규준과 비교 검토하였다.
        4,300원
        19.
        2018.09 KCI 등재 서비스 종료(열람 제한)
        모듈형 구조시스템은 학교 및 아파트 건물과 같은 저층 및 중층 구조물에 점점 더 많이 사용되고 있다. 최근에는 고층 건물에 모듈러 구조시스템을 적용하는 방법에 대한 연구가 수행되고 있다. 고층 모듈러 구조시스템에 대해 충분한 저항력과 경제적인 구조를 제공하기 위해 복합모듈 구조시스템이 제안되었다. 본 연구에서는 일련의 실험을 통해 단위 복합모듈 구조에 적용하기 위한 목적으로 비대칭 복합 기둥의 강도를 평가하고자 하였다. 실험적 연구는 기둥의 세장비, 편심율 및 관통바 유무에 따라 기둥의 강도에 미치는 영향에 중점을 두었다. 단위 모듈 구조에 대한 비대칭 기둥단면의 설계식을 제안하였다. 결과로부터, 설계식은 단위 복합모듈 구조에서 비대칭 기둥단면의 적절한 강도 예측을 제공한다는 것을 알 수 있다.
        20.
        2018.04 서비스 종료(열람 제한)
        In this study, compressive tests were carried out on seamless circular tubular short columns with corrosion-damaged end, and investigated change in compressive strength of columns with local corrosion at the end. Local corrosion was artificially introduced by milling machine, and differed in corrosion depth (0, 1.5, 3, 4.5 mm), corrosion height (0, 20, 60, 120 mm), and corrosion circumference (0, 90, 180, 360˚ ). As a result, the compressive loads were linearly decreased with increasing of corrosion degrees, and a quantitative evaluation for residual compressive strength of seamless circular tubular short column with corrosion-damaged end was suggested by using corroded volume loss ratio.