제한된 토지의 효율적 이용을 위하여 건물들이 점점 더 거대화, 초고층화 되어가고 있기 때문에, 대형합성기둥에 대한 수요가 증가하고 있는 추세이다. 선행 연구를 통하여 리브를 갖는 냉간성형강재를 사용하여 구조적으로 안정적이며 경제적 인 충전강관기둥(ACT Column Ⅰ)이 기존에 개발되었으나, ACT Column Ⅰ은 크기가 제한(618×618)되는 문제가 있기 때문에 새로운 폭 1m이상 고하중용 대형합성기둥의 개발이 필요하다. 본 연구에서는 폭이 커지고 접합부 형식이 단순해지는 대형합성기둥(ACT Column Ⅱ)를 제안하고, 바인딩프레임이 보강된 실험체를 중심압축가력하여 구조성능을 확인하였다. 콘크리트 충전 여부 및 바인딩프레임의 보강 폭과 면적을 변수로 한 바인딩프레임 보강 실험체를 중심압축가력 하여 실험체 최대내력 값과 KBC2016 합성구조 설계메뉴얼에 따른 설계내력을 비교한 결과 ACT Column Ⅱ이 대형합성기둥으로써 안정적으로 거동함을 확인하였다.
Recently, the damage caused by typhoons and strong winds are increasing due to the world climate change. Considering the vulnerability of structure to strong wind disaster, in this study, we focused on the soundproof wall among vulnerable wind facilities. GFRP was chose as the reinforcement frame among the components of the soundproof wall. The modeling of the soundproof wall was made using the finite element commercial analysis program ABAQUS and the resistance performance was estimated through the optimal model analysis of the soundproof wall. Wind loads were calculated using Monte Carlo Simulation. Finally, wind fragility evaluation was performed to predict the degree of damage of the GFRP frame soundproof wall. It is necessary to verify the performance of the GFRP frame through comparison with the aluminum frame which is generally used in the construction of the soundproofing wall.
As the ridges become larger and larger, a structural type that enables effective utilization of the long span and space is required. In the construction stage, the steel column supports the installation load. However, in order to secure the stability against the out - of - plane deformation of the steel column due to the lateral pressure when the concrete is laid, a binding frame is installed inside the steel pipe at constant intervals to resist the concrete installation pressure. When the concrete is cured and its performance as a composite section is exerted, a stress is generated which pushes the steel pipe out of the plane by the column compressive force. In this case, since the binding frame controls the deformation, the local buckling is delayed and the constraining effect on the concrete is increased. In order to evaluate the structural performance and behavior of the composite mega column according to the eccentricity effect and the effect of the binding frame, we carried out a structural test by fabricating eight monopole specimens with the binding frame reinforcement, reinforcing gap, reinforced cross section and eccentricity , And the experimental results are compared with the KBC2016 design formula.
Composite columns are increasingly used due to the construction of super-tall buildings and large-scale buildings. Studies on the shapes of and construction technologies for structural members using steel tubes are being conducted actively. Welded built-up CFT columns previously developed and commercialized by the authors of this study (ACT-1 columns) are structurally stable and economically efficient. However, the 1m limit in the width of the columns and their small interior spaces impose a difficulty in installing reinforcing materials and thus deteriorate the ease and efficiency with which they are constructed. This study suggests placing thick plates at the centers of the surfaces of the existing ACT-1 column and installing a binding frame (binding frames) at the central thick plates to enhance the integrity and resist lateral pressure caused by concrete casting. Finite element analysis was conducted with the variables of the number and cross-sectional size of the binding frame and the cross-sectional size of the steel tube to estimate the structural behavior of the steel tubes. Hydraulic tests were conducted to analyze load-displacement relations and identify the influence of the binding frames on the relations. The variables in the tests were the number and cross-sectional size of the binding frame, welding details, column joint and the cross-sectional size of the steel tube
Since it is impossible to predict earthquakes, they involve more casualties and property damage compared to meteorological disasters such as heavy snow and heat waves, which can be predicted through weather forecasts. This has highlighted the need for seismic design and reinforcement. Recently, the use of composite materials as reinforcement has surged because steel plate reinforcement and section enlargement are likely to result in increased weight and physical damage to structures. This study evaluates the seismic performance of panels created from composite materials, and their guide systems. The specimens were miniature versions of actual steel structures, and displacement loads were applied in the transverse direction. Seismic performance was found to improve when structures were reinforced with seismic panels.
We evaluated structural performance of Frame for uniformly distributed load to micro piles which was arranged in a line. We predicted behavior and load distribution with Abaqus which is general finite analysis program. And Structrual experiment was conducted using full scale test model.
As development of the construction technique, new composite material has been developed and research on structures made of this material is needed recently. In this study, curved composite laminated frame structure with four ply is analyzed using shell elements. There are six angle change cases and maximum vertical displacement with case 2 and 6 which have ±45 degree is smaller than other cases’ displacements.
The water tanks are widely used for the safe storage of potable water, which are installed on either the basement or the top floor inside of the buildings. Therefore, the water tank systems assembled with many unit panels are generally adopted and the rectangular plan water tanks are most popular. To resist the water pressure acting on the side walls of tanks the internally reinforced system using metal tie-bars has been most commonly used. However, many problems related to the lattice internal reinforcement system require the development of the externally reinforced water tank, which does not have any latticed tie bars inside the tank. In this study two different systems have been developed using the external steel frames with either the SMC water tank panels or the PosMAC(coated steel) water tank panels. The experimental tests have been performed under the static hydraulic loadings as well as the seismic loadings through the shaking table test.