검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 18

        1.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        An Ant Colony Optimization Algorithm(ACO) is one of the frequently used algorithms to solve the Traveling Salesman Problem(TSP). Since the ACO searches for the optimal value by updating the pheromone, it is difficult to consider the distance between the nodes and other variables other than the amount of the pheromone. In this study, fuzzy logic is added to ACO, which can help in making decision with multiple variables. The improved algorithm improves computation complexity and increases computation time when other variables besides distance and pheromone are added. Therefore, using the algorithm improved by the fuzzy logic, it is possible to solve TSP with many variables accurately and quickly. Existing ACO have been applied only to pheromone as a criterion for decision making, and other variables are excluded. However, when applying the fuzzy logic, it is possible to apply the algorithm to various situations because it is easy to judge which way is safe and fast by not only searching for the road but also adding other variables such as accident risk and road congestion. Adding a variable to an existing algorithm, it takes a long time to calculate each corresponding variable. However, when the improved algorithm is used, the result of calculating the fuzzy logic reduces the computation time to obtain the optimum value.
        4,000원
        4.
        2015.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        태양광 패널로부터 출력을 최대로 얻기 위해서는 신뢰성이 높은 태양광 추적 장치가 설계되어야 한다. 본 논문에서는 LabVIEW 프로그램을 이용하여 퍼지 제어를 기반으로 구현한 2축 태양광 추적 장치 시스템을 제작하여 그 성능에 대해서 알아보았다. 태양광 패널의 움직임을 제어하기 위한 구현된 퍼지 의사결정 시스템의 사용자 인터페이스를 통하여 모든 파라미터를 제어하고 확인할 수 있는 지능제어기와 기계적인 구동부분의 설계가 연구의 중심이 되고 있다. 실제 태양광 추적시스템을 개발하여 환경, 날씨, 계절 및 빛 상태와 같은 영향에 대해서 분석하였다. 태양광 추적장치는 실제 상황에서 시험하였고 시스템 동작과 관련된 모든 변수들은 기록되고 분석되었다. 제안한 태양광 추적시스템을 활용할 경우 고정식 패널에 비해 날씨에 따라 다르지만 최대 약 38% 정도의 더 높은 효율을 얻을 수 있어 자동으로 추적할 때 매우 좋은 결과를 얻을 수 있었다.
        4,000원
        7.
        2010.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        오늘날 인터넷의 출현과 확산으로 인하여 정보의 홍수를 이루게 되었고, 고객들은 자신이 원하는 제품이나 서비스를 선택하기 위해서 정보를 탐색하는 작업이 더욱 어려워지게 되었다. 이러한 고객들에게 좀 더 편리하게 자신이 원하는 제품이나 서비스를 선택하도록 도와주는 것이 추천 시스템으로써, 고객 관계 관리의 중요한 부분으로 자리잡게 되었다. 본 연구에서는, 인터넷상의 여행사 사이트 등에서 고객이 여행지를 선택할 때 고객이 관심을 가질만한 여행지를 추천하여 줌
        4,000원
        8.
        2006.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 우리나라 RCC/RSC의 효율성을 2개의 투입자료와 4개의 산출자료를 이용하여 DEA법을 이용하여 측정하였고, 정성적 자료는 전문가의 설문 및 면접결과로 평가하였다. 또한, 이러한 자료를 통합하기 위한 방법은 의사결정지원시스템인 퍼지로직을 적용하였고, 이 평가방법을 이용하여 RCC/RSC의 운영효율성의 우선순위를 평가하였다. 그 결과 목포, 제주, 부산, 통영, 인천, 여수, 동해, 울산, 포항, 속초, 태안, 완도, 군산RSC 순으로 효율성이 높은 것으로 나타났다.
        4,000원
        10.
        2006.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        해상에서 해양사고를 예방하고 선박의 통항안전성을 증대시키기 위해 연안 VTS와 항행보조시설이 적극 검토되고 있다. 그러나 이러한 시설의 설치에는 막대한 비용과 예산이 든다. 따라서 연안해역에 통항 위험성을 평가하여 우선순위를 결정해야하고 통항 위험성평가는 조선자의 관점에서 평가되어야 한다. 한편, 인간의 사고에는 많은 형태의 애매함이 존재하기 때문에 이러한 애매함을 반영하기 위해 본 연구에서는 퍼지로직과 쇼케적분을 이용하여 연안해역의 선박 통항안전성을 평가하였다. 본 연구의 목적은 퍼지로직과 쇼케적분을 이용하여 조선부담감을 고려할 수 있는 평가모델을 개발하고 우리나라 연안해역을 8개로 나누고 연안 VTS와 항행보조시설 설치의 우선순위를 결정하기 위한 평가를 실시하였다.
        4,000원
        11.
        2000.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        중층트롤어구의 수심 제어는 시스템의 복잡성과 비선형성 등으로 인하여 아직까지 자동화되지 않았다. 본 연구에서는 회류수조에서 작동되는 모형 트롤어구의 예망시스템을 제작하였으며, 이 시스템의 수심을 자동으로 제어하기 위해서 퍼지논리를 이용한 제어시스템을 구성하여 성능을 실험하였다. 제어시스템의 수심제어 규칙은 숙련된 항해사나 선장이 실제 조업에서 어구의 수심을 제어하기 위해 사용하는 지식을 제어규칙화 한 것과 모형실험에 적합하도록 수정한 규칙 두 가지를 사용하였다. 제어계의 성능은 예망속도를 일정히 유지하면서 목표수심을 스텝상으로 변경시켰을 때의 추종성능 실험과 목표수심을 일정히 유지하면서 예망속도를 변경시켰을 때의 보상성능을 실험을 통하여 분석하였다. 1. 본 연구에서 제안된 두 가지 제어기는 모두 일정한 유속(0.35m/s)에서 스텝상의 목표수심 변경에대해서 빠른 추종성능을 나타내었다. 특히 수정된 제어규칙에서는 모형 어구의 수십을 보다 안정되게 제어하였다. 2. 예망속도(유속)를 변화시켜 어구저항을 증감시킨 실험에서도 두 제어기는 비교적 양호한 보상 성능을 나타내었는데, 실제 조업에서 사용하는 규칙은 작은 외란에도 빨리 반응하였으며, 수정된 제어규칙은 수심편차가 어느 정도 커져야 제어동작을 하였다. 3. 본 연구에서 제작된 모형트롤시스템은 실물트롤 시스템의 운동 특성과 거의 일치하였고, 또한 설계된 제어기는 양호한 제어성능을 나타내어 모형실험을 통한 시스템의 해석과 실물 트롤시스템에 적용가능성이 높은 제어계의 설계가 가능하였다
        4,000원
        12.
        1994.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper describes the model of a simplified trawl system and a control method by using fuzzy algorithm in controlling the depth of trawl gear. Fuzzy logic control rules are sets of linguistic expression that are used by an experienced performer in real operation. For real time processing of the control rules, the look-up tables are used. Computer simulation results indicate that the proposed fuzzy controller shows fast response with minimum steady-state error and robustness properties to the simulated disturbance.
        4,000원
        13.
        2020.08 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        Nowadays, many construction engineering and technology enterprises are evolving to find that prosperity is driven and inspired by an open economy with dynamic markets and fierce multifaceted competition. Besides brand and product uniqueness, the ability to quickly provide customers with quotes are matters of concern. Such a requirement for prompt cost estimation of construction investment projects with the use of a construction price index poses a significant challenge to contractors. This is because the nature of the construction industry is shaped by changes in domestic and foreign economic factors, socio-financial issues, and is under the influence of various micro and macro factors. This paper presents a fuzzy decision-making approach for calculating critical factors that affect the construction price index. A qualitative approach was implemented based on in-depth interviews of experts in the construction industry in Vietnam. A synthetic comparison matrix was calculated using Buckley approach. The CoA approach was applied to defuzzified the fuzzy weights of factors that affect the construction price index. The research results show that the top five critical factors affecting the construction price index in Vietnam are (1) consumer price index, (2) gross domestic product, (3) basic interest rate, (4) foreign exchange rate, and (5) total export and import.
        14.
        2018.04 서비스 종료(열람 제한)
        The study discusses the strength development of fresh concrete using fuzzy logic on Electromechanical impedance(EMI) data collected through Piezoelectric(PZT) sensors. For gaining data to estimate real time strength development of concrete through sensors, 3 specimens of concrete were casted for experiment. The PZT sensors were embedded in experimented concrete to perform dual job of actuating and sensing. In this technique with poring of concrete the PZT material starts actuating to produce vibrations, for the same time these materials work as sensors and measure the dynamic responses of the vibrations. Thus, with development of concrete strength the resonant frequencies of EMI start changing. The process of measuring data was continued for every hour for 28 days, after getting EMI data, it was treated by fuzzy logic technique to get a clear strength curve for defining strength development pattern. The change observed in EMI data curve leads to estimating concrete strength.
        15.
        2012.02 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 괴산댐 하류 달천에서 성어기 피라미에 대한 물리 서식처 모의를 수행하였다. 이를 위하여 퍼지논리에 의한 서식처 적합도 지수를 산정하는 CASiMiR 모형을 이용하였다. 또한 모의결과를 서식처 선호도 곡선을 이용하여 서식처 적합도 지수를 산정할 수 있는 수리모형인 River2D 모형의 결과와 비교, 분석하였다. CASiMiR 모형의 수위 자료는 River2D 모형을 통한 수위계산결과를 활용하였으며 현장측정자료와 비교한 결과 잘 반영하는 것을 확인하였다. 대상구간의 만곡부 상류 직선구간에 있는 여울에서 성어기 피라미의 서식처가 가장 적합한 것으로 나타났다. CASiMiR 모형의 경우 7.23m3/s의 유량조건에서 가중가용면적이 최대값을 보였고, River2D 모형은 9m3/s의 유량에서 최대 가중가용면적을 예측하였다. 또한 갈수량(Q355), 저수량(Q275), 평수량(Q185), 풍수량(Q95) 유량조건에서 CASiMiR 모형은 River2D 모형에 비해 가중가용면적을 0.3~25.3% 정도 과대 추정하는 결과를 보였다.
        16.
        1994.11 KCI 등재 서비스 종료(열람 제한)
        A practical application of a fuzzy control system is described for an air-conditioning system. Air-hadling units are being widely used for improving the performance of central air-conditioning systems. The fuzzy control system has two controlled variables, temperature and humidity, and three control elements, cooling, heating, and humidification. In order to achieve high efficiency and economical control, especially in large offices and industrial buildings, two controllable parameters, temperature and humidity, must be adequately controlled by the three final controlling elements. In this paper a fuzzy control system was described for controlling air-conditioning systems efficiently and economically.
        17.
        1984.06 KCI 등재 서비스 종료(열람 제한)
        Many studies have been done in the field of fuzzy logic theory, but it's application to the ship's steering system is few until this date. This paper is to survey the effect of application of fuzzy logic control by new compositional rule of Inference to the ship's steering system. The controller is made up of a set of Linguistic Control Rules which are conditional linguistic statements connecting the inputs and output, and take the inputs derived from deviation angle and it's angular velocity. The Linguistic Control Rules are implemented on the digital computer to verify the performance of the fuzzy logic controller and simulations have been done in six cases of initial condition and disturbance type. Consequently, it was proved that the ship's steering system by introducing the F.L.C. is performed efficiently and less energy loss system compared with the conventional autopilot.
        18.
        1981.12 KCI 등재 서비스 종료(열람 제한)
        Many studies have been done in the field of fuzzy logic theory, but it's application is not so much, and particularly, there isn't any application to the ship's steering system, until now. This paper is to survey the effect of application of fuzzy logic control to the ship's steering system. The controller is made up of a set of Linguistic Control Rules which are conditional linguistic statements connecting the inputs and the output, and take the inputs derived from the errors, that is, deviation angle and it's angular velocity. These two variables together give information about the state of the steering system, and the Linguistic Control Rules are implemented on the digital computer. The characteristics of this system were investigated through the computer simulation and satisfactory results compared with that of the conventional PD controller were obtained.