검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 9

        1.
        2022.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Research is being actively conducted on the continuous thin plate casting method, which is used to manufacture magnesium alloy plate for plastic processing. This study applied a heat transfer solidification analysis method to the melt drag process. The heat transfer coefficient between the molten magnesium alloy metal and the roll in the thin plate manufacturing process using the melt drag method has not been clearly established until now, and the results were used to determine the temperature change. The estimated heat transfer coefficient for a roll speed of 30 m/min was 1.33 × 105 W/m2·K, which was very large compared to the heat transfer coefficient used in the solidification analysis of general aluminum castings. The heat transfer coefficient between the molten metal and the roll estimated in the range of the roll speed of 5 to 90 m/min was 1.42 × 105 to 8.95 × 104 W/m2·K. The cooling rate was calculated using a method based on the results of deriving the temperature change of the molten metal and the roll, using the estimated heat transfer coefficient. The DAS was estimated from the relationship between the cooling rate and DAS, and compared with the experimental value. When the magnesium alloy is manufactured by the melt drag method, the cooling rate of the thin plate is in the range of about 1.4 × 103 to 1.0 × 104 K/s.
        4,000원
        2.
        2021.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the effect of thermal grease and heat sink material of cooler on CPU temperature was measured and compared with LinX(v0.9.6) and HWMonitor.When the computer is booted without thermal grease applied, the CPU temperature rises rapidly, and the CPU temperature reaches 100℃ after 60 seconds for aluminum heat sink and 140 seconds for copper heat sink. The CPU temperature is lower as the thermal conductivity coefficient of thermal grease is higher, and the CPU temperature is lower when the thermal conductivity coefficient of the cooler is higher. In addition, when using a thermal grease and a heat sink with a high coefficient of thermal conductivity, the cooler rpm can be lowered, which is considered to be advantageous in terms of system stability and energy saving.
        4,000원
        3.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to enhance heat insulation effect and to decrease fire hazard by attaching aluminum foil to expanded polystyrene, which is mainly used for insulating materials, to have fire retardant. The result of the test confirmed that the insulating materials, expanded polystyrene of 10 kg/m3 and 14 kg/m3 of density attached aluminum foil on both sides, showed 12%, 14% of improved heat transfer coefficient respectively compared to existing expanded polystyrene of the same density. Besides, they met all the standards for the testing of heat release and gas hazard. On the other hand, the one made of general expanded polystyrene could not meet the standards of the heat release test and the gas hazard test.
        4,000원
        4.
        2018.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        겨울철에 열손실을 줄이기 위해 많은 온실에서 보온커튼을 사용하고 있다. 그러나 적절한 보온커튼을 선택할 때 판단 자료로 활용할 수 있는 명확한 기준이 없는 실정이며 이를 위해서는 보온재의 보온 특성에 대한 정량적인 값이 필요하다. 본 연구에서는 BES를 사용하여 보온커튼의 관류열전달계수를 산정하는 시뮬레이션 모델을 개발하였다. 일중 및 이중 PE필름 피복에 대한 관류열전달계수의 실험값을 사용하여 시뮬레이션 결과를 검증하였다. 검증된 모델을 사용하여 문헌에서 제시된 각종 열적 특성을 가진 보온커튼에 대한 관류열전달계수를 산정하고 비교분석하였다. 개발된 시뮬레이션 모델은 다양한 보온커튼의 관류열전달계수를 산정하는데 활용될 수 있을 것이며, 제시된 관류열전달계수는 보온커튼의 성능을 정량적으로 비교하는데 유용하게 활용 될 수 있을 것으로 판단된다.
        4,000원
        5.
        2015.12 구독 인증기관 무료, 개인회원 유료
        This study calculated the overall heat transfer coefficient (U-value) of greenhouse covering materials with thermal screens using a simulation model and then estimated the validity of the calculated results by comparison with measured values. The U-value decreased gradually as the thickness of the air space between the double glazing increased, and then remained essentially constant at thicknesses exceeding 25 mm. The U-value also increased with the difference in temperature between the inside and outside of the hot box. The vigorous convective heat transfer between two plastic films caused unsteady heat flow and then created a nonlinear temperature distribution in the air space. The distance did not affect the U-value at distances of 50~200 mm between the plastic covering and thermal curtain. The numerical calculation results, with and without sky radiation, were in accord with the experimental results for a 30°C temperature difference between the inside and outside of the hot box. In conclusion, a reliable Uvalue can be calculated for a temperature difference of 30°C or more between the inside and outside of the hot box.
        4,000원
        6.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The present experimental study investigates single-phase heat transfer coefficients downstream of support grid in 6×6 rod bundles. Support grid with Split mixing vanes enhance heat transfer in rod bundles by generating turbulence but this turbulence is confined to a short distance. Support grid with large scale vortex flow(LSVF) mixing vanes enhanced heat transfer to a longer distance. In this study, the experiments were performed at reynolds numbers of 50,000. The characteristics of the heat transfer enhancement of the Split mixing vane and those of the LSVF mixing vane were compared. The results showed that the characteristics of the heat transfer enhancement of rods by the Split mixing vane were limited to 10 Dh after the spacer grid, but those by the LSVF mixing vane were maintained until 15 Dh after the spacer grid. For the reynolds number of 50,000, the heat transfer enhancement effect was 3.0% greater when using the LSVF mixing vane than when using the Split mixing vane between the 1 ∼ 15 Dh interval after the spacer grid.
        4,000원
        7.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 일중피복온실의 피복재에 대하여 우리나라 환경에 적합한 관류열전달계수를 산정하는 방법을 찾아내고 검증하여 다양한 온실조건 및 환경조건에서 관류열전달계수를 산정할 수 있는 모델을 제시하는 것이다. 온실내부 및 외부온도와 피복재 표면온도와의 상관관계를 분석한 결과 주간 및 야간 온도를 모두 고려하였을 때보다 야간온도만을 고려하였을 경우가 상관성이 훨씬 더 높은 것으로 나타났다. 피복재의 표면온도가 온실의 외부온도보다는 내부온도와 상관성이 더 높은 것으로 나타났다. 관류열전달계수를 산정하는데 사용된 5가지 종류의 대류 및 복사열전달계수 산정식을 비교한 결과 Kittas가 제안한 대류 및 복사열전달계수 산정식이 가장 적합한 것으로 나타났다. 피복재 표면온도의 측정값과 계산 값의 상관성을 분석한 결과 직선의 기울기는 1.009이고 절편은 0.001이며 결정계수가 0.98로 나타나 본 연구에서 제시된 관류열전달계수 산정모델이 신뢰성이 있음을 확인할 수 있었다. 온실내부로부터 피복재 내부표면으로 전달되는 열흐름량의 경우 모든 풍속구간에 대해 대류열전달량이 복사열전달량보다 더 컸으며 풍속이 증가할수록 그 차이가 증가하였다. 외부표면에서 손실되는 열흐름량의 경우 풍속이 낮을 때에는 대류열전달량에 비해 복사열전달량이 더 컸으나 풍속이 증가함에 따라 그 차이는 점점 줄어들어 풍속이 높을 때에는 대류열전달량이 더 커지는 것으로 나타났다. 피복재 외부 표면의 대류열전달량은 내부표면의 대류열전달량에 직선적으로 비례하여 증가하는 것으로 나타났다. 풍속이 증가함에 따라 관류열전달계수는 증가하고 피복재의 표면 온도는 감소하는 것을 확인할 수 있었고, 변화추세를 보면 관류열전달계수는 거듭제곱함수와 그리고 표면온도는 로그함수와 잘 일치하였다.
        4,000원
        8.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 국내 상업용 온실 피복재의 관류열전달계수를 산정히는데 필요한 기초자료를 제공하기 위하여 최근 국내에 많이 보급되어 사용되고 있는 플라스틱필름으로 피복된 온실에 대해 관류열량을 측정하고 관류열전달계수의 변화를 분석하였으며 그 결과를 요약하면 다음과 같다. 온실 내외부 온도차에 따른 관류열전달계수의 변화를 분석한 결과 피복의 층수에 따라 안정된 관류열전달계수를 나타내게 되는 온실 내외부 온도차의 값이 다르게 나타났기 때문에 온실 피복재에 대한 관류열전달계수를 결정할 때에는 피복층수별로 안정된 값을 나타내는 온실 내외부 온도차 범위에서의 관류열전달계수를 채택하여야할 것이다. 온도차이에 따른 관류열전달계수의 변화 경향은 기존의 연구결과와 잘 일치하였으나 안정된 값을 나타내는 온도차이의 구체적인 값은 다르게 나타났기 때문에 이에 대한 추가적인 연구가 필요할 것으로 판단된다. 풍속에 따른 관류열전달계수의 증가율은 연구자에 따라 많은 차이가 있음을 알 수 있었으며, 이중피복온실이나 커튼을 설치한 온실과 같이 보온성을 높인 온실은 일중피복온실에 비해 풍속에 따른 관류열 손실이 더 작다는 사실을 확인할 수 있었다. 관류열전달계수의 기존 연구결과들을 분석한 결과 연구자에 따라 값이 차이가 있었기 때문에 국내 온실의 정확한 난방부하량을 산정하는데 필요한 적절한 관류열전달계수를 제시하기 위해서는 우선 측정을 위한 표준화된 환경기준이 마련될 필요가 있으며, 또한 국내에서 실제로 사용되고 있는 주요 피복재별로 구체적인 관류열전달계수가 구해져야 할 것이다.
        4,000원
        9.
        2010.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        고준위 방사성 폐기물 처분장의 경우 폐기물의 방사성 붕괴에 의해 열이 발생되며, 암반을 통한 열전달 에 의해 처분장 주변 환경이 변화됨으로써 처분장의 안전성에 영향을 미칠 수 있다. 그러므로 지하 처분장 대기의 열전달계수를 결정하는 것은 매우 중요하다. 이에 본 연구에서는 Korea Atomic Energy Research Institute Underground Research Tunnel (KURT)에서 내부 환경 인자들의 측정을 통해 강제대류시 열전달계수를 산정하였다. 실험을 위해 KURT 내 히터구간의 막장 벽면에는 길이 2 m, 용량 5 kw의 히터를 삽 입하여 암반 내부를 90℃로 가열하였고, 외부와 연결된 급기용 팬에 의해 신선한 공기를 공급하였다. 연구 결과, 외부공기 공급 후 히터구간 대기의 기류속도는 평균 0.81 m/s로 측정되었고 레이놀즈수는 약 310,000 340,000의 값을 나타냈다. 그리고 강제대류조건에서 히터구간 내 계절별 열전달계수는 각각 여 름철 7.68 W/m2·K와 겨울철 7.24 W/m2·K의 수치를 나타냈다.
        4,200원