In this study, Rebar of SD500, SD600 is applied to the designed or constructed in domestic apartment. Analyzed the variation of the rebar according to the strength of the rebar and the construction cost of the change. Reinforced volume reduction of the apartment building is less than the other. Because, A low wall of rebar reduction is more than 50% of the total. The reason for the previous, Reduction of the quantity of horizontal reinforcement does not appear and Vertical rebar reinforcement than the stress is determined by the placement of rebar in which the upper floor.
In this technology, To improves the performance of deflection of the slab reduces floor impact noise in downstairs without structural work in vulnerable to floor impact noise in Aged Apartment Houses. The finite element analysis results showed the performance improvement of slab when compared with the existing technologies and Predict the result of the excellent affordability and constructability.
In this study, Rebar of SD500, SD600 is applied to the designed or constructed in domestic underground parking. Analyzed the variation of the rebar according to the strength of the rebar and the construction cost of the change. Most of underground parking appear reduction of Rebar ratio. In this case, the load acting on the underground parking garage is large. So, Rebar placing is dominated by element's stress. Therefore, Large amounts material of slabs, beams and foundations are reduced. In case of columns and wall, Ratio of Material reduction is less than former. Because Splice and Anchorage of rebar amounts are increased and Hoop and horizontal rebar amounts are fixed. Percentage of rebar of the column and wall are 15%. So, Showed a less impact on the reduction of total material.
Strength bar has merits in workability improvement, construction time shortening and connection details to be easy. But, lap splice length tends to be longer. In this study, high strength threaded bar will be reviewed whether it is appropriate in domestic standards by KCI concrete structural criteria and propose the mechanical splice.
본 논문은 강섬유 보강 콘크리트 부재에 수직으로 기계적 정착된 고강도 확대머리철근의 정착성능을 평가하기 위하여 실시한 기초 인발실험결과를 정리한 것이다. 주요 실험변수는 강섬유의 혼입률, 콘크리트 강도, 정착길이, 확대머리철근 항복강도 , 전단보강유무 등이다. 실험체의 좌우 순피복두께는 확대머리철근 직경의 두 배로 계획하였다. 확대머리철근을 중심으로 1.5ldt,0.7ldt가 되는 위치에 힌지 지점을 두고, 확대머리 철근을 직접 인발하였다. 인발실험결과, 실험변수에 따라 콘크리트 파괴 및 철근 인장파단이 나타났다. 강섬유를 보강한 실험체가 동일한 변수의 강섬유를 보강하지 않은 실험체에 비히여 콘크리트 압축강도는 2.7~5.4% 크게 나타난 반면 인발강도는 20.9~63.1% 크게 나타나 정착성능 향상에 큰 기여를 하는 것으로 평가되었다. 강섬유 보강 콘크리트에 대해 확대머리철근과 평행한 전단보강근의 배근은 1.7~7.7% 인발강도를 증가시켰으나, 콘크리트 강도 증가를 고려할 때 정착성능 향상에 미치는 영향이 크지 않았다. 본 실험체 상세와 같이 강섬유보강 콘크리트 부재에 수직정착된 SD600의 확대머리철근 정착설계는 KCI2017, KCI2012의 정착길이 설계식을 그대로 사용할 수 있을 것 으로 사료된다.
The purpose of this study is to investigate the effects of reinforcement arrangements on the high strength of concrete and to present the quantitative values. To complete this research, two types of concrete strengths (40 MPa and 60 MPa), two types of reinforcing bar diameters (10 ㎜ and 13 ㎜), and seven types of specimens with or without reinforcement arrangements were prepared and tested for compressive strength. As a result, the strength of the cores containing the reinforcement can be predicted to have 82% - 94% of the strength of the cores without reinforcement.
The purpose of this study is to establish a reasonable analytical method for the estimation of overall behavior characteristic from cracking to yielding of rebar and crushing of concrete and seismic performance of reinforced concrete shear wall with high-strength reinforcing bar. A total of 8 specimens of reinforced concrete walls which have constant aspect ratio and a variety of variables such as reinforcement ratio, reinforcement yielding strength, reinforcement details, concrete design strength, section shape and whether lateral restraint hoop were selected and the analysis was performed by using a non-linear finite element analysis program (RCAHEST) applying the proposed constitutive equation by the authors. The mean and coefficient of variation for maximum load from the experiment and analysis results was predicted 1.04 and 8%. The mean and coefficient of variation for displacement corresponding maximum load from the experiment and analysis results was predicted 1.17 and 19% respectively. The analytical results were predicted relatively well the fracture mode and the overall behavior until fracture for all specimens. These results are expected to be used as basic data for application of high-strength reinforcing bar to design codes in the future.
This paper describes the experimental results for the structural performance of full-scale coupling beams with different reinforcement layout (diagonal and horizontal). For the reinforcements of the coupling beams, high-strength steel bars(SD500 and SD600) were used in order to improve workability and economic feasibility. The rigid steel frames and linked joints were used to maintain the clear span length (distance between both shear walls) of the coupling beam during the cyclic loading. Experimental results indicated that the diagonally reinforced coupling beam specimen could exhibit more ductile behavior compared to horizontally reinforced specimen. ACI318-14 code is applicable to design of coupling beam with diagonally reinforcement, however, that is overestimating the strength of horizontally reinforced coupling beam. It is remarkable that effective elastic stiffness values of both reinforcement details coupling beam significantly lees than ASCE 41-13.
In this study, to evaluate the performance of the sleeve structure for high strength reinforced joints and to develop more economical and practical for high-strength reinforced joints sleeve.
본 연구는 고강도 철근을 확대머리 이형철근으로 사용하는 경우 정착길이 효과에 관한 실험 연구이다. 현행 기준에서는 확대머리 이형철근의 정착길이를 산정하는 식에서 철근의 설계기준강도를 400 MPa로 한정하고 있다. 고강도 철근에 대한 연구결과가 충분하지 않기 때문에 이러한 규정이 명시된 것이다. 따라서 본 연구에서는 설계기준 항목강도 600 MPa의 철근으로 확대머리 이형철근을 제작하여, 변수별 실험연구를 수행하였다. 실험은 철근의 정착길이, 철근의 개수, 그리고 확대머리의 형상 등의 변수로 계획하였다. 실험체는 정착길이가 긴 L형과 정착길이가 짧은 S형으로 분류하고, 확대머리의 형상은 원판형(A형)과 원뿔형(B형)으로 구분하였다. L형 실험체는 원판형 확대머리를 대상으로 철근 개수가 1∼3으로 변하는 3개의 실험체와 S형 실험체는 원판과 원뿔형 확대머리 형상에 대하여 정착길이를 L형의 50%, 45%, 40%, 35%로 변화한 실험체를 계획하였다. L형(LA형) 3개, SA형 4개, SB형 4개 등 총 11개의 실험체를 인발실험을 하였다. 실험결과는 콘크리트구조기준(부록 II)의 정착길이 산정 규정에 따라 평가하였으며, 그 결과 항복강도 600 MPa의 철근을 사용한 확대머리 이형철근은 현행기준의 설계식을 적용하여 설계할 수 있음을 보였다.
This paper describes the flexural performance of concrete and strain-hardening cement based composite (SHCC) beams reinforced with normal and high-strength steel bar to evaluate the effect of reinforcing bar strength and cement composite type. The present investigation shows the potential of high-strength structure materials used of high-strength reinforcing bars with SHCC. And superior mitigation of crack-damage is observed reinforced SHCC beams than reinforced concrete beams
본 논문에서는 반복하중이 작용하는 고강도 모르타르 충전식 슬리브 철근이음의 강성에 대한 합리적인 검토를 하기 위하여 100여개 고강도 모르타르 충전식 슬리브 철근이음의 실험데이터를 이용하여 슬리브 철근이음이 보유하고 있는 구조인자가 반복 하중이 작용하는 슬리브 철근이음의 강성에 미치는 효과를 파악하였고, AIJ 규준에 정해져 있는 강성 등급을 충족시키는 최소한 의 조건에 대하여 평가한 결과, SD350과 SD400 철근을 매입한 모르타르 충전식 주물 슬리브 철근이음에서 fg*(L/d)가 470MPa 이상이 된다면 AIJ 규준의 SA급 강성, fg*(L/d)가 340MPa 이상이 된다면 AIJ 규준의 A급 강성을 최종파괴형식과 슬리브 형상에 상관없이 확보할 수 있는 것으로 나타났다. 또한 SD500 철근을 매입한 모르타르 충전식 슬리브 철근이음에서 주물슬리브와 강관 슬리브를 사용한 경우는 fg*(L/d)가 400MPa 이상이 된다면 AIJ 규준의 A급 강성을 확보할 수 있는 것으로 나타났다.
본 연구에서는 고강도 모르타르 충전식 기계적 슬리브 철근이음에 대한 단조가력 하에서의 강성을 보다 적절하게 평가하기 위하여, 슬리브 철근이음의 주요한 구조요소가 미치는 단조가력 하에서의 철근이음 강성에 대한 영향을 검토하였고 AIJ 규준에서 설정한 단조가력 하에서의 슬리브 철근이음에 대한 강성 기준과 비교평가하였다. 이것을 위하여 단조가력을 실시한 국내외 189여개 고강도 모르타르 충전식 기계적 슬리브 철근이음의 실험데이터를 조사하고 그 실험결과를 분석하였다. 그 결과, AIJ 규준에서 규정하는 목표 강성을 확보하는데 필요한 fg(L/d)의 한계값을 철근의 종류와 슬리브의 종류에 따라서 각각 제시하였다.
본 연구에서는 보다 자유로운 형상의 슬리브를 만들 수 있는 구상흑연 주철을 이용하여 보다 효과적으로 구조성능을 발휘하면서 SD500 고강도 철근에 적합하게 개발된 모르타르 충전식 슬리브 철근이음을 대상으로 실물크기의 19개 실험체를 제작하여 반복가력실험을 실시하였다. 그리고 강도, 강성, 슬립을 중심으로 한 구조성능에 대하여 본 실험의 주요한 변수에 따르는 영향을 분석하고, 국내기준을 비롯한 주요기준의 요구 성능과 비교하였다. 본 연구결과에서는 SD500 고강도 철근용으로 개발한 모르타르 충전식 슬리브 철근이음은 반복하중이 작용하는 경우에 대하여 국내기준을 비롯한 주요기준에서 요구하는 구조성능을 보유하고 있는 것이 확인되었고, SD500 고강도 철근용 모르타르 충전식 슬리브 철근이음에 대한 구조설계 기준 정립에 필요한 정량적인 기술 데이터를 제시하였다.
본 연구에서는 SD500 고강도 철근에 적합한 강관 스플라이스 슬리브를 개발한 후에 실물크기의 20개 실험체를 제작하여 가력실험을 실시하였다. 그리고 강도를 비롯한 구조성능을 철근의 정착길이, 슬리브의 타입, 철근의 규격과 같은 실험변수에 따른 영향을 분석하고, 국내기준을 비롯한 주요기준에 따라서 비교, 평가하였다. 실험 결과는 SD500 고강도 철근용으로 개발된 강관 스플라이스 슬리브 철근이음은 주요기준에서 요구하는 구조성능을 가지고 있는 것으로 확인되었고 SD500 고강도 철근용 슬리브 철근이음에 대한 구조설계 기준 확립을 위한 기술적 자료를 제시하였다.