The purpose of this study is to experimentally analyze the seismic performance of beam-column specimens with vertical irregular, which were reinforced with RHS (Replaceable steel haunch system). a steel haunch system. To evaluate the seismic performance of the RHS, three specimens were manufactured and subjected to cycle loading tests. Retrofitted specimens have different beam-upper column stiffness ratio as a variable. The stiffness ratio of beam-upper column were considered to be 1.2 and 0.84. As a result of the test, the specimen reinforced with RHS showed improved maximum load and effective stiffness, and energy dissipation capacity compared to the non-retrofitted specimen with same beam-upper column stiffness ratio. The specimen with 0.84 beam-upper column stiffness ratio showed improved performance than the specimen with 12.
Nonlinear static analysis and preliminary evaluation were performed in this study to evaluate the seismic performance of unreinforced masonry buildings subjected to various soil conditions based on the revised Korean Building Code. Preliminary evaluation scores and nonlinear static analyses indicated that all buildings were susceptible to collapse and did not reach their target performance. Therefore, retrofit of those building models was carried out through a systematic procedure to determine areas to be strengthened. It was possible to make most building models satisfy performance objectives through the reinforcement alone of damaged external shear walls. However, the application of a preliminary evaluation procedure to retrofit design was found to be too conservative because all the retrofitted building models verified with nonlinear static analysis failed to satisfy performance objectives. Therefore, it is possible to economically retrofit unreinforced masonry buildings through the fortification of external walls if a simple evaluation procedure that can efficiently specify vulnerable parts is developed.
최근 국내의 지진발생 빈도가 증가함에 따라, 지진피해 저감 시스템 중 가장 효율이 높은 제진방식의 문제점을 해결하며 댐퍼의 복원성과 에너지 소산 능력을 증가시켜 잔류변형 감소와 사용성 증대 효과를 발생시키는 새로운 제진설계 방식이 필요하다. 본 연구에서는 학교 등 기존에 시공된 비내진상세 철근콘크리트 구조물의 지진에 의한 뒤틀림 방지, 횡방향 변위제어 및 진동저감을 위하여 구조물의 양 옆에 원형강봉댐퍼를 설치하는 시스템을 제안하고, 2층 철근콘크리트골조 실험체를 반복횡 하중 가력 하여 내진성능을 평가하였다. 무보강 및 보강 실험체들의 실험결과를 비교한 결과 외부보강용 원형강봉댐퍼 시스템이 2층 철근콘크리트 골조의 강성과 에너지소산면적을 증가시켜 내진성능을 증가시킴을 확인하였다. 또한 원형강봉댐퍼가 지진 에너지를 소산하여 지진력을 흡수함을 확인하였다.
This study investigates the seismic performance of a hybrid seismic energy dissipation device composed of a viscoelastic damper and a steel slit damper connected in parallel. A moment-framed structure is designed without seismic load and is retrofitted with the hybrid dampers. The model structure is transformed into an equivalent simplified system to find out optimum story-wise damper distribution pattern using genetic algorithm. The effectiveness of the hybrid damper is investigated by fragility analysis of the structure with and without the dampers. The analysis results show that after seismic retrofit the probability of reaching damage states, especially the complete damage state, of the structure turn out to be significantly reduced.
Existing reinforced concrete building structures have seismic vulnerabilities due to their seismically-deficient details resulting in non-ductile behavior. The seismic vulnerabilities can be mitigated by retrofitting the buildings using a fiber-reinforced polymer column jacketing system, which can provide additional confining pressures to existing columns to improve their lateral resisting capacities. This study presents dynamic responses of a full-scale non-ductile reinforced concrete frame retrofitted using a fiber-reinforced polymer column jacketing system. A series of forced-vibration testing was performed to measure the dynamic responses (e.g. natural frequencies, story drifts and column/beam rotations). Additionally, the dynamic responses of the retrofitted frame were compared to those of the non-retrofitted frame to investigate effectiveness of the retrofit system. The experimental results demonstrate that the retrofit system installed on the first story columns contributed to reducing story drifts and column rotations. Additionally, the retrofit scheme helped mitigate damage concentration on the first story columns as compared to the non-retrofitted frame.
Earthquakes is impossible to predict and occur within very little or no warning. They cause significant damage to property and inflict large human casualties. Seismic retrofit for non-seismic design RC frame has been studied over the years. Although there are many seismic retrofit methods, the seismic retrofit methods are increased weight and physical damage to structures. This study evaluates the seismic performance of RC frame retrofitted with velcro. The specimens were made scale down of actual steel structures, and displacement loads were applied in the trasnverse direction.
In this study, shaking table test was carried out to evaluate the seismic behavior and performance of low-rise reinforced concrete (RC) piloti structures with and without retrofit. The specimens were designed considering the characteristics of existing building with pilotis such as natural period, distribution factor of strength and stiffness between columns and core wall on the first soft story. The test for the non-retrofit specimen showed that damage was concentrated on the stiffer member on the same floor as the core wall failed by shear fracture whereas columns experienced slight flexural cracks. Considering the failure mode of the non-retrofit specimen, the retrofit method using steel rod damper was presented for improving the seismic performance of piloti structures. The results of the test for retrofit specimen revealed that the retrofit method was effective for controlling the damage as the main RC structural members were not destroyed and most of input energy was dissipated by hysteretic behavior of the damper.
The friction damper can be used for improving the seismic resistance of existing buildings. The damper is often installed in bracing members. The energy dissipation capacity of the damping systems depends on the type of the structure, the configuration of the bracing members, and the property of dampers. In Korea, there are numerous low- to mid-rise reinforced concrete moment frames that were constructed considering only gravity loads. Those frames may be vulnerable for future earthquakes. To resolve the problem, this study developed a toggle bracing system with a high density friction damper. To investigate the improvement of reinforced concrete frames after retrofit using the developed damped system, experimental tests were conducted on frame specimens with and without the damped system. The results showed that the maximum strength, initial stiffness and energy dissipation capacity of the framed with the damped system were much larger than those of the frame without the damped system.
This study proposed proposes a retrofitting method using an H‐beam frame to improve the seismic performance of non‐seismic designed reinforced concrete frames. To evaluate the seismic performance with the H‐beam frames, a cyclic lateral load test was performed and the experimental result was compared with the bared frame, and a masonry infilled RC frame. The results was were analyzed regarding aspects of the load‐displacement hysteresis behavior, effective stiffness, displacement ductility, and cumulative energy dissipation. AlsoIn addition, it was possible to prove both an increase of in the maximum load capacity, effective stiffness, and energy dissipation capacity using the H‐beam frame.
This study is the research appling the representative Displacement-Based Design which is the basic concept of Direct Displacement Based Design proposed by Chopra and Goel to original Reinforced Concrete moment frame and determining the thickness of retrofit Steel Jacket about the Maximum design ground acceleration, and developing the more improved Algorithm as well as program by the Retrofit Design method and Nonlinear analysis by the Performance design method before and after reinforcement appling the determined retrofit thickness. It also shows the result of the seismic performance improvement which is the ratio of seismic performance appreciation result yield displacement 19%, yield strength ratio 24%, displace ductility ratio the maximum 27% comparing Multi degree of freedom, column member of Reinforced Concrete with the performance improvement column member considering the thickness of the determined Steel Jacket. The developed Algorithm and program are easy to apply seismic design and application to the original Reinforced Concrete building, at the same time, it applicate to display well the design result of Target displacement performance level about nonlinear behavior.
본 연구에서는 시간종속요소를 이용하여 상부벽식-하부골조구조가 고려된 중 저층 철근콘크리트 구조물의 동적응답을 조사하였다. 시간종속요소란 사용자가 원하는 시간간격에서 부재를 활성화할 수 있는 진보된 요소로써 기존의 수행되었던 실험을 통해 가장 우수한 성능을 보인 채널형 비좌굴가새가 해석에서 보강요소로 고려되었다. 시간종속요소로 고려된 비좌굴가새는 1차 지진하중에 의해 구조물이 손상된 후에 2차 지진하중이 발생하기 전에 모멘트골조에 설치, 보강된 것으로 가정되었다. 이러한 가정을 바탕으로 내진설계가 고려되지 않은 5층 콘크리트 건물에 연속지진하중의 적용을 통하여 시간종속요소의 영향에 따라 구조물의 동적응답을 비교하였다. 2차 지진파가 발생했을 때 비좌굴가새를 활성화시키는 것은 1차 지진하중에 의해 손상이 집중된 모멘트골조의 변형을 크게 감소시키는 것으로 조사되었다. 그러나 전단벽시스템은 BRB시스템이 활성화된 이후에도 손상이 증가하는 것으로 나타났다. 모멘트골조의 보강효과에 비해 전단벽시스템의 누적손상이 매우 미세하기 때문에 연속지진하중에 대한 BRB시스템은 효과적인 보강방법으로 조사되었다.
본 연구는 기존 철근콘크리트 구조물에 대하여 대표적인 변위-기반 설계법인 Chopra&Goel 이 제안한 직접변위-기반 설계법의 기본개념을 적용하여 최대 설계지반 가속도에 대한 보강 Steel Jacket의 두께를 결장하고, 결정된 보강 두께를 적용하여 보강전 후 성능설계기법에 의한 비선형 해석 및 보강설계법에 의한 보다 개선된 알고리즘 및 프로그램을 제시하였다. Steel Jacket 보강된 철근콘크리트 기둥에 대한 설계 변위 추정을 위해 Steel Jacket 보강된 철근콘크리트 부재의 비선형 층상화 세그멘트 해석 모델을 제시하고, 성능기반설계에 의한 성능개선설계를 위하여 목표성능변위 및 설계자전가속도 조건에 대해 직접 변위-기반 설계 방법 및 변위계 수법에 의한 내진성능개선 설계 방법을 제시하였다. 적용 예에서 본 방법은 기존 철근콘크리트 기둥과 비교하여 성능개선설계 결과 보강 전에 비해 변위 연성비 및 변위성능에서 크게 개선된 성능설계 결과를 제공해 주었다.
본 논문에서는 중 약진 지역에서 중력 저항시스템인 중간 모멘트골조로 설계된 3층, 6층 RE 플랫플레이트 구조물을 KBC 2005를 만족하도록 RC구조물에 강판과 가새/ BRB 등의 보강방법을 적용하여 보강하고, 내진성능을 평가하여 보강 효과를 검증하였다. 비탄성 정적해석과 동적해석 결과에 따르면 내진 보강된 구조물은 강도와 강성이 크게 향상된 것으로 나타났다 특히 기둥을 철판으로 보강한 경우 슬래브를 철판으로 보강하여 조기 뚫림 전단파괴를 방지함으로써 강도를 크게 향상할 수 있다. BRB로 보강된 구조물은 Brace로 보강된 구조물보다 다소 연성적 거동을 보였으며, 그 효과는 3층 모델에서 현저하게 나타났다.
본 연구에서는, 기존 철근 콘크리트 구조물에 적용된 직접 변위-기반 설계법을 적용 FRP 피복 보강된 성능개선 콘크리트 부재에 대한 정밀 비선형 휨 해석 및 내진성능설계의 구체적 알고리즘을 제시하였다. 비선형 휨 해석의 정밀 예측을 위하여 콘크리트 및 FRP 복합재료의 다축 구성관계를 고려하였으며, Chopra 등 (1999)이 제안한 직접 변위-기반 설계법(DDM)을 개선하여 철근콘크리트 기둥에 대한 성능개선을 위한 FRP 피복 보강을 위한 성능설계 알고리즘을 제시하였다. 제시된 직접 변위-기반 설계법은, 변위계수법과 비교하여, 비선형 거동이 큰 경우에도 목표 변위 성능 값에 대한 정확한 추정을 해준다. 이는 변위계수법이 항복 이전의 유효탄성계수를 사용하는 반면, 직접 변위-기반 설계법은 유효탄할선탄성계수를 고려하고 있어, 목표 변위에 따른 성능설계 평가에 있어서 보다 높은 연성비의 거동을 반영하고 있기 때문인 것으로 평가된다.
이전 논문에서 미 중부 및 동남부 지역의 전형적인 다경간 단순효와 다경간 강거더 연속교의 지진 응답을 연구하였으며, 이런 교량에서 덱 사이의 충돌과 큰 연성이 요구되는 기둥은 취약하여 손상을 입을 수 있다는 것을 보여주었다. 더구나, 고정 및 가동 교조장치는 강한 지진운동에 쉽게 피해를 입을 수 있다. 이 논문에서는 몇 개의 개선된 고무 베어링, 납-고무 베어링 그리고 제지선을 사용하여 전형적인 다경간 단순교와 다경간 강거더 연속교의 지진 응답을 평가하였다. 납-고무 베어링은 지진에 취약한 전형적인 교량의 응답을 개선하는데 효과적인 방법으로 평가되었다. 고무 베어링은 기둥의 요구량을 줄이지만, 다경간 단순교 강거더 교량에서 덱 사이의 강한 충돌을 유발시킨다. 제지선은 일반적으로 사용되지만 다경간 단순교와 다경간 연속교의 지진에 대한 손상을 절감하는데 중간정도의 효과를 보여주었다.
본 연구의 목적은 유사동적실험에 의한 섬유보강 원형 RC교각의 내진성능평가를 위한 연구로서 수원시에 위치한 내진교량인 하길교를 대상모델로 하였으며, 도로교 표준시방서의 내진설계규정이 적용되지 않은 비내진교각시험체 2본 및 내진성능향상을 위한 섬유보강시험 4본, 즉 총 6본에 대하여 유사동적실험을 수행하였다. 보강공법으로는 유리 탄소섬유 보강공법을 사용하였으며, 실험변수로는 입력지진동, 섬유고방유무로 하였다. 그리고 내진성능평가 방법은 입력 및 소산에너지, 변위 연성도가 분석되었다. 본 실험의 결과 유리 섬유로 보강된 비내진시험체의 변위연성도 KHC인공지진파에 대하여 7.7~9.0정도의 값으로 충분한 내진성능을 확보하고 있는 것으로 평가되었다.
지진하중에 의한 상부구조의 낙교는 최근 발생된 지진등에서 알수 있듯이 교각파되와 더불어 교량의 전체적인 붕괴를 유발하는 주요한 원인 것으로 나타났으며 또한 충돌현상은 이러한 낙교를 발생시키는 주된요인인 것으로 밝혀졌다. 따라서 본 연구에서는 이러한 충돌현상을 비롯한 교량의 교축방향거동에 영향을 미치는 인자 즉 교각의 비선형성 기초의회전 및 병진운동 교대의 작용 등을 고려하고 최근 낙교방지대책으로 널리 적용되고 있는 restrainer로 보강된 교량시스템의 거동을 해석할 수 있는 모형을 개발하였다 개발된 해석모형을 바탕으로 다양한 지진하중에 의한 교량시스템의 교축방향 거동특성과 restrainer의 보강효과를 분석하였으며 restrainer의 여유길이와 강성변화에 따른 인접 진동계간의 응답특성을 분석하였다 restrainer의 보강효과를 분석하였으며 restrainer의 여유길이와 강성변화에 따른 인접진동계간의 응답특성을 분석하였다. restrainer로 보강된 교량시스템의 충돌에 따른 응답특성을 살펴본 결과 응답의 크기뿐만아니라 응답의 이력자체가 상이한 거동특성을 나타내는 것으로 밝혀졌다. 또한 restrainer의 보강에 따른 변위억제효과는 중진의 경우 restrainer의 여유길이 짧을수록 restrainer의 강성이 클수록 뛰어난 것으로 나타났으나 강진에서는 restrainer의 파단에 대한 대책을 함께 고려하여야 할 것으로 분석되었다.
In this study, the effect on seismic performance of Binding Column Method(BCM) system was empirically evaluated. Four column models that were confined by different forces and one rare column model as a control were manufactured for cyclic loading test. As a result, in the column retrofitted with BCM, the ultimate displacement and load were increased about 2.5 and 2.0 times. Also, the energy-dissipating capacity of the retrofitted model was improved, compared to a rare column model.
본 연구에서는 TS 내진보강공법의 내진보강 효과 검증을 목적으로 7개의 지진파에 대한 TS 댐퍼(Tension Spring-Damper)로 내진보강된 구조물의 비선형 시간이력해석을 수행하였다. 비선형 시간이력 해석을 통해 얻어진 무보강 구조물의 층간변위비와 에너지소산 양과 비교한 결과 층간변위비가 약 30% 가량 감소하였고, 구조체를 통한 에너지 소산의 양은 반감되었다. 이를 통해 TS 내진보강공법의 제진성능이 우수함을 확인하였다.