검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 74

        1.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to experimentally analyze the seismic performance of beam-column specimens with vertical irregular, which were reinforced with RHS (Replaceable steel haunch system). a steel haunch system. To evaluate the seismic performance of the RHS, three specimens were manufactured and subjected to cycle loading tests. Retrofitted specimens have different beam-upper column stiffness ratio as a variable. The stiffness ratio of beam-upper column were considered to be 1.2 and 0.84. As a result of the test, the specimen reinforced with RHS showed improved maximum load and effective stiffness, and energy dissipation capacity compared to the non-retrofitted specimen with same beam-upper column stiffness ratio. The specimen with 0.84 beam-upper column stiffness ratio showed improved performance than the specimen with 12.
        4,000원
        3.
        2023.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The column-tree type steel beam-column connections are commonly used in East Asian countries, including Korea. The welding detail between the stub beam and column is similar to the WUF-W connection; thus, it can be expected to have sufficient seismic performance. However, previous experimental studies indicate that premature slip occurs at the friction joints between the stub and link beams. In this study, for the accurate seismic performance evaluation of column-tree type moment connections, a moment-slip model was proposed by investigating the previous test results. As a result, it was found that the initial slip occurred at about 25% of the design slip moment strength, and the amount of slip was about 0.15%. Also, by comparing the analysis results from models with and without the slip element, the influence of slip on the performance of overall beam-column connections was examined. As the panel zone became weaker, the contribution of slip on overall deformation became greater, and the shear demand for the panel zone was reduced.
        4,000원
        4.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        콘크리트 충전강관은 국부좌굴을 방지하고 내화성이 향상되기 때문에 건설현장에서 많이 적용되며 휨성능을 향상시 키기 위해 강관 내부에 철근을 보강하여 사용한다. 그러나 철근은 부식되며 내구성이 저하되기 때문에 이를 대신할 소재에 대 한 연구가 진행되고 있다. 탄소섬유보강근은 철근에 비해 경량이며 고강도와 내부식성이 우수하다는 이점이 있다. 그러나 임계 온도가 250℃로 철근의 임계온도인 538℃에 비해 현저히 낮기 때문에 내화피복이 필요하다. 따라서 열전달해석을 통해 탄소섬 유보강근을 사용하였을 때 온도분포를 확인하고 P-M상관도를 도출하여 적용 가능여부를 확인하고자 한다. 해석결과 내화성능을 확보하기 위해 콘크리트 피복두께 40mm, 뿜칠내화피복재 30mm를 적용하거나 콘크리트 피복두께 60mm, 뿜칠내화피복재 20mm 를 적용하면 3시간 내화성능을 만족하는 것으로 평가되었다.
        4,200원
        5.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        모듈러 건축물은 철근콘크리트 및 철골 구조물에 비하여 상대적으로 경량이고, 단위 모듈간 기둥의 일체성을 기대하기 어려운 구조적 특성을 가진다. 이와 같은 구조적 특성은 모듈러 건축물의 높이가 높아짐에 따라 바람 및 지진과 같은 횡력저항성능에 직접적인 영향을 미친다. 본 연구에서는 횡력저항성능을 향상시키기 위해 긴장재를 활용한 모듈러 구조시스템을 제안하였다. 모듈러 구조시스템을 구성하는 주요 요소인 포스트텐션 기둥-바닥 접합부는 셀프 센터링 거동을 유도하기 위한 형상 및 상세를 가진다. 포스트텐션 기 둥-바닥 접합부의 이력 거동을 상세히 파악하기 위해 유한요소해석을 수행하였으며, 그 결과 초기 긴장력 및 보-기둥 접합부의 접합 조건에 따라 이력 거동은 확연한 차이를 보이는 것으로 나타났다.
        4,000원
        7.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        When reinforcing an existing reinforced concrete beam-column building with a precast concrete panel, special connection between the PC member and the RC member is required to solve the time dependent deformation of the RC member and to receive the large shear forces. The aim of this study is to obtain the shear strength of upper connection between the existing RC beam-column and infilled PC wall panels in experimentally and theoretically. Thus, the static shear loading tests were conducted on the 6 specimens with the plate connection. Shear failure was resulted from the weakest portion of interior PC panel, exterior RC, and the connection, when the PC portion which located at the center of specimen was pulled upward from the bottom. T he experimental result was compared with analytical result from ACI 318M-14 Chapter 17 for the shear strength of post-installed anchor and PCI Handbook 7th edition 6.8 Structural Steel Corbel (PCI Design Handbook 7th edition, 2010) for the strength of cast-in H-beam. The analytical and experimental results show final failure at the same location. The failure loading of experiment showed larger than average 6% to that of the analysis.
        4,500원
        8.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents the resizing method of columns and beams that considers column-to-beam strength ratios to simultaneously control the initial stiffness and ductility of steel moment frames. The proposed method minimizes the top-floor displacement of a structure while satisfying the constraint conditions with respect to the total structural weight and column-to-beam strength ratios. The design variable considered in this method is the sectional area of structural members, and the sequential quadratic programming(SQP) technique is used to obtain optimal results from the problem formulation. The unit load method is applied to determine the displacement participation factor of each member for the top floor lateral displacement; based on this, the sectional area of each member undergoes a resizing process to minimize the top-floor lateral displacement. Resizing members by using the displacement participation factor of each member leads to increasing the initial stiffness of the structure. Additionally, the proposed method enables the ductility control of a structure by adjusting the column-to-beam strength ratio. The applicability of the proposed optimal drift design method is validated by applying it to the steel moment frame example. As a result, it is confirmed that the initial stiffness and ductility could be controlled by the proposed method without the repetitive structural analysis and the increment of structural weights.
        4,000원
        9.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To overcome the weakness of spread foundation in large space structure, the research of precast pile for replace spread foundation have been conducted. The new type of joint between PHC pile and steel column is named HAT Joint(Hollow hAlf-sphere cast-sTeel Joint). It connected PHC Pile by bolt that verification of bolt connection should be accomplished. In this paper, pull-out test and flexural performance for HAT Joint to verifying the bolt connection is explained. As a result, the pull-out and flexural capacities of bolt were checked to use in real structure. Furthermore, the equation of pull-out strength was proposed.
        4,000원
        10.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents a foundation pile to steel column connection that can resist large magnitude of moment and that can be easy installed. The developed joint has spherical shape and it is given the name HAT joint to mean Hallow half-sphere steel joint. Four types of HAT joints are developed. Namely, H-type, T-type, P-type and K-type. In this paper I will talk about the performance assessment of T-type(Tube Column) and P-type(Pile Column) of HAT joints with finite element analysis and experiment on a full scale model is presented.
        4,000원
        11.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        So far, square concrete filled tubular(CFT) columns have been used in a limited width thickness ratio. The reason is that local buckling occurs in steel tube easily. Once the local buckling occurs, the confinement effect of steel tube on concrete disappears. In this study, we developed welded built-up square steel tube with reinforcement which are placed at the center of the tube width acts as an anchor. 3 specimens of slender welded built-up square CFT columns and 3 specimens of slender welded built-up square steel tube columns were manufactured with parameters of width(B) of steel tube, width thickness ratio(B/t). we conducted a experimental test on the 6 specimens under eccentric load, and evaluated the structural resistance and behavior of 6 specimens.
        4,000원
        12.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In Part I, we disccussed of joint between PHC pile and steel column in foundation of large space structures, one prototype of a joint of PHC pile to steel pipe column was suggested on the basis of analytical studies. In this paper, I explain the Joint of PHC pile to steel tube column and more detail of analysis
        4,000원
        13.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To overcome disadvantages of usual spread foundation in large space structure, some prototypes of a joint of the PHC pile to steel pipe column that directly connects a column to a PHC pile are analytically studied. With the consideration of strength requirement and stress concentration of joint of the PHC pile to column, we suggest the most appropriate one.
        4,000원
        14.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Main topics in this study is a new structural detail for connection between H-Steel or SRC column and flat plate slab. We carried out to evaluate the punching shear performance of H-steel or SRC column + RC slab system for vertical load and lateral load. From the test results structural characteristics - yield moment, yield rotation, maximum moment, deformation capabilities ect. - are obtained and evaluated. In this paper as a shear reinforcement for supporting region of plate closed stirrup type and shear band are used, and their test results are compared.
        4,000원
        15.
        2014.04 구독 인증기관·개인회원 무료
        An experimental study was carried out to evaluate the punching shear performance of H-steel column + RC slab system for vertical load. Three specimens were constructed for interior column-slab system. All specimens were the same configuration and material properties except for columns such as RC column+flat plate slab and H-Steel column+flat plate slab. From the test results structural characteristics (maximum proof stress, maximum displacement, deformation capabilities and so on) are obtained and evaluated.
        16.
        2014.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The flat plate slab system have many good features, which are design flexibilities, saving of story-height and economy of construction etc. But the study of flat plate slab system for H-steel column have been rare both at home and abroad. Recently high-rise residential and commercial buildings have been constructed in urban areas in Korea. The suggested dowel connection system is more likely to adoptable because it remarkably contribute to save inter story height and also to have many advantages compared with conventional steel works such as H-Steel frame + Deck plate slab system. This study aims at developing design method and program for connection between H-Steel column and flat plate slab system, which contribute to save significantly inter-story height.
        4,000원
        17.
        2014.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study presents an experimental study of the structural behavior for steel plate-concrete column-to-steel girder connections. Experiments were carried out to investigate the moment-rotation characteristics, failure behavior and ultimate moment capacity of these connections. The results of this experimental study involving three welded moment-resisting connections subjected to cyclic loading are presented. The specimens were fabricated at full scale to evaluate their hysteretic behavior. A description of the test specimens, the details of the joint, the test system and the testing methods are described. The test results showed that the structural behavior of these composite connections was influenced by the connection details.
        4,000원
        18.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        For the artistic column used by Glass Fiber Reinforced Plastic(GFRP), the connection of steel with GFRP were needed. Due to the fabricating characteristics of hand laminating, GFRP surfaces had to be connected. Because there were no existed data of these connection, experimental study has to be followed so that the structural strength and buckling mode could be investigated. In this paper, therefore, the axial tests of steel with GFRP were performed. The connection of GFRP's surfaces could be also tested as well. As a result, it could be figured out that the strength of these connections were determined by the adhesive strength.
        4,000원
        19.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In recent years, the construction of high-rise buildings are promoted. According to these, there are many needs about new technologies to strengthen the building performance and high-strength steel is regarded as one of these for promoting building performance. In Korea, high-strength steels which stress are over 600MPa are on market and in aborad, super high-strength steels over 1000MPa are developing and they expected to promote the building performance. But there are still doubts about applying high-strength steel members because of size effect and worry of brittle fracture. In this reports, we propose results of performance and analysis tests for use with general steel. We propose the characteristic of high-strength steels first and next the results of performance test to show they satisfy the performance that designers expect. And last, we compare the results of test and analysis for acquire the alanysis reliability in non-linear analysis with high-strength steels.
        4,000원
        20.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 진행되고 있는 건축 프로젝트는 기존의 정형적인 구조계획에서 벗어나 점차 복합적이고 다양한 형태를 지향하고 있다. 이와 같은 새로운 건축 트렌드 속에서, 비정형 건축물의 구조 시스템을 효율적으로 현실화하여 골조의 직교성을 해체시키는 기술에 대한 연구의 필요성이 대두되고 있다. 비정형 건축물의 중요한 구조적 특징 중 하나로 경사기둥의 빈번한 적용을 들 수 있다. 경사기둥은 접합된 보에 추가적으로 모멘트와 축력을 전달하므로, 이러한 현상이 골조 및 보-기둥 접합부의 거동에 어떠한 영향을 미치는지를 실험 혹은 해석을 통해 검증할 필요가 있다. 그러나 수직기둥-보 접합부에 비하면 경사기둥-보 접합부에 대한 연구는 현재까지 충분한 연구가 이루어지지 않고 있는 실정이다. 따라서 본 연구에서는 비선형해석 및 유한요소해석을 사용하여 경사기둥을 포함한 보-기둥 접합부의 성능을 평가하였다. 경사기둥을 포함한 철골모멘트 골조의 비선형정적해석을 통하여 골조 전체의 거동을 분석하였고, 경사기둥-보 접합부 모델의 유한요소해석을 통해 좌굴거동 및 취성파단 잠재성을 검토하였다.
        4,000원
        1 2 3 4