One of the options for spent fuel dry storage systems is to store them in canisters using metal or concrete casks close to shore. The interaction between the austenitic stainless steel and the chloride atmosphere generated from the sea creates detrimental conditions leading to chloride induced stress corrosion cracking (CISCC) in the canister. The corrosion integrity of the canister in the concrete cask is very important because the canister is sealed and used for a long period of time. A canister made of austenitic stainless steel has several welding lines on the wall and lid, which are generated during the welding process and have high residual tensile stress. The interaction between the austenitic stainless steel and the chloride atmosphere generated from the sea creates detrimental conditions leading to chloride induced stress corrosion cracking (CISCC) in the canister. The corrosion integrity of the canister in the concrete cask is very important because the canister is sealed and used for a long period of time. In order to evaluate such soundness, an accelerated test capable of simulating the CISCC crack propagation phenomenon of the canister weld is required. In this study, a test device for performing the CISCC simulation test was constructed using the DCPD device. The direct current potential drop (DCPD) technique is a widely accepted method of monitoring crack initiation and growth in controlled laboratory tests. Total 10 types of test specimens with varying welds, base metal, salinity and stress were selected and a sealed chamber with DCPD test apparatus were designed and constructed to evaluate them. The chamber for CISCC simulation was manufactured as a sealed with a solution containing 10% MgCl2. A 1/2 CT specimen with precracked pre-cracks was loaded into the prepared container, and gauze was attached from the bottom for smooth delivery to the specimen to facilitate penetration of chloride. After the test, the measured DCPD data were correlated with Electron Back scattered Diffraction (EBSD) data.
본 연구는 사료내 비테인, 글라이신, 그리고 콜린의 혼합 첨가가 고온 스트레스 환경에서 노령 산란계의 생산성, 난품질, 면역 반응 및 혈액성상에 미치는 영향을 조사하고자 수행되었다. 총 336마리의 86주령 로만 갈색종 노령 산란계를 6처리 7반복, 반복당 8수씩 임의 배치하였다. 대조구는 모든 영양소 및 에너지 요구량을 충족하거나 초과하도록 배합하였다. 대조구를 제외한 사료 처리구는 0.2% 비테인, 0.62% 글라이신, 그리고 0.32% 콜린을 단독, 두 가지 혼합, 혹은 세 가지 혼합으로 사료내 첨가하였다. 실험은 8주 동안 진행되었으며, 모든 산란계는 매일 8시간 동안 평균 온도 31.7±1.7℃, 습도 57%의 고온 스트레스 조건에서 사양되었고, 이외 시간에는 평균 온도 27±1.3℃, 습도 57%에서 사양하였다. 실험 결과, 비테인, 글라이신 및 콜린의 첨가는 생산성, 난품질, 그리고 면역 반응에 유의적인 영향을 미치지 않았다. 그러나, 0.2% 비테인과 0.62% 글라이신을 혼합 첨가한 처리구에서 혈청 알라닌 아미노전이효소 농도가 유의적으로 감소했다. 하지만, 다른 혈청 지표들은 처리간 유의적인 차이가 관찰되지 않았다. 결론적으로, 현재 수준에서 사료내 비테인, 글라이신, 그리고 콜린의 혼합 첨가는 고온 스트레스 환경에서 사양되는 노령 산란계의 생산성, 난품질, 면역 반응 및 혈액 성상에 긍정적인 영향을 미치지 않는다고 판단된다.
본 연구는 고온 환경에서 사료내 트립토판과 나이아신의 첨가가 산란계의 생산성, 난품질, 지방간 지표 및 혈액성상에 미치는 상호작용 효과를 조사하고자 수행되었다. 총 384수의 25주령 로만 갈색종 산란계를 4처리 8반복으로 반복당 12수씩 무작위 임의 배치하였다. 기본 사료는 트립토판과 나이아신의 추가적인 첨가는 없으며 모든 영양소 및 에너지는 로만갈색종 산란계의 요구량에 충족하거나 초과하도록 배합되었다. 사료 처리구는 2 × 2 요인 실험 설계법으로 두 가지 수준의 트립토판(0 및 0.16%)과 두 가지 수준의 나이아신(0 및 0.03%)이 포함되었다. 모든 산란계의 사양환경은 일반 농가에서 낮시간에 온도가 올라가는 점을 고려하여 일일 중 8시간은 온도 31.4 ± 1.17℃, 습도 86.0 ± 4.28%으로 설정하였으며, 나머지 16시간은 온도 26.7 ± 1.10℃, 습도 61.7 ± 6.34%로 유지하여 주기적인 고온 환경을 조성하였다. 실험은 10주간 진행되었다. 실험 결과 사료내 트립토판과 나이아신의 주요 효과와 상호작용은 나타나지 않았다. 이와 유사하게, 난각 강도, 난각 두께, 난각색, 난황색 및 호우유닛에 대한 상호작용 도 나타나지 않았다. 주요 효과로 0.03%의 나이아신 첨가는 난황색을 유의적으로 감소시켰으나 호우유닛은 유의적으로 증가시켰다. 하지만, 0.16%의 트립토판 첨가는 난품질에 영향을 끼치지 않았다. 지방간 지표와 혈액성상에서 사료내 트립토판과 나이아신의 주요 효과 및 상호작용은 나타나지 않았다. 결론적으로, 본 연구에서 설정한 농도의 사료내 트립토판과 나이아신의 첨가는 고온 환경에서 사양되는 산란계의 생산성, 난품질, 지방간 지표 및 혈액성상에 긍정적인 영향을 미치지 않았다.
This paper reports the results of an experimental examination using X-rays to test annealing materials for lapped bearing steel (STB2), to confirm the validity of the weighted averaging analysis method. The distribution behavior for the sin diagram and the presence or absence of differences in the peak method, half-value breadth method, and centroid method were investigated. When lapping the annealed bearing steel (STB2) material, a residual stress state with a non-directional steep gradient appeared in the surface layer, and it was found that the weighted averaging analysis method was effective. If there is a steep stress gradient, the sin diagram is curved and the diffraction intensity distribution curve becomes asymmetric, resulting in a difference between the peak method, half-value breadth method, and centroid method. This phenomenon was evident when the stress gradient was more than 2~3 kg/mm2/μm. In this case, if the position of the diffraction line is determined using the centroid method and the weighted averaging analysis method is applied, the stress value on the surface and the stress gradient under the surface can be obtained more accurately. When the stress gradient becomes a problem, since the curvature of the sin diagram appears clearly in the region of sin > 0.5, it is necessary to increase the inclination angle as much as possible. In the case of a lapping layer, a more accurate value can be obtained by considering in the weighted averaging analysis method. In an isotropic biaxial residual stress state, the presence or absence of can be determined as the presence or absence of strain for sin≈0.4.
작물 수분스트레스 지수(CWSI; Crop Water Stress Index)를 통해 관개 시기를 판단할 경우, 정확한 잎의 온도 및 대기 환경을 측정하는 것이 중요하다. 그리하여 본 연구에서는 실시간으로 작물의 생체정보(엽온) 및 대기 환경(대기온·습도, 일사량)을 측정하고 자동으로 CWSI 값이 산정되는 휴대용 수분스트레스 계측기기를 개발하였다. 또한 휴대용 수분스트레스 계측기기와 고정식 온도 측정 방법과의 비교 분석을 통해 휴대용 수분스트레스 계측기기의 성능을 평가하고자 하였다. 본 계측기기는 CWSI 산정을 위한 생체신호 및 기상 데이터를 측정하는 센싱부, 측정된 데이터를 저장하고 CWSI를 산정하는 데이터 수집부, 장치의 기능을 조작하고 측정값을 표시하는 시스템 제어부로 구성하였다. T-test를 실시하여 두 계측 방법에서 측정된 엽온, 일사량, CWSI 평균값의 유의 관계를 분석한 결과, 유의확률은 0.089, 0.318 그리고 0.028로 각각 나타났다. 엽온과 일사량은 유의수준 0.05보다 크므로 유의미한 차이가 나타나지 않았지만 CWSI는 유의확률이 유의수준보다 작으므로 두 측정 방법에 따라 유의미한 차이가 나타났다.
Aluminum nitride having a dense hexagonal structure is used as a high-temperature material because of its excellent heat resistance and high mechanical strength; its excellent piezoelectric properties are also attracting attention. The structure and residual stress of AlN thin films formed on glass substrate using TFT sputtering system are examined by XRD. The deposition conditions are nitrogen gas pressures of 1 × 102, 6 × 103, and 3 × 103, substrate temperature of 523 K, and sputtering time of 120 min. The structure of the AlN thin film is columnar, having a c-axis, i.e., a <00·1> orientation, which is the normal direction of the glass substrate. An X-ray stress measurement method for crystalline thin films with orientation properties such as columnar structure is proposed and applied to the residual stress measurement of AlN thin films with orientation <00·1>. Strength of diffraction lines other than 00·2 diffraction is very weak. As a result of stress measurement using AlN powder sample as a comparative standard sample, tensile residual stress is obtained when the nitrogen gas pressure is low, but the gas pressure increases as the residual stress is shifts toward compression. At low gas pressure, the unit cell expands due to the incorporation of excess nitrogen atoms.
해기사의 과도한 직무스트레스는 신체적, 정신적으로 부정적인 영향을 미치며, 이로 인한 이직은 원활한 해기인력 수급에 영향을 미칠 수 있다. 본 연구에서는 해기사의 체계적인 직무스트레스 측정 및 관리를 위한 도구로써 모바일 웹 애플리케이션을 개발 하고 품질평가를 통하여 검증하였다. 애플리케이션의 개발은 전통적인 소프트웨어 개발 방식인 Waterfall 모델에 따라 수행되었다. 요구분석 단계에서는 현직 해기사 및 해상직원 인사담당자 각 5명을 대상으로 Brain Storming을 실시하고 그 결과를 설계에 반영하였다. 설계 및 개발 단계에서는 요구사항 분석 결과를 바탕으로 애플리케이션을 설계하고, JSP와 Spring Framework를 활용하여 기능을 구현하였다. 애플리케이션의 작동 Test를 수행한 결과 사용자 인터페이스에서 입력한 직무스트레스, 정신건강, 진로적응성 등 입력 데이터에 따른 정상적인 출력 결과가 도시되었으며, 관리자 인터페이스에도 응답자의 입력 결과가 정상적으로 도시되고, 데이터베이스로 구성됨을 확인하였다. 요구사항 분석 참여 집단을 대상으로 ISO/IEC 9126-2 메트릭 기반의 5점 척도 품질평가를 시행한 결과 사용자 인터페이스 4.70점, 관리자 인터페이스 4.72점으로 유의한 결과가 도출되었다. 본 연구를 통해 개발한 애플리케이션은 사용자 요구를 반영한 지속적인 개정 및 보완이 필요하며, 향후 수집된 Data의 분석 및 활용을 위한 시스템 구축에 관한 연구가 필요하다.
Stress can provoke various symptoms in human. It can affect our thoughts, emotion, and behavior. In general, it is necessary but dangerous if we do not control the level. This study tried to develop a game to measure stress level of game-player and verify whether the score measured by the game correlates with stress level measured by self-reported surveys. A simple prototype of game to measure player’s stress level was developed based on Odd-one out experimental paradigm that allow to measure attentional engagement and disengagement in stress people. 50 students and 50 office-workers played the game to measure stress level and the data was analyzed with correlation analysis between stress score measured by the game and that measured by surveys (type-D and perceived stress scale). The results showed that there is significant correlation between two stress scores measured by computer game and the perceived stress scale but no correlation between the stress score measured by computer game and that measured by type-D. This indicate that the game developed based on attentional movement can measure in general stress level related to current concerns but not long-term temperature related to stress. Some limits and precautions of stress measurement with computer game such as reaction time or statistical assumption were discussed.
As contemporary society has become more complicated, specialized, and segmented, people are experiencing more diverse types of stress. In particular, while several factors associated with job stress have been examined among nurses, who belong to a professional group, the existing research has made no quantitative assessments of stress that reflect temporal differences in individuals. Therefore, the aim of this study is to understand the effects of job stress on alpha-amylase with regard to the working hours of nurses, to assess the variations in jobs stress over time, and provide basic data to improve the quality of nursing services. Ninety nurses working in three shifts in general, emergency, and intensive care wards of a university hospital in D City participated in this study. Salivary alpha-amylase (SAA) was extracted and analyzed at two-hour intervals from 07:00 to 15:00 from nurses on the day shift and from 23:00 to 07:00 from those working the night shift. The SAA level was highest between 23:00 and 01:00 for nurses in general wards (mean±S.D. 39.00±14.88) and between 11:00 and 13:00 for those in both intensive care units and emergency wards (mean ± S.D. 67.50 ± 62.93 and mean ± S.D. 39.67±35.96, respectively). The characteristic variation in SAA was significant between 23:00 and 01:00 (p < 0.01) and for those in their fifties or older (p < 0.01). The activation ratio of alpha-amylase, a stress reactant, showed an increase when the sympathetic nervous system was activated by mental stress; in addition, job stress was manifested with the effect of awakening at different time segments and at different ages among the nurses. With the aim of raising the level of service based on the nurses maintaining their mental health, it is necessary to focus sharply on the time segment for critical control and to conduct repetitive studies to determine the divisions of eustress critical values as well as to expand the population.
In general, it is required mechanical properties and strength tests to use the material in engineering applications. The material fringe values of photoelastic materials vary with the supplier, the batch of resin, temperature and age, it is necessary to calibrate each of sheet of photoelastic material at the time of the test. In this paper, we perform tensile tests and calibrations tests for photoelastic stress fringe constant in order to obtain the mechanical properties of materials and photoelastic material fringe constants of PMMA and PSM-1. From this tests, the tensile strength of PMMA and PSM-1 were 100.5 MPa and 71.5 MPa, respectively. Also, the measured material stress fringe constants of PMMA and PSM-1 were 13.33 N/mm and 6.91 N/mm, respectively.
In a photoelastic experiment, it is necessary to know the material stress fringe constant of the photoelastic specimen to determine the stresses from the measured isochromatic fringe orders. This type of compensator was proposed by the previous researchers. The recent image processing development of the stress pattern provide a means for making convenient compensator. The material stress fringe constant is determined using the distributions of isochromatic fringes in the wedge shaped plate under tensile load. The stress fringe constant measured with this method is applied to obtain the stress distribution along the central line on the tapered shank of the wedge-shaped plate. Photoelastic results using the measured material fringe constant are compared with FEM analysis. Two results are comparable, so it can be seen for the measured material fringe constant to be valid.
Many polymers exhibits sufficient birefringence to be used as photoelastic specimen material. Common polymers as polymethylmethacrylate (PMMA) are often used as photoelastic specimen. In a photoelastic experiment, it is necessary to know the material fringe constant of the photoelastic specimen to determine the stresses from the measured isochromatic fringe orders. The material stress fringe constant is determined using the simple tension specimen. The stress fringe constant measured with this method is applied to obtain the stress distribution in a tensile plate with a circular hole. Photoelastic results using the measured material fringe constant are compared with FEM analysis. Two results are comparable, so it can be seen for the measured material fringe constant to be valid.
The author has proposed and verified the accuracy through experiments on a method of measurement through the use of sound waves that not only can quantitatively measure each of the dual directions of the fiber axis with high accuracy of membrane tension created on the surface of the membrane structure, but also can be easily operated in the field of construction. This paper reports the solution for problems of variables caused in the process of downsizing of the measurement equipment in order for practical use, and verifies the correspondence possibility of various stress ratios.
본 연구에서는 고추의 수분스트레스 반응을 최적으로 계측할 수 있는 알고리즘을 개발하기 위해 초분광 단파 적외선 영상기술을 적용하였다. 수분스트레스에 노출된 고춧잎의 단파적외선 분광영상을 획득하고 ANOVA 분석을 이용하여 수분스트레스 반응을 가장 잘 반영하는 파장영역을 선정하였다. 고춧잎의 단파적외선 초분광 영상을 이용하여 ANOVA 분석을 수행한 결과 수분스트레스 판별을 위한 최적 파장은 1449nm으로 물분자의 광 흡수 영역대와 거의 일치하였다. 최적 파장에서의 고춧잎 상대반사값을 가우시안 회귀분석을 통해 정상군과 토양흡착수압이 −20kPa과 −50kPa일 때의 스트레스군을 구분할 수 있는 임계값을 계산하고 이 값을 기준으로 단파적외선 영상을 이진화하여 수분스트레스 반응을 판 단할 수 있는 최종영상을 구축하였다. 결과 영상에서 정상군과 스트레스군의 토양흡착수압이 −20kPa인 잎의 경우 스트레스 반응을 보인 픽셀이 72%이었고, −50kPa인 잎에서는 스트레스 반응을 보인 픽셀이 84%로 12%차이 가 났다. 정상군과 스트레스 강도가 다른 시료의 경우 영상의 결과가 명확히 구분되는 것으로 나타나 단파적외선 영상기술이 고춧잎의 수분스트레스 상태를 정량적으로 나타낼 수 있는 기술임을 확인할 수 있었다.
In order to obtain the fundamental data for the marine ranch, this paper was carried out to investigate cortisol variation in blood according to adapted time in the measurement of auditory threshold. The groups were adapted at the experimental tanks for 0.5, 1, 3 and 6 hours, respectively. At the results, cortisol concentration had a deep connection with adapted time. In particular, cortisol concentration in the experimental group of 1 hour was significantly increased, whereas others showed no difference comparing with the control group. When classical conditioning method with the sound coupled with a delayed electric shock was given after the adapted time of 1 hour and 6 hours, the rate of the conditioning completion for 6 hours was higher than that of 1 hour. Therefore, this suggests that the sufficient adapted time was required for the accurate auditory threshold.
휨이나 압축에 저항할 수 없는 막재료에 적절한 장력을 도입함으로써 안정화 되는 막구조물은, 유지 관리면에 있어서 막면에 도입되어 있는 장력을 설계대로 유지하는 것이 매우 중요하지만, 준공후 막면에 도입되어 있는 장력을 정확하게 파악하기가 어렵다. 저자들은, 직방형의 경계를 가지는 막을 가청역의 음파를 이용해 진동시키고, 진동하는 막의 공진진동수를 측정함으로써 간접적으로 막장력을 측정하는 방법을 제안하고, 막을 진동시키는 음파로서 정현파와 화이트 노이즈를 이용해 검증실험을 해 왔다. 본 논문은 주요 막재료를 이용해 행한 막장력 측정 이론의 검증을 위한 실험 결과와, 실재하는 막구조물의 장력측정을 통해, 본 측정장치의 정확성과 폭 넓은 적용성 및 측정에 있어서의 안정성을 검증한다.