        2.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to analyze the effect of temperature and humidity on the measured Particulate Matter (PM) concentrations recorded by PMS5003T, a low-cost light scattering type measuring tool. A regression analysis was performed on the ratio of PM concentrations measured by the light scattering method and the beta-ray absorption method according to temperature and humidity in an outdoor environment. As the temperature decreased, the PM concentration ratio increased, and this tendency intensified below 0oC. As the humidity increased, the PM concentration ratio increased, but the effect was less than the temperature effect. The coefficients of determination for temperature and humidity were R2 = 0.325 and 0.003, respectively, and the effects of temperature and humidity on the measured values w ere formulated and compensated for. As a result of the compensation, R2, relative precision, accuracy and RMSE improved from 0.927 to 0.958, from 91.183% to 96.651%, from 31.383% to 74.058%, and from 13.517 μg/m³ to 6.690 μg/m³, respectively. Finally, results from this study indicate that the reliability of the low-cost light scattering type PM sensor can be improved by applying the temperature and humidity compensation method.
        4,000원
        3.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The study analyzed performance assessment factors of odor sensors from 4 different manufacturers, including minimum detection limit, humidity stability and temperature stability. In the minimum detection limit assessment, only one electrochemical gas sensor was able to detect ammonia and hydrogen sulfide at the concentration of 5 ppb. The standard deviation ratio was over 10%, and it increased as humidity rose. The range of temperatures in which the electrochemical and photoionization gas sensors could function well was between 25oC and 40oC, and the sensor output values were unstable at low temperatures. Regarding the temperature stability of the metal oxide semiconductor sensor for measuring complex odors, the sensor output values dropped considerably to 0~10oC, and were similar to the concentrations of odor gases generated at 25oC. The results of the test of odor sensor outputs after temperature and humidity pre-treatment revealed that the respective stable output values at 50% humidity and 25oC were similar to the concentrations of manufactured odors. In terms of temperature and humidity stability of the NH3, H2S and Complex odor sensors, all target substances had stable output values at 25~40oC and 50~65% relative humidity, and unstable values at low temperatures and high humidity. Therefore, implementing pretreatment systems including temperature and humidity correction (25~40oC, 50~65% RH) is necessary for the stable use of odor sensors.
        4,900원
        5.
        2018.10 서비스 종료(열람 제한)
        Prediction of compressive strength of concrete by Maturity Method is applied in construction site. However, due to the use of wired type high-priced equipment, economic efficiency and workability are falling. In this study, a newly developed concrete embedded wireless sensor is used to perform a mock-up test. Next, the concrete compressive strength of the Maturity Method is predicted using Saul and Plowman's function as measured temperature data. The predicted concrete strength at the beginning of the age was the actual strength and stiffness, but the error rate was less than 1% at 28th day.
        6.
        2018.04 서비스 종료(열람 제한)
        Prediction of the compressive strength of the maturity method has been studied by several researchers and has been applied to the construction of concrete structures. In order to apply the maturity method, which is a function related to temperature and time, it is important to measure the accurate temperature inside the concrete during the curing period. The purpose of this study is to verify the performance by analyzing sensitivity, measurement and transmission accuracy by exposing wireless embedded sensor to various curing environment.