검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 203

        22.
        2020.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, studies have been actively conducted on seismic design and improvement of the seismic performance of bridges, buildings, factories, and plants. In particular, heavy items that are being manufactured or waiting to be shipped from factories (such as generators, engines, and boilers) must be equipped with seismic stoppers to prevent them from moving or falling during an earthquake. Seismic stoppers should be suitably determined by the size and weight of these heavy items; however, they have no general design standard. In this study, structural analyses and seismic tests were conducted to evaluate the performance of newly designed seismic stoppers. Structural analysis was performed on three stopper models to estimate the external load at which the yield stress of the material was not exceeded. Based on the analysis results, a seismic test of the stopper was carried out in accordance with the AC156 test method. Finally, product specifications for all three seismic stopper models were determined and their static/dynamic load performance was evaluated.
        4,000원
        23.
        2020.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Analysis of the 2016 Gyeongju earthquake and the 2017 Pohang earthquake showed the characteristics of a typical high-frequency earthquake with many high-frequency components, short time strong motion duration, and large peak ground acceleration relative to the magnitude of the earthquake. Domestic nuclear power plants were designed and evaluated based on NRC's Regulatory Guide 1.60 design response spectrum, which had a great deal of energy in the low-frequency range. Therefore, nuclear power plants should carry out seismic verification and seismic performance evaluation of systems, structures, and components by reflecting the domestic characteristics of earthquakes. In this study, high-frequency amplification factors that can be used for seismic verification and seismic performance evaluation of nuclear power plant systems, structures, and equipment were analyzed. In order to analyze the high-frequency amplification factor, five sets of seismic time history were generated, which were matched with the uniform hazard response spectrum to reflect the characteristics of domestic earthquake motion. The nuclear power plant was subjected to seismic analysis for the construction of the Korean standard nuclear power plant, OPR1000, which is a reactor building, an auxiliary building assembly, a component cooling water heat exchanger building, and an essential service water building. Based on the results of the seismic analysis, a high-frequency amplification factor was derived upon the calculation of the floor response spectrum of the important locations of nuclear power plants. The high-frequency amplification factor can be effectively used for the seismic verification and seismic performance evaluation of electric equipment which are sensitive to high-frequency earthquakes.
        4,000원
        24.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        경주지진과 포항지진으로 수도관 파열과 상수도관 누수가 보고되었다. 따라서 상수도 시설의 지진안전성 확보는 지속적이고 안정적인 물공급을 위하여 중요한 이슈이다. 상수도관은 주로 도로 하부나 일반 성토지반에 매설되어있기 때문에 지진파에 의한 변형뿐만 아니라, 지반의 영구변형, 사면의 불안정성 및 지반 액상화 등에 의한 배관의 굽힘 변형이 발생하게 된다. 이러한 배관의 굽힘 변형이 과도하게 발생 되면 배관 이음부 변위허용량을 초과하여 손상 및 누수로 이어지게 된다. 따라 서, 상수도관 이음부의 허용 변형각이 산출되어야 지진으로 인한 지반의 변형에 대하여 상수도관의 지진안전성을 정확하게 평가할 수 있다. 상수도 시스템은 현장 상황과 설치 여건에 따라 다양한 종류의 상수도관을 이용하고 있다. 그중 주철 상수도관은 오랜 기간 사용되고 개선되어 일반적으로 널리 사용되고 있다. 본 연구에서는 한국주철관공업(주)에서 제작한 EZ-LOK 조인트가 적용된 주철 상수도관에 대하여 4점 굽힘시험을 수행하였으며, 매설된 주철 상수도관의 내진 및 내침하 설계기준인을 참조하여 지진안전성을 평가하였다.
        4,000원
        25.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        우리나라는 지진에 대해 비교적 안전한 지역으로 인식되고 있었으나, 최근 경주지진과 포항지진이 발생하면서 시설물에 상당한 피해가 발생되면서 지진피해 저감장치를 적용한 내진설계 및 보강에 대한 연구와 개발이 수행되고 있다. 이미 건축된 구조물의 유지⋅보수에 대한 관심이 높아짐에 따라, 구조물의 감쇠, 강성 등을 국부적으로 변화시켜 지진 하중에 의한 에너지를 흡수하고 소산시키는 내진설계 방식인 제진기술이 활용되고 있다. 그러나 강한 지진이 발생할 때 제진 장치의 손상으로 인하여 사용성이 매우 떨어지게 되는 문제점이 발생되고 있다. 최근에는 이러한 문제를 해결하기 위해, 구조물의 가새 부재에 별도의 열처리를 하지 않고 응력 제거만으로 원형복원이 가능한 초탄성 형상기억합금을 적용하는 연구가 진행되고 있다. 따라서 본 연구에서는 비좌굴 가새 부재에 초탄성 형상기억합금을 사용하여 자동복원이 가능한 프레임 구조물을 구성하여 비선형 정적해석을 수행하여 구조물의 내진성능을 평가하고, 초탄성 형상기억합금의 재료적 특성의 우수성을 검증하고자 한다.
        4,000원
        26.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A corrugated steel plate wall (CSPW) system is advantageous to secure the strength and stiffness required for lateral force resistance because of its high out-of-plane stability. It can also stably dissipate large amounts of energy even after peak strength. In this paper, a preliminary study has been carried out to use the CSPW system in the seismic retrofit of existing reinforced concrete (RC) moment frame buildings. The seismic performance for an example building was evaluated, and then a step-by-step retrofit design procedure for the CSPW was proposed. An equivalent analytical model of the CSPW was also introduced for a practical analysis of the retrofitted building, and the strengthening effect was finally evaluated based on the results of nonlinear analysis.
        4,000원
        27.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Nonlinear static analysis and preliminary evaluation were performed in this study to evaluate the seismic performance of unreinforced masonry buildings subjected to various soil conditions based on the revised Korean Building Code. Preliminary evaluation scores and nonlinear static analyses indicated that all buildings were susceptible to collapse and did not reach their target performance. Therefore, retrofit of those building models was carried out through a systematic procedure to determine areas to be strengthened. It was possible to make most building models satisfy performance objectives through the reinforcement alone of damaged external shear walls. However, the application of a preliminary evaluation procedure to retrofit design was found to be too conservative because all the retrofitted building models verified with nonlinear static analysis failed to satisfy performance objectives. Therefore, it is possible to economically retrofit unreinforced masonry buildings through the fortification of external walls if a simple evaluation procedure that can efficiently specify vulnerable parts is developed.
        4,000원
        28.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 국내에서 발생한 경주지진 및 포항지진이 도심지 및 원자력발전소 주변에서 발생함에 따라 인근 주요 구조시스 템에 피해를 발생시킨 바 있다. 이에 따라, 본 연구는 원전 배관계통의 지진 거동 특성을 실험 및 해석적으로 규명하고, 이를 바탕으로 내진성능을 평가하는 연구를 수행하는 것을 목적으로 한다. 이를 위하여, 원전 배관계통을 대상으로 한 진동대 시험 결과를 바탕으로 배관 수치해석 모델을 수립하고 이를 시험 결과를 통하여 검증한다. 또한, 이러한 검증된 수치해석모델을 기반으로 배관계통의 내진성능을 평가한다. 수치해석 모델 검증 결과, 수립된 수치모델의 고유진동수, 감쇠비 및 변위 응답이 진동 대시험 결과와 유사한 것으로 나타났다. 이러한 검증된 수치모델을 바탕으로 평가된 내진성능 값은 기존 원전 배관의 내진성능 값의 범위와 비교적 유사한 값으로 평가되었다. 이는 설계기준지진을 크게 상회하는 값이지만, 원전 주요 기기 임을 감안할 때 추가적인 내진성능 상향이 확보되면 원전 지진 안전성 향상에 많은 기여를 할 수 있을 것으로 판단된다. 본 연구의 결과는 추후 원전 배관계통 내진성능평가를 위한 정량적인 자료로 활용이 가능할 것으로 판단된다.
        4,000원
        29.
        2020.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is to investigate the effect of a retrofitted reinforced concrete frame with non-seismic details strengthened by embedded steel moment frames with an indirect joint, which mitigates the problems of the direct joint method. First, full-scale experiments were conducted to confirm the structural behavior of a 2-story reinforced concrete frame with non-seismic details and strengthened by a steel moment frame with an indirect joint. The reinforced concrete frame with non-seismic details showed a maximum strength of 185 kN at an overall drift ratio of 1.75%. The flexural-shear failure of columns was governed, and shear cracks were concentrated at the beam-column joints. The reinforced concrete frame strengthened by the embedded steel moment frames achieved a maximum strength of 701 kN at an overall drift ratio of 1.5% so that the maximum strength was about 3.8 times that of the specimen with non-seismic details. The failure pattern of the retrofitted specimen was the loss of bond strength between the concrete and the rebars of the columns caused by a prying action of the bottom indirect joint because of lateral force. Furthermore, methods are proposed for calculation of the specified strength of the reinforced concrete frame with non-seismic details and strengthened by the steel moment frame with the indirect joint.
        4,000원
        30.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of the paper is to introduce a system that reduces the occurrence of weak-story in the event of earthquake. Weak-story concentrates deformation on the story and causes all member to collapse before the capacity of all member is reached. This paper introduces Strong-Back system (SB) to protect weak story. SB is a hybrid of zipper frame, tied eccentrically braced frame, and elastic truss system and it is divided into elastic and inelastic areas. Elastic areas prevent the generation of weak story by distributing energy, and inelastic areas dissipate energy through buckling or yielding. In this paper, the seismic performance is evaluated by comparing the four type braced frame with SB through push-over analysis. The four criteria are compared from the base shear, the ductility capacity, the column failure order, and the quantity of brace. As a result, SB proved to have sufficient performance to protect the weak-story.
        4,000원
        31.
        2019.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        우리나라는 지진으로부터 안전한 국가라는 인식이 형성되었으나 최근 경주와 포항 지진에 의해 발생된 구조물 피해로 구조물 안전성 확보를 위한 관심이 증가하고 있다. 국내 중저층 건축물에 다수 적용되고 있는 철골 모멘트 골조는 기본적인 내진성능을 보유하고 있지만 보-기둥 접합부의 소성변형으로 인한 취성파괴로 다양한 문제를 발생시킨다. 최근에는 이러한 문제를 해결하기 위해 구조물에 상온에서 잔류변형으로부터 원형복원이 가능한 초탄성 형상기억합금의 활용에 관한 연구가 진행되고 있다. 따라서 본 연구에서는 소성변형이 집중되는 보 플랜지 부재에 초탄성 형상기억합금 보강판을 활용한 보–기둥 접합부에 대하여 실험을 통한 실질적인 내진성능을 평가하고자 한다.
        4,000원
        32.
        2019.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기존 내진보강시스템의 문제점을 개선하기 위한 듀얼프레임형 내진보강시스템은 기존구조체, 외부보강체, 댐퍼로 구성된다. 듀얼시스템은 지진발생시 주기차이로 인하여 기존구조체와 외부보강체 사이에서 상대변형이 발생되고 이를 댐퍼가 대응하여 안정적으로 지진에너지를 흡수하여 내진성능을 확보한다. 본 논문에서는 듀얼시스템의 구조성능을 분석하기 위하여 정적반복가력실험을 수행한다. 실험결과, 듀얼시스템 실험체는 비보강 실험체와 유사한 손상상태를 나타내었다. 이와 같이 나타난 이유는 정적실험 시 기존구조체를 강제 이력 시켰기 때문이다. 하지만 하중-변형관계곡선에서 핀칭현상이 완화되는 것으로 나타났고, 안정적인 이력거동을 통하여 비보강 실험체에 비해 5.3배 더 많은 에너지를 흡수하였다. 또한 동일한 층간변형각 및 누적 변형에 대해서도 더 많은 에너지를 흡수할 수 있음에 따라 듀얼시스템을 적용할 경우 내진성능을 향상시킬 것으로 판단된다. 또한 듀얼시스템을 실무에 적용하기 위해서는 설계프로세스 등에 대한 연구가 필요하며, 본 논문을 추후 연구의 기초자료로 제시하고자 한다.
        4,000원
        35.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구의 목적은 인공신경망 기법을 이용하여 사면의 내진 성능을 비교적 정확하면서도 효율적으로 예측하는 모델을 도 출하는데 있다. 사면의 내진 성능은 지진입력 및 사면모델의 무작위성 및 불확실성으로 인하여 정량화하기 쉽지 않다. 이러한 배경 아래 사면에 대한 확률론적 지진 취약도 분석이 몇몇 연구자에 의해 수행되었고, 이를 기반으로 다중 선형회귀분석 을 통하여 사면 내진성능에 대한 닫힌식이 제안된 바 있다. 그러나 전통적인 통계학적 선형회귀분석은 다양한 조건의 사면과 이에 따른 내진 성능 사이의 비선형적 관계를 정확하게 표현하지 못하는 한계를 보였다. 이에 따라 본 연구에서는 이러한 문제점을 극복하고자 인공신경망 기법을 사면 내진성능 예측 모델을 생성하는데 적용하였다. 도출된 모델의 유효성은 기존 의 다중 선형 및 다중 비선형 회귀분석을 통한 모델과 비교하여 검증하였다. 결과적으로 이전 연구의 전통적인 통계학적 회귀 분석을 통한 모델과 비교 결과, 기본적으로 인공신경망 기법을 통하여 도출된 모델이 사면의 내진성능을 예측하는데 있어 우수한 성능을 보여주었다. 이러한 정확도 높은 모델은 향후 확률에 기반한 사면의 지진취약도 지도를 개발하고, 주요 구 조물의 인근 사면으로 인한 리스크를 효과적으로 평가하는데 활용될 수 있을 것이라 기대된다.
        4,000원
        36.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the precedent study, the retractable-roof spatial structure was selected as the analytical model and a tuned mass damper (TMD) was installed to control the dynamic response for the earthquake loads. Also, it is analyzed that the installation location of TMD in the analytical model and the optimal number of installations. A single TMD mass installed in the analytical model was set up 1% of the mass of the whole structure, and the optimum installation location was derived according to the number of change. As a result, it was verified that most effective to install eight TMDs regardless of opening or closing. Thus, in this study, eight TMDs were installed in the retractable-roof spatial structure and the optimum mass ratio was inquired while reducing a single TMD. In addition, the optimum mass distribution ratio was identified by redistributing the TMD masses differently depending on the installation position, using the mass ratio of vibration control being the most effective for seismic load. From the analysis results, as it is possible to confirm the optimum mass distribution ratio according to the optimum mass ratio and installation location of the TMD in the the retractable-roof spatial structure, it can be used as a reference in the TMD design for large space structure.
        4,000원
        38.
        2019.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Most school buildings consist of reinforced concrete (RC) moment frames with masonry infills. The longitudinal direction frames of those school buildings are relatively weak due to the short-column effects caused by the partial masonry infills and need to be evaluated carefully. In ‘Manual for Seismic Performance Evaluation and Retrofit of School Facilities’ published in 2018, response modification factor of 2.5 is applied to non-seismic RC moment frames with partial masonry infills, but sufficient verification of the factor has not been reported yet. Therefore, this study conducted seismic performance evaluation of planar RC moment frames with partial masonry infills in accordance with both linear analysis and nonlinear static analysis procedures presented in the manual. The evaluation results from the different procedures are compared in terms of assessed performance levels and number of members not meeting target performance objectives. Finally, appropriate response modification factors are proposed with respect to a shear-controlled column ratio.
        4,300원
        39.
        2018.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigates the seismic performance of a hybrid seismic energy dissipation device composed of a viscoelastic damper and a steel slit damper connected in parallel. A moment-framed structure is designed without seismic load and is retrofitted with the hybrid dampers. The model structure is transformed into an equivalent simplified system to find out optimum story-wise damper distribution pattern using genetic algorithm. The effectiveness of the hybrid damper is investigated by fragility analysis of the structure with and without the dampers. The analysis results show that after seismic retrofit the probability of reaching damage states, especially the complete damage state, of the structure turn out to be significantly reduced.
        4,000원
        40.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Following a 5.8 magnitude earthquake on September 12, 2016 in Gyeongju Province, a magnitude 5.4 earthquake occurred in the northern region of Pohang City on November 15, 2017 in South Korea. Only 7.9 % of the building structures are earthquake-resistant, according to the recent survey conducted by the government agencies in October 2017. In this paper, the linear analysis seismic performance evaluation procedure of the existing school structures presented in the revised methodology(Seismic Performance Evaluation Procedure and Rehabilitation Manual for School Facilities) was introduced. In this paper, the linear analysis evaluation procedure presented in the revised methodology was introduced and the seismic performance index of the example structure was evaluated using the linear analysis evaluation procedure. The seismic retrofit was verified by the linear and nonlinear dynamic analyses using Perform 3D. The analysis results show that the dissipated inelastic energy is concentrated on the retrofitted shear wall and the maximum inter-story drift of the stadium model structure with damping system satisfies the requirement of the current code.
        4,000원
        1 2 3 4 5